PMPhilip McGeachy

Philip McGeachy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Philip McGeachy has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of a machine learning tool to predict deep inspiration breath hold requirement for locoregional right-sided breast radiation therapy patients

    by Fletcher Barrett, Sarah Quirk, Kailyn Stenhouse, Karen Long, Michael Roumeliotis, Sangjune Lee, Roberto Souza, Philip McGeachy

    Background and purpose. This study presents machine learning (ML) models that predict if deep inspiration breath hold (DIBH) is needed based on lung dose in right-sided breast cancer patients during the initial computed tomography (CT) appointment. Materials and methods. Anatomic distances were extracted from a single-institution dataset of free breathing (FB) CT scans from locoregional right-sided breast cancer patients. Models were developed using combinations of anatomic distances and ML classification algorithms (gradient boosting, k-nearest neighbors, logistic regression, random forest, and support vector machine) and optimized over 100 iterations using stratified 5-fold cross-validation. Models were grouped by the number of anatomic distances used during development; those with the highest validation accuracy were selected as final models. Final models were compared based on their predictive ability, measurement collection efficiency, and robustness to simulated user error during measurement collection. Results. This retrospective study included 238 patients treated between 2016 and 2021. Model development ended once eight anatomic distances were included, and the validation accuracy plateaued. The best performing model used logistic regression with four anatomic distances achieving 80.5% average testing accuracy, with minimal false negatives and positives (Conclusion. Our logistic regression model using four anatomic distances provided the best balance between efficiency, robustness, and ability to predict if DIBH was needed for locoregional right-sided breast cancer patients.


  • PO-2089 Toxicity modelling in RT using Bayesian network topology optimization with simulated annealing

    by K. Stenhouse, P. McGeachy, S. Spampinato, K. Tanderup, K. Martell, S. Quirk, K. Kirchheiner, M. Schmid, M. Roumeliotis

  • Open Access

    MRI‐TRUS registration methodology for TRUS‐guided HDR prostate brachytherapy

    by Philip McGeachy, Elizabeth Watt, Siraj Husain, Kevin Martell, Pedro Martinez, Summit Sawhney, Kundan Thind

    Purpose High-dose-rate (HDR) prostate brachytherapy is an established technique for whole-gland treatment. For transrectal ultrasound (TRUS)-guided HDR prostate brachytherapy, image fusion with a magnetic resonance image (MRI) can be performed to make use of its soft-tissue contrast. The MIM treatment planning system has recently introduced image registration specifically for HDR prostate brachytherapy and has incorporated a Predictive Fusion workflow, which allows clinicians to attempt to compensate for differences in patient positioning between imaging modalities. In this study, we investigate the accuracy of the MIM algorithms for MRI-TRUS fusion, including the Predictive Fusion workflow. Materials and Methods A radiation oncologist contoured the prostate gland on both TRUS and MRI. Four registration methodologies to fuse the MRI and the TRUS images were considered: rigid registration (RR), contour-based (CB) deformable registration, Predictive Fusion followed by RR (pfRR), and Predictive Fusion followed by CB deformable registration (pfCB). Registrations were compared using the mean distance to agreement and the Dice similarity coefficient for the prostate as contoured on TRUS and the registered MRI prostate contour. Results Twenty patients treated with HDR prostate brachytherapy at our center were included in this retrospective evaluation. For the cohort, mean distance to agreement was 2.1 ± 0.8 mm, 0.60 ± 0.08 mm, 2.0 ± 0.5 mm, and 0.59 ± 0.06 mm for RR, CB, pfRR, and pfCB, respectively. Dice similarity coefficients were 0.80 ± 0.05, 0.93 ± 0.02, 0.81 ± 0.03, and 0.93 ± 0.01 for RR, CB, pfRR, and pfCB, respectively. The inclusion of the Predictive Fusion workflow did not significantly improve the quality of the registration. Conclusions The CB deformable registration algorithm in the MIM treatment planning system yielded the best geometric registration indices. MIM offers a commercial platform allowing for easier access and integration into clinical departments with the potential to play an integral role in future focal therapy applications for prostate cancer.


  • Open Access

    Verification of Acuros XB dose algorithm using 3D printed low-density phantoms for clinical photon beams

    by Rodolfo Zavan, Philip McGeachy, Joseph Madamesila, Jose-Eduardo Villarreal-Barajas, Rao Khan

    The transport‐based dose calculation algorithm Acuros XB (AXB) has been shown to accurately account for heterogeneities primarily through comparisons with Monte Carlo simulations. This study aims to provide additional experimental verification of AXB for clinically relevant flattened and unflattened beam energies in low density phantoms of the same material. Polystyrene slabs were created using a bench‐top 3D printer. Six slabs were printed at varying densities from 0.23 to 0.68 g/cm3, corresponding to different density humanoid tissues. The slabs were used to form different single and multilayer geometries. Dose was calculated with Eclipse™ AXB 11.0.31 for 6MV, 15MV flattened and 6FFF (flattening filter free) energies for field sizes of 2 × 2 and 5 × 5 cm2. EBT3 film was inserted into the phantoms, which were irradiated. Absolute dose profiles and 2D Gamma analyses were performed for 96 dose planes. For all single slab configurations and energies, absolute dose differences between the AXB calculation and film measurements remained <3% for both fields in the high‐dose region, however, larger disagreement was seen within the penumbra. For the multilayered phantom, percentage depth dose with AXB was within 5% of discrete film measurements. The Gamma index at 2%/2 mm averaged 98% in all combinations of fields, phantoms and photon energies. The transport‐based dose algorithm AXB is in good agreement with the experimental measurements for small field sizes using 6MV, 6FFF and 15MV beams adjacent to various low‐density heterogeneous media. This work provides preliminary experimental grounds to support the use of AXB for heterogeneous dose calculation purposes.


  • Open Access

    Perception and Time Effectiveness of Utilizing 3D Printer Technology to Create Rigid Bolus for Radiation Therapy

    by A. Dubey, A.M. Sharma, D. Sasaki, D. Rickey, P. McGeachy, C. Harris, J. Beaudry, J. Brown, M. Riel, M. Smyth, et al.

  • A preliminary study on the effect of modulated photon radiotherapy (XMRT) optimization for prostate cancer treatment planning

    by Philip McGeachy, Jose-Eduardo Villarreal-Barajas, Yuriy Zinchenko, Pooyan Shirvani, Rao Khan