Chuyang Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chuyang Wang has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
- Lan Xiao
Nanjing University of Aeronautics and Astronautics, Nanjing, China
8 shared publications - Li Zhang
School of Electrical and Power Engineering, Hohai University, Nanjing, China
8 shared publications Zitao Zhang
5 shared publications- Huijie Jiang
Nanjing, Jiangsu China
3 shared publications Jun Wang
Suzhou Power Supply Company, StateGrid Jiangsu Electric Power Company, Suzhou, 215004, China
3 shared publicationsKe Zhang
Suzhou Power Supply Company, StateGrid Jiangsu Electric Power Company, Suzhou, 215004, China
3 shared publications
Latest Publications
- Open Access
Dynamic Thermal Network Parameter Updating Strategy for IGBT Full-Bridge Modules in Digital Twin Applications
To meet the conflicting demands of real-time simulation and high fidelity for thermal modeling of IGBT modules in digital twin applications, this paper presents a dynamic thermal network parameter updating strategy. A hybrid thermal model is constructed by combining a high-fidelity finite-element-method reference model with a 3-D compact network. Initial thermal resistance and capacitance parameters are obtained via offline calibration and validated against the transient thermal impedance curve. A dynamic identification method based on recursive least squares with precomputed sensitivity matrices is then proposed. It dynamically updates each independent thermal branch using only real-time chip junction temperature measurements. The Vincotech full-bridge IGBT module is used for simulation validation. The proposed method achieves steady-state identification errors of 3.2% for the IGBT chip thermal resistance and 4.5% for the freewheeling diode chip thermal resistance, outperforming particle swarm optimization and dual Kalman filter in both convergence speed and steady-state accuracy. Thus, it satisfies the requirements of real-time tracking and dynamic evolution for thermal models in digital twin systems.
Open AccessDynamic Thermal Network Parameter Updating Strategy for IGBT Full-Bridge Modules in Digital Twin Applications
To meet the conflicting demands of real-time simulation and high fidelity for thermal modeling of IGBT modules in digital twin applications, this paper presents a dynamic thermal network parameter updating strategy. A hybrid thermal model is constructed by combining a high-fidelity finite-element-method reference model with a 3-D compact network. Initial thermal resistance and capacitance parameters are obtained via offline calibration and validated against the transient thermal impedance curve. A dynamic identification method based on recursive least squares with precomputed sensitivity matrices is then proposed. It dynamically updates each independent thermal branch using only real-time chip junction temperature measurements. The Vincotech full-bridge IGBT module is used for simulation validation. The proposed method achieves steady-state identification errors of 3.2% for the IGBT chip thermal resistance and 4.5% for the freewheeling diode chip thermal resistance, outperforming particle swarm optimization and dual Kalman filter in both convergence speed and steady-state accuracy. Thus, it satisfies the requirements of real-time tracking and dynamic evolution for thermal models in digital twin systems.
- Open Access
Principal–Slave Control Strategy for SLCC DC Interconnection System Considering Principal Station Capacity Margin
In flexible DC transmission and AC-DC interconnection systems, the Self-Adaption Station and Line Commutation Converter (SLCC) integrates static var compensation with conventional thyristor conversion functionality. This enables dynamic reactive power support at the valve side while improving commutation conditions, thereby enhancing the voltage support capability and operational robustness of DC systems. Under high renewable energy penetration, power fluctuations and sudden ramping challenges principal–slave controlled SLCC DC interconnection systems with a trade-off between principal-side DC voltage regulation and capacity margin constraints: Disturbance-induced active power demands may exceed available margins, causing DC voltage deviations and increasing protection trip risks. Leveraging the active/reactive decoupling characteristics of the SLCC topology, this paper proposes a principal–slave coordinated control strategy that accounts for principal station capacity margins. Methodologically, capacity margins are explicitly embedded into the principal station control mode. By reconstructing key variables in the DC voltage outer loop and introducing a closed-loop suppression mechanism with “over-capacity power” as feedback, the principal station maintains continuous voltage regulation while avoiding entry into over-capacity operation zones. On the slave side, a power support mechanism is designed to coordinate regulation among generation, storage, and load under power balance and equipment capacity constraints. This coordination process is formulated as a multi-objective optimization problem balancing disturbance economic losses with generation/storage utilization, solved using NSGA-II. Simulation results demonstrate that this strategy suppresses the risk of principle station overcapacity, enhances power sharing coordination during disturbance conditions, and improves DC voltage dynamic performance.
Open AccessPrincipal–Slave Control Strategy for SLCC DC Interconnection System Considering Principal Station Capacity Margin
In flexible DC transmission and AC-DC interconnection systems, the Self-Adaption Station and Line Commutation Converter (SLCC) integrates static var compensation with conventional thyristor conversion functionality. This enables dynamic reactive power support at the valve side while improving commutation conditions, thereby enhancing the voltage support capability and operational robustness of DC systems. Under high renewable energy penetration, power fluctuations and sudden ramping challenges principal–slave controlled SLCC DC interconnection systems with a trade-off between principal-side DC voltage regulation and capacity margin constraints: Disturbance-induced active power demands may exceed available margins, causing DC voltage deviations and increasing protection trip risks. Leveraging the active/reactive decoupling characteristics of the SLCC topology, this paper proposes a principal–slave coordinated control strategy that accounts for principal station capacity margins. Methodologically, capacity margins are explicitly embedded into the principal station control mode. By reconstructing key variables in the DC voltage outer loop and introducing a closed-loop suppression mechanism with “over-capacity power” as feedback, the principal station maintains continuous voltage regulation while avoiding entry into over-capacity operation zones. On the slave side, a power support mechanism is designed to coordinate regulation among generation, storage, and load under power balance and equipment capacity constraints. This coordination process is formulated as a multi-objective optimization problem balancing disturbance economic losses with generation/storage utilization, solved using NSGA-II. Simulation results demonstrate that this strategy suppresses the risk of principle station overcapacity, enhances power sharing coordination during disturbance conditions, and improves DC voltage dynamic performance.
- Open Access
An Abnormal Increase in Switching Frequency in Multi-Sources Line Commutated Converter and Suppression Method
Distinct from the traditional Modular Multilevel Converter (MMC) which focuses on fundamental frequency operation, the Static Var and Filter (SVF) within the Multi-Source Line-Commutated Converter (SLCC) system is tasked with the core function of high-frequency harmonic filtering. This paper reveals a unique engineering reliability issue stemming from this functional difference: to satisfy the Nyquist sampling theorem for precise tracking and elimination of high-frequency harmonics, the update frequency of the capacitor voltage balancing algorithm in the SLCC-SVF system is forced to increase significantly. Mathematical modeling and quantitative analysis demonstrate that this strong coupling between harmonic tracking demands and the voltage sorting strategy directly drives an abnormal surge in the average switching frequency (reaching over five times that of the fundamental condition), severely threatening device safety. To address this, an optimized adaptive hybrid modulation strategy is proposed. The system operates under Nearest Level Modulation (NLM) in normal conditions and automatically transitions to Carrier Phase-Shifted PWM (CPS-PWM)—leveraging its closed-loop balancing capability—when switching frequency or junction temperature exceeds safety thresholds. Furthermore, a non-integer frequency ratio optimization theory for low-modulation indices is constructed specifically for SVF conditions to prevent low-frequency oscillations. PLECS simulation results validate the theoretical analysis, showing that the proposed strategy effectively reduces the average switching frequency by approximately 20% under complex harmonic conditions, significantly enhancing thermal stability and operational reliability while guaranteeing filtering performance.
Open AccessAn Abnormal Increase in Switching Frequency in Multi-Sources Line Commutated Converter and Suppression Method
Distinct from the traditional Modular Multilevel Converter (MMC) which focuses on fundamental frequency operation, the Static Var and Filter (SVF) within the Multi-Source Line-Commutated Converter (SLCC) system is tasked with the core function of high-frequency harmonic filtering. This paper reveals a unique engineering reliability issue stemming from this functional difference: to satisfy the Nyquist sampling theorem for precise tracking and elimination of high-frequency harmonics, the update frequency of the capacitor voltage balancing algorithm in the SLCC-SVF system is forced to increase significantly. Mathematical modeling and quantitative analysis demonstrate that this strong coupling between harmonic tracking demands and the voltage sorting strategy directly drives an abnormal surge in the average switching frequency (reaching over five times that of the fundamental condition), severely threatening device safety. To address this, an optimized adaptive hybrid modulation strategy is proposed. The system operates under Nearest Level Modulation (NLM) in normal conditions and automatically transitions to Carrier Phase-Shifted PWM (CPS-PWM)—leveraging its closed-loop balancing capability—when switching frequency or junction temperature exceeds safety thresholds. Furthermore, a non-integer frequency ratio optimization theory for low-modulation indices is constructed specifically for SVF conditions to prevent low-frequency oscillations. PLECS simulation results validate the theoretical analysis, showing that the proposed strategy effectively reduces the average switching frequency by approximately 20% under complex harmonic conditions, significantly enhancing thermal stability and operational reliability while guaranteeing filtering performance.
- Open Access
- 1 January 2026
- Published by Tech Science Press in Energy Engineering
- Vol. 123 (6) , 1-10
A Digital Twin-Based Method for Degradation Parameter Identification of Electrolytic Capacitors in Full-Bridge Submodules of Unified Power Flow Controllers
Electrolytic capacitors in Modular Multilevel Converter-based Unified Power Flow Controllers (MMC-UPFC) are prone to parameter degradation, significantly affecting system reliability. Accurate identification of their degradation parameters—capacitance (C) and equivalent series resistance (ESR)—is essential for equipment health management. This study proposes a non-intrusive degradation parameter identification method for electrolytic capacitors in MMC-UPFC full-bridge submodules based on digital twin technology and an improved intelligent optimization algorithm. First, the degradation mechanism of electrolytic capacitors under long-term operational conditions is systematically analyzed. Second, a high-fidelity digital twin model integrating the main circuit, sampling circuit, and modulation circuit of the full-bridge submodule is established, enabling real-time synchronization between the physical and virtual systems. Third, based on the degradation characteristics of aluminum electrolytic capacitors, a condition monitoring objective function is formulated. An improved Particle Swarm Optimization (PSO) algorithm is proposed, which dynamically adjusts acceleration coefficients to iteratively optimize the monitored capacitance and ESR values, demonstrating superior convergence performance compared to conventional PSO. Verification results validate the effectiveness of the proposed method under various operating conditions. The computational efficiency of the method makes it suitable for quasi-online applications, and the monitoring cycle can be adjusted according to accuracy requirements. This study provides a practical solution for non-intrusive health monitoring of MMC-UPFC systems, contributing to improved equipment health management, extended system lifespan, and enhanced operational reliability in modern Flexible AC Transmission Systems (FACTS).
- 1 January 2026
- Published by Tech Science Press in Energy Engineering
- Vol. 123 (6) , 1-10
Open AccessA Digital Twin-Based Method for Degradation Parameter Identification of Electrolytic Capacitors in Full-Bridge Submodules of Unified Power Flow Controllers
Electrolytic capacitors in Modular Multilevel Converter-based Unified Power Flow Controllers (MMC-UPFC) are prone to parameter degradation, significantly affecting system reliability. Accurate identification of their degradation parameters—capacitance (C) and equivalent series resistance (ESR)—is essential for equipment health management. This study proposes a non-intrusive degradation parameter identification method for electrolytic capacitors in MMC-UPFC full-bridge submodules based on digital twin technology and an improved intelligent optimization algorithm. First, the degradation mechanism of electrolytic capacitors under long-term operational conditions is systematically analyzed. Second, a high-fidelity digital twin model integrating the main circuit, sampling circuit, and modulation circuit of the full-bridge submodule is established, enabling real-time synchronization between the physical and virtual systems. Third, based on the degradation characteristics of aluminum electrolytic capacitors, a condition monitoring objective function is formulated. An improved Particle Swarm Optimization (PSO) algorithm is proposed, which dynamically adjusts acceleration coefficients to iteratively optimize the monitored capacitance and ESR values, demonstrating superior convergence performance compared to conventional PSO. Verification results validate the effectiveness of the proposed method under various operating conditions. The computational efficiency of the method makes it suitable for quasi-online applications, and the monitoring cycle can be adjusted according to accuracy requirements. This study provides a practical solution for non-intrusive health monitoring of MMC-UPFC systems, contributing to improved equipment health management, extended system lifespan, and enhanced operational reliability in modern Flexible AC Transmission Systems (FACTS).
- Open Access
- 1 January 2026
- Published by Tech Science Press in Energy Engineering
- Vol. 123 (6) , 1-10
A Coordinated Control Strategy for SLCC Considering SVF Withstand Capability under Fault Conditions
The self-adaption STATCOM and line commutation converter (SLCC) system based on the static var generator and filter (SVF) utilizes the compensation capability of the SVF to reduce the commutation process’s dependence on the AC grid, thereby enhancing the SLCC’s ability to resist commutation failure. However, existing SLCC control strategies have not fully considered the boundary conditions for the safe and stable operation of the SVF (i.e., the SVF withstand capability), which limits or even deteriorates the ability of the SVF to provide commutation support for the SLCC under AC grid voltage fault conditions. To address this issue, this paper first analyzes the current and voltage limit boundaries of the SVF in the SLCC system from the perspective of SVF device stress, revealing the mechanism of SVF withstand capability exceedance under fault conditions. Based on this analysis, a voltage feedforward control strategy that accounts for the SVF withstand capability is proposed. This strategy accelerates the dynamic response of the SVF under fault conditions and enhances the SLCC’s ability to resist commutation failure, while strictly avoiding the risks of SVF current and voltage exceedance, thereby ensuring the SVF operates within its withstand capability boundaries and improving support security under fault conditions. Furthermore, based on the SVF withstand capability boundaries, the commutation margin required to maintain safe commutation for the SLCC is calculated, and the SLCC inversion angle is dynamically adjusted accordingly. This achieves coordinated control between the SLCC and the SVF, preventing SVF blocking due to exceeding its withstand capability and ensuring safe commutation of the SLCC. Simulation results verify that the proposed strategy can simultaneously achieve non-blocking operation of the SVF and safe commutation of the SLCC.
- 1 January 2026
- Published by Tech Science Press in Energy Engineering
- Vol. 123 (6) , 1-10
Open AccessA Coordinated Control Strategy for SLCC Considering SVF Withstand Capability under Fault Conditions
The self-adaption STATCOM and line commutation converter (SLCC) system based on the static var generator and filter (SVF) utilizes the compensation capability of the SVF to reduce the commutation process’s dependence on the AC grid, thereby enhancing the SLCC’s ability to resist commutation failure. However, existing SLCC control strategies have not fully considered the boundary conditions for the safe and stable operation of the SVF (i.e., the SVF withstand capability), which limits or even deteriorates the ability of the SVF to provide commutation support for the SLCC under AC grid voltage fault conditions. To address this issue, this paper first analyzes the current and voltage limit boundaries of the SVF in the SLCC system from the perspective of SVF device stress, revealing the mechanism of SVF withstand capability exceedance under fault conditions. Based on this analysis, a voltage feedforward control strategy that accounts for the SVF withstand capability is proposed. This strategy accelerates the dynamic response of the SVF under fault conditions and enhances the SLCC’s ability to resist commutation failure, while strictly avoiding the risks of SVF current and voltage exceedance, thereby ensuring the SVF operates within its withstand capability boundaries and improving support security under fault conditions. Furthermore, based on the SVF withstand capability boundaries, the commutation margin required to maintain safe commutation for the SLCC is calculated, and the SLCC inversion angle is dynamically adjusted accordingly. This achieves coordinated control between the SLCC and the SVF, preventing SVF blocking due to exceeding its withstand capability and ensuring safe commutation of the SLCC. Simulation results verify that the proposed strategy can simultaneously achieve non-blocking operation of the SVF and safe commutation of the SLCC.
- Open Access
The Optimization of Mechanical Phase-Shifting Transformer Tap Positions Based on an Open-Loop and Closed-Loop Hybrid Strategy
Phase-shifting transformers play a crucial role in power grid stability and efficiency. They adjust phase differences between loads, improve transmission efficiency, and balance loads during large-scale power transmission and grid integration. However, traditional mechanical phase-shifting transformers use fixed-tap designs with limited taps, preventing continuous and precise adjustments. This discrete adjustment method affects control accuracy and optimal tap position selection for proper power flow. This paper proposes a hybrid open-loop and closed-loop control strategy. This strategy maintains the phase-shifting transformer at its optimal tap position, enhancing system regulation precision and control effectiveness.
Open AccessThe Optimization of Mechanical Phase-Shifting Transformer Tap Positions Based on an Open-Loop and Closed-Loop Hybrid Strategy
Phase-shifting transformers play a crucial role in power grid stability and efficiency. They adjust phase differences between loads, improve transmission efficiency, and balance loads during large-scale power transmission and grid integration. However, traditional mechanical phase-shifting transformers use fixed-tap designs with limited taps, preventing continuous and precise adjustments. This discrete adjustment method affects control accuracy and optimal tap position selection for proper power flow. This paper proposes a hybrid open-loop and closed-loop control strategy. This strategy maintains the phase-shifting transformer at its optimal tap position, enhancing system regulation precision and control effectiveness.
- Open Access
- 25 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 134683-134698
Performance Boundaries and Related Improvement Method of Sub-Oscillation- Suppression Capabilities in Continuously Adjustable Phase-Shifting Transformer
The increasing penetration of power electronic devices has elevated the possibility of sub-synchronous oscillation (SSO) in the power grid. At the same time, the continuously adjustable phase-shifting transformer (CAPST) exhibits a certain capability for SSO suppression while regulating power flow. To clarify the SSO suppression mechanism and enhance its suppression capability, this study first analyzes the oscillation suppression mechanism of the CAPST, quantifies the boundaries of its oscillation suppression performance, and reveals inherent limitations of CAPST, including inadequate SSO suppression capability and the inability to simultaneously achieve effective power flow regulation and SSO suppression. To further extend the SSO suppression performance boundary, a capacitive series-compensated phase-shifting transformer (CSCPST) is introduced, accompanied by a design method for the series compensation capacitor. Additionally, to address the associated issue of power-flow reversal, a hybrid open-closed-loop power flow regulation strategy is proposed. Finally, simulation studies are conducted on both the CAPST and the CSCPST. The results verified the limitations of CAPST in SSO suppression capability and confirmed the superior performance of the CSCPST in enhancing SSO suppression and simultaneously achieving effective power flow regulation and SSO suppression.
- 25 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 134683-134698
Open AccessPerformance Boundaries and Related Improvement Method of Sub-Oscillation- Suppression Capabilities in Continuously Adjustable Phase-Shifting Transformer
The increasing penetration of power electronic devices has elevated the possibility of sub-synchronous oscillation (SSO) in the power grid. At the same time, the continuously adjustable phase-shifting transformer (CAPST) exhibits a certain capability for SSO suppression while regulating power flow. To clarify the SSO suppression mechanism and enhance its suppression capability, this study first analyzes the oscillation suppression mechanism of the CAPST, quantifies the boundaries of its oscillation suppression performance, and reveals inherent limitations of CAPST, including inadequate SSO suppression capability and the inability to simultaneously achieve effective power flow regulation and SSO suppression. To further extend the SSO suppression performance boundary, a capacitive series-compensated phase-shifting transformer (CSCPST) is introduced, accompanied by a design method for the series compensation capacitor. Additionally, to address the associated issue of power-flow reversal, a hybrid open-closed-loop power flow regulation strategy is proposed. Finally, simulation studies are conducted on both the CAPST and the CSCPST. The results verified the limitations of CAPST in SSO suppression capability and confirmed the superior performance of the CSCPST in enhancing SSO suppression and simultaneously achieving effective power flow regulation and SSO suppression.
- Open Access
Research on Missing Data Estimation Method for UPFC Submodules Based on Bayesian Multiple Imputation and Support Vector Machines
With the increasing complexity of power systems, the monitoring data of UPFC submodules suffers from high missing rates due to sensor failures and environmental interference, significantly limiting equipment condition assessment and fault warning capabilities. To overcome the computational complexity, poor real-time performance, and limited generalization of existing methods like GRU-GAN and SOM-LSTM, this study proposes a hybrid framework combining Bayesian multiple imputation with a Support Vector Machine (SVM) for data repair. The framework first employs an adaptive Kalman filter to denoise raw data and remove outliers, followed by Bayesian multiple imputation that constructs posterior distributions using normal linear correlations between historical and operational data, generating optimized imputed values through arithmetic averaging. A kernel-based SVM with RBF and soft margin optimization is then applied for nonlinear calibration to enhance robustness and consistency in high-dimensional scenarios. Experimental validation focusing on capacitor voltage, current, and temperature parameters of UPFC submodules under a 50% missing data scenario demonstrates that the proposed method achieves an 18.7% average error reduction and approximately 30% computational efficiency improvement compared to single imputation and traditional multiple imputation approaches, significantly outperforming neural network models. This study confirms the effectiveness of integrating Bayesian statistics with machine learning for power data restoration, providing a high-precision and low-complexity solution for equipment condition monitoring in complex operational environments. Future research will explore dynamic weight optimization and extend the framework to multi-source heterogeneous data applications.
Open AccessResearch on Missing Data Estimation Method for UPFC Submodules Based on Bayesian Multiple Imputation and Support Vector Machines
With the increasing complexity of power systems, the monitoring data of UPFC submodules suffers from high missing rates due to sensor failures and environmental interference, significantly limiting equipment condition assessment and fault warning capabilities. To overcome the computational complexity, poor real-time performance, and limited generalization of existing methods like GRU-GAN and SOM-LSTM, this study proposes a hybrid framework combining Bayesian multiple imputation with a Support Vector Machine (SVM) for data repair. The framework first employs an adaptive Kalman filter to denoise raw data and remove outliers, followed by Bayesian multiple imputation that constructs posterior distributions using normal linear correlations between historical and operational data, generating optimized imputed values through arithmetic averaging. A kernel-based SVM with RBF and soft margin optimization is then applied for nonlinear calibration to enhance robustness and consistency in high-dimensional scenarios. Experimental validation focusing on capacitor voltage, current, and temperature parameters of UPFC submodules under a 50% missing data scenario demonstrates that the proposed method achieves an 18.7% average error reduction and approximately 30% computational efficiency improvement compared to single imputation and traditional multiple imputation approaches, significantly outperforming neural network models. This study confirms the effectiveness of integrating Bayesian statistics with machine learning for power data restoration, providing a high-precision and low-complexity solution for equipment condition monitoring in complex operational environments. Future research will explore dynamic weight optimization and extend the framework to multi-source heterogeneous data applications.
- Open Access
- 20 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 177692-177710
Analysis and Suppression of Harmonic Deteriorations Related to a Few-Submodule and Low-Switching-Frequency MMC-Based UPFC
System efficiency, power quality, and economic benefits have always been essential for the Unified Power Flow Controller (UPFC based on a Modular Multilevel Converter (MMC). This paper proposes a low-switching-frequency MMC-UPFC operation scheme based on the carrier phase shift pulse width modulation (CPS-PWM), which can significantly reduce switching loss and improve system efficiency. However, in medium-voltage MMC applications, the number of sub-modules in the UPFC is usually small (less than 30) exacerbating the harmonic distortions in the MMC-UPFC and reducing the switching frequency further deteriorates harmonics and increases capacitor voltage ripple. Therefore, to address the increased capacitor voltage ripple caused by low switching frequency, this paper proposes a reasonable carrier ratio (FR) design method. Analyzing and suppressing the capacitor voltage ripple at low switching frequencies can maintain capacitor voltage stability while significantly reducing the switching frequency. To address the issue of increased harmonics due to low switching frequency and few sub-modules, this paper combines the FR design method with an active LLCL filter method. An improved genetic algorithm is used to establish an objective function related to switching frequency harmonics and total inductance value, which can suppress a large number of high-order harmonics remaining from the CPS-PWM scheme, reduce the total inductance value, and compare this method with the single L filtering scheme widely used in UPFC engineering planning. Simulation on PLECS software verifies the effectiveness of the proposed method.
- 20 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 177692-177710
Open AccessAnalysis and Suppression of Harmonic Deteriorations Related to a Few-Submodule and Low-Switching-Frequency MMC-Based UPFC
System efficiency, power quality, and economic benefits have always been essential for the Unified Power Flow Controller (UPFC based on a Modular Multilevel Converter (MMC). This paper proposes a low-switching-frequency MMC-UPFC operation scheme based on the carrier phase shift pulse width modulation (CPS-PWM), which can significantly reduce switching loss and improve system efficiency. However, in medium-voltage MMC applications, the number of sub-modules in the UPFC is usually small (less than 30) exacerbating the harmonic distortions in the MMC-UPFC and reducing the switching frequency further deteriorates harmonics and increases capacitor voltage ripple. Therefore, to address the increased capacitor voltage ripple caused by low switching frequency, this paper proposes a reasonable carrier ratio (FR) design method. Analyzing and suppressing the capacitor voltage ripple at low switching frequencies can maintain capacitor voltage stability while significantly reducing the switching frequency. To address the issue of increased harmonics due to low switching frequency and few sub-modules, this paper combines the FR design method with an active LLCL filter method. An improved genetic algorithm is used to establish an objective function related to switching frequency harmonics and total inductance value, which can suppress a large number of high-order harmonics remaining from the CPS-PWM scheme, reduce the total inductance value, and compare this method with the single L filtering scheme widely used in UPFC engineering planning. Simulation on PLECS software verifies the effectiveness of the proposed method.