Jennifer L. Bhatla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jennifer L. Bhatla has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Sarah Lynn Manske
Department of Radiology, Cumming School of Medicine, University of Calgary
2 shared publications - Andres Kroker
Department of Radiology, Cumming School of Medicine, University of Calgary, Canada; McCaig Institute for Bone and Joint Health, University of Calgary, Canada
1 shared publication - Carolyn A. Emery
University of Calgary
1 shared publication - Cheryl Barnabe
Cumming School of Medicine, University of Calgary
1 shared publication - Michael T. Kuczynski
McCaig Institute for Bone and Joint Health, University of Calgary, Canada; Department of Cell Biology and Anatomy, Cumming School of Medicine, University of Calgary, Canada; Department of Biomedical Engineering, Schulich School of Engineering, University of Calgary, Canada; Department of Radiology, Cumming School of Medicine, University of Calgary, Canada
1 shared publication - Peter Salat
Department of Radiology, Cumming School of Medicine, University of Calgary, Calgary AB3280 Hospital Dr NW, Calgary, Alberta, T2N 4Z6, Canada
1 shared publication
Latest Publications
- Open Access
- 7 April 2020
- Published by Springer Nature in BMC Medical Imaging
- Vol. 20 (1) , 1-10
The utility of multi-stack alignment and 3D longitudinal image registration to assess bone remodeling in rheumatoid arthritis patients from second generation HR-pQCT scans
Background: Medical imaging plays an important role in determining the progression of joint damage in rheumatoid arthritis (RA). High resolution peripheral quantitative computed tomography (HR-pQCT) is a sensitive tool capable of evaluating bone microarchitecture and erosions, and 3D rigid image registration can be used to visualize and quantify bone remodeling over time. However, patient motion during image acquisition can cause a “stack shift” artifact resulting in loss of information and reducing the number of erosions that can be analyzed using HR-pQCT. The purpose of this study was to use image registration to improve the number of useable HR-pQCT scans and to apply image-based bone remodeling assessment to the metacarpophalangeal (MCP) joints of RA patients. Methods: Ten participants with RA completed HR-pQCT scans of the 2nd and 3rd MCP joints at enrolment to the study and at a 6-month follow-up interval. At 6-months, an additional repeat scan was acquired to evaluate reliability. HR-pQCT images were acquired in three individual 1 cm acquisitions (stacks) with a 25% overlap. We completed analysis first using standard evaluation methods, and second with multi-stack registration. We assessed whether additional erosions could be evaluated after multi-stack registration. Bone remodeling analysis was completed using registration and transformation of baseline and follow-up images. We calculated the bone formation and resorption volume fractions with 6-month follow-up, and same-day repositioning as a negative control. Results: 13/57 (23%) of erosions could not be analyzed from raw images due to a stack shift artifact. All erosions could be volumetrically assessed after multi-stack registration. We observed that there was a median bone formation fraction of 2.1% and resorption fraction of 3.8% in RA patients over the course of 6 months. In contrast to the same-day rescan negative control, we observed median bone formation and resorption fractions of 0%. Conclusions: Multi-stack image registration is a useful tool to improve the number of useable scans when analyzing erosions using HR-pQCT. Further, image registration can be used to longitudinally assess bone remodeling. These methods could be implemented in future studies to provide important pathophysiological information on the progression of bone damage.
- 7 April 2020
- Published by Springer Nature in BMC Medical Imaging
- Vol. 20 (1) , 1-10
Open AccessThe utility of multi-stack alignment and 3D longitudinal image registration to assess bone remodeling in rheumatoid arthritis patients from second generation HR-pQCT scans
Background: Medical imaging plays an important role in determining the progression of joint damage in rheumatoid arthritis (RA). High resolution peripheral quantitative computed tomography (HR-pQCT) is a sensitive tool capable of evaluating bone microarchitecture and erosions, and 3D rigid image registration can be used to visualize and quantify bone remodeling over time. However, patient motion during image acquisition can cause a “stack shift” artifact resulting in loss of information and reducing the number of erosions that can be analyzed using HR-pQCT. The purpose of this study was to use image registration to improve the number of useable HR-pQCT scans and to apply image-based bone remodeling assessment to the metacarpophalangeal (MCP) joints of RA patients. Methods: Ten participants with RA completed HR-pQCT scans of the 2nd and 3rd MCP joints at enrolment to the study and at a 6-month follow-up interval. At 6-months, an additional repeat scan was acquired to evaluate reliability. HR-pQCT images were acquired in three individual 1 cm acquisitions (stacks) with a 25% overlap. We completed analysis first using standard evaluation methods, and second with multi-stack registration. We assessed whether additional erosions could be evaluated after multi-stack registration. Bone remodeling analysis was completed using registration and transformation of baseline and follow-up images. We calculated the bone formation and resorption volume fractions with 6-month follow-up, and same-day repositioning as a negative control. Results: 13/57 (23%) of erosions could not be analyzed from raw images due to a stack shift artifact. All erosions could be volumetrically assessed after multi-stack registration. We observed that there was a median bone formation fraction of 2.1% and resorption fraction of 3.8% in RA patients over the course of 6 months. In contrast to the same-day rescan negative control, we observed median bone formation and resorption fractions of 0%. Conclusions: Multi-stack image registration is a useful tool to improve the number of useable scans when analyzing erosions using HR-pQCT. Further, image registration can be used to longitudinally assess bone remodeling. These methods could be implemented in future studies to provide important pathophysiological information on the progression of bone damage.
- 1 July 2018
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 26 (7) , 929-939
Differences in subchondral bone plate and cartilage thickness between women with anterior cruciate ligament reconstructions and uninjured controls
- 1 July 2018
- Published by Elsevier in Osteoarthritis and Cartilage
- Vol. 26 (7) , 929-939
Differences in subchondral bone plate and cartilage thickness between women with anterior cruciate ligament reconstructions and uninjured controls