MPMarco Pagliazzi

Marco Pagliazzi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marco Pagliazzi has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    “hDOS”: An automated hybrid diffuse optical device for real-time non-invasive tissue monitoring—precision and in vivo validation

    by Marta Zanoletti, M. Atif Yaqub, Lorenzo Cortese, Mauro Buttafava, Jacqueline Martínez García, Caterina Amendola, Talyta Carteano, Lorenzo Frabasile, Diego Sanoja Garcia, Claudia Nunzia Guadagno, et al.

    Significance: A new platform/device is presented that advances hybrid diffuse optical monitors closed to clinical practice, bridging the gap between research-grade optical systems and practical bedside applications. Traditional devices often lack automation, multi-parameter functionality, and operator independence, hence, limiting their usability in demanding clinical environments. By offering automation, user-friendly operation, and overcoming the typical limitations of continuous-wave near-infrared spectroscopy, the hybrid diffuse optical platform (hDOS) provides a more accurate and reliable assessment of both oxygenation and perfusion. This innovation is particularly valuable for monitoring critically ill patients, where precise real-time measurements can directly influence patient management and outcomes. Aim: To design, validate, and characterize the platform hDOS that integrates time-domain near-infrared spectroscopy, diffuse correlation spectroscopy, and a pulse oximeter with an automated vascular occlusion test (VOT). The platform aims to support continuous monitoring and the assessment of peripheral microvascular, and metabolic functions in both clinical and field settings. Approach: The validation strategy for the hDOS device follows a comprehensive approach that goes beyond conventional optical performance assessments. Rather than solely verifying fundamental system parameters, the evaluation comprises of real-world usability, operator and patient safety, and clinical implementation. The device’s precision and usability were rigorously tested in vivo through test-retest measurements and comparisons with a commercially available device (INVOS 5100C). This was subsequently followed by a seven-month clinical evaluation at Parc Taulí Hospital Universitari. Results: The device underwent extensive validation, accumulating over 200 hours of usage across approximately 150 measurement sessions. The hDOS device exhibited two-fold lower inter-subject and intra-subject variability in baseline tissue oxygen saturation compared to the INVOS 5100C. Furthermore, during a a vascular occlusion challenge, statistically significant differences were observed between the two systems across all extracted parameters. Finally, as a proof of concept, hDOS successfully detected differences in the microvasculature between a general mixed ICU patient cohort ( n = 100) and a healthy control group ( n = 37). Conclusions: Overall, hDOS device has performed well in both bench-top and realistic clinical applications on patients in vivo . hDOS device provides a unique combination of parameters, available for the first time in a fully automated, self-contained platform.

  • Open Access

    Performance assessment of laser sources for time-domain diffuse correlation spectroscopy

    by Saeed Samaei, Lorenzo Colombo, Dawid Borycki, Marco Pagliazzi, Turgut Durduran, Piotr Sawosz, Stanislaw Wojtkiewicz, Davide Contini, Alessandro Torricelli, Antonio Pifferi, et al.

    Time-domain diffuse correlation spectroscopy (TD-DCS) is an emerging optical technique that enables noninvasive measurement of microvascular blood flow with photon path-length resolution. In TD-DCS, a picosecond pulsed laser with a long coherence length, adequate illumination power, and narrow instrument response function (IRF) is required, and satisfying all these features is challenging. To this purpose, in this study we characterized the performance of three different laser sources for TD-DCS. First, the sources were evaluated based on their emission spectrum and IRF. Then, we compared the signal-to-noise ratio and the sensitivity to velocity changes of scattering particles in a series of phantom measurements. We also compared the results for in vivo measurements, performing an arterial occlusion protocol on the forearm of three adult subjects. Overall, each laser has the potential to be successfully used both for laboratory and clinical applications. However, we found that the effects caused by the IRF are more significant than the effect of a limited temporal coherence.


  • Open Access

    Recipes for diffuse correlation spectroscopy instrument design using commonly utilized hardware based on targets for signal-to-noise ratio and precision

    by Lorenzo Cortese, Giuseppe Lo Presti, Marco Pagliazzi, Davide Contini, Alberto Dalla Mora, Hamid Dehghani, Fabio Ferri, Jonas B. Fischer, Martina Giovannella, Fabrizio Martelli, et al.

    Over the recent years, a typical implementation of diffuse correlation spectroscopy (DCS) instrumentation has been adapted widely. However, there are no detailed and accepted recipes for designing such instrumentation to meet pre-defined signal-to-noise ratio (SNR) and precision targets. These require specific attention due to the subtleties of the DCS signals. Here, DCS experiments have been performed using liquid tissue simulating phantoms to study the effect of the detected photon count-rate, the number of parallel detection channels and the measurement duration on the precision and SNR to suggest scaling relations to be utilized for device design.


  • Open Access

    In vivo time-domain diffuse correlation spectroscopy at 1 μm

    by Lorenzo Colombo, Marco Pagliazzi, Sanathana Konugolu Venkata Sekar, Davide Contini, Turgut Durduran, Antonio Pifferi

    SPIE Digital Library Proceedings

  • Open Access

    Time resolved speckle contrast optical spectroscopy at quasi-null source-detector separation for non-invasive measurement of microvascular blood flow

    by Marco Pagliazzi, Lorenzo Colombo, Ernesto E. Vidal-Rosas, Tanja Dragojević, Veronika Parfentyeva, Joseph P. Culver, Sanathana Konugolu Venkata Sekar, Laura Di Sieno, Davide Contini, Alessandro Torricelli, et al.

    Time (or path length) resolved speckle contrast optical spectroscopy (TD-SCOS) at quasi-null (2.85 mm) source-detector separation was developed and demonstrated. The method was illustrated by in vivo studies on the forearm muscle of an adult subject. The results have shown that selecting longer photon path lengths results in higher hyperemic blood flow change and a faster return to baseline by a factor of two after arterial cuff occlusion when compared to SCOS without time resolution. This indicates higher sensitivity to the deeper muscle tissue. In the long run, this approach may allow the use of simpler and cheaper detector arrays compared to time resolved diffuse correlation spectroscopy that are based on readily available technologies. Hence, TD-SCOS may increase the performance and decrease cost of devices for continuous non-invasive, deep tissue blood flow monitoring.


  • Open Access

    Coherent fluctuations in time-domain diffuse optics

    by Lorenzo Colombo, Saeed Samaei, Pranav Lanka, Daniele Ancora, Marco Pagliazzi, Turgut Durduran, Piotr Sawosz, Adam Liebert, Antonio Pifferi

    Near infrared light pulses, multiply scattered by random media, carry useful information regarding the sample key constituents and their microstructures. Usually, the photon diffusion equation is used to interpret the data, which neglects any interference effect in the detected light fields. However, in several experimental techniques, such as diffuse correlation spectroscopy or laser speckle flowmetry, the effect of light coherence is exploited to retrieve the information on the sample dynamical properties. Here, using an actively mode-locked Ti:Sapphire laser, we report the observation of temporal fluctuations in the diffused light pulse, which cannot be described by the diffusion theory. We demonstrate the sensitivity of these fluctuations on the sample dynamical properties and on the number of detected coherence areas (i.e., speckles). In addition, after interpreting the effect as a time-resolved speckle pattern, we propose a simple statistical method for its quantification. The proposed approach may enable the simultaneous monitoring of the static (absorption and scattering coefficients) and dynamical (Brownian diffusion coefficient) properties of the sample, and also provide physical insight on the propagation of optical waves in random media.


  • In vivo time-domain diffuse correlation spectroscopy above the water absorption peak

    by Lorenzo Colombo, Marco Pagliazzi, Sanathana Konugolu Venkata Sekar, Davide Contini, Turgut Durduran, Antonio Pifferi

    Time-domain diffuse correlation spectroscopy (TD-DCS) is a newly emerging optical technique that exploits pulsed, yet coherent light to non-invasively resolve the blood flow in depth. In this work, we have explored TD-DCS at longer wavelengths compared to those previously used in literature (i.e., 750–850 nm). The measurements were performed using a custom-made titanium-sapphire mode-locked laser, operating at 1000 nm, and an InGaAs photomultiplier as a detector. Tissue-mimicking phantoms and in vivo measurements during arterial arm cuff occlusion in n = 4 adult volunteers were performed to demonstrate the proof of concept. We obtained a good signal-to-noise ratio, following the hemodynamics continuously with a relatively fast (1 Hz) sampling rate. In all the experiments, the auto-correlation functions show a decay rate approximately five-fold slower compared to shorter wavelengths. This work demonstrates the feasibility of in vivo TD-DCS in this spectral region and its potentiality for biomedical applications.


  • Open Access

    Effects of the instrument response function and the gate width in time-domain diffuse correlation spectroscopy: model and validations

    by Lorenzo Colombo, Marco Pagliazzi, Sanathana Konugolu Venkata Sekar, Davide Contini, Alberto Dalla Mora, Lorenzo Spinelli, Alessandro Torricelli, Turgut Durduran, Antonio Pifferi

    Diffuse correlation spectroscopy (DCS) is an optical technique that measures the scatterer’s motion in diffusive media, traditionally, by injecting a coherent continuous wave (CW) laser beam in a turbid sample and by characterizing the speckle fluctuations by their intensity autocorrelation function. Afterward, using a correlation diffusion model, the motion of red blood cells in the microvasculature is estimated, which has been shown to be proportional to local blood flow (BF).1 The technique is an advancement over diffuse wave spectroscopy,2 which is widely used in the study of nonbiological media. Over the last two decades, DCS has emerged as a promising technique for many clinical applications since it provides a direct measure of BF in deep (>1  cm) tissues.


  • Open Access

    BabyLux device: a diffuse optical system integrating diffuse correlation spectroscopy and time-resolved near-infrared spectroscopy for the neuromonitoring of the premature newborn brain

    by Martina Giovannella, Davide Contini, Marco Pagliazzi, Antonio Pifferi, Lorenzo Spinelli, Rainer Erdmann, Roger Donat, Ignacio Rocchetti, Matthias Rehberger, Niels König, et al.

    Preterm birth is a major and widespread healthcare issue involving 15 million babies every year.1 It is a major cause of death in children under the age of 5, and a high percentage of the survivors suffer neurological disabilities.2 The neurodevelopment of preterm newborns can be negatively affected by hemodynamic instabilities during the first hours and days of life, where brain lesions are often developed.3,4 It is hypothesized that brain-oriented intensive care of the preterm newborns would minimize these problems, but, to be effective, it would require the possibility to monitor the cerebral well-being at the cot-side in real time. Unfortunately, such a technology is still lacking in the daily clinical care.


  • Accuracy and precision of tissue optical properties and hemodynamic parameters estimated by the BabyLux device: a hybrid time-resolved near-infrared and diffuse correlation spectroscopy neuro-monitor

    by Martina Giovannella, Lorenzo Spinelli, Marco Pagliazzi, Davide Contini, Gorm Greisen, Udo M. Weigel, Alessandro Torricelli, Turgut Durduran

    We have investigated the accuracy and precision of “the BabyLux device”, a hybrid time-resolved near-infrared (TRS) and diffuse correlation spectroscopy (DCS) neuro-monitor for the pre-term infant. Numerical data with realistic noise were simulated and analyzed using the BabyLux device as a reference system and different experimental and analysis parameters. The results describe the limits for the precision and the accuracy to be expected. The dependence of these limits on different experimental conditions and choices of the analysis method is also described. Experiments demonstrate comparable values for precision with respect to the simulation results.