Debra L. Ellisor
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Debra L. Ellisor has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Benjamin A. Neely
Chemical Sciences Division, National Institute of Standards and Technology, Charleston, South Carolina 29412, United States
3 shared publications - William Clay Davis
National Institute of Standards and Technology, Charleston, SC
3 shared publications - Angela Folz
Statistical Engineering Division, National Institute of Standards and Technology, Boulder, USA
2 shared publications - Antonio Possolo
National Institute of Standards and Technology (NIST), Gaithersburg, MD, United States of America
2 shared publications - Mary Gregg
National Institute of Standards and Technology
2 shared publications W. Clay Davis
National Institute of Standards and Technology Materials Measurement Laboratory, Charleston, USA
2 shared publications
Latest Publications
- Open Access
- 6 March 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (12) , 2749-2750
Publisher Correction: Robust discrimination between closely related species of salmon based on DNA fragments
- 6 March 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (12) , 2749-2750
Open AccessPublisher Correction: Robust discrimination between closely related species of salmon based on DNA fragments
- Open Access
- 18 January 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (12) , 2579-2588
Robust discrimination between closely related species of salmon based on DNA fragments
Closely related species of Salmonidae, including Pacific and Atlantic salmon, can be distinguished from one another based on nucleotide sequences from the cytochrome c oxidase sub-unit 1 mitochondrial gene (COI), using ensembles of fragments aligned to genetic barcodes that serve as digital proxies for the relevant species. This is accomplished by exploiting both the nucleotide sequences and their quality scores recorded in a FASTQ file obtained via Next Generation (NextGen) Sequencing of mitochondrial DNA extracted from Coho salmon caught with hook and line in the Gulf of Alaska. The alignment is done using MUSCLE (Muscle 5.2) [1], applied to multiple versions of each fragment perturbed according to the nucleobase identification error probabilities underlying the quality scores. The Damerau-Levenshtein distance was used to determine the genetic barcode of the candidate species that is closest to each aligned, perturbed fragment. The “votes” that the sampled fragments cast for the different candidate species are then pooled and converted into identification probabilities, using weights determined by the entropy of the fragment-specific identification probability distributions. This novel approach to quantify the uncertainty associated with measurements made using NextGen Sequencing can be applied to discriminate closely related species, hence to value-assignment for reference materials supporting determinations of the authenticity of seafood, for example, NIST Reference Materials 8256 and 8257 (Coho salmon) [2].
- 18 January 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (12) , 2579-2588
Open AccessRobust discrimination between closely related species of salmon based on DNA fragments
Closely related species of Salmonidae, including Pacific and Atlantic salmon, can be distinguished from one another based on nucleotide sequences from the cytochrome c oxidase sub-unit 1 mitochondrial gene (COI), using ensembles of fragments aligned to genetic barcodes that serve as digital proxies for the relevant species. This is accomplished by exploiting both the nucleotide sequences and their quality scores recorded in a FASTQ file obtained via Next Generation (NextGen) Sequencing of mitochondrial DNA extracted from Coho salmon caught with hook and line in the Gulf of Alaska. The alignment is done using MUSCLE (Muscle 5.2) [1], applied to multiple versions of each fragment perturbed according to the nucleobase identification error probabilities underlying the quality scores. The Damerau-Levenshtein distance was used to determine the genetic barcode of the candidate species that is closest to each aligned, perturbed fragment. The “votes” that the sampled fragments cast for the different candidate species are then pooled and converted into identification probabilities, using weights determined by the entropy of the fragment-specific identification probability distributions. This novel approach to quantify the uncertainty associated with measurements made using NextGen Sequencing can be applied to discriminate closely related species, hence to value-assignment for reference materials supporting determinations of the authenticity of seafood, for example, NIST Reference Materials 8256 and 8257 (Coho salmon) [2].
- 29 January 2024
- Published by National Institute of Standards and Technology (NIST)
Certification of standard reference material® 2983 :
Standard Reference Material (SRM) 2983 Inorganics in Geoduck Clam Tissue (Panopea generosa) is intended to be used for the evaluation of methods for the determination of elements, arsenic species, and proximates in this and similar matrices. A unit of SRM 2983 consists of one jar containing approximately 12 g of cryogenically homogenized frozen material. This publication documents the production, analytical methods, and statistical evaluations involved in characterizing this material.
- 29 January 2024
- Published by National Institute of Standards and Technology (NIST)
Certification of standard reference material® 2983 :
Standard Reference Material (SRM) 2983 Inorganics in Geoduck Clam Tissue (Panopea generosa) is intended to be used for the evaluation of methods for the determination of elements, arsenic species, and proximates in this and similar matrices. A unit of SRM 2983 consists of one jar containing approximately 12 g of cryogenically homogenized frozen material. This publication documents the production, analytical methods, and statistical evaluations involved in characterizing this material.
- 18 September 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (3) , 773-785
Multi-omics characterization of NIST seafood reference materials and alternative matrix preparations
The National Institute of Standards and Technology (NIST) has prepared four seafood reference materials (RMs) for use in food safety and nutrition studies: wild-caught and aquacultured salmon (RM 8256 and RM 8257) and wild-caught and aquacultured shrimp (RM 8258 and RM 8259). These materials were characterized using genetic, metabolomic (1H-NMR, nuclear magnetic resonance and LC-HRMS/MS, liquid chromatography high-resolution tandem mass spectrometry), lipidomic, and proteomic methods to explore their use as matrix-matched, multi-omic differential materials for method development towards identifying product source and/or as quality control in untargeted omics studies. The results from experimental replicates were reproducible for each reference material and analytical method, with the most abundant features reported. Additionally, differences between the materials could be detected, where wild-caught and aquacultured seafood could be distinguished using untargeted metabolite, lipid, and protein analyses. Further processing of the fresh-frozen RMs by freeze-drying revealed the freeze-dried seafoods could still be reliably discerned. These results demonstrate the usefulness of these reference materials as tools for omics instrument validation and measurement harmonization in seafood-related studies. Furthermore, their use as differential quality control (QC) materials, regardless of preparation method, may also provide a tool for laboratories to demonstrate proficiency at discriminating between products based on source/species.
- 18 September 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 416 (3) , 773-785
Multi-omics characterization of NIST seafood reference materials and alternative matrix preparations
The National Institute of Standards and Technology (NIST) has prepared four seafood reference materials (RMs) for use in food safety and nutrition studies: wild-caught and aquacultured salmon (RM 8256 and RM 8257) and wild-caught and aquacultured shrimp (RM 8258 and RM 8259). These materials were characterized using genetic, metabolomic (1H-NMR, nuclear magnetic resonance and LC-HRMS/MS, liquid chromatography high-resolution tandem mass spectrometry), lipidomic, and proteomic methods to explore their use as matrix-matched, multi-omic differential materials for method development towards identifying product source and/or as quality control in untargeted omics studies. The results from experimental replicates were reproducible for each reference material and analytical method, with the most abundant features reported. Additionally, differences between the materials could be detected, where wild-caught and aquacultured seafood could be distinguished using untargeted metabolite, lipid, and protein analyses. Further processing of the fresh-frozen RMs by freeze-drying revealed the freeze-dried seafoods could still be reliably discerned. These results demonstrate the usefulness of these reference materials as tools for omics instrument validation and measurement harmonization in seafood-related studies. Furthermore, their use as differential quality control (QC) materials, regardless of preparation method, may also provide a tool for laboratories to demonstrate proficiency at discriminating between products based on source/species.
- Open Access
Proteomics as a Metrological Tool to Evaluate Genome Annotation Accuracy Following De Novo Genome Assembly: A Case Study Using the Atlantic Bottlenose Dolphin (Tursiops truncatus)
The last decade has witnessed dramatic improvements in whole-genome sequencing capabilities coupled to drastically decreased costs, leading to an inundation of high-quality de novo genomes. For this reason, the continued development of genome quality metrics is imperative. Using the 2016 Atlantic bottlenose dolphin NCBI RefSeq annotation and mass spectrometry-based proteomic analysis of six tissues, we confirmed 10,402 proteins from 4711 protein groups, constituting nearly one-third of the possible predicted proteins. Since the identification of larger proteins with more identified peptides implies reduced database fragmentation and improved gene annotation accuracy, we propose the metric NP10, which attempts to capture this quality improvement. The NP10 metric is calculated by first stratifying proteomic results by identifying the top decile (or 10th 10-quantile) of identified proteins based on the number of peptides per protein and then returns the median molecular weight of the resulting proteins. When using the 2016 versus 2012 Tursiops truncatus genome annotation to search this proteomic data set, there was a 21% improvement in NP10. This metric was further demonstrated by using a publicly available proteomic data set to compare human genome annotations from 2004, 2013 and 2016, which showed a 33% improvement in NP10. These results demonstrate that proteomics may be a useful metrological tool to benchmark genome accuracy, though there is a need for reference proteomic datasets across species to facilitate the evaluation of new de novo and existing genome.
Open AccessProteomics as a Metrological Tool to Evaluate Genome Annotation Accuracy Following De Novo Genome Assembly: A Case Study Using the Atlantic Bottlenose Dolphin (Tursiops truncatus)
The last decade has witnessed dramatic improvements in whole-genome sequencing capabilities coupled to drastically decreased costs, leading to an inundation of high-quality de novo genomes. For this reason, the continued development of genome quality metrics is imperative. Using the 2016 Atlantic bottlenose dolphin NCBI RefSeq annotation and mass spectrometry-based proteomic analysis of six tissues, we confirmed 10,402 proteins from 4711 protein groups, constituting nearly one-third of the possible predicted proteins. Since the identification of larger proteins with more identified peptides implies reduced database fragmentation and improved gene annotation accuracy, we propose the metric NP10, which attempts to capture this quality improvement. The NP10 metric is calculated by first stratifying proteomic results by identifying the top decile (or 10th 10-quantile) of identified proteins based on the number of peptides per protein and then returns the median molecular weight of the resulting proteins. When using the 2016 versus 2012 Tursiops truncatus genome annotation to search this proteomic data set, there was a 21% improvement in NP10. This metric was further demonstrated by using a publicly available proteomic data set to compare human genome annotations from 2004, 2013 and 2016, which showed a 33% improvement in NP10. These results demonstrate that proteomics may be a useful metrological tool to benchmark genome accuracy, though there is a need for reference proteomic datasets across species to facilitate the evaluation of new de novo and existing genome.
- 17 June 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (22) , 5447-5451
Spiking and homogenization of biological matrices for production of reference materials using cryogenic processes
Biological reference materials (RMs) are essential for quality assurance, traceability of measurement results and for method validation. When addressing new measurement questions or emerging regulatory issues, rigorous large-scale CRM production may not be time efficient or economically practical using current production methods. By amending a relatively small matrix batch with a compound(s) of interest at the homogenization step, the National Institute of Standards and Technology (NIST) can create a custom material on an “as-needed” basis and circumvent the time delay inherent in large-batch production, thereby generating a fit-for-purpose, rapid-response RM. Here, Coho salmon (Oncorhynchus kisutch) was cryohomogenized and spiked with an aquaculture antibiotic and antibiotic metabolite. The resultant material was analyzed using liquid chromatography-high resolution tandem mass spectrometry (LC-HRMS/MS) to determine the effectiveness of the amendment technique in a fresh-frozen matrix by assessing homogeneity and accuracy to the target concentration (e.g. mass fraction). Target mass fractions were achieved for both spike components, with RSDs below 5% in replicate measurements of each compound (n = 8). The stability of the spiked compounds was assessed one year post-production and mass fractions were stable, within 1–6% of the initial measurement results, indicating minimal change to the amended analyte concentrations over time. The results support this method as a promising new technique for custom, small-batch RM generation.
- 17 June 2020
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 412 (22) , 5447-5451
Spiking and homogenization of biological matrices for production of reference materials using cryogenic processes
Biological reference materials (RMs) are essential for quality assurance, traceability of measurement results and for method validation. When addressing new measurement questions or emerging regulatory issues, rigorous large-scale CRM production may not be time efficient or economically practical using current production methods. By amending a relatively small matrix batch with a compound(s) of interest at the homogenization step, the National Institute of Standards and Technology (NIST) can create a custom material on an “as-needed” basis and circumvent the time delay inherent in large-batch production, thereby generating a fit-for-purpose, rapid-response RM. Here, Coho salmon (Oncorhynchus kisutch) was cryohomogenized and spiked with an aquaculture antibiotic and antibiotic metabolite. The resultant material was analyzed using liquid chromatography-high resolution tandem mass spectrometry (LC-HRMS/MS) to determine the effectiveness of the amendment technique in a fresh-frozen matrix by assessing homogeneity and accuracy to the target concentration (e.g. mass fraction). Target mass fractions were achieved for both spike components, with RSDs below 5% in replicate measurements of each compound (n = 8). The stability of the spiked compounds was assessed one year post-production and mass fractions were stable, within 1–6% of the initial measurement results, indicating minimal change to the amended analyte concentrations over time. The results support this method as a promising new technique for custom, small-batch RM generation.
- Open Access
Characterization of a Human Liver NIST Reference Material fit for Proteomics Applications
The National Institute of Standards and Technology (NIST) is creating new, economical, qualitative reference materials and data for proteomics comparisons, benchmarking and harmonization. Here we describe a large dataset from shotgun proteomic analysis of RM 8461 Human Liver for Proteomics, a reference material being developed. Consensus identifications using multiple search engines and sample preparations demonstrate a homogeneous and fit-for-purpose material that can be incorporated into automated or manual sample preparation workflows, with the resulting data used to directly assess complete sample-to-data workflows and provide harmonization and benchmarking between laboratories and techniques. Data are available via PRIDE with identifier PXD013608.
Open AccessCharacterization of a Human Liver NIST Reference Material fit for Proteomics Applications
The National Institute of Standards and Technology (NIST) is creating new, economical, qualitative reference materials and data for proteomics comparisons, benchmarking and harmonization. Here we describe a large dataset from shotgun proteomic analysis of RM 8461 Human Liver for Proteomics, a reference material being developed. Consensus identifications using multiple search engines and sample preparations demonstrate a homogeneous and fit-for-purpose material that can be incorporated into automated or manual sample preparation workflows, with the resulting data used to directly assess complete sample-to-data workflows and provide harmonization and benchmarking between laboratories and techniques. Data are available via PRIDE with identifier PXD013608.
- Open Access
Proteomics as a metrological tool to evaluate genome annotation accuracy following de novo genome assembly: a case study using the Atlantic bottlenose dolphin ( Tursiops truncatus )
Background: The last decade has witnessed dramatic improvements in whole-genome sequencing capabilities coupled to drastically decreased costs, leading to an inundation of high-quality de novo genomes. For this reason, continued development of genome quality metrics is imperative. The current study utilized the recently updated Atlantic bottlenose dolphin ( Tursiops truncatus) genome and annotation to evaluate a proteomics-based metric of genome accuracy. Results: Proteomic analysis of six tissues provided experimental confirmation of 10 402 proteins from 4 711 protein groups, almost 1/3 of the possible predicted proteins in the genome. There was an increased median molecular weight and number of identified peptides per protein using the current T. truncatus annotation versus the previous annotation. Identification of larger proteins with more identified peptides implied reduced database fragmentation and improved gene annotation accuracy. A metric is proposed, NP10, that attempts to capture this quality improvement. When using the new T. truncatus genome there was a 21 % improvement in NP10. This metric was further demonstrated by using a publicly available proteomic data set to compare human genome annotations from 2004, 2013 and 2016, which had a 33 % improvement in NP10. Conclusions: These results demonstrate that new whole-genome sequencing techniques can rapidly generate high quality de novo genome assemblies and emphasizes the speed of advancing bioanalytical measurements in a non-model organism. Moreover, proteomics may be a useful metrological tool to benchmark genome accuracy, though there is a need for reference proteomic datasets to facilitate this utility in new de novo and existing genomes.
Open AccessProteomics as a metrological tool to evaluate genome annotation accuracy following de novo genome assembly: a case study using the Atlantic bottlenose dolphin ( Tursiops truncatus )
Background: The last decade has witnessed dramatic improvements in whole-genome sequencing capabilities coupled to drastically decreased costs, leading to an inundation of high-quality de novo genomes. For this reason, continued development of genome quality metrics is imperative. The current study utilized the recently updated Atlantic bottlenose dolphin ( Tursiops truncatus) genome and annotation to evaluate a proteomics-based metric of genome accuracy. Results: Proteomic analysis of six tissues provided experimental confirmation of 10 402 proteins from 4 711 protein groups, almost 1/3 of the possible predicted proteins in the genome. There was an increased median molecular weight and number of identified peptides per protein using the current T. truncatus annotation versus the previous annotation. Identification of larger proteins with more identified peptides implied reduced database fragmentation and improved gene annotation accuracy. A metric is proposed, NP10, that attempts to capture this quality improvement. When using the new T. truncatus genome there was a 21 % improvement in NP10. This metric was further demonstrated by using a publicly available proteomic data set to compare human genome annotations from 2004, 2013 and 2016, which had a 33 % improvement in NP10. Conclusions: These results demonstrate that new whole-genome sequencing techniques can rapidly generate high quality de novo genome assemblies and emphasizes the speed of advancing bioanalytical measurements in a non-model organism. Moreover, proteomics may be a useful metrological tool to benchmark genome accuracy, though there is a need for reference proteomic datasets to facilitate this utility in new de novo and existing genomes.