FLFeng Li

Feng Li

*This is an algorithmically generated author record based on publicly available information.

Feng Li has a total of 26 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Research on the Optimization of Urban Electric Heating Hydrogen Integrated Energy System Under Carbon Pricing Mechanism: A Case Study of Guangzhou City

    by Yao Duan, Chong Gao, Feng Li, Guotian Cai, Donghong Wu, Songyan Ren

    This study establishes an urban-scale integrated energy system model, innovatively incorporating carbon emission cost constraints. Utilizing a source-load-storage collaborative planning approach, the research quantitatively evaluates the interplay between hydrogen energy penetration and carbon pricing policies on system evolution. A dynamic optimization algorithm is employed to identify the cost-minimal development pathway. Results reveal that a 30% increase in photovoltaic capacity and a 50% expansion in biomass power generation reduce annual system carbon emission intensity by 1.3 basis points, highlighting the decarbonization potential of renewable energy scaling. Hydrogen-based transportation substitution for fuel vehicles contributes 2.7% of the system’s total CO2 reduction through full lifecycle emission savings. At a carbon price of 140 yuan/ton CO2, market-driven energy structure optimization enhances renewable utilization by 11.2 percentage points, achieving a 0.3% annual reduction in societal emissions (equating to 297,000 tons). However, this scenario induces a 5% rise in end-user energy costs (approximately 530,000 yuan annually), underscoring the critical balance between decarbonization and economic viability. The study demonstrates that urban energy system planning must integrate dual objectives of carbon constraints and cost efficiency. Policy incentives are coupled with technological cost reductions in environmental and economic performance. This study provides quantitative evidence to guide low-carbon transition strategies for municipal energy systems.

  • Open Access

    Topology Selection for Large-Scale Offshore Wind Power HVDC Direct Transmission to Load Centers: Influencing Factors and Construction Principles

    by Lang Liu, Feng Li, Danqing Chen, Shuxin Luo, Hao Yu, Honglin Chen, Guoteng Wang, Ying Huang

    The development and utilization of large-scale offshore wind power (OWP) are critical measures for achieving global energy transition. To address the demands of future large-scale OWP centralized development and transmission, this study systematically investigates the influencing factors and construction principles for topology selection in offshore wind power high-voltage direct current (HVDC) transmission systems delivering power to load centers. First, under the context of expanding the offshore wind power transmission scale, the necessity of transmitting OWP via HVDC overhead lines directly to load centers after landing is theoretically discussed. Five key topological influencing factors are then analyzed: offshore wind power collection schemes, multi-terminal HVDC network configurations, DC fault isolation mechanisms, offshore converter station architectures, and voltage source converter HVDC (VSC-HVDC) receiving terminal landing modes. Corresponding topology construction principles for direct HVDC transmission to load centers are proposed to guide system design. Finally, the feasibility of the proposed principles is validated through a case study of a multi-terminal HVDC system integrated into an actual regional power grid, demonstrating practical applicability.

  • Open Access

    Black-Start Strategy for Offshore Wind Power Delivery System Based on Series-Connected DRU-MMC Hybrid Converter

    by Feng Li, Danqing Chen, Honglin Chen, Shuxin Luo, Hao Yu, Tian Hou, Guoteng Wang, Ying Huang

    The series-connected DRU-MMC hybrid converter, with its compact size and cost-effectiveness, presents an attractive solution for long-distance offshore wind power transmission. However, its application is limited by the DRU’s unidirectional power flow and the voltage mismatch between the auxiliary MMC and the onshore MMC during black-start operations. To overcome these challenges, a four-stage black-start strategy utilizing an auxiliary step-down transformer connected to the onshore MMC is proposed. The proposed strategy operates as follows: The onshore MMC first lowers its valve-side voltage via an auxiliary transformer, enabling reduced DC-side voltage. With the DRU bypassed, the offshore MMC draws startup power through the DC link, then switches to V/f mode with wind turbine curtailment to reduce DC current below the DRU bypass threshold. After stable, low-power operation, the DRU is integrated. The onshore MMC then restores rated DC voltage and disconnects the transformer, allowing gradual wind turbine reconnection to complete black-start. The simulation results confirm the approach’s feasibility under conditions where all wind turbines operate in grid-following mode.


  • Open Access

    Power Flow Optimization and Economic Analysis Based on High Voltage Phase Shifting Transformer

    by Mengze Yu, Jiaxin Yuan, Zuohong Li, Feng Li, Xinyi Yang, Weizhe Zhang, Shunkai Xu, Jiajun Mei

    With the development of power systems, the power flow problem of transmission line is becoming more and more prominent. This paper presents a power flow regulation method based on phase shifting transformer (PST). Firstly, the working principle and performance of PST are analyzed. Then, the simulation model of BPA multi node system is established. PST access reduces the line imbalance to less than 8%. On this basis, considering the influence of saturation effect and leakage reactance, a PST suitable for 220 kV power grid is designed. Three different working conditions are simulated by PSCAD software. Under normal working conditions and N-1 conditions, PST can increase the transmission limit of the ring network section by more than 20%. When a short-circuit fault occurs, PST can also suppress the fault current. For 220 kV practical projects, unified power flow controller (UPFC) has faster response speed and stronger performance, but PST is more economical and reliable, and the equipment cost is 49.86% lower than that of UPFC. The power flow regulation method based on PST has good steady-state effect. It can improve the utilization efficiency of power grid assets and optimize the power flow distribution in a short time and at low cost.


  • Open Access

    Optimal Dynamic Reactive Power Reserve for Wind Farms Addressing Short-Term Voltage Issues Caused by Wind Turbines Tripping

    by Liang Wu, Lin Guan, Feng Li, Qi Zhao, Yingjun Zhuo, Peng Chen, Yaotang Lv

    In regional power grids with high wind power penetration, wind turbine tripping poses great challenges to short-term voltage stability. Dynamic reactive power (VAR) compensation (DVC) plays an important role in securing wind farm operation. To address short-term voltage stability issues, voltage disturbance index (DI) and voltage supporting index (SI) are defined to evaluate the degree of voltage fluctuation and voltage supporting ability of a bus, respectively. Then corresponding vector-type features, called disturbance vector (DV) and supporting vector (SV) are proposed based on the defined indexes. The Kendall rank correlation coefficient is adopted to evaluate the matching degree of DV and SV, so as to determine the influenced area of each wind farm. Candidate locations for DVC are determined sequentially. By comprehensively considering the probability of combined disturbance in each wind farm, a site selection method is proposed and then genetic algorithm is applied to optimize the DVC capacity considering short-term voltage security. The proposed method is applied on a modified NE 39-bus system and a real power grid. Comparison with the engineering practice-based method validates its effectiveness.