Kailyn Stenhouse
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kailyn Stenhouse has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Michael Roumeliotis
Department of Radiation Oncology and Molecular Radiation Sciences, The Johns Hopkins University School of Medicine, Baltimore, MD
3 shared publications Philip McGeachy
Department of Physics and Astronomy, University of Calgary, Calgary, Alberta, Canada; Department of Medical Physics, Tom Baker Cancer Centre, Calgary, Alberta, Canada; Department of Oncology, University of Calgary, Calgary, Alberta, Canada
3 shared publicationsRobyn Banerjee
Department of Oncology, University of Calgary, Calgary, Alberta, Canada
3 shared publications- Svetlana Yanushkevich
University of Calgary
3 shared publications Michael Roumeliotis
Department of Physics and Astronomy, University of Calgary, Calgary, AB, Canada
2 shared publications- Philip McGeachy
Department of Medical Physics, CancerCare Manitoba, Winnipeg, MB, Canada
2 shared publications
Latest Publications
- Open Access
- 22 January 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (2) , 025013
Development of a machine learning tool to predict deep inspiration breath hold requirement for locoregional right-sided breast radiation therapy patients
Background and purpose. This study presents machine learning (ML) models that predict if deep inspiration breath hold (DIBH) is needed based on lung dose in right-sided breast cancer patients during the initial computed tomography (CT) appointment. Materials and methods. Anatomic distances were extracted from a single-institution dataset of free breathing (FB) CT scans from locoregional right-sided breast cancer patients. Models were developed using combinations of anatomic distances and ML classification algorithms (gradient boosting, k-nearest neighbors, logistic regression, random forest, and support vector machine) and optimized over 100 iterations using stratified 5-fold cross-validation. Models were grouped by the number of anatomic distances used during development; those with the highest validation accuracy were selected as final models. Final models were compared based on their predictive ability, measurement collection efficiency, and robustness to simulated user error during measurement collection. Results. This retrospective study included 238 patients treated between 2016 and 2021. Model development ended once eight anatomic distances were included, and the validation accuracy plateaued. The best performing model used logistic regression with four anatomic distances achieving 80.5% average testing accuracy, with minimal false negatives and positives (Conclusion. Our logistic regression model using four anatomic distances provided the best balance between efficiency, robustness, and ability to predict if DIBH was needed for locoregional right-sided breast cancer patients.
- 22 January 2025
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 11 (2) , 025013
Open AccessDevelopment of a machine learning tool to predict deep inspiration breath hold requirement for locoregional right-sided breast radiation therapy patients
Background and purpose. This study presents machine learning (ML) models that predict if deep inspiration breath hold (DIBH) is needed based on lung dose in right-sided breast cancer patients during the initial computed tomography (CT) appointment. Materials and methods. Anatomic distances were extracted from a single-institution dataset of free breathing (FB) CT scans from locoregional right-sided breast cancer patients. Models were developed using combinations of anatomic distances and ML classification algorithms (gradient boosting, k-nearest neighbors, logistic regression, random forest, and support vector machine) and optimized over 100 iterations using stratified 5-fold cross-validation. Models were grouped by the number of anatomic distances used during development; those with the highest validation accuracy were selected as final models. Final models were compared based on their predictive ability, measurement collection efficiency, and robustness to simulated user error during measurement collection. Results. This retrospective study included 238 patients treated between 2016 and 2021. Model development ended once eight anatomic distances were included, and the validation accuracy plateaued. The best performing model used logistic regression with four anatomic distances achieving 80.5% average testing accuracy, with minimal false negatives and positives (Conclusion. Our logistic regression model using four anatomic distances provided the best balance between efficiency, robustness, and ability to predict if DIBH was needed for locoregional right-sided breast cancer patients.
- 26 March 2024
- Published by Elsevier in Brachytherapy
- Vol. 23 (3) , 368-376
Prospective validation of a machine learning model for applicator and hybrid interstitial needle selection in high-dose-rate (HDR) cervical brachytherapy
- 26 March 2024
- Published by Elsevier in Brachytherapy
- Vol. 23 (3) , 368-376
Prospective validation of a machine learning model for applicator and hybrid interstitial needle selection in high-dose-rate (HDR) cervical brachytherapy
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S1871-S1872
PO-2089 Toxicity modelling in RT using Bayesian network topology optimization with simulated annealing
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S1871-S1872
PO-2089 Toxicity modelling in RT using Bayesian network topology optimization with simulated annealing
- Open Access
- 6 July 2021
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 11, 730375
Corrigendum: Development of a Machine Learning Model for Optimal Applicator Selection in High-Dose-Rate Cervical Brachytherapy
Corrigendum: Development of a Machine Learning Model for Optimal Applicator Selection in High-Dose-Rate Cervical Brachytherapy
- 6 July 2021
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 11, 730375
Open AccessCorrigendum: Development of a Machine Learning Model for Optimal Applicator Selection in High-Dose-Rate Cervical Brachytherapy
Corrigendum: Development of a Machine Learning Model for Optimal Applicator Selection in High-Dose-Rate Cervical Brachytherapy
- Open Access
- 5 March 2021
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 11
Development of a Machine Learning Model for Optimal Applicator Selection in High-Dose-Rate Cervical Brachytherapy
Purpose: To develop and validate a preliminary machine learning (ML) model aiding in the selection of intracavitary (IC) versus hybrid interstitial (IS) applicators for high-dose-rate (HDR) cervical brachytherapy. Methods: From a dataset of 233 treatments using IC or IS applicators, a set of geometric features of the structure set were extracted, including the volumes of OARs (bladder, rectum, sigmoid colon) and HR-CTV, proximity of OARs to the HR-CTV, mean and maximum lateral and vertical HR-CTV extent, and offset of the HR-CTV centre-of-mass from the applicator tandem axis. Feature selection using an ANOVA F-test and mutual information removed uninformative features from this set. Twelve classification algorithms were trained and tested over 100 iterations to determine the highest performing individual models through nested 5-fold cross-validation. Three models with the highest accuracy were combined using soft voting to form the final model. This model was trained and tested over 1,000 iterations, during which the relative importance of each feature in the applicator selection process was determined. Results: Feature selection indicated that the mean and maximum lateral and vertical extent, volume, and axis offset of the HR-CTV were the most informative features and were thus provided to the ML models. Relative feature importances indicated that the HR-CTV volume and mean lateral extent were most important for applicator selection. From the comparison of the individual classification algorithms, it was found that the highest performing algorithms were tree-based ensemble methods – AdaBoost Classifier (ABC), Gradient Boosting Classifier (GBC), and Random Forest Classifier (RFC). The accuracy of the individual models was compared to the voting model for 100 iterations (ABC = 91.6 ± 3.1%, GBC = 90.4 ± 4.1%, RFC = 89.5 ± 4.0%, Voting Model = 92.2 ± 1.8%) and the voting model was found to have superior accuracy. Over the final 1,000 evaluation iterations, the final voting model demonstrated a high predictive accuracy (91.5 ± 0.9%) and F1 Score (90.6 ± 1.1%). Conclusion: The presented model demonstrates high discriminative performance, highlighting the potential for utilization in informing applicator selection prospectively following further clinical validation.
- 5 March 2021
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 11
Open AccessDevelopment of a Machine Learning Model for Optimal Applicator Selection in High-Dose-Rate Cervical Brachytherapy
Purpose: To develop and validate a preliminary machine learning (ML) model aiding in the selection of intracavitary (IC) versus hybrid interstitial (IS) applicators for high-dose-rate (HDR) cervical brachytherapy. Methods: From a dataset of 233 treatments using IC or IS applicators, a set of geometric features of the structure set were extracted, including the volumes of OARs (bladder, rectum, sigmoid colon) and HR-CTV, proximity of OARs to the HR-CTV, mean and maximum lateral and vertical HR-CTV extent, and offset of the HR-CTV centre-of-mass from the applicator tandem axis. Feature selection using an ANOVA F-test and mutual information removed uninformative features from this set. Twelve classification algorithms were trained and tested over 100 iterations to determine the highest performing individual models through nested 5-fold cross-validation. Three models with the highest accuracy were combined using soft voting to form the final model. This model was trained and tested over 1,000 iterations, during which the relative importance of each feature in the applicator selection process was determined. Results: Feature selection indicated that the mean and maximum lateral and vertical extent, volume, and axis offset of the HR-CTV were the most informative features and were thus provided to the ML models. Relative feature importances indicated that the HR-CTV volume and mean lateral extent were most important for applicator selection. From the comparison of the individual classification algorithms, it was found that the highest performing algorithms were tree-based ensemble methods – AdaBoost Classifier (ABC), Gradient Boosting Classifier (GBC), and Random Forest Classifier (RFC). The accuracy of the individual models was compared to the voting model for 100 iterations (ABC = 91.6 ± 3.1%, GBC = 90.4 ± 4.1%, RFC = 89.5 ± 4.0%, Voting Model = 92.2 ± 1.8%) and the voting model was found to have superior accuracy. Over the final 1,000 evaluation iterations, the final voting model demonstrated a high predictive accuracy (91.5 ± 0.9%) and F1 Score (90.6 ± 1.1%). Conclusion: The presented model demonstrates high discriminative performance, highlighting the potential for utilization in informing applicator selection prospectively following further clinical validation.