Feasibility assessment of polycrystalline CsPbI3 relative dosimeters in photon and electron beam radiotherapy
- 1 April 2024
- journal article
- research article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (04) , P04022
Abstract
Volumetric modulated arc therapy represents the latest technology in radiotherapy. It involves continuous modification of the multi-leaf collimator spatial distribution, dose rate, and gantry rotational speed, necessitating a dosimeter with high spatial resolution and exceptional sensitivity per unit volume. In particular, cesium-based inorganic perovskites have been studied for various applications, spanning from photoconductor solar cells to radiation detectors. These perovskites are renowned for their outstanding attributes, including thermal stability, inorganic stability, and light absorption capacity. Despite such advantageous characteristics, CsPbI3 materials have only been investigated in radiodiagnostics, with limited exploration in radiotherapy. To address this gap, this study verified the viability of CsPbI3 materials, note for their outstanding radiation detection efficiency, as dosimeters capable of measuring the radiation detection performance for radiotherapy devices. The reproducibility, linearity, and percent depth dose (PDD) were evaluated under the application of photon and electron beams in linear accelerators. The reproducibility assessment revealed impressive results, with the relative standard deviation registering at 0.53%, 0.32%, and 0.38% under electron beam energies of 6, 9, and 12 MeV and 0.45%, and 0.89% under photon beam energies of 6 and 15 MV. Moreover, the linearity test revealed an R 2 value of 0.9999, indicating high linearity, at 6, 9, and 12 MeV and at 6 and 15 MV. The PDD graphs drawn for the CsPbI3 dosimeter fabricated in this study showed that the D max points were consistent. The novel CsPbI3 dosimeter demonstrated a level of detection performance that satisfied all criteria; reproducibility, linearity, and PDD. The results collectively indicated that the CsPbI3 dosimeter can be used for dosimeters in radiotherapy devices.Keywords
This publication has 18 references indexed in Scilit:
- A Versatile Molten‐Salt Induction Strategy to Achieve Efficient CsPbI3 Perovskite Solar Cells with a High Open‐Circuit Voltage >1.2 VAdvanced Materials, 2022
- Perovskite semiconductors for ionizing radiation detectionEcoMat, 2022
- Verification of patient specific quality assurance system for volumetric modulated arc therapy (VMAT)Health and Technology, 2022
- Orthorhombic Non‐Perovskite CsPbI3 Microwires for Stable High‐Resolution X‐Ray DetectorsAdvanced Optical Materials, 2022
- Survey of patient‐specific quality assurance practice for IMRT and VMATJournal of Applied Clinical Medical Physics, 2021
- Patient-specific radiotherapy quality assurance for estimating actual treatment doseMedical Dosimetry, 2021
- Halide perovskites: A dark horse for direct X‐ray imagingEcoMat, 2020
- Halide Perovskite, a Potential Scintillator for X‐Ray DetectionSmall Methods, 2020
- Fabrication of Efficient and Stable CsPbI3 Perovskite Solar Cells through Cation Exchange ProcessAdvanced Energy Materials, 2019
- Machine Learning for Patient-Specific Quality Assurance of VMAT: Prediction and Classification AccuracyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2019