JTJared J. Thomas

Jared J. Thomas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jared J. Thomas has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A numerical framework for optimal trade-offs between land use and LCOE using efficient, blockage-aware multi-fidelity methods

    by Cory Frontin, Jeff Allen, Christopher J. Bay, Jared Thomas, Ethan Young, Pietro Bortolotti

    This paper introduces a novel approach to efficiently estimate the annual energy production (AEP) of a wind farm. The numerical predictions are generated thanks to a multi-fidelity model that combines a classical low-fidelity wake engineering solver with a mid-fidelity computational fluid dynamic solver. The novel setup is not only faster than conventional approaches but is also capable of estimating the AEP of tightly spaced wind farms. Using this approach, we explore the trade-off between land use and levelized cost of energy (LCOE) for a wind farm made of 25 turbines. The results of this study, which ignore impact the layout sensitivity of fatigue loads and their incumbent effect on costs, quantify the penalty on LCOE performance that can be paid to restrict the land use of a wind farm. The results also exhibit the novel capabilities of our approach for multi-fidelity wind farm design to avoid false optima according to incomplete representations of the relevant physical phenomena.

  • Open Access

    Efficient wind farm layout optimization with the FLOWERS AEP model and analytic gradients

    by Michael J. LoCascio, Christopher J. Bay, Luis A. Martínez-Tossas, Jared J. Thomas, Catherine Gorlé

    Wind farm layout optimization (WFLO) studies often aim to maximize the annual energy production (AEP) of a wind farm by choosing an arrangement of turbines that minimizes wake interactions. One way to reduce the cost of WFLO studies is by using more computationally efficient AEP models. The cost of standard AEP modeling approaches, based on the numerical integration of low-fidelity engineering wake models, scales poorly with the number of simulated discrete wind conditions. A second way to reduce cost when using a gradient-based algorithm is to supply exact gradient information instead of finite-difference estimates. However, analytical functions for the derivatives of AEP with respect to turbine positions are not always available in the conventional modeling approach. FLOWERS is a computationally inexpensive, analytical model for wind farm AEP that is specifically developed for WFLO applications. In this paper, we analyze the performance of the FLOWERS AEP model with analytic gradients in a layout optimization study compared with a reference optimization framework across three wind farm case studies. We find that the FLOWERS-based approach reduces computation time by a factor of 50–4000 and improves optimal AEP by about 0.3% with less than half of the variability in AEP across instances with randomized initial conditions. We also find the optimal layouts to be insensitive to model parameter tuning, making FLOWERS-based layout optimization a streamlined, user-friendly approach.


  • Energy Clusters Offshore: A Technology Feasibility Review

    by Chloe Constant, Caitlyn Clark, Masha Koleva, Kaitlin Brunik, Jared Thomas, Matthew Kotarbinski, James Niffenegger, Jochem Weber


  • Top Cited Papers
    Open Access

    A comparison of eight optimization methods applied to a wind farm layout optimization problem

    by Jared J. Thomas, Nicholas F. Baker, Paul Malisani, Erik Quaeghebeur, Sebastian Sanchez Perez-Moreno, John Jasa, Christopher Bay, Federico Tilli, David Bieniek, Nick Robinson, et al.

    Selecting a wind farm layout optimization method is difficult. Comparisons between optimization methods in different papers can be uncertain due to the difficulty of exactly reproducing the objective function. Comparisons by just a few authors in one paper can be uncertain if the authors do not have experience using each algorithm. In this work we provide an algorithm comparison for a wind farm layout optimization case study between eight optimization methods applied, or directed, by researchers who developed those algorithms or who had other experience using them. We provided the objective function to each researcher to avoid ambiguity about relative performance due to a difference in objective function. While these comparisons are not perfect, we try to treat each algorithm more fairly by having researchers with experience using each algorithm apply each algorithm and by having a common objective function provided for analysis. The case study is from the International Energy Association (IEA) Wind Task 37, based on the Borssele III and IV wind farms with 81 turbines. Of particular interest in this case study is the presence of disconnected boundary regions and concave boundary features. The optimization methods studied represent a wide range of approaches, including gradient-free, gradient-based, and hybrid methods; discrete and continuous problem formulations; single-run and multi-start approaches; and mathematical and heuristic algorithms. We provide descriptions and references (where applicable) for each optimization method, as well as lists of pros and cons, to help readers determine an appropriate method for their use case. All the optimization methods perform similarly, with optimized wake loss values between 15.48 % and 15.70 % as compared to 17.28 % for the unoptimized provided layout. Each of the layouts found were different, but all layouts exhibited similar characteristics. Strong similarities across all the layouts include tightly packing wind turbines along the outer borders, loosely spacing turbines in the internal regions, and allocating similar numbers of turbines to each discrete boundary region. The best layout by annual energy production (AEP) was found using a new sequential allocation method, discrete exploration-based optimization (DEBO). Based on the results in this study, it appears that using an optimization algorithm can significantly improve wind farm performance, but there are many optimization methods that can perform well on the wind farm layout optimization problem, given that they are applied correctly.


  • Open Access

    A Comparison of Eight Optimization Methods Applied to a Wind Farm Layout Optimization Problem

    by Jared J. Thomas, Nicholas F. Baker, Paul Malisani, Erik Quaeghebeur, Sebastian Sanchez Perez-Moreno, John Jasa, Christopher Bay, Federico Tilli, David Bieniek, Nick Robinson, et al.

    Selecting a wind farm layout optimization method is difficult. Comparisons between optimization methods in different papers can be uncertain due to the difficulty of exactly reproducing the objective function. Comparisons by just a few authors in one paper can be uncertain if the authors do not have experience using each algorithm. In this work we provide an algorithm comparison for a wind farm layout optimization case study between eight optimization methods applied, or directed, by researchers who developed those algorithms or who had other experience using them. We provided the objective function to each researcher to avoid ambiguity about relative performance due to a difference in objective function. While these comparisons are not perfect, we try to treat each algorithm more fairly by having researchers with experience using each algorithm apply each algorithm and by having a common objective function provided for analysis. The case study is from the IEA Wind Task 37, based on the Borssele III and IV wind farms with 81 turbines. Of particular interest in this case study is the presence of disconnected boundary regions and concave boundary features. The optimization methods studied represent a wide range of approaches, including gradient-free, gradient-based, and hybrid methods; discrete and continuous problem formulations; single-run and multi-start approaches; and mathematical and heuristic algorithms. We provide descriptions and references (where applicable) for each optimization method as well as lists of pros and cons to help readers determine an appropriate method for their use case. All the optimization methods perform similarly, with optimized wake loss values between 15.48 % and 15.70 % as compared to 17.28 % for the unoptimized provided layout. Each of the layouts found were different, but all layouts exhibited similar characteristics. Strong similarities across all the layouts include tightly packing wind turbines along the outer borders, loosely spacing turbines in the internal regions, and allocating similar numbers of turbines to each discrete boundary region. The best layout by AEP was found using a new sequential allocation method, discreet exploration-based optimization (DEBO). Based on the results in this study, it appears that using an optimization algorithm can significantly improve wind farm performance, but there are many optimization methods that can perform well on the wind farm layout optimization problem given that they are applied correctly.


  • Open Access

    Gradient-Based Wind Farm Layout Optimization Results Compared with Large-Eddy Simulations

    by Jared J. Thomas, Christopher J. Bay, Andrew P. J. Stanley, Andrew Ning

    The physics models commonly used during wind farm layout optimization include simplifying assumptions that can alter the design space compared to reality and higher-fidelity simulations. Some characteristics of these simple models may negatively influence the resulting layouts. In this paper, we perform wind farm layout optimization using a simple engineering wake model and then simulate the base and optimized layouts using large-eddy simulation (LES) to confirm that the layout was actually improved and not just an artifact of the simplifying assumptions in the low-fidelity wind farm simulation. We begin by describing the physics models used, including changes specific for use with gradient-based optimization. We then compare the simple model's output to previously published model and LES results. Using the simple models described, we performed gradient-based wind farm layout optimization using exact gradients. We optimized the wind farm twice, with high- and low-turbulence intensity (TI), respectively. We then recalculated annual energy production (AEP) using LES for the original and optimized layouts in each TI scenario and compared the results. For the high-TI case, the simple model predicted an AEP improvement of 7.7 %, while the LES reported 9.3 %. For the low-TI case, the simple model predicted a 10.0 % AEP improvement, while the LES reported 10.7 %. We concluded that the improvements found by optimizing with the simple model are not just an artifact of the model, but are real improvements assuming appropriate wind rose fidelity. We also found that the optimization did take advantage of the number of wind directions used, often aligning wind turbines in directions that were not included in the simulation. We found that, for the case studied, at least 50 wind directions are needed to avoid having the number of wind directions in the optimization significantly impact the optimized results. Future work should investigate further LES comparisons and wind rose fidelity in wind speed.


  • Open Access

    Wake expansion continuation: Multi‐modality reduction in the wind farm layout optimization problem

    by Jared J. Thomas, Spencer McOmber, Andrew Ning

    In this paper we present a continuation optimization method for reducing multi‐modality in the wind farm layout optimization problem that we call wake expansion continuation (WEC). We achieve the reduction in multi‐modality by starting with an increased wake diameter while maintaining normal velocity deficits at the center of the wakes, and then reducing the wake diameter for each of a series of optimization runs until the accurate wake diameter is used. We applied and demonstrated the effectiveness of WEC with two different wake models. We tested WEC on four optimization case studies and compared the results with a gradient‐based optimization method and a gradient‐free optimization method. We found a significant improvement in the mean, standard deviation, and minimum wake loss for optimization with WEC compared to optimization without WEC for all test cases. We found the gradient‐free optimization algorithm resulted in less optimal layouts on average for all cases than the gradient‐based algorithm with WEC. We also applied WEC to the gradient‐free algorithm for one case study with significantly improved results, but there was more improvement when we applied WEC to a gradient‐based algorithm. WEC enables gradient‐based algorithms to search the wind farm layout optimization space more globally and provides more optimal results more consistently than optimization without WEC.