Dwi Mandaris
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dwi Mandaris has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
- Frank Leferink
University of Twente
9 shared publications - Hutomo Wahyu Nugroho
National Research and Innovation Agency
4 shared publications - Yoppy Yoppy
National Research and Innovation Agency
4 shared publications - Aditia Nur Bakti
National Research and Innovation Agency
3 shared publications - Elvina Trivida
National Research and Innovation Agency
3 shared publications Robert Vogt-Ardatjew
University of Twente, Enschede, The Netherlands
3 shared publications
Latest Publications
- Open Access
Real-Time Vehicle Emergency Braking Detection with Moving Average Method Based on Accelerometer and Gyroscope Data
Emergency braking detection plays a vital role in enhancing road safety by identifying potentially hazardous driving behaviors. While existing methods rely heavily on artificial intelligence and computationally intensive algorithms, this paper proposes a lightweight, real-time algorithm for distinguishing emergency braking from non-emergency events using accelerometer and gyroscope signals. The proposed approach applies magnitude calculations and a moving average filters algorithm to preprocess inertial data collected from a six-axis IMU sensor. By analyzing peak values of acceleration and angular velocity, the algorithm successfully separates emergency braking from other events such as regular braking, passing over speed bumps, or traversing damaged roads. The results demonstrate that emergency braking exhibits a unique short-pulse pattern in acceleration and low angular velocity, distinguishing it from other high-oscillation disturbances. Furthermore, varying the window length of the moving average impacts classification accuracy and computational cost. The proposed method avoids the complexity of neural networks while retaining high detection accuracy, making it suitable for embedded and real-time vehicular systems, such as early warning applications for fleet management.
Open AccessReal-Time Vehicle Emergency Braking Detection with Moving Average Method Based on Accelerometer and Gyroscope Data
Emergency braking detection plays a vital role in enhancing road safety by identifying potentially hazardous driving behaviors. While existing methods rely heavily on artificial intelligence and computationally intensive algorithms, this paper proposes a lightweight, real-time algorithm for distinguishing emergency braking from non-emergency events using accelerometer and gyroscope signals. The proposed approach applies magnitude calculations and a moving average filters algorithm to preprocess inertial data collected from a six-axis IMU sensor. By analyzing peak values of acceleration and angular velocity, the algorithm successfully separates emergency braking from other events such as regular braking, passing over speed bumps, or traversing damaged roads. The results demonstrate that emergency braking exhibits a unique short-pulse pattern in acceleration and low angular velocity, distinguishing it from other high-oscillation disturbances. Furthermore, varying the window length of the moving average impacts classification accuracy and computational cost. The proposed method avoids the complexity of neural networks while retaining high detection accuracy, making it suitable for embedded and real-time vehicular systems, such as early warning applications for fleet management.
- Open Access
- 1 April 2025
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 14 (2) , 912-919
Electromagnetic interference risk from electrostatic discharge in infant incubators
This paper proposes an improved electromagnetic compatibility (EMC) risk analysis approach for medical equipment related to the effect of electrostatic discharge (ESD). This approach not only focuses on the risk of ESD from the susceptibility aspect but also investigates its conducted electromagnetic interference (EMI) characteristics. This study combines the standardized ESD test and conducted emission (CE) measurement simultaneously, applying it to the infant incubator and analyzing the spectrum of ESD current in the phase line in the time and frequency domain. The result shows that an ESD exposure caused current spikes with an average level of 13.8 A. Moreover, it also causes a broad spectral CE noise on the phase line of the infant incubator. Furthermore, the CE noise in the low-frequency range was also detected on the phase line during ESD exposure, indicating the risk of interference with other sensitive medical equipment connected to the same power network. The approach of proposed risk analysis in this study can be used to identify the risks of EMI due to ESD events in implementing the latest IEC 60601-1-2.
- 1 April 2025
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 14 (2) , 912-919
Open AccessElectromagnetic interference risk from electrostatic discharge in infant incubators
This paper proposes an improved electromagnetic compatibility (EMC) risk analysis approach for medical equipment related to the effect of electrostatic discharge (ESD). This approach not only focuses on the risk of ESD from the susceptibility aspect but also investigates its conducted electromagnetic interference (EMI) characteristics. This study combines the standardized ESD test and conducted emission (CE) measurement simultaneously, applying it to the infant incubator and analyzing the spectrum of ESD current in the phase line in the time and frequency domain. The result shows that an ESD exposure caused current spikes with an average level of 13.8 A. Moreover, it also causes a broad spectral CE noise on the phase line of the infant incubator. Furthermore, the CE noise in the low-frequency range was also detected on the phase line during ESD exposure, indicating the risk of interference with other sensitive medical equipment connected to the same power network. The approach of proposed risk analysis in this study can be used to identify the risks of EMI due to ESD events in implementing the latest IEC 60601-1-2.
- Open Access
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 13 (6) , 3938-3947
Design and development of automatic voltage regulator using Ziegler-Nichols PID for electrical irons testing
This research presents an automated voltage regulation system crucial for a power input test of electric irons based on SNI IEC 60335-2-3 clause 11.4. The system is designed with an Arduino-based proportional-integral-derivative (PID) control mechanism to augment voltage stability and meet the standard requirement. The system comprises a microcontroller for PID control, a dimmer as the actuator, and a voltage sensor for error measurement. It utilizes the Ziegler-Nichols (Z-N) oscillation method to determine the PID control parameters. The simulation results identified a third-order transfer function as the best fit for the system, and the optimal PID parameters for the system are Kp=60, Ki=125, and Kd=500. The system was tested under the electric iron's active and non-active conditions. The proposed PID system demonstrated stable responses, effectively regulating the system voltage with minimal overshoot and settling time, and meeting standard requirements even under varying load conditions. It suggests potential applications beyond electric iron testing, promising efficiency improvements in broader household product testing.
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 13 (6) , 3938-3947
Open AccessDesign and development of automatic voltage regulator using Ziegler-Nichols PID for electrical irons testing
This research presents an automated voltage regulation system crucial for a power input test of electric irons based on SNI IEC 60335-2-3 clause 11.4. The system is designed with an Arduino-based proportional-integral-derivative (PID) control mechanism to augment voltage stability and meet the standard requirement. The system comprises a microcontroller for PID control, a dimmer as the actuator, and a voltage sensor for error measurement. It utilizes the Ziegler-Nichols (Z-N) oscillation method to determine the PID control parameters. The simulation results identified a third-order transfer function as the best fit for the system, and the optimal PID parameters for the system are Kp=60, Ki=125, and Kd=500. The system was tested under the electric iron's active and non-active conditions. The proposed PID system demonstrated stable responses, effectively regulating the system voltage with minimal overshoot and settling time, and meeting standard requirements even under varying load conditions. It suggests potential applications beyond electric iron testing, promising efficiency improvements in broader household product testing.
- Open Access
- 1 February 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (1) , 166-174
Passive magnetic coil design for electromagnetic interference evaluation of axle counters
Measurement of magnetic fields near the railway tracks is crucial to ensure compatibility with the operation of axle counters. According to EN 50592 standard, the magnetic field is detected with a passive magnetic coil and an oscilloscope. From previous studies, in general, there has been no in-depth analysis of how the choice of coil winding parameters could affect the coil output voltage, which then affect the measurement sensitivity, in particular the coil design based on the standard and it is applicability for electromagnetic interference (EMI) evaluation of axle counters. Therefore, this paper will explore the design of a passive magnetic coil to obtain the optimum coil output voltage within the frequency range. Simulations showed that for 10-100 kHz and 100 kHz–1.3 MHz range, the optimum number of turns happened at 60-100 and 15-60 turns, respectively. Based on that, two example coils had been built. Simulations and measurements of their frequency response were in good agreement, with a deviation less than 1.0 dB.
- 1 February 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 14 (1) , 166-174
Open AccessPassive magnetic coil design for electromagnetic interference evaluation of axle counters
Measurement of magnetic fields near the railway tracks is crucial to ensure compatibility with the operation of axle counters. According to EN 50592 standard, the magnetic field is detected with a passive magnetic coil and an oscilloscope. From previous studies, in general, there has been no in-depth analysis of how the choice of coil winding parameters could affect the coil output voltage, which then affect the measurement sensitivity, in particular the coil design based on the standard and it is applicability for electromagnetic interference (EMI) evaluation of axle counters. Therefore, this paper will explore the design of a passive magnetic coil to obtain the optimum coil output voltage within the frequency range. Simulations showed that for 10-100 kHz and 100 kHz–1.3 MHz range, the optimum number of turns happened at 60-100 and 15-60 turns, respectively. Based on that, two example coils had been built. Simulations and measurements of their frequency response were in good agreement, with a deviation less than 1.0 dB.
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3069 (1) , 020119
Meta-analysis correlation between temperature and rapid diagnostic test effectiveness: A systematic review on risk factor
The quality of rapid diagnostic tests (RDT) is very important and affects prevention and further plans for confirmatory laboratory tests. The standards applied The quality of rapid diagnostic tests (RDT) is very important and affects prevention and further plans for confirmatory laboratory tests. The standards applied
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3069 (1) , 020119
Meta-analysis correlation between temperature and rapid diagnostic test effectiveness: A systematic review on risk factor
The quality of rapid diagnostic tests (RDT) is very important and affects prevention and further plans for confirmatory laboratory tests. The standards applied The quality of rapid diagnostic tests (RDT) is very important and affects prevention and further plans for confirmatory laboratory tests. The standards applied
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3069 (1) , 020122
Evaluation of fast transient electromagnetic interference to medical equipment susceptibility
Electromagnetic Compatibility (EMC) testing on electronic medical equipment is very essential to ensure its quality and safety. This testing is particularly imp Electromagnetic Compatibility (EMC) testing on electronic medical equipment is very essential to ensure its quality and safety. This testing is particularly imp
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3069 (1) , 020122
Evaluation of fast transient electromagnetic interference to medical equipment susceptibility
Electromagnetic Compatibility (EMC) testing on electronic medical equipment is very essential to ensure its quality and safety. This testing is particularly imp Electromagnetic Compatibility (EMC) testing on electronic medical equipment is very essential to ensure its quality and safety. This testing is particularly imp
- Open Access
- 1 October 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 12 (5) , 4632-4639
Electromagnetic interference measurement for axle counters light rapid transit railway in Indonesia
The measurement and analysis of electromagnetic interference (EMI) from light rapid transit (LRT) axle counters against magnetic field interference in Indonesia has been carried out. The low-cost magnetic sensors were developed according to the British Standard (BS) EN 50592:2016. The measurement setup and magnetic field limit were based on the British Standard EN 50592:2016 and ERA/ERTMS/033281 standard. Two frequency range of the measurements, lower and higher frequencies with two different train running mode, acceleration mode and deceleration mode were applied in this research. The results in lower frequency range (10 to 100 kHz) were very close to the limit value in both acceleration and deceleration mode, especially at the 30 to 50 kHz for the y and z directions. Although there may possibly magnetic interference at low frequencies, most of the magnetic field emissions were still in acceptable range.
- 1 October 2022
- Published by Institute of Advanced Engineering and Science in International Journal of Electrical and Computer Engineering (IJECE)
- Vol. 12 (5) , 4632-4639
Open AccessElectromagnetic interference measurement for axle counters light rapid transit railway in Indonesia
The measurement and analysis of electromagnetic interference (EMI) from light rapid transit (LRT) axle counters against magnetic field interference in Indonesia has been carried out. The low-cost magnetic sensors were developed according to the British Standard (BS) EN 50592:2016. The measurement setup and magnetic field limit were based on the British Standard EN 50592:2016 and ERA/ERTMS/033281 standard. Two frequency range of the measurements, lower and higher frequencies with two different train running mode, acceleration mode and deceleration mode were applied in this research. The results in lower frequency range (10 to 100 kHz) were very close to the limit value in both acceleration and deceleration mode, especially at the 30 to 50 kHz for the y and z directions. Although there may possibly magnetic interference at low frequencies, most of the magnetic field emissions were still in acceptable range.
- Open Access
- 27 July 2021
- Published by Center for Research and Development of Standardization and Conformity Assessment in Instrumentasi
- Vol. 45 (1) , 21-39
Electromagnetic Test Environments Analysis for EMI Measurements
Electromagnetic Test Environments Analysis for EMI Measurements
- 27 July 2021
- Published by Center for Research and Development of Standardization and Conformity Assessment in Instrumentasi
- Vol. 45 (1) , 21-39
Open AccessElectromagnetic Test Environments Analysis for EMI Measurements
Electromagnetic Test Environments Analysis for EMI Measurements
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 674-679
Different Test Site Analysis of Radiated Field Measurements of a Complex EUT
The goal of the COST IC1407 Action is to investigate the radiated emission characteristics in densely integrated technologies. One of the promising techniques for this application is the Near Field Scanning (NFS), as it allows to measure the near field intensity with a very high resolution, which is especially useful for tracking down critical components, even on a board level. The results can additionally be translated to the far field equivalents, comparable with the conventional emissions measurement standards. In this study, we investigate this technique with respect to another, commonly recognized emission measurement techniques, such as semi-anechoic chamber (SAC), fully anechoic room (FAR), gigahertz transverse-electromagnetic (GTEM) cell, and reverberation chamber (RC). As opposed to classical round-robin tests, where a simple reference radiator is measured, in order to increase the harshness of our tests, we used as a test sample with very complex, unpredictable and unstable behavior, an Intel Galileo board- a perfect example of real equipment.
- 1 September 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 674-679
Different Test Site Analysis of Radiated Field Measurements of a Complex EUT
The goal of the COST IC1407 Action is to investigate the radiated emission characteristics in densely integrated technologies. One of the promising techniques for this application is the Near Field Scanning (NFS), as it allows to measure the near field intensity with a very high resolution, which is especially useful for tracking down critical components, even on a board level. The results can additionally be translated to the far field equivalents, comparable with the conventional emissions measurement standards. In this study, we investigate this technique with respect to another, commonly recognized emission measurement techniques, such as semi-anechoic chamber (SAC), fully anechoic room (FAR), gigahertz transverse-electromagnetic (GTEM) cell, and reverberation chamber (RC). As opposed to classical round-robin tests, where a simple reference radiator is measured, in order to increase the harshness of our tests, we used as a test sample with very complex, unpredictable and unstable behavior, an Intel Galileo board- a perfect example of real equipment.
- 1 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1018-1023
Implementation of IEC 61000-4-2 Standard Testing Under Tropical Humidity for Recommendation to Amendment of International Standards
Humidity is one of the essential environmental factors that can affect the performance of electronic appliances. The yearly average of relative humidity in tropical countries, such as Indonesia, is higher than in subtropical countries. The data shows that the average relative humidity in 11 major cities in Indonesia from 2016-2017 is above 70%. Some IEC standards set different testing requirements for tropical and non-tropical climate condition. IEC 61000-4-2 as a standard for electrostatic discharge (ESD) immunity test only set a single range of relative humidity, 30% to 60%, as the climatic condition requirement. Although this requirement can be applied in the testing laboratory, however, this does not match with the actual climate condition in Indonesia as a tropical country. This paper investigates the effect of relative humidity in air discharge ESD testing to the performance of DVD-Player as the equipment under test (EUT). The measurement showed that the EUT experienced faster initial performance degradation in higher relative humidity. The finding result is expected to provide input to the ESD standard.
- 1 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1018-1023
Implementation of IEC 61000-4-2 Standard Testing Under Tropical Humidity for Recommendation to Amendment of International Standards
Humidity is one of the essential environmental factors that can affect the performance of electronic appliances. The yearly average of relative humidity in tropical countries, such as Indonesia, is higher than in subtropical countries. The data shows that the average relative humidity in 11 major cities in Indonesia from 2016-2017 is above 70%. Some IEC standards set different testing requirements for tropical and non-tropical climate condition. IEC 61000-4-2 as a standard for electrostatic discharge (ESD) immunity test only set a single range of relative humidity, 30% to 60%, as the climatic condition requirement. Although this requirement can be applied in the testing laboratory, however, this does not match with the actual climate condition in Indonesia as a tropical country. This paper investigates the effect of relative humidity in air discharge ESD testing to the performance of DVD-Player as the equipment under test (EUT). The measurement showed that the EUT experienced faster initial performance degradation in higher relative humidity. The finding result is expected to provide input to the ESD standard.