LCLorenzo Colombo

Lorenzo Colombo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Lorenzo Colombo has a total of 80 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Multi-laboratory performance assessment of diffuse optics instruments: the BitMap exercise

    by Pranav Lanka, Lin Yang, David Orive-Miguel, Joshua Deepak Veesa, Susanna Tagliabue, Aleh Sudakou, Saeed Samaei, Mario Forcione, Zuzana Kovacsova, Anurag Behera, et al.

    Diffuse optics (DO) encompasses a range of photonics tools based on the study of random photon migration in highly scattering media—biological tissues in particular. Due to its unique features, DO is emerging as a powerful means for clinical or homecare diagnostics.1 The basic physics of DO is related to the detection of temporal or spatial alteration in photon distribution re-emitted on the tissue surface.2 Due to the low power (typically few mW) of injected near-infrared light (600- to 1100-nm range), DO is inherently noninvasive. The photon temporal (or spatial) distribution carries information on the absorption—ultimately related to tissue chemical composition, such as water, lipid, collagen content, oxy- and deoxy-hemoglobin concentration, cytochrome c-oxidase3—and scattering properties—linked to tissue microstructure. Further, DO is one of the few noninvasive modalities capable of providing functional information, e.g., brain or muscle activation.4 It can be operated noncontact through remote light illumination and collection.5 It explores the tissue well below the skin at depths of up to 2 to 4 cm. It can provide quantitative operator-independent assessment of the tissue status, such as hemoglobin oxygenation level in the brain. Finally, it is highly scalable, sharing the same technology from large clinical tomographic systems down to wearable devices or homecare appliances.6 For all these aspects, DO is attracting more and more interest in many fields, such as monitoring vital signs like brain oxygenation in critical care or during interventions,7 tumor diagnostics as for breast cancer,8 investigating the impact of lifestyle and nutrition on our body,9 or other fields such as neuroscience and psychology,10 sports, and leisure.11 Even further, the operator independence, the depth sensitivity, and the scalability in addition to noninvasiveness make this option attractive for telemedicine and homecare of patients remotely.


  • Superconducting nanowire detectors for in vivo time-domain diffuse correlation spectroscopy: system and validations

    by Lorenzo Colombo, Veronika Parfentyeva, Pranav Lanka, Marco Pagliazzi, Annalisa Brodu, Niels Noordzij, Mirco Kolarczik, Alberto Dalla Mora, Davide Contini, Alessandro Torricelli, et al.

    We present a time-domain diffuse correlation spectroscopy system based on superconducting nanowire single-photon detectors, reporting its architecture and a characterization with phantom and in vivo experiments.

  • Open Access

    Performance assessment of laser sources for time-domain diffuse correlation spectroscopy

    by Saeed Samaei, Lorenzo Colombo, Dawid Borycki, Marco Pagliazzi, Turgut Durduran, Piotr Sawosz, Stanislaw Wojtkiewicz, Davide Contini, Alessandro Torricelli, Antonio Pifferi, et al.

    Time-domain diffuse correlation spectroscopy (TD-DCS) is an emerging optical technique that enables noninvasive measurement of microvascular blood flow with photon path-length resolution. In TD-DCS, a picosecond pulsed laser with a long coherence length, adequate illumination power, and narrow instrument response function (IRF) is required, and satisfying all these features is challenging. To this purpose, in this study we characterized the performance of three different laser sources for TD-DCS. First, the sources were evaluated based on their emission spectrum and IRF. Then, we compared the signal-to-noise ratio and the sensitivity to velocity changes of scattering particles in a series of phantom measurements. We also compared the results for in vivo measurements, performing an arterial occlusion protocol on the forearm of three adult subjects. Overall, each laser has the potential to be successfully used both for laboratory and clinical applications. However, we found that the effects caused by the IRF are more significant than the effect of a limited temporal coherence.


  • Open Access

    In vivo time-domain diffuse correlation spectroscopy at 1 μm

    by Lorenzo Colombo, Marco Pagliazzi, Sanathana Konugolu Venkata Sekar, Davide Contini, Turgut Durduran, Antonio Pifferi

    SPIE Digital Library Proceedings

  • Open Access

    Time resolved speckle contrast optical spectroscopy at quasi-null source-detector separation for non-invasive measurement of microvascular blood flow

    by Marco Pagliazzi, Lorenzo Colombo, Ernesto E. Vidal-Rosas, Tanja Dragojević, Veronika Parfentyeva, Joseph P. Culver, Sanathana Konugolu Venkata Sekar, Laura Di Sieno, Davide Contini, Alessandro Torricelli, et al.

    Time (or path length) resolved speckle contrast optical spectroscopy (TD-SCOS) at quasi-null (2.85 mm) source-detector separation was developed and demonstrated. The method was illustrated by in vivo studies on the forearm muscle of an adult subject. The results have shown that selecting longer photon path lengths results in higher hyperemic blood flow change and a faster return to baseline by a factor of two after arterial cuff occlusion when compared to SCOS without time resolution. This indicates higher sensitivity to the deeper muscle tissue. In the long run, this approach may allow the use of simpler and cheaper detector arrays compared to time resolved diffuse correlation spectroscopy that are based on readily available technologies. Hence, TD-SCOS may increase the performance and decrease cost of devices for continuous non-invasive, deep tissue blood flow monitoring.


  • Open Access

    Coherent fluctuations in time-domain diffuse optics

    by Lorenzo Colombo, Saeed Samaei, Pranav Lanka, Daniele Ancora, Marco Pagliazzi, Turgut Durduran, Piotr Sawosz, Adam Liebert, Antonio Pifferi

    Near infrared light pulses, multiply scattered by random media, carry useful information regarding the sample key constituents and their microstructures. Usually, the photon diffusion equation is used to interpret the data, which neglects any interference effect in the detected light fields. However, in several experimental techniques, such as diffuse correlation spectroscopy or laser speckle flowmetry, the effect of light coherence is exploited to retrieve the information on the sample dynamical properties. Here, using an actively mode-locked Ti:Sapphire laser, we report the observation of temporal fluctuations in the diffused light pulse, which cannot be described by the diffusion theory. We demonstrate the sensitivity of these fluctuations on the sample dynamical properties and on the number of detected coherence areas (i.e., speckles). In addition, after interpreting the effect as a time-resolved speckle pattern, we propose a simple statistical method for its quantification. The proposed approach may enable the simultaneous monitoring of the static (absorption and scattering coefficients) and dynamical (Brownian diffusion coefficient) properties of the sample, and also provide physical insight on the propagation of optical waves in random media.


  • In vivo time-domain diffuse correlation spectroscopy above the water absorption peak

    by Lorenzo Colombo, Marco Pagliazzi, Sanathana Konugolu Venkata Sekar, Davide Contini, Turgut Durduran, Antonio Pifferi

    Time-domain diffuse correlation spectroscopy (TD-DCS) is a newly emerging optical technique that exploits pulsed, yet coherent light to non-invasively resolve the blood flow in depth. In this work, we have explored TD-DCS at longer wavelengths compared to those previously used in literature (i.e., 750–850 nm). The measurements were performed using a custom-made titanium-sapphire mode-locked laser, operating at 1000 nm, and an InGaAs photomultiplier as a detector. Tissue-mimicking phantoms and in vivo measurements during arterial arm cuff occlusion in n = 4 adult volunteers were performed to demonstrate the proof of concept. We obtained a good signal-to-noise ratio, following the hemodynamics continuously with a relatively fast (1 Hz) sampling rate. In all the experiments, the auto-correlation functions show a decay rate approximately five-fold slower compared to shorter wavelengths. This work demonstrates the feasibility of in vivo TD-DCS in this spectral region and its potentiality for biomedical applications.


  • In vivo time-domain diffuse correlation spectroscopy beyond the water absorption peak

    by L. Colombo, M. Pagliazzi, S. Konugolu Venkata Sekar, D. Contini, T. Durduran, A. Pifferi

    Time-domain diffuse correlation spectroscopy is an emerging method for depth resolved blood flow measurements. To improve depth sensitivity and SNR, we explore this technique at wavelengths beyond water peak, with phantoms and in vivo experiments.

  • Open Access

    Effects of the instrument response function and the gate width in time-domain diffuse correlation spectroscopy: model and validations

    by Lorenzo Colombo, Marco Pagliazzi, Sanathana Konugolu Venkata Sekar, Davide Contini, Alberto Dalla Mora, Lorenzo Spinelli, Alessandro Torricelli, Turgut Durduran, Antonio Pifferi

    Diffuse correlation spectroscopy (DCS) is an optical technique that measures the scatterer’s motion in diffusive media, traditionally, by injecting a coherent continuous wave (CW) laser beam in a turbid sample and by characterizing the speckle fluctuations by their intensity autocorrelation function. Afterward, using a correlation diffusion model, the motion of red blood cells in the microvasculature is estimated, which has been shown to be proportional to local blood flow (BF).1 The technique is an advancement over diffuse wave spectroscopy,2 which is widely used in the study of nonbiological media. Over the last two decades, DCS has emerged as a promising technique for many clinical applications since it provides a direct measure of BF in deep (>1  cm) tissues.


  • Open Access

    In vivo time-gated diffuse correlation spectroscopy at quasi-null source-detector separation

    by M. Pagliazzi, S. Konugolu Venkata Sekar, L. Di Sieno, L. Colombo, T. Durduran, D. Contini, A. Torricelli, A. Pifferi, A. Dalla Mora

    We demonstrate time domain diffuse correlation spectroscopy at quasi-null source-detector separation by using a fast time-gated single-photon avalanche diode without the need of time-tagging electronics. This approach allows for increased photon collection, simplified real-time instrumentation, and reduced probe dimensions. Depth discriminating, quasi-null distance measurement of blood flow in a human subject is presented. We envision the miniaturization and integration of matrices of optical sensors of increased spatial resolution and the enhancement of the contrast of local blood flow changes.