  • A validated SPRIGT platform for high-precision cryogenic thermometry below 5 K

    by Xiangjie Kong, Yaonan Song, Siqi Liu, Haiyang Zhang, Guoxin Li, Bo Gao, Laurent Pitre


  • Open Access

    Stability and calibration performance of standard platinum–cobalt resistance thermometers for cryogenic applications

    by Yaonan Song, Haiyang Zhang, Siqi Liu, Guoxin Li, Bo Gao, Fuhong Li, Fernando Sparasci, Laurent Pitre

    High-stability resistance thermometers are crucial for ensuring the reliable comparison and dissemination of the new kelvin, as defined by the Boltzmann constant, particularly at low temperatures. To address this, we have developed standard platinum–cobalt (PtCo) resistance thermometers (with 0.42% cobalt) specifically for low-temperature applications. These thermometers exhibit exceptional stability with deviations better than 0.2 mK at the water triple point temperature and 0.03 mK near the neon triple point. Their performance was assessed from 4.3 K to 24.5 K, performing calibrations with respect to reference rhodium-iron (RhFe) resistance thermometers. A fifth-order rational function was developed to model the resistance-temperature relationship, which shows higher fitting performance over conventional polynomial fits. This new calibration model achieves a threefold reduction in the standard deviation of the fitting residual, while using one third fewer parameters. Furthermore, long-term transport reliability was confirmed through a 1.5 year international transfer experiment involving three countries and multiple cryogenic cycles, with all measured temperature variations remaining within initial stability limits. These results demonstrate that the newly developed PtCo thermometers could provide a robust, high-accuracy solution for low-temperature metrology, thereby supporting precise calibration and international comparisons under the redefined kelvin.


  • Open Access

    Primary thermometry below 25 K: a decade of low-uncertainty measurements linked to the new kelvin

    by Bo Gao, Haiyang Zhang, Xiangjie Kong, Wenxiang Guo, Yaonan Song, Siqi Liu, Fernando Sparasci, Clement Tauzin, Jiaxi Zheng, Laurent Pitre, et al.

    In 2019, the basic unit of thermodynamic temperature, the kelvin, was redefined by fixing the value of the Boltzmann constant, opening new avenues for implementing and disseminating the kelvin with lower uncertainty, especially at temperatures below 25 K. In response, the Mise en Pratique for the definition of the kelvin (MeP-K) (2019) has recommended several primary thermometry methods, including acoustic gas thermometry (AGT), dielectric-constant gas thermometry (DCGT), refractive index gas thermometry (RIGT) and Johnson noise thermometry (JNT), as viable alternatives for realizing and disseminating the kelvin. Since the International System of Units (SI) revolution, significant progress on implementing the new kelvin has been made below 25 K. This progress indicates that primary thermometry, particularly its relative variants, can offer promising practical options for realizing and disseminating thermodynamic temperature directly linking to the new kelvin below 25 K with lower uncertainty. This is very important for metrological applications of science and industry, which require precise and accurate temperature calibrations. This article is part of the Theo Murphy meeting issue ‘The redefined kelvin: progress and prospects’.


  • Path-integral calculation of the second and third density virial coefficients of 4He

    by Wenxiang Guo, Haiyang Zhang, Mingyu Su, Bo Gao

    We present a comprehensive study of the second and third density virial coefficients, B(T) and C(T), of 4He across an extended temperature range from 1 K to 10 000 K, utilizing the path-integral Monte Carlo (PIMC) method and the most accurate interaction potentials. This work reports the first complete determination of B(T) within the PIMC framework, demonstrating excellent agreement and comparable uncertainties with results from the established phase-shift method, thus providing crucial cross-method validation. We generate a significantly extended and high-accuracy dataset for C(T), complementing existing literature values. A comprehensive uncertainty analysis quantifies contributions from both two-body and three-body potentials. The results reveal subtle differences from previous work for C(T) below 5 K, while reducing the uncertainty by approximately a factor of two in this low-temperature regime. This study provides crucial reference data to enhance the accuracy of primary standards for both temperature and pressure based on 4He.


  • Open Access

    Ultra-stable cryogenic international temperature comparator with microkelvin instability

    by Yaonan Song, Haiyang Zhang, Bo Gao, Guoxin Li, Siqi Liu, Xiangjie Kong, Laurent Pitre

    After the redefinition of the kelvin in 2019, several start-of-the-art primary gas thermometry techniques were successfully implemented at low-temperature regions. To further make a direct and reliable international comparison of thermodynamic temperature T , we have developed an ultra-stable cryogenic international temperature comparator (CITC) working from 4 K to 25 K. Based on our design and developed temperature control methods, ultra-high stable temperature was achieved with stabilities (standard deviation) better than 10 μK from 4 K to 25 K. The long-term temperature instability is 6.1 μK@4 K, 6.7 μK@5 K, 7.8 μK@13.8 K and 7.4 μK@24.6 K with a sampling time of 33.6 s. Moreover, multibridge, especially four-bridges, comparison and calibration methods were proposed to realize temperature measurements in a more precise and efficient way. The feasibility was demonstrated by using one AC bridge and three super-thermometers. The performance of CITC and the proposed methods in this work showed their great superiority to be used for temperature comparison and calibration.


  • Open Access

    Building environment control for advanced precision instruments - state-of-the-art and future perspectives

    by Xiuming Li, Haoxue Liu, Siqi Liu, Haiyang Zhang, Zongwei Han, Bo Gao, Lun Zhang, Wei Ye

    With the development of modern science, sensitive precision instrumentations, which require a reliable and ultra-high precision building environment of temperature, humidity, vibration, cleanliness, and much more, have been increasingly concerned in high-tech scenarios such as advanced metrology, scientific instrumentations, and high-tech fabrications. Nowadays, there is a lack of systematic reviews on advanced building environment control technologies for precision instruments, which have huge differences from widely-used comfort air-conditioning systems. Firstly, requirements and problems for the design in different application scenarios are discussed. Then, challenges and limitations for operation control are demonstrated. According to existing studies, the convective-radiant combined supply cooling mode may be a potential technology, and yet there are still unsolved problems including micro-vibration, multi-parameter cooperative precision control, fluctuation suppression, and dehumidification of ultra-low humidity environment. This review is expected to provide the reference for researchers, designers, and builders to design and implement building environment solutions for advanced precision instruments.


  • Open Access

    State-of-the-art comparisons of ab initio calculations of density virial coefficients for helium-4 with measurements

    by Haiyang Zhang, Xiangjie Kong, Yaonan Song, Wenjing Liu, Bo Gao

    The virial coefficients of cryogenic gases, especially helium-4 and helium-3, are playing an ever more critical role in the establishment of primary reference standards for temperature after the redefinition of the kelvin in the SI. Thus, the reliability of the values and uncertainties of these coefficients, especially those of the second, third, and even fourth density virial coefficients ( B, C and D ), has become more significant. To check the accuracy of these coefficients for helium-4 from ab initio calculations, the refractive-index gas thermometry (RIGT) method was developed, allowing for the simultaneous determination of thermodynamic temperatures and density virial coefficients. Using this technique, highly accurate experimental values of B, C and D for helium-4, as well as T – T 90 values, were obtained for the range 5 K–25 K. Direct comparisons with the ab initio calculation density virial coefficients for helium-4 were conducted, revealing excellent agreement. Furthermore, good agreements of thermodynamic temperatures T between absolute RIGT and our previous single pressure RIGT (Gao et al 2021 Metrologia 58 059501) were achieved at temperatures from 5 K to 25 K, with differences within each standard uncertainty. This further strengthens our confidence in the comparisons made in this work. It is foreseeable that the rigorously verified ab initio calculations of the density virial coefficients for helium-4 will continue to be used to improve the measurement accuracy of helium-based primary reference standards for temperature and pressure.


  • Repeatability of a primary thermometer and calibration of resistance thermometers between 5 K and 25 K

    by Haiyang Zhang, Yaonan Song, Xiangjie Kong, Bo Gao, Mark Plimmer, Laurent Pitre

    This work describes improvements to our Single Pressure Refractive-Index Gas Thermometry (SPRIGT) system (Gao et al 2020 Metrologia 57 065006), where a new experimental procedure for Constant Refractive-Index Gas Thermometry (CRIGT) was proposed and implemented, and after 2.5 years new values of T–T 90 obtained in the temperature range from 5 K to 25 K. Comparison results indicate that our SPRIGT system is robust with excellent repeatability, reliability, and stability. Not only is the uncertainty in thermodynamic temperature T still below 0.17 mK, but also good reproducibility of T 90 (temperature of the 1990 International Temperature Scale), T and T–T 90 is observed with values of 21 μK, 28 μK and 35 μK, respectively. Furthermore, we have implemented direct dissemination of thermodynamic temperature T by establishing our own thermodynamic temperature wire scale under the new International System of Units (SI) from 5 K to 25 K. The remarkable agreement further enhances our confidence on SPRIGT for implementing the redefined kelvin below 25 K, disseminating thermodynamic temperature T, and ultimately partaking in an international comparison of thermodynamic temperature via highly stable resistance thermometers.