MQMartino Quintavalla

Martino Quintavalla

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Martino Quintavalla has a total of 62 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of heat and steam bending on the longitudinal and radial mechanical properties and derived acoustical indices of spruce and maple wood

    by Martino Quintavalla, Jérémy Cabaret, Maurizio Santini, Romain Viala

    This study investigates the effects of steam and heat bending on the longitudinal and radial vibro-mechanical properties of spruce ( Picea abies ) and maple ( Acer spp. ). More than 100 thin beams were bent to nominal strain levels of approximately 0.7 % and compared to reference specimens using laser vibrometry and modal analysis combined with finite element model updating. X-ray microtomography (2 μm voxel size) was performed on selected specimens to examine the cellular-scale integrity after bending. After re-conditioning at 50 % RH and 25 °C, density showed no statistically significant change. A modest reduction in longitudinal stiffness was observed, more pronounced in spruce, while the longitudinal loss factor increased significantly for both species, leading to decreased radiation ratio and acoustic conversion efficiency indices, particularly in spruce. These results provide quantitative trends relevant to manufacturing of bent wood, the mechanical and vibroacoustical design of bent wood parts and structures.

  • Effect of thermal modifications on the anisotropic acoustic properties of spruce and their relevance for stringed instruments

    by Martino Quintavalla, Romain Viala, Maurizio Santini, Simone Bonanomi

    Thermal modification alters wood properties and helps improving dimensional stability against humidity changes, making it a promising treatment for wood used in stringed instrument construction. Its effects on the anisotropic mechanical and acoustical properties, however, remain incompletely understood. In this study, spruce samples were analyzed to quantify changes in physical, mechanical, and acoustical properties following thermal modification at 160 °C. Density, orthotropic viscoelastic constants, and damping were measured using non-destructive techniques, while microstructural effects were examined via x-ray microtomography. Finite element analysis of a guitar soundboard assessed impacts on eigenfrequencies, mode shapes, and acoustic radiation. Results indicate that thermal treatment causes a slight reduction in density, a modest increase in longitudinal and radial stiffness, and a significant decrease in damping, leading to enhanced radiation ratio and acoustic conversion efficiency. Microstructural observations suggest that removal of resins and volatile extractives may underlie these changes. Finite element analysis shows that eigenmodes shape remain largely unchanged, with only minor shifts in eigenfrequencies. The combination of improved radiation efficiency and reduced damping could influence sound radiation and string-to-soundboard coupling.


  • Survey and evaluation of classical guitar soundboard design methods with finite element analysis

    by Martino Quintavalla, Maurizio Santini, Giuliano Nicoletti

    Designing the soundboards of guitars based on an acoustical and structural approach would ideally allow for the realization of instruments with reproducible acoustical properties and structural stability. This task is challenging because wood, the most common material used for this purpose, is a natural material with variable properties and building instruments using strict geometrical tolerances alone does not ensure reproducible results. Several approaches have been developed so far, some based on tradition and, more recently, on measurement of material properties and computer optimization. In this article, some approaches used to design classical guitar soundboards are reviewed and evaluated. An original builder-friendly method, based on simple definitions of mass and stiffness, is also considered. Finite element analysis is used to evaluate their robustness against variability in wood density and orthotropic stiffness by using the experimentally measured properties of 29 spruce specimens. The results are assessed by comparing the coefficient of variation of acoustically relevant parameters (eigenmodes, eigenfrequencies, mass, and monopole mobility) as well as structurally significant ones (mechanical stiffness of the soundboard and bridge rotation angle). Additionally, the correlation between sound radiation coefficient and monopole mobility is examined. Finally, the practical applicability of these methods is evaluated and discussed.


  • Open Access

    Acoustical Survey and Finite Element Analyses of Late Baroque Mandolin

    by Martino Quintavalla, Federico Gabrielli, Claudio Canevari

    Replicating ancient musical instruments is a method to protect fragile originals from extensive playing. In the case of stringed instruments, replicas are generally realized by luthiers using identical wood species and geometry, according to dimensional surveys. Although this procedure yields a highly similar visual aspect, the intrinsic variability of wood properties does not ensure an identical sound. Therefore, acoustic surveys are a fundamental step in reproducing the sounds of original instruments. In this work, we report the acoustical survey of a late baroque mandolin preserved at Museo degli Strumenti Musicali del Castello Sforzesco di Milano. The survey was conducted using portable equipment and included measurements of the radiated sound spectrum, admittance, monopole mobility, and mode shape assignment. Finite Element Analyses (FEA) enabled the assignment of mode shapes and quantification of the effect of a crack on the structural integrity and acoustics of the instrument. This study has laid the foundation for the creation of a replica that, beyond the visual aspect, would resemble the original instrument in terms of sound to the extent feasible.


  • Open Access

    The Acoustics of Traditional Italian Mandolins and Their Relation with Soundboard Wood Properties

    by Martino Quintavalla, Federico Gabrielli, Claudio Canevari

    Stringed musical instruments, which have a long and rich worldwide cultural history, have slowly evolved from ancient lutes to contemporary instruments such as the Italian mandolin. The mandolin has been an iconic element of Italian musical tradition and culture for more than 400 years. In this study, we report on the acoustic characterization of modern Italian mandolins in terms of bridge admittance, sound radiation, and modal shape measurements. The vibrational behavior of the soundboard was studied by means of finite element analysis (FEA) to establish a link between the mechanical and physical properties of wood and the acoustic response of the instrument. This study presents some important features of the acoustic behavior of mandolins and sheds some light on the influence of wood properties on the instrument’s timbre and its variability.


  • Plug-and-play adaptive optics for commercial laser scanning fluorescence microscopes based on an adaptive lens

    by Paolo Pozzi, Martino Quintavalla, A. B. Wong, J. G. G. Borst, Stefano Bonora, Michel Verhaegen, Gerard Borst

    In this Letter, we present a solution for simple implementation of adaptive optics in any existing laser scanning fluorescence microscope. Adaptive optics are implemented by the introduction of a multiactuator adaptive lens between the microscope body and the objective lens. Correction is performed with a sensorless method by optimizing the quality of the images presented on screen by the microscope software. We present the results acquired on both a commercial linear excitation confocal microscope and a custom-made multiphoton excitation microscope.


  • Correction of non-common path aberrations in pyramid wavefront sensors to recover the optimal magnitude gain using a deformable lens

    by Martino Quintavalla, Maria Bergomi, Demetrio Magrin, Stefano Bonora, Roberto Ragazzoni

    Adaptive optics (AO) correction based on pyramid wavefront sensors (P-WFSs) has been successfully implemented in several instruments for astronomical observation due to the P-WFS advantages in terms of sensitivity with respect to other WFSs, such as the Shack–Hartmann. The correction of non-common path aberrations (NCPAs) between the sensing and the scientific arm, commonly performed introducing offsets to the Zernike coefficients of the measured wavefront in the AO closed loop, reduces the sensitivity of P-WFSs causing a loss in sky coverage and scientific throughput. We propose a technique to exploit the full capabilities of P-WFSs compensating the NCPAs up to the fourth order on the WFS channel by means of a multi-actuator adaptive lens (MAL). We show the preliminary results obtained in a dedicated laboratory test bench.


  • Open Access

    XSAO: an extremely small adaptive optics module for small-aperture telescopes with multiactuator adaptive lens

    by Martino Quintavalla, Mattia Spagnol, Lyu Abe, Marcel Carbillet, Eric Aristidi, Jacopo Mocci, Riccardo Muradore, Stefano Bonora

    The Journal of Astronomical Telescopes, Instruments, and Systems (JATIS) publishes peer-reviewed papers reporting on original research in the development, testing, and application of telescopes, instrumentation, techniques, and systems for ground- and space-based astronomy.


  • Adaptive optics in the mouse eye: wavefront sensing based vs image-guided aberration correction

    by Daniel J. Wahl, Pengfei Zhang, Jacopo Mocci, Martino Quintavalla, Riccardo Muradore, Yifan Jian, Stefano Bonora, Marinko V. Sarunic, Robert J. Zawadzki

    Adaptive Optics (AO) is required to achieve diffraction limited resolution in many real-life imaging applications in biology and medicine. AO is essential to guarantee high fidelity visualization of cellular structures for retinal imaging by correcting ocular aberrations. Aberration correction for mouse retinal imaging by direct wavefront measurement has been demonstrated with great success. However, for mouse eyes, the performance of the wavefront sensor (WFS) based AO can be limited by several factors including non-common path errors, wavefront reconstruction errors, and an ill-defined reference plane. Image-based AO can avoid these issues at the cost of algorithmic execution time. Furthermore, image-based approaches can provide improvements to compactness, accessibility, and even the performance of AO systems. Here, we demonstrate the ability of image-based AO to provide comparable aberration correction and image resolution to the conventional Shack-Hartmann WFS-based AO approach. The residual wavefront error of the mouse eye was monitored during a wavefront sensorless optimization to allow comparison with classical AO. This also allowed us to improve the performance of our AO system for small animal retinal imaging.


  • Improvement of coupling efficiency in free-space optical communication with a multi-actuator adaptive lens

    by Seyed Ayoob Moosavi, Martino Quintavalla, Jacopo Mocci, Riccardo Muradore, Hossein Saghafifar, Stefano Bonora

    In free-space optical communication, the propagation of a laser beam through the atmosphere causes wavefront distortions that decrease the coupling efficiency (CE) from free space to single-mode fiber. This tremendously degrades the performance of the communication channel even in the case of weak turbulence regime. In this Letter, we demonstrate that a multi-actuator adaptive lens working in closed loop with a wavefront sensor can strongly reduce the effect of turbulence while reducing the system complexity with respect to correction systems using deformable mirrors or liquid crystal spatial light modulators. We obtain a three-fold increase in the CE in weak turbulence regime.