A Hydrogel Meniscal Replacement: Knee Joint Pressure and Distribution in an Ovine Model Compared to Native Tissue
- 19 June 2018
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 46 (11) , 1785-1796
Abstract
Pressure distribution of the native ovine knee meniscus was compared to a medial meniscectomy and three treatment conditions including a suture reattachment of the native tissue, an allograft, and a novel thermoplastic elastomer hydrogel (TPE) construct. The objective of this study was to assess the efficacy of a novel TPE hydrogel construct at restoring joint pressure and distribution. Limbs were loaded in uniaxial compression at 45°, 60°, and 75° flexion and from 0 to 181 kg. The medial meniscectomy decreased contact area by approximately 50% and doubled the mean and maximum pressure reading for the medial hemijoint. No treatment condition tested within this study was able to fully restore medial joint contact area and pressures to the native condition. A decrease in lateral contact area and increase in pressures with the meniscectomy was also seen; and to some degree, all reattachment and replacement conditions including the novel TPE hydrogel replacement helped to restore lateral pressures. Although the TPE construct did not perform as well as hoped in the medial compartment, it performed as well as, if not better, than the other reattachment and replacement options in the lateral. Further work is necessary to determine the best anchoring and attachment methods.Keywords
Funding Information
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (R21 AR069826)
This publication has 41 references indexed in Scilit:
- Design of a Free-Floating Polycarbonate-Urethane Meniscal Implant Using Finite Element Modeling and Experimental ValidationJournal of Biomechanical Engineering, 2010
- Implantation of a synthetic meniscal scaffold improves joint contact mechanics in a partial meniscectomy cadaver modelJournal of Biomedical Materials Research Part A, 2009
- Meniscus structure in human, sheep, and rabbit for animal models of meniscus repairJournal of Orthopaedic Research, 2009
- Effect of Calibration Method on Tekscan Sensor AccuracyJournal of Biomechanical Engineering, 2008
- A new technique to measure the dynamic contact pressures on the Tibial PlateauJournal of Biomechanics, 2008
- Experimental Measurement of Tibiofemoral Contact Area in a Meniscectomized Ovine Model Using a Resistive Pressure Measuring SensorAnnals of Biomedical Engineering, 2006
- Tibio-femoral joint contact forces in sheepJournal of Biomechanics, 2006
- Meniscal allograft transplantation—part I: Background, results, graft selection and preservation, and surgical considerationsArthroscopy, 2004
- Interspecies variation of compressive biomechanical properties of the meniscusJournal of Biomedical Materials Research, 1995
- In-Vitro of Measurement of Static Pressure Distribution in Synovial Joints—Part I: Tibial Surface of the KneeJournal of Biomechanical Engineering, 1983