Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sayaka Kindaichi has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluating the Effectiveness of VR in Architectural Design Education: A Comparison Across Student Levels Using Pointing Out Mistakes in Design Plans

    by Ning Hou, Daisaku Nishina, Sayaka Kindaichi, So Sugita, Shunki Nishii

    Background: Virtual reality (VR) has attracted increasing attention in architectural design education because of its potential to support spatial cognition and embodied understanding of architectural space. Compared with conventional two-dimensional (2D) drawings and screen-based three-dimensional (3D CAD) tools, VR enables learners to experience space at a realistic scale through binocular disparity and motion parallax, which may reduce cognitive load and facilitate experiential learning. However, previous studies have mainly relied on subjective evaluations, such as questionnaires and observations, and have not sufficiently examined differences in educational effectiveness among design tools or among students with different learning levels. Objective and Methods: This study aimed to identify effective teaching tools for facilitating students’ understanding at different learning levels and to propose appropriate methods for applying VR to improve educational effectiveness. To achieve this, we proposed an objective experimental method for evaluating the effectiveness of VR in architectural design education based on students’ ability to identify incorrect content in architectural design plans. The experiment compared the performance of students using 2D drawings, 3D CAD, and VR environments and examined differences according to student grade levels (higher- and lower-year students) objectively. Results: The results revealed that both higher- and lower-year students identified more incorrect content items related to “Fitting” (such as door layouts) when using 2D drawings (finding rates were 43.8%~53.3% higher than those with 3D CAD or VR), whereas more incorrect content items related to “Furniture” size were identified when using VR (finding rates were 18.8%~56.3% higher than those with 2D drawings or 3D CAD). In addition, items related to sectional and elevation design, such as “Opening,” as well as issues concerning the size of “Space,” were identified by higher-year students regardless of the tool used. In contrast, lower-year students identified approximately twice as many of these items when using VR as when using 2D drawings. Conclusions: Based on the above results, the effectiveness of VR varied depending on both the type of design knowledge and the students’ learning levels. VR improved lower-year students’ understanding of spatial dimensions, furniture and fitting compared with conventional tools. Furthermore, VR encouraged more detailed consideration of spatial and design-related issues during architectural design tasks. These findings suggest that VR can reduce the cognitive load associated with learning architectural spatial concepts and promote experiential learning close to real spatial perception. Implications: This study supports the appropriate use of VR in architectural design education. The experimental method proposed in this study can also be used to objectively evaluate the effectiveness of educational tools other than VR before their implementation in architectural design education. Applying this method in architectural education is expected to enhance students’ awareness of architectural spatial issues and promote more comprehensive spatial understanding during the design process.

  • Open Access

    Application of a Phase-Change Material Heat Exchanger to Improve the Efficiency of Heat Pumps at Partial Loads

    by Koharu Tani, Sayaka Kindaichi, Keita Kawasaki, Daisaku Nishina

    Inverter-equipped heat pumps allow for increased energy efficiency. However, air conditioning (AC) systems often operate at low load ratios below where inverter control is effective, which reduces their energy efficiency. We developed an AC system that increases the apparent load ratio of the heat pump by using a phase-change material (PCM). Cooling and heating experiments were conducted with a PCM heat exchanger, which comprised aluminum plates and fins filled with paraffinic PCM. The result indicated a high heat transfer coefficient of >70 W/(m2·K). A simplified numerical model of the PCM heat exchanger as a lumped constant system was created based on the experiment. The calculations generally reproduced the experimental results, with root mean squared errors of 0.39 K for cooling and 0.84 K for heating, confirming their accuracy. Simulations were then conducted to evaluate the energy performance of the proposed system for the cooling season. While low load operation accounted for 39% of the total AC time for a non-PCM system, it was reduced to 2.7% for the proposed system. The proposed system demonstrated load ratios of 50–60% for most of the season, achieving an energy reduction of 11.4% owing to the improved efficiency at partial load ratios.


  • Open Access

    Energy-Saving Effects of the Intermittent Control of Pumps in Ground Source Variable Refrigerant Flow Systems with a Buffer Water Tank

    by Toya Tanaka, Sayaka Kindaichi, Keita Kawasaki, Daisaku Nishina

    Variable refrigerant flow (VRF) systems are common air-conditioning systems used in regions with moderate climates that have cooling and heating demands. Unlike typical air-source VRF systems, ground-source VRF systems require heat-source water circulation, and reducing the pumping power remains a significant problem. Herein, the intermittent pump control for circulating heat source water was achieved by installing a buffer water tank between the ground heat exchangers and VRF units. An intermittent control methodology was developed based on the indices of water transport efficiency and incorporated into a system simulation model with 72 boreholes, a cooling capacity of 252 kW, and a buffer water tank of 30 m3. Results indicated that intermittent control was achieved at heat load ratios lower than 40% as expected. This intermittent control allowed more efficient water transport with 38% lower pumping power than conventional inverter controls. Although the proposed system equipped more pumps and heat exchangers than conventional systems, it exhibited higher energy efficiencies for most measurement days than the conventional air-conditioning systems. The annual energy consumption was thus reduced by 34% and 8% compared to air-source VRF systems and conventional ground-source VRF systems, respectively.


  • Open Access

    Virtual reality space in architectural design education: Learning effect of scale feeling

    by Ning Hou, Daisaku Nishina, So Sugita, Rui Jiang, Sayaka Kindaichi, Hiroshi Oishi, Akihiro Shimizu


  • Open Access

    Reducing energy consumption of heat pumps by introducing a thermal energy storage system

    by Ryoya Hashimoto, Sayaka Kindaichi, Hongzhang Huang, Daisaku Nishina

    We proposed a short-term thermal energy storage system by applying Phase Change Materials (PCMs) in air ducts connected to an indoor air conditioning unit within a ceiling space. PCM tubes were arranged in a staggered layout in the air duct and cooled by chilled air from the air conditioning unit during “charging” mode, whereas the PCM tubes released cold energy to the room space without operation of the compressor during “discharging” mode. The charging mode allowed for an increase in the partial load ratio of the heat pump to prevent low-efficiency operation at <20% load, which can increase seasonal energy efficiency. We constructed an energy simulation program, where the heat exchange coefficient between the PCM tubes and air was varied with airflow rate and the temperature difference between the PCM and air, in accordance with results from CFD analysis. Switching between the charging and discharging modes was based on the outlet temperature (Tout) and 30% of the rated capacity of the indoor unit (Lr). The heat balance between the charging and discharging modes was improved by this change to the system control. A higher load factor and higher COP resulted in a 7.6% reduction in energy consumption.


  • Open Access

    Improved Thermal Performance of Combined Convection and Radiation Using Room Air Conditioner

    by Kyohei Aoyama, Sayaka Kindaichi, Daisaku Nishina, Hirokazu Nagaoka

    This study aims to evaluate the indoor thermal environment within a detached residence in summer by applying combined convection and radiation air conditioning system using the refrigerant gas of room air conditioners (RACs). First, field measurements were performed in a detached residence at Hiroshima, Japan, in July and August 2021. Consequently, PMV values were generally maintained within the comfortable range during air-conditioning operation. The amount of heat generated by convection (via the RAC indoor unit) Qc and that by radiation (via the radiation panel) Qr were determined as 426 and 259 W, respectively, and the overall heat generated Qtotal was determined as 685 W. Applying the CFD model, thermal environment was compared varying the ratio between Qc and Qr with a constant Qtotal of 685 W. Results showed that the synergistic operation of a RAC and a radiant panel presented more comfortable PMV values than that of a single RAC application. Furthermore, the airflow from the RAC decreased with an increase in Qr ratio, and the chilled radiant panel provided a cooling effect around the dining area, where the airflow of the RAC was inadequate, thereby improving the thermal comfort.


  • Open Access

    A STUDY ON POSSIBILITY OF USING VR SPACE IN DESIGN EDUCATION PART 1: VERIFICATION OF VR SPACE EFFECTIVENESS BY LEARNING EXPERIMENT OF SCALE FEELING

    by Ning Hou, Daisaku Nishina, So Sugita, Rui Jiang, Hiroshi Oishi, Sayaka Kindaichi, Akihiro Shimizu

    The presentation technology about architectural design has been developed in recent years. Virtual Reality as one of the newest method which was born from the modern technology, has been used at practical design. In addition, some of the universities had set up VR laboratories for design education. Compared to the traditional method using 2D drawings and models for presentation, VR will be expected to understand the space more easily without specialized knowledge, and it will be more useful for improving the designers’ ability. Therefore, in order to grasp the designers’ awareness about the applicability of VR Space, we conducted a hearing survey with 12 university professors in Chugoku region who worked in the field of architectural design or design education. According to the results, many of the professors thought “Scale feeling” was “the ability to measure the distance with the eyes”, and they had negative viewpoints about to learn “Scale feeling” in VR space, such as “It is difficult to understand the distance in VR Space” or “Drawing by hand is more useful to nurture the scale feeling than VR”. Therefore, this research was focused on the “Scale feeling”, and conducted an experiment to verify the effectiveness of VR by comparing the learning effect about “Scale feeling” in “VR Space” with “Real Space”. The procedure of this experiment, first, for grasping the original “Scale feeling” of subjects, the subjects were asked to answer the length of 15 objects in Test Space. Then, the subjects were divided into two groups to learn “Scale feeling” in two types of learning spaces. One group learned in “VR Space” and another group learned in “Real Space”. After learning, the subjects came back to “Test Space” and answered the length of 15 objects as the same manner at first. The difference between the “Answered length” and “Actual length” in “Test Space” was defined as the “Inaccuracy”. Finally, we compared the learning effects by the average and the standard deviation in “Inaccuracy” between the two groups. The degree of “Inaccuracy” reduction was similar. Therefore, the “Scale feeling” can be developed in VR space as same as Real space. Although, in “VR space”, the objects which have no actual shape have a larger standard deviation of the “Inaccuracy” than “Real Space”, we considered that it’s more difficult to grasp the distance between objects without shape in “VR space”. For the future research, we will consider in more detail based on the visual characteristics of the learning method.


  • Open Access

    Computational fluid dynamics analysis in the ductless whole-house air conditioning system

    by Rie Tasaka, Sayaka Kindaichi, Daisaku Nishina, Mitsuhiko Maeoki

    Recently, the heat load for space heating in residential houses has been reduced as airtightness, and thermal insulation performance has been improving even in moderate climate regions of Japan. In such situations, the heat load can be handled by one room air-conditioner with high energy efficiency. We report the results of computational fluid dynamics (CFD) analysis of an indoor thermal environment and the airflow distribution during the space heating operation in a ductless house air conditioning system, in which heated air from a room air conditioner installed in a thermal-insulated basement space is distributed throughout the building using air inlets on the floor in each story and open-door rooms without ductworks. To determine the adequate size and position of the air inlets on the floor in this heating system, we evaluated the air circulation performance for changes in the conditions of the air inlets by CFD analysis for a standard two-storey house model in Japan. The results suggest that the air temperature distribution is markedly different in the size and position of the air inlets on the floor. Large volumes of airflow through the openings in the building resulted in maintaining the rooms at a temperature range of 17 to 24 degrees uniformly. These results also provide information for system and building designs for effective space heating and for proper usage when choosing to open or close air inlets in the operational phase.