SCShi Chen

Shi Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shi Chen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Composite Model Predictive Control Strategy for Triple-Active-Bridge-Based MMDTC-PET with Enhanced Disturbance Resilience

    by Xuefeng Ge, Qi Zhou, Xin Fang, Shi Chen

    To address the delayed dynamic response and susceptibility to overcurrent surges of the triple-active-bridge (TAB)-based modular multilevel DC-link T-type converter power electronic transformer (MMDTC-PET) under load step transients, this paper proposes a composite model predictive control (MPC) strategy to enhance the system’s disturbance rejection capability. The proposed strategy adopts a hierarchical control architecture comprising a proportional-integral (PI) outer power loop and an MPC inner loop. To tackle the heavy computational burden caused by multi-port coupling, dimensionality reduction is performed by equating the phase-shift ratios of the two primary-side ports of the TAB, which effectively mitigates the computational cost. Furthermore, a dynamic overcurrent hard-constraint penalty term and a control-effort smoothing term are incorporated into the multi-objective cost function. This not only achieves steady-state error-free tracking of the output voltage but also enhances physical operational safety under complex conditions at the algorithmic level. Comparative simulation results under various operating conditions demonstrate that, compared with the traditional PI-based phase-shift control, the proposed strategy exhibits a faster dynamic response under load step conditions. Moreover, it suppresses transient power overshoots and overcurrent impacts during input voltage sags and recoveries, thereby significantly improving the transient disturbance rejection capability and operational robustness of the system.

  • Open Access

    The Optimization of Mechanical Phase-Shifting Transformer Tap Positions Based on an Open-Loop and Closed-Loop Hybrid Strategy

    by Jinjiao Lin, Jingyan Du, Shi Chen, Xinying Wang, Haodong Long, Chuyang Wang

    Phase-shifting transformers play a crucial role in power grid stability and efficiency. They adjust phase differences between loads, improve transmission efficiency, and balance loads during large-scale power transmission and grid integration. However, traditional mechanical phase-shifting transformers use fixed-tap designs with limited taps, preventing continuous and precise adjustments. This discrete adjustment method affects control accuracy and optimal tap position selection for proper power flow. This paper proposes a hybrid open-loop and closed-loop control strategy. This strategy maintains the phase-shifting transformer at its optimal tap position, enhancing system regulation precision and control effectiveness.


  • Open Access

    Single-Ended Protection Scheme for VSC-Based DC Microgrid Lines

    by Cheng Lv, Xiaodong Zheng, Nengling Tai, Shi Chen

    With the promotion of distributed energy and direct current (DC) loads, the DC microgrid is able to provide a higher power quality and improve the grid efficiency. Various technical issues in DC microgrids are still to be addressed, particularly a proper protection scheme for fault detection and isolation in DC microgrids utilizing voltage source converters (VSCs). In this paper, the pole-to-pole DC fault transient behavior of the VSC-based microgrids is firstly analyzed with four successive stages, and then the exact requirements for protections are presented. Furthermore, a novel single-ended protection scheme based on local transient signals is proposed, which needs no data transmission or synchronization between two ends, ensuring the speed. A four-terminal DC microgrid model was built in PSCAD/EMTDC. Numerous simulations have demonstrated the validity of the proposed scheme.


  • Open Access

    Adaptive distance protection for grounded fault of lines connected with doubly‐fed induction generators

    by Shi Chen, Nengling Tai, Chunju Fan, Jian Liu, Shubin Hong

    Crowbar circuit is a preferred solution to maintaining wind generators connected to the grid during a disturbance. However, the activation of crowbar protection will lead to an obvious difference between the positive sequence impedance of wind generators and the negative sequence one. This study analyses the influence of this unique fault characteristic of doubly‐fed induction generators (DFIGs) on the three zones of distance relays. When the transmission line emanates from a DFIG‐based wind farm, there exists a high probability that the conventional protective zones of distance relays fail to operate. Hence, an adaptive branch coefficient is proposed to calculate the zone 2 setting according to the fault type and equivalent sequence impedances of wind generators. The proposed adaptive setting principle realises a better coverage of zone 2 and enhances the reliability and sensitivity of the relays. Simulation results verify the improvement of the protective zone of distance relays.