ISIrawan Sukma

Irawan Sukma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Irawan Sukma has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Design and development of automatic voltage regulator using Ziegler-Nichols PID for electrical irons testing

    by Irawan Sukma, Aji Dwi Suseno, Muhidin Muhidin, Prayoga Bakti, Wuwus Ardiatna, Ihsan Supono, Himma Firdaus, Dwi Mandaris

    This research presents an automated voltage regulation system crucial for a power input test of electric irons based on SNI IEC 60335-2-3 clause 11.4. The system is designed with an Arduino-based proportional-integral-derivative (PID) control mechanism to augment voltage stability and meet the standard requirement. The system comprises a microcontroller for PID control, a dimmer as the actuator, and a voltage sensor for error measurement. It utilizes the Ziegler-Nichols (Z-N) oscillation method to determine the PID control parameters. The simulation results identified a third-order transfer function as the best fit for the system, and the optimal PID parameters for the system are Kp=60, Ki=125, and Kd=500. The system was tested under the electric iron's active and non-active conditions. The proposed PID system demonstrated stable responses, effectively regulating the system voltage with minimal overshoot and settling time, and meeting standard requirements even under varying load conditions. It suggests potential applications beyond electric iron testing, promising efficiency improvements in broader household product testing.


  • Meta-analysis correlation between temperature and rapid diagnostic test effectiveness: A systematic review on risk factor

    by Novitasari, Irawan Sukma, Paula Lihawa, Nurdina Gita Pratiwi, Siddiq Wahyu Hidayat, Dwi Mandaris, Wuwus Ardiatna, Asep Rahmat Hidayat

    The quality of rapid diagnostic tests (RDT) is very important and affects prevention and further plans for confirmatory laboratory tests. The standards applied The quality of rapid diagnostic tests (RDT) is very important and affects prevention and further plans for confirmatory laboratory tests. The standards applied

  • Performance reading by the classification of low-cost pulse oximeter in Indonesian market

    by Vera Permatasari, Khusnul Khotimah, Irawan Sukma, Siddiq Wahyu Hidayat, Asep Rahmat Hidayat

    The performance reading of eleven low-cost pulse oximeter brands to monitor the oxygen saturation level of Covid-19 home care patients widely used in the Indone The performance reading of eleven low-cost pulse oximeter brands to monitor the oxygen saturation level of Covid-19 home care patients widely used in the Indone

  • Measurement of specific absorption rate of wearable wireless devices

    by Wuwus Ardiatna, Haryo Dwi Prananto, Irawan Sukma, Iput Kasiyanto, Aditia Nur Bakti, Ihsan Supono, Priyo Wibowo, R. Harry Arjadi

    Wearable wireless devices, such as healthcare and the Internet of Things (IoT) have potentially a risky effect on the human body by electromagnetic radiation. T Wearable wireless devices, such as healthcare and the Internet of Things (IoT) have potentially a risky effect on the human body by electromagnetic radiation. T


  • Open Access

    Real-time wireless temperature measurement system of infant incubator

    by Irawan Sukma, Wuwus Ardiatna, Novitasari Novitasari, Vera Permatasari, Siddiq Wahyu Hidayat, Asep Rahmat Hidayat, Khusnul Khotimah, Ihsan Supono

    The internet of things (IoT) has allowed for ubiquitous measurement. Infant incubator temperature is one of crucial parts that need to be measured, especially for the stability and uniformity temperature. Based on the interpretation of IEC 60601-2-19, we proposed measurement method using IoT with the message queue telemetry transport (MQTT). In the 10,000 packet, the result shows the quality of service (QoS) level 2 of the system has the highest delay, however it has the lowest packet loss data than the other QoS. For 1 hour, the uniformity result and stability can fulfill the standards. Uniformity of 32°C, the lowest difference is point C with 0.32 °C, and the highest difference is point B with 0.75 °C. Uniformity of 36 °C, the lowest difference is point B with 0.27 °C, and the highest difference is point C with 0.79 °C. The stability of 32 °C and 36 °C is 0.32 °C and 0.44 °C, respectively. Moreover, the Kruskal Wallis test shows the highest difference average from point M is point A and B. It occurred because of the point A and B located far from the heater part, so the point A and B colder than point C.


  • Comparison Topologies of Resonant Tank from Class-C Wireless Power Transfer

    by Irawan Sukma, Akio Kitagawa

    In this paper shows modified circuit of class-c amplifier as transmitter part and comparison of four resonant tank topologies as state of the art. The circuit design and power efficiency calculation using LTspice simulation software. The transmitter circuit is consist of 5 volt as input voltage, class-c amplifier, modified circuit LTC6992 as a gate drive n-mosfet and resonant tank. On the other hand, the receiver circuit consist of resonant tank, full wave rectifier with diode schottky which is a high efficiency diode and resistor variable as load which the value changed from 1 to 2,kΩ. The result shows resonant tank parallel in transmitter and series in receiver has the highest power efficiency and output voltage compared to the other topology with value 32.74% when resistance around 63, Ω and coupling coefficient 0.99. In addition the circuit design has resonant frequency transmitter and receiver in 250 kHz which included in power matters alliance regulation and broadband wireless forum Japan guidelines.


  • Open Access

    Simple Design of Transmitter Circuit and Optimization Design of Receiver Circuit for Wireless Power Transfer

    by I Sukma, S. W Hidayat, A. R Hidayat, I Supono

    Two important parts of wireless power transfer are transmitter circuit and receiver circuit. Previous research has been completed which use CMOS H-Bridge in transmitter and full wave rectifier in receiver. This paper presented simple design of transmitter circuit and optimization of receiver circuit in rectifier circuit with transient analysis and Fast Fourier Transform (FFT) from LT spice software. The simple transmitter circuit used an integrated circuit (IC) NE555 with push-pull as oscillator circuit and LC resonant, while the receiver circuit used LC resonant, rectifier circuit, CLC filter for smoothing direct current (DC) output and 500 Ohm as load. The circuit design had resonant frequency of 250 kHz on both of transmitter and receiver, which comply with Power Matters Alliance (PMA) standard. The optimization of rectifier circuit had been done by comparing output of power load when it used basic rectifier (full wave), voltage doubler (dickson circuit and Villard circuit) and voltage multiplier (cockcroft-walton circuit). The results showed the receiver with Dickson circuit as rectifier has the highest efficiency compared to other rectifier circuits with efficiency of 10.93 % when it used coupling coefficient of 0.99, because Dickson rectifier has resonant frequency that is closest to 250 kHz and the highest level power, compared to other rectifier circuits.


  • Design and simulation of 145 kHz wireless power transfer for low power application

    by Irawan Sukma, Ihsan Supono

    Inductive resonance coupling is one of wireless power transfer technique. This paper presents a wireless power transfer design using inductive coupling which comply to the requirement of the wireless power consortium (WPC) standards in the resonant frequency range of 110 ~ 205 kHz. The circuit design and simulation have been conducted using a powerful and free LTspice simulation software with fast fourier transform (FFT) and directive analysis. Transmitter circuit based on royer oscillator circuit and receiver circuit has full wave rectifier, CLC Alter and load of 100 ohm. The result from experiments are the resonant frequency of circuit design of 145 kHz based on the calculation and 142.66 kHz based on the simulation. The difference between the two resonant frequency is caused by the components used in circuit, such as resistance of inductor (RL) transmitter and receiver 0.1 ohm giving resonant frequency 142.66 kHz which close to 145 kHz. Furthermore, the design circuit cannot reach maximum power efficiency when k close to 1, but the designed circuit can result maximum efficiency of 8.14 % when coupling coefficient (k) is 0.90 and the Rl 0.1 ohm.