VTVipul L. Tanna

Vipul L. Tanna

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vipul L. Tanna has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Feasibility Study of HTS Current Leads With MgB2 Shunt for Tokamak Application

    by Nitin Bairagi, Vipul L. Tanna, Hiren Nimavat, Dashrath Sonara, Atul Garg, Rohitkumar Panchal, Gaurang Mahesuria, Rakeshkumar Patel, Dikens Christian, Gaurav Purwar, et al.

    Gas helium cooled HTS/MgB 2 based hybrid superconducting current feeders system have potential benefits in terms of better temperature margin and cryo stability for superconducting tokamaks and accelerators. As a proof of principle, a hybrid current feeders system comprising of a 3.3 kA rated prototype HTS current leads (CL) pair equipped with a meter long in-house developed MgB 2 shunt is recently tested at the Institute for Plasma Research (IPR). The prototype HTS CL and its bottom MgB 2 shunt is tested up to the maximum rated current of 3.3 kA with a ramp rate up to 300 A/s. The heat exchanger (HX) part is cooled using liquid nitrogen (LN 2 ). The HTS module utilizes BSCCO-2223 tapes. The bottom MgB 2 shunt section is cooled near 5 K–10 K using cold helium gas from a liquid helium Dewar. Prior to helium cooling, HX is pre-cooled to 80 K by utilizing LN 2 that allows HTS module and bottom MgB 2 shunt section conduction cooing thus optimizing and saving helium consumption. The scarcity of liquid helium in the market makes HTS/MgB 2 based superconducting current feeders a prominent candidate for large scale SC magnets application. The integrated test set-up is equipped with necessary sensors and diagnostics for detailed characterization. The temperature distribution at various sections of CL are reported in detail under cold and charging conditions. Here, we report the detailed experimental characterization results for HTS CL equipped with MgB 2 shunt under cold conditions. The main outcomes from the experiment are presented and discussed in detail.


  • Test Results of a Prototype HTS Current Lead With MgB2 and NbTi Superconducting Joints

    by Nitin Bairagi, Vipul L. Tanna, Hiren Nimavat, Dashrath Sonara, Rohitkumar Panchal, Atul Garg, Gaurang Mahesuria, Rakeshkumar Patel, Dikens Christian, Pradip Panchal, et al.

    Conventional vapor cooled current leads (CL) based on low-temperature superconductor are the major consumer of liquid helium in large-scale superconducting magnets-based nuclear fusion devices. Use of conduction-cooled, high-temperature superconductors (HTS) CL enable operation up to 80 K and saves significant cold capacity of cryo plant. Recently at Institute for Plasma Research, India, a 3.3 kA rated prototype HTS CL pair is developed with the help of Indian industries. It exploits various superconducting materials operating from 5 to 80 K. HTS module is based on commercially available rare earth cuprate oxide superconductor based BSCCO-2223 tapes. For testing purpose, we have developed bottom lap joints using composite magnesium diboride (MgB 2 ) wires as an intermediate between HTS module and NbTi: Cu cable that act as a shunt between CL pair. Such a hybrid concept is adopted as the next step to developing MgB 2 superconducting current feeder which could be operated near 20 K and save cryogenic cost in future fusion machines. Here, we report the salient features, basic details of HTS CL, superconducting joints fabrication, its test set-up, and experimental results. The inference from test results is then reported and discussed in detail.


  • Thermo-Hydraulic Study of MgB2 Superconducting Feeder for SST-1 Tokamak

    by Nitin Bairagi, Vipul L. Tanna

    Better cryo stability is mandatory for any superconducting feeders system of fusion devices as the large amount of the magnet-stored energy can be safely dumped via feeder path only. Magnesium diboride (MgB2) as a feeder may provide innovative solution in lieu of low temperature superconductor (LTS). It has a critical superconducting transition temperature (TC) of 39 K, ductile nature, ease of availability at a relatively lower cost. SST-1 Tokamak at IPR India utilizes NbTi/Cu based cable-in-conduit-conductors (CICC) for its superconducting (SC) feeders rated at 10 kA and designed to be cooled using forced-flow helium at 4.5 K, 0.4 MPa. In order to assess the suitability of MgB2 as feeder, we report a thermo-hydraulic study of 10 kA rated SC feeders for SST-1. The results show that MgB2 SC feeders can provide benefits of higher temperature margin at a lower mass flow rate with reduced pressure drop and the cryo plant capacity savings in comparison to existing NbTi based feeders.


  • Prediction of Helium Vapor Quality in Steady-State Two-Phase Operation of SST-1 Superconducting Toroidal Field Magnets

    by Gaurav Kumar Singh, Rohitkumar N. Panchal, Vipul L. Tanna, Subrata Pradhan

    Steady State Superconducting Tokamak (SST-1) at the Institute for Plasma Research (IPR) is the first superconducting Tokamak in India and is an ‘operational device’. Superconducting Magnets System (SCMS) in SST-1 comprises of sixteen Toroidal field (TF) magnets and nine Poloidal Field (PF) magnets employing cable-in-conduit-conductor (CICC) of multi-filamentary high current carrying high field compatible multiply stabilized NbTi/Cu superconducting strands. SST-1 superconducting TF magnets are successfully and regularly operated in a cryo-stable manner being cooled with two-phase (TP) flow helium. The typical operating pressure of the TP helium is1.6 bar (a) and the operating temperature is the corresponding saturation temperature. The SCMS weighing a cold mass of nearly thirty two tons has a typical cool-down time of about 14 days from 300 K down to 4.5 K using helium refrigerator/liquefier (HRL) system of equivalent cooling capacity of 1350 W at 4.5 K. Using the available of experimental data from the HRL, we have estimated the vapor quality during the cryo-stable operation of the TF magnets using the well-known correlation of two-phase flow. In this paper, we report the detailed characteristics of two-phase flow for given thermo-hydraulic conditions during long steady state operation of the SST-1 TF magnets as observed in the SST-1 experimental campaigns.


  • Open Access

    Two phase helium cooling characteristics in Cable-in Conduit Conductors

    by G. K. Singh, S. Pradhan, V. L. Tanna

    Cable-in-Conduit Conductors (CICCs) are used in the fabrication of superconducting fusion grade magnets. It acts as a narrow cryostat to provide cryo-stability with direct contact of coolant fluid to conductor. The superconducting magnets are cooled using forced flow (FF), supercritical helium or two phase (TP) cooling through void space in the CICC. Thermo-hydraulics using supercritical helium single phase flow is well-known and established. Research topic of behavior of forced flow, two phase (TP) helium cooling in CICC involves perceived risks of the CICC running into flow chocking and possible thermo-acoustic oscillations leading to flow instabilities. This research work involves study of forced flow two phase helium cooling in CICC wound superconducting magnets. The TP flow provides cryo-stability by the latent heat of helium not by enthalpy as in case of CICC being cooled with supercritical helium. Study reveals some attractive regimes in the case of TP cooling, at a given mass flow rate of single phase helium at the inlet and a heat flux acting on the CICC. Analysis carried out predicts significant gains with TP cooling on a prototype CICC, which is circular in cross section and appropriate for fusion devices for high magnetic field applications. These general formalisms may be extended to specific magnets wound with CICC. This paper describes analysis of TP cooling of a CICC.

  • Open Access

    Upgradation plans of SST-1 Cryogenics system at IPR

    by V L Tanna, Sst-1 Cryo Team, S Pradhan

    Steady State Superconducting Tokamak (SST-1) is India's First Superconducting Tokamak and has Toroidal Field (TF) and Poloidal Field (PF) superconducting coils along with the cold mass support structure weighing about 38 ton of cold mass. A 1.3 kW Helium refrigeration and liquefaction (HRL) at 4.5 K along with its distribution network facilitates the cooling down of the cold mass and cryo-stable operation of SST-1TF magnets. SST-1 experimental campaigns have revealed that the existing HRL is just sufficient for the heat loads acting on it. Further, the SST-1 PF magnets require a higher pressure head and mass flow rate than the nominal values on account of the longer paths of some of the PF magnets. In order to make SST-1 being fully superconducting device, we are introducing superconducting central solenoid (CS). Detailed estimates have been made and it has been found that an additional ~ 900 W at 4.5 K of cryo power is required towards (i) cooling all the PF magnets (ii) the cooling down and the operation of a new Nb3Sn based CS of SST-1. This paper will elaborate on (i) the experimental heat loads acting on the cryo system (ii) the 'thermal runaway amongst the PF magnets observed in the SST-1 campaign' (iii) the robust need of a higher operation pressure up to 2.1 bar (a) (iv) the need of the flow optimizations as per the hydraulic paths (v) the engineering solutions at each of these described (i)-(v) above.

  • Cryogenic Acceptance Tests of SST-1 Superconducting Coils

    by Aashoo N. Sharma, Upendra Prasad, Kalpesh Doshi, Pankaj Varmora, Yohan Khristi, Dipak Patel, A. Panchal, S. J. Jadeja, Vipul L. Tanna, Ziauddin Khan, et al.

    Toroidal field (TF) and poloidal field (PF) coils of steady-state superconducting tokamak (SST-1) have been fully refurbished to ensure cryostable and low-dc-resistance interpancake and intercoil joints, helium leak tightness of the winding pack, and ) 10 MΩ winding pack to ground insulation resistance under cold conditions. As per SST-1 mission mandate, all TF coils and PF3 Top had been cold tested at full operational parameters. A dedicated large coil test facility was integrated for these tests. Specially adapted solutions such as magnet preparation cum transport stand, demountable busbar supports, demountable sensor mountings, reusable joints for busbar connections inside cryostat, etc., were developed. These measures led to timely and successful completion of cold tests and integration of the magnet system on to the SST-1 machine shell. The functionality of various diagnostics of the magnet system was also established during these tests. Details of coil refurbishment, test facility, test campaigns, and some important test results are reported in this paper.