Ki Hwan Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ki Hwan Kim has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Ui-Jung Hwang
Department of Radiation Oncology, Chungnam National University Hospital, Daejeon, Korea
5 shared publications Young Kyung Lim
Natl Canc Ctr, Proton Therapy Ctr, Goyang 10408, South Korea
3 shared publications- Byung Jun Min
Department of Radiation Oncology, Chungbuk National University Hospital, Cheongju, Korea
2 shared publications Dongho Shin
National Cancer Center
2 shared publicationsHak Soo Kim
National Cancer Center
2 shared publicationsJong Hwi Jeong
National Cancer Center
2 shared publications
Latest Publications
- Open Access
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 193-199
Approximate Modeling of the Zap-X Ⓡ Linear Accelerator Head Using mcnpx TM
Kyoung Won Jang, Heuijin Lim, Manwoo Lee, Jung Ki Kim, Kyo Chul Shin, In-Ho Jung, Sang Koo Lee, Ki-Hwan Kim, Dong Hyeok Jeong. Progress in Medical Physics 2025;36:193-9. https://doi.org/10.14316/pmp.2025.36.4.193
- 31 December 2025
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 36 (4) , 193-199
Open AccessApproximate Modeling of the Zap-X Ⓡ Linear Accelerator Head Using mcnpx TM
Kyoung Won Jang, Heuijin Lim, Manwoo Lee, Jung Ki Kim, Kyo Chul Shin, In-Ho Jung, Sang Koo Lee, Ki-Hwan Kim, Dong Hyeok Jeong. Progress in Medical Physics 2025;36:193-9. https://doi.org/10.14316/pmp.2025.36.4.193
- 1 April 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (04) , P04022
Feasibility assessment of polycrystalline CsPbI3 relative dosimeters in photon and electron beam radiotherapy
Volumetric modulated arc therapy represents the latest technology in radiotherapy. It involves continuous modification of the multi-leaf collimator spatial distribution, dose rate, and gantry rotational speed, necessitating a dosimeter with high spatial resolution and exceptional sensitivity per unit volume. In particular, cesium-based inorganic perovskites have been studied for various applications, spanning from photoconductor solar cells to radiation detectors. These perovskites are renowned for their outstanding attributes, including thermal stability, inorganic stability, and light absorption capacity. Despite such advantageous characteristics, CsPbI3 materials have only been investigated in radiodiagnostics, with limited exploration in radiotherapy. To address this gap, this study verified the viability of CsPbI3 materials, note for their outstanding radiation detection efficiency, as dosimeters capable of measuring the radiation detection performance for radiotherapy devices. The reproducibility, linearity, and percent depth dose (PDD) were evaluated under the application of photon and electron beams in linear accelerators. The reproducibility assessment revealed impressive results, with the relative standard deviation registering at 0.53%, 0.32%, and 0.38% under electron beam energies of 6, 9, and 12 MeV and 0.45%, and 0.89% under photon beam energies of 6 and 15 MV. Moreover, the linearity test revealed an R 2 value of 0.9999, indicating high linearity, at 6, 9, and 12 MeV and at 6 and 15 MV. The PDD graphs drawn for the CsPbI3 dosimeter fabricated in this study showed that the D max points were consistent. The novel CsPbI3 dosimeter demonstrated a level of detection performance that satisfied all criteria; reproducibility, linearity, and PDD. The results collectively indicated that the CsPbI3 dosimeter can be used for dosimeters in radiotherapy devices.
- 1 April 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (04) , P04022
Feasibility assessment of polycrystalline CsPbI3 relative dosimeters in photon and electron beam radiotherapy
Volumetric modulated arc therapy represents the latest technology in radiotherapy. It involves continuous modification of the multi-leaf collimator spatial distribution, dose rate, and gantry rotational speed, necessitating a dosimeter with high spatial resolution and exceptional sensitivity per unit volume. In particular, cesium-based inorganic perovskites have been studied for various applications, spanning from photoconductor solar cells to radiation detectors. These perovskites are renowned for their outstanding attributes, including thermal stability, inorganic stability, and light absorption capacity. Despite such advantageous characteristics, CsPbI3 materials have only been investigated in radiodiagnostics, with limited exploration in radiotherapy. To address this gap, this study verified the viability of CsPbI3 materials, note for their outstanding radiation detection efficiency, as dosimeters capable of measuring the radiation detection performance for radiotherapy devices. The reproducibility, linearity, and percent depth dose (PDD) were evaluated under the application of photon and electron beams in linear accelerators. The reproducibility assessment revealed impressive results, with the relative standard deviation registering at 0.53%, 0.32%, and 0.38% under electron beam energies of 6, 9, and 12 MeV and 0.45%, and 0.89% under photon beam energies of 6 and 15 MV. Moreover, the linearity test revealed an R 2 value of 0.9999, indicating high linearity, at 6, 9, and 12 MeV and at 6 and 15 MV. The PDD graphs drawn for the CsPbI3 dosimeter fabricated in this study showed that the D max points were consistent. The novel CsPbI3 dosimeter demonstrated a level of detection performance that satisfied all criteria; reproducibility, linearity, and PDD. The results collectively indicated that the CsPbI3 dosimeter can be used for dosimeters in radiotherapy devices.
- 1 July 2023
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (07) , P07021
Suitability Assessment of CsPbI_3 Dosimeter with ^192Ir Source for Brachytherapy Quality Assurance
In brachytherapy, quality assurance (QA) is a prerequisite to minimize the dose irradiation to the healthy tissues in patients during treatment, as it evaluates the accuracy of the dose applied to the patients as well as the accuracy of the position of the irradiation. Therefore, a strong emphasis has been placed on brachytherapy QA in clinical practice. This study assessed the suitability of a CsPbI3 dosimeter for the brachytherapy QA system. To verify the reliability of the unit cell sensor fabricated with CsPbI3, the electrical parameters were evaluated, after which the position dependence of the sensor was analyzed. A high level of reliability (R 2 > 0.99) and reproducibility (relative standard deviation < 1.5%) were observed. The maximal value measured at the isocenter of the sensor as the distance of the dosimeter from the irradiation source was gradually decreased. When the optimal angle was assessed, the variation was as high as 5.01 nC depending on the form of the 192Ir source. Therefore, the CsPbI3 dosimeter fabricated in this study is a suitable substitute for the conventional QA dosimeter.
- 1 July 2023
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 18 (07) , P07021
Suitability Assessment of CsPbI_3 Dosimeter with ^192Ir Source for Brachytherapy Quality Assurance
In brachytherapy, quality assurance (QA) is a prerequisite to minimize the dose irradiation to the healthy tissues in patients during treatment, as it evaluates the accuracy of the dose applied to the patients as well as the accuracy of the position of the irradiation. Therefore, a strong emphasis has been placed on brachytherapy QA in clinical practice. This study assessed the suitability of a CsPbI3 dosimeter for the brachytherapy QA system. To verify the reliability of the unit cell sensor fabricated with CsPbI3, the electrical parameters were evaluated, after which the position dependence of the sensor was analyzed. A high level of reliability (R 2 > 0.99) and reproducibility (relative standard deviation < 1.5%) were observed. The maximal value measured at the isocenter of the sensor as the distance of the dosimeter from the irradiation source was gradually decreased. When the optimal angle was assessed, the variation was as high as 5.01 nC depending on the form of the 192Ir source. Therefore, the CsPbI3 dosimeter fabricated in this study is a suitable substitute for the conventional QA dosimeter.
- Open Access
- 31 March 2023
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 34 (1) , 14
Corrigendum: Image Guided Radiation Therapy
Ui-Jung Hwang, Byung Jun Min, Meyoung Kim, Ki-Hwan Kim. Progress in Medical Physics 2023;34:14. https://doi.org/10.14316/pmp.2023.34.1.14
- 31 March 2023
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 34 (1) , 14
Open AccessCorrigendum: Image Guided Radiation Therapy
Ui-Jung Hwang, Byung Jun Min, Meyoung Kim, Ki-Hwan Kim. Progress in Medical Physics 2023;34:14. https://doi.org/10.14316/pmp.2023.34.1.14
- Open Access
- 31 December 2022
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 33 (4) , 37-52
Image Guided Radiation Therapy
Ui-Jung Hwang, Byong Jun Min, Meyoung Kim, Ki-Hwan Kim. Progress in Medical Physics 2022;33:37-52. https://doi.org/10.14316/pmp.2022.33.4.37
- 31 December 2022
- Published by Korean Society of Medical Physics in Progress in Medical Physics
- Vol. 33 (4) , 37-52
Open AccessImage Guided Radiation Therapy
Ui-Jung Hwang, Byong Jun Min, Meyoung Kim, Ki-Hwan Kim. Progress in Medical Physics 2022;33:37-52. https://doi.org/10.14316/pmp.2022.33.4.37
- Open Access
Dose Profile Modulation of Proton Minibeam for Clinical Application
The feasibility of proton minibeam radiation therapy (pMBRT) using a multislit collimator (MSC) and a scattering device was evaluated for clinical use at a clinical proton therapy facility. We fabricated, through Monte Carlo (MC) simulations, not only an MSC with a high peak-to-valley dose ratio (PVDR) at the entrance of the proton beam, to prevent radiation toxicity, but also a scattering device to modulate the PVDR in depth. The slit width and center-to-center distance of the diverging MSC were 2.5 mm and 5.0 mm at the large end, respectively, and its thickness and available field size were 100 mm and 76 × 77.5 mm2, respectively. Spatially fractionated dose distributions were measured at various depths using radiochromic EBT3 films and also tested on bacterial cells. MC simulation showed that the thicker the MSC, the higher the PVDR at the phantom surface. Dosimetric evaluations showed that lateral dose profiles varied according to the scatterer’s thickness, and the depths satisfying PVDR = 1.1 moved toward the surface as their thickness increased. The response of the bacterial cells to the proton minibeams’ depth was also established, in a manner similar to the dosimetric pattern. Conclusively, these results strongly suggest that pMBRT can be implemented in clinical centers by using MSC and scatterers.
Open AccessDose Profile Modulation of Proton Minibeam for Clinical Application
The feasibility of proton minibeam radiation therapy (pMBRT) using a multislit collimator (MSC) and a scattering device was evaluated for clinical use at a clinical proton therapy facility. We fabricated, through Monte Carlo (MC) simulations, not only an MSC with a high peak-to-valley dose ratio (PVDR) at the entrance of the proton beam, to prevent radiation toxicity, but also a scattering device to modulate the PVDR in depth. The slit width and center-to-center distance of the diverging MSC were 2.5 mm and 5.0 mm at the large end, respectively, and its thickness and available field size were 100 mm and 76 × 77.5 mm2, respectively. Spatially fractionated dose distributions were measured at various depths using radiochromic EBT3 films and also tested on bacterial cells. MC simulation showed that the thicker the MSC, the higher the PVDR at the phantom surface. Dosimetric evaluations showed that lateral dose profiles varied according to the scatterer’s thickness, and the depths satisfying PVDR = 1.1 moved toward the surface as their thickness increased. The response of the bacterial cells to the proton minibeams’ depth was also established, in a manner similar to the dosimetric pattern. Conclusively, these results strongly suggest that pMBRT can be implemented in clinical centers by using MSC and scatterers.
- 22 February 2021
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 78 (6) , 523-534
Feasibility study of radiophotoluminescent glass dosimeter for in vivo dosimetry in external photon beam radiotherapy
- 22 February 2021
- Published by Springer Nature in Journal of the Korean Physical Society
- Vol. 78 (6) , 523-534
Feasibility study of radiophotoluminescent glass dosimeter for in vivo dosimetry in external photon beam radiotherapy
- 13 July 2020
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 77 (1) , 94-101
Considerations in Selecting a Fitting a Function for Film Dosimetry in Radiation Therapy
- 13 July 2020
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 77 (1) , 94-101
Considerations in Selecting a Fitting a Function for Film Dosimetry in Radiation Therapy
- Open Access
- 15 May 2018
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 72 (10) , 1271
Erratum to: Depth Dose Measurement using a Scintillating Fiber Optic Dosimeter for Proton Therapy Beam of the Passive-Scattering Mode Having Range Modulator Wheel
The affiliation of Ui-Jung Hwang was incorrect. It should be corrected as “Department of Radiation Oncology, Chungnam National University Hospital, Daejeon 35015, Korea”.
- 15 May 2018
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 72 (10) , 1271
Open AccessErratum to: Depth Dose Measurement using a Scintillating Fiber Optic Dosimeter for Proton Therapy Beam of the Passive-Scattering Mode Having Range Modulator Wheel
The affiliation of Ui-Jung Hwang was incorrect. It should be corrected as “Department of Radiation Oncology, Chungnam National University Hospital, Daejeon 35015, Korea”.
- 28 April 2018
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 72 (9) , 1025-1032
Depth Dose Measurement using a Scintillating Fiber Optic Dosimeter for Proton Therapy Beam of the Passive-Scattering Mode Having Range Modulator Wheel
To apply a scintillating fiber dosimetry system to measure the range of a proton therapy beam, a new method was proposed to correct for the quenching effect on measuring an spread out Bragg peak (SOBP) proton beam whose range is modulated by a range modulator wheel. The scintillating fiber dosimetry system was composed of a plastic scintillating fiber (BCF-12), optical fiber (SH 2001), photo multiplier tube (H7546), and data acquisition system (PXI6221 and SCC68). The proton beam was generated by a cyclotron (Proteus-235) in the National Cancer Center in Korea. It operated in the double-scattering mode and the spread out of the Bragg peak was achieved by a spinning range modulation wheel. Bragg peak beams and SOBP beams of various ranges were measured, corrected, and compared to the ion chamber data. For the Bragg peak beam, quenching equation was used to correct the quenching effect. On the proposed process of correcting SOBP beams, the measured data using a scintillating fiber were separated by the Bragg peaks that the SOBP beam contained, and then recomposed again to reconstruct an SOBP after correcting for each Bragg peak. The measured depth-dose curve for the single Bragg peak beam was well corrected by using a simple quenching equation. Correction for SOBP beam was conducted with a newly proposed method. The corrected SOBP signal was in accordance with the results measured with an ion chamber. We propose a new method to correct for the SOBP beam from the quenching effect in a scintillating fiber dosimetry system. This method can be applied to other scintillator dosimetry for radiation beams in which the quenching effect is shown in the scintillator.
- 28 April 2018
- Published by Korean Physical Society in Journal of the Korean Physical Society
- Vol. 72 (9) , 1025-1032
Depth Dose Measurement using a Scintillating Fiber Optic Dosimeter for Proton Therapy Beam of the Passive-Scattering Mode Having Range Modulator Wheel
To apply a scintillating fiber dosimetry system to measure the range of a proton therapy beam, a new method was proposed to correct for the quenching effect on measuring an spread out Bragg peak (SOBP) proton beam whose range is modulated by a range modulator wheel. The scintillating fiber dosimetry system was composed of a plastic scintillating fiber (BCF-12), optical fiber (SH 2001), photo multiplier tube (H7546), and data acquisition system (PXI6221 and SCC68). The proton beam was generated by a cyclotron (Proteus-235) in the National Cancer Center in Korea. It operated in the double-scattering mode and the spread out of the Bragg peak was achieved by a spinning range modulation wheel. Bragg peak beams and SOBP beams of various ranges were measured, corrected, and compared to the ion chamber data. For the Bragg peak beam, quenching equation was used to correct the quenching effect. On the proposed process of correcting SOBP beams, the measured data using a scintillating fiber were separated by the Bragg peaks that the SOBP beam contained, and then recomposed again to reconstruct an SOBP after correcting for each Bragg peak. The measured depth-dose curve for the single Bragg peak beam was well corrected by using a simple quenching equation. Correction for SOBP beam was conducted with a newly proposed method. The corrected SOBP signal was in accordance with the results measured with an ion chamber. We propose a new method to correct for the SOBP beam from the quenching effect in a scintillating fiber dosimetry system. This method can be applied to other scintillator dosimetry for radiation beams in which the quenching effect is shown in the scintillator.