Shi Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shi Chen has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Cheng Lv
Shanghai Jiao Tong University Shanghai People's Republic of China
1 shared publication Chunju Fan
Department of Electrical Engineering Shanghai Jiao Tong University Shanghai 200240 People's Republic of China
1 shared publication- Chuyang Wang
School of Electrical and Power Engineering, Hohai University, Nanjing 211100, China
1 shared publication - Haodong Long
School of Electrical and Power Engineering, Hohai University, Nanjing 211100, China
1 shared publication - Jian Liu
Department of Electrical Engineering Shanghai Jiao Tong University Shanghai 200240 People's Republic of China
1 shared publication - Jingyan Du
School of Electrical and Power Engineering, Hohai University, Nanjing 211100, China
1 shared publication
Latest Publications
- Open Access
Composite Model Predictive Control Strategy for Triple-Active-Bridge-Based MMDTC-PET with Enhanced Disturbance Resilience
To address the delayed dynamic response and susceptibility to overcurrent surges of the triple-active-bridge (TAB)-based modular multilevel DC-link T-type converter power electronic transformer (MMDTC-PET) under load step transients, this paper proposes a composite model predictive control (MPC) strategy to enhance the system’s disturbance rejection capability. The proposed strategy adopts a hierarchical control architecture comprising a proportional-integral (PI) outer power loop and an MPC inner loop. To tackle the heavy computational burden caused by multi-port coupling, dimensionality reduction is performed by equating the phase-shift ratios of the two primary-side ports of the TAB, which effectively mitigates the computational cost. Furthermore, a dynamic overcurrent hard-constraint penalty term and a control-effort smoothing term are incorporated into the multi-objective cost function. This not only achieves steady-state error-free tracking of the output voltage but also enhances physical operational safety under complex conditions at the algorithmic level. Comparative simulation results under various operating conditions demonstrate that, compared with the traditional PI-based phase-shift control, the proposed strategy exhibits a faster dynamic response under load step conditions. Moreover, it suppresses transient power overshoots and overcurrent impacts during input voltage sags and recoveries, thereby significantly improving the transient disturbance rejection capability and operational robustness of the system.
Open AccessComposite Model Predictive Control Strategy for Triple-Active-Bridge-Based MMDTC-PET with Enhanced Disturbance Resilience
To address the delayed dynamic response and susceptibility to overcurrent surges of the triple-active-bridge (TAB)-based modular multilevel DC-link T-type converter power electronic transformer (MMDTC-PET) under load step transients, this paper proposes a composite model predictive control (MPC) strategy to enhance the system’s disturbance rejection capability. The proposed strategy adopts a hierarchical control architecture comprising a proportional-integral (PI) outer power loop and an MPC inner loop. To tackle the heavy computational burden caused by multi-port coupling, dimensionality reduction is performed by equating the phase-shift ratios of the two primary-side ports of the TAB, which effectively mitigates the computational cost. Furthermore, a dynamic overcurrent hard-constraint penalty term and a control-effort smoothing term are incorporated into the multi-objective cost function. This not only achieves steady-state error-free tracking of the output voltage but also enhances physical operational safety under complex conditions at the algorithmic level. Comparative simulation results under various operating conditions demonstrate that, compared with the traditional PI-based phase-shift control, the proposed strategy exhibits a faster dynamic response under load step conditions. Moreover, it suppresses transient power overshoots and overcurrent impacts during input voltage sags and recoveries, thereby significantly improving the transient disturbance rejection capability and operational robustness of the system.
- Open Access
The Optimization of Mechanical Phase-Shifting Transformer Tap Positions Based on an Open-Loop and Closed-Loop Hybrid Strategy
Phase-shifting transformers play a crucial role in power grid stability and efficiency. They adjust phase differences between loads, improve transmission efficiency, and balance loads during large-scale power transmission and grid integration. However, traditional mechanical phase-shifting transformers use fixed-tap designs with limited taps, preventing continuous and precise adjustments. This discrete adjustment method affects control accuracy and optimal tap position selection for proper power flow. This paper proposes a hybrid open-loop and closed-loop control strategy. This strategy maintains the phase-shifting transformer at its optimal tap position, enhancing system regulation precision and control effectiveness.
Open AccessThe Optimization of Mechanical Phase-Shifting Transformer Tap Positions Based on an Open-Loop and Closed-Loop Hybrid Strategy
Phase-shifting transformers play a crucial role in power grid stability and efficiency. They adjust phase differences between loads, improve transmission efficiency, and balance loads during large-scale power transmission and grid integration. However, traditional mechanical phase-shifting transformers use fixed-tap designs with limited taps, preventing continuous and precise adjustments. This discrete adjustment method affects control accuracy and optimal tap position selection for proper power flow. This paper proposes a hybrid open-loop and closed-loop control strategy. This strategy maintains the phase-shifting transformer at its optimal tap position, enhancing system regulation precision and control effectiveness.
- Open Access
Single-Ended Protection Scheme for VSC-Based DC Microgrid Lines
With the promotion of distributed energy and direct current (DC) loads, the DC microgrid is able to provide a higher power quality and improve the grid efficiency. Various technical issues in DC microgrids are still to be addressed, particularly a proper protection scheme for fault detection and isolation in DC microgrids utilizing voltage source converters (VSCs). In this paper, the pole-to-pole DC fault transient behavior of the VSC-based microgrids is firstly analyzed with four successive stages, and then the exact requirements for protections are presented. Furthermore, a novel single-ended protection scheme based on local transient signals is proposed, which needs no data transmission or synchronization between two ends, ensuring the speed. A four-terminal DC microgrid model was built in PSCAD/EMTDC. Numerous simulations have demonstrated the validity of the proposed scheme.
Open AccessSingle-Ended Protection Scheme for VSC-Based DC Microgrid Lines
With the promotion of distributed energy and direct current (DC) loads, the DC microgrid is able to provide a higher power quality and improve the grid efficiency. Various technical issues in DC microgrids are still to be addressed, particularly a proper protection scheme for fault detection and isolation in DC microgrids utilizing voltage source converters (VSCs). In this paper, the pole-to-pole DC fault transient behavior of the VSC-based microgrids is firstly analyzed with four successive stages, and then the exact requirements for protections are presented. Furthermore, a novel single-ended protection scheme based on local transient signals is proposed, which needs no data transmission or synchronization between two ends, ensuring the speed. A four-terminal DC microgrid model was built in PSCAD/EMTDC. Numerous simulations have demonstrated the validity of the proposed scheme.
- Open Access
- 27 February 2017
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 11 (6) , 1513-1520
Adaptive distance protection for grounded fault of lines connected with doubly‐fed induction generators
Crowbar circuit is a preferred solution to maintaining wind generators connected to the grid during a disturbance. However, the activation of crowbar protection will lead to an obvious difference between the positive sequence impedance of wind generators and the negative sequence one. This study analyses the influence of this unique fault characteristic of doubly‐fed induction generators (DFIGs) on the three zones of distance relays. When the transmission line emanates from a DFIG‐based wind farm, there exists a high probability that the conventional protective zones of distance relays fail to operate. Hence, an adaptive branch coefficient is proposed to calculate the zone 2 setting according to the fault type and equivalent sequence impedances of wind generators. The proposed adaptive setting principle realises a better coverage of zone 2 and enhances the reliability and sensitivity of the relays. Simulation results verify the improvement of the protective zone of distance relays.
- 27 February 2017
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 11 (6) , 1513-1520
Open AccessAdaptive distance protection for grounded fault of lines connected with doubly‐fed induction generators
Crowbar circuit is a preferred solution to maintaining wind generators connected to the grid during a disturbance. However, the activation of crowbar protection will lead to an obvious difference between the positive sequence impedance of wind generators and the negative sequence one. This study analyses the influence of this unique fault characteristic of doubly‐fed induction generators (DFIGs) on the three zones of distance relays. When the transmission line emanates from a DFIG‐based wind farm, there exists a high probability that the conventional protective zones of distance relays fail to operate. Hence, an adaptive branch coefficient is proposed to calculate the zone 2 setting according to the fault type and equivalent sequence impedances of wind generators. The proposed adaptive setting principle realises a better coverage of zone 2 and enhances the reliability and sensitivity of the relays. Simulation results verify the improvement of the protective zone of distance relays.