TDTammy L. Haut Donahue

Tammy L. Haut Donahue

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tammy L. Haut Donahue has a total of 32 co-authors. Here are the top co-authors by number of shared publications:

  • Loic Dejardin

    Department of Small Animal Clinical Sciences, Michigan State University , East Lansing, MI 48824

    3 shared publications
  • Roger C. Haut

    Orthopaedic Biomechanics Laboratories, College of Osteopathic Medicine, Michigan State University , East Lansing, MI 48824 ; , East Lansing, MI 48824

    3 shared publications
  • Daniel James Kelly

    Trinity Centre for Biomedical Engineering, Trinity Biomedical Sciences Institute, Trinity College Dublin, Dublin, Ireland

    2 shared publications
  • Feng Wei

    Orthopaedic Biomechanics Laboratories, College of Osteopathic Medicine, Michigan State University, East Lansing, USA

    2 shared publications
  • Gerardo E. Narez

    Department of Biomedical Engineering, University of Massachusetts Amherst , Amherst, MA 01003

    2 shared publications
  • Hannah M. Pauly

    School of Biomedical Engineering, Colorado State University, Fort Collins, Colorado, USA

    2 shared publications

Latest Publications

  • Evaluating the Efficacy of Combined P188 Treatment and Surgical Intervention in Preventing Post-Traumatic Osteoarthritis Following a Traumatic Knee Injury

    by Gerardo E. Narez, Gabriel Brown, Ashley Herrick, Ryan J. Ek, Loic Dejardin, Feng Wei, Roger C. Haut, Tammy L. Haut Donahue

    Previous studies have shown that reconstructive surgery alone following injury to the anterior cruciate ligament (ACL) does not prevent the development of post-traumatic osteoarthritis (PTOA). Poloxamer 188 (P188) has been shown to prevent cell death following trauma in both articular cartilage and meniscal tissue. This study aims to test the efficacy of single or multiple administrations of P188 in conjunction with reconstructive surgery to help prevent or delay the onset of the disease. Thirty skeletally mature rabbits underwent closed-joint trauma that resulted in ACL rupture and meniscal damage and were randomly assigned to one of four treatment groups with varying doses of P188. ACL reconstruction was then performed using an autograft from the semitendinosus tendon. Animals were euthanized 1-month following trauma, meniscal tissue was assessed for changes in morphology, mechanical properties, and proteoglycan content. Femurs and tibias were scanned using microcomputed tomography to determine changes in bone quality, architecture, and osteophyte formation. The medial meniscus experienced more damage and a decrease in the instantaneous modulus regardless of treatment group, while P188 treatment tended to limit degenerative changes in the lateral meniscus. Both lateral and medial menisci had documented decreases in the equilibrium modulus and inconsistent changes in proteoglycan content. Minimal changes were documented in the tibias and femurs, with the only significant change being the formation of osteophytes in both bones regardless of treatment group. The data suggest that P188 was able to limit some degenerative changes in the meniscus associated with PTOA and may warrant future studies.


  • Assessment of changes in the meniscus and subchondral bone in a novel closed-joint impact and surgical reconstruction lapine model

    by Gerardo E. Narez, Gabriel Brown, Ashley Herrick, Ryan J. Ek, Loic Dejardin, Feng Wei, Roger C. Haut, Tammy L. Haut Donahue


  • Osteoarthritic meniscal entheses exhibit altered collagen fiber orientation

    by Tammy L. Haut Donahue, Hannah M. Pauly

    The knee menisci are vital for maintaining the stability of the joint, allowing for force distribution, and protecting the underlying articular cartilage during loading. Each meniscus is attached to the underlying bone via two ligamentous entheses composed of collagen fibers that are continuous throughout all four zones of the attachment: ligament, uncalcified fibrocartilage, calcified fibrocartilage, and subchondral bone. The collagen fibers of the meniscal entheses are thought to be important for proper functionality of the entheses, particularly in preventing meniscal extrusion which is a common hallmark of osteoarthritis. The goal of this work was to assess changes in collagen fiber orientation present in osteoarthritic knee joints. Entheses were harvested from patients undergoing total knee arthroplasties and prepared histological sections were stained with picrosirius red to identify collagen fiber angle and fiber deviation. In the calcified fibrocartilage the collagen fibers of the lateral anterior enthesis inserted at significantly (p<0.1) shallower angles, and the fiber deviation was significantly (p<0.1) less compared to the lateral posterior enthesis. These differences in the calcified fibrocartilage may occur as an adaptation to loading regimes of the osteoarthritic joint. When compared to the collagen fiber orientation of healthy entheses, collagen fibers in osteoarthritic tissue inserted at shallower insertion angles and demonstrated higher levels of deviation. Changes to meniscal enthesis collagen fiber orientation with end stage osteoarthritis could offer an explanation for the change in functionality of diseased tissue and may contribute to meniscal extrusion and ultimately the degeneration of articular cartilage.


  • Open Access

    Improving the Intercellular Uptake and Osteogenic Potency of Calcium Phosphate via Nanocomplexation with the RALA Peptide

    by Michelle O’doherty, Eoghan J. Mulholland, Philip Chambers, Sreekanth Pentlavalli, Monika Ziminska, Marine J. Chalanqui, Hannah M. Pauly, Binulal N. Sathy, Tammy H. Donahue, Daniel J. Kelly, et al.

    Calcium phosphate-base materials (e.g., alpha tri-calcium phosphate (α–TCP)) have been shown to promote osteogenic differentiation of stem/progenitor cells, enhance osteoblast osteogenic activity and mediate in vivo bone tissue formation. However, variable particle size and hydrophilicity of the calcium phosphate result in an extremely low bioavailability. Therefore, an effective delivery system is required that can encapsulate the calcium phosphate, improve cellular entry and, consequently, elicit a potent osteogenic response in osteoblasts. In this study, collagenous matrix deposition and extracellular matrix mineralization of osteoblast lineage cells were assessed to investigate osteogenesis following intracellular delivery of α-TCP nanoparticles. The nanoparticles were formed via condensation with a novel, cationic 30 mer amphipathic peptide (RALA). Nanoparticles prepared at a mass ratio of 5:1 demonstrated an average particle size of 43 nm with a zeta potential of +26 mV. The average particle size and zeta potential remained stable for up to 28 days at room temperature and across a range of temperatures (4–37 °C). Cell viability decreased 24 h post-transfection following RALA/α-TCP nanoparticle treatment; however, recovery ensued by Day 7. Immunocytochemistry staining for Type I collagen up to Day 21 post-transfection with RALA/α-TCP nanoparticles (NPs) in MG-63 cells exhibited a significant enhancement in collagen expression and deposition compared to an untreated control. Furthermore, in porcine mesenchymal stem cells (pMSCs), there was enhanced mineralization compared to α–TCP alone. Taken together these data demonstrate that internalization of RALA/α-TCP NPs elicits a potent osteogenic response in both MG-63 and pMSCs.


  • Loosening of Transtibial Pullout Meniscal Root Repairs due to Simulated Rehabilitation Is Unrecoverable: A Biomechanical Study

    by Brett D. Steineman, Robert F. LaPrade, Tammy L. Haut Donahue

    To determine whether meniscal root repairs recover from displacement due to rehabilitative loading. Transtibial pullout repairs of the posteromedial meniscal root were performed in 16 cadaveric ovine knees. Single- and double-tunnel repairs using the 2-simple suture technique were cyclically loaded in tension to 10,000 cycles, allowed to rest, and loaded in tension again. Paired differences in displacement with rest were recorded to evaluate recoverability. Displacement of repairs at cycles of interest was recorded, and the response of repairs to 10,000 cycles was assessed. All outcomes were not significantly different between the single- and double-tunnel techniques; therefore, the results were pooled. The difference in displacement between the first cycle and the first cycle after rest was 1.59 ± 0.69 mm. Repair displacement did not reach an equilibrium within 10,000 cycles and instead resulted in a steady increase in displacement of 0.05 ± 0.02 mm per additional 1,000 cycles. Sutures macroscopically began to cut out of the meniscus in both single- and double-tunnel repairs. This study showed that significant, unrecoverable loosening from rehabilitative loading occurred in single- and double-tunnel meniscal root repairs. Root repairs also gradually displaced with continued loading instead of reaching an equilibrium displacement after 10,000 cycles. This progressive, unrecoverable loosening needs to be studied further to better understand the resultant impact on knee mechanics. In addition, the quality and quantity of meniscal root repair healing at the time of rehabilitation should be studied to determine how susceptible patients are to repair loosening. Rehabilitative loading caused unrecoverable and progressive loosening of root repairs, showing the importance of healing before loading. Investigations on the effects of loosening on mechanics and the quality of repair healing at weight bearing are necessary to better understand the clinical implications.


  • Mechanical properties of a hierarchical electrospun scaffold for ovine anterior cruciate ligament replacement

    by Hannah Pauly, Daniel Kelly, Ketul Popat, Jeremiah Easley, Ross Palmer, Tammy L. Haut Donahue

    The anterior cruciate ligament (ACL) acts to stabilize the knee and prevent excessive motion of the tibia relative to the femur. Tears of the ACL are common and can result in pain and damage to surrounding tissues. Thus a torn ACL is often surgically replaced with an autograft or allograft material. Drawbacks to clinically available ACL grafts motivate the development of a tissue engineered ACL replacement. Our group has previously developed a polycaprolactone electrospun scaffold that mimics the hierarchical structure of the ACL. The goal of this study was to investigate the mechanical properties of the electrospun scaffold as an ACL replacement. Scaffold mechanical properties were assessed prior to implantation via stress relaxation and pull to failure testing. Following in vitro characterization, electrospun scaffolds and soft tissue grafts were implanted into ovine cadaver stifle joints as ACL replacements. Stifle joints with ACL replacements were tested via a simulated anterior drawer test as well as in situ stress relaxation and pull to failure tests and compared to stifle joints with the native ACL intact. Prior to implantation the scaffold matched the native ovine ACL well in the range of functional strains as evidenced by stress relaxation measures and the toe region stiffness. After implantation the scaffold was more similar to the native ACL than the soft tissue graft, particularly when it came to reducing joint laxity and matching stress relaxation measures. These results demonstrate that the electrospun scaffold has the potential to be a suitable material for ACL replacement.


  • A Hydrogel Meniscal Replacement: Knee Joint Pressure and Distribution in an Ovine Model Compared to Native Tissue

    by Kristine M. Fischenich, Hannah M. Pauly, Jackson T. Lewis, Travis S. Bailey, Tammy L. Haut Donahue

    Pressure distribution of the native ovine knee meniscus was compared to a medial meniscectomy and three treatment conditions including a suture reattachment of the native tissue, an allograft, and a novel thermoplastic elastomer hydrogel (TPE) construct. The objective of this study was to assess the efficacy of a novel TPE hydrogel construct at restoring joint pressure and distribution. Limbs were loaded in uniaxial compression at 45°, 60°, and 75° flexion and from 0 to 181 kg. The medial meniscectomy decreased contact area by approximately 50% and doubled the mean and maximum pressure reading for the medial hemijoint. No treatment condition tested within this study was able to fully restore medial joint contact area and pressures to the native condition. A decrease in lateral contact area and increase in pressures with the meniscectomy was also seen; and to some degree, all reattachment and replacement conditions including the novel TPE hydrogel replacement helped to restore lateral pressures. Although the TPE construct did not perform as well as hoped in the medial compartment, it performed as well as, if not better, than the other reattachment and replacement options in the lateral. Further work is necessary to determine the best anchoring and attachment methods.