NONurmiza Othman

Nurmiza Othman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nurmiza Othman has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    IoT-based Automatic Pill Dispenser for Hyperlipidemia’s Patient

    by Chin Kang Zhe, Nurmiza Othman

    The elderly who stay at home alone, especially those with hyperlipidemia, would have problems taking their medicine if their medicine is too much with a different variety. The current market product that provides a pill dispensing service is costly with limited functionality; some require a monthly subscription fee and do not have passcode protection for safe use. This work proposed an innovative design of a prototype model of a pill dispenser for the elderly with IoT functionality. This prototype provides tolerance to the most general type of pills and hyperlipidemia-related pills in specific. The prototype employed the integration of hardware and software apparatus. The hardware components include the Durian UNO board, ESP8266 Wi-Fi transceiver module, stepper motor, RFID kit, temperature, humidity sensor, push button, solenoid door lock, buzzer and relay module. The hardware part will support different monitoring systems while sending the data through the Internet for real-time monitoring. Solid Work, Arduino IDE, Blynk Apps and Fritzing software will be utilized for the software. This prototype is intended to provide all the essential features while maintaining the moderate cost of the product. The proposed design can greatly reduce the error of taking the wrong medicine. The caregiver can access the surrounding temperature and humidity of the dispenser. Besides, they can know whether the user has taken the medicine and receive emergency notifications from the user.


  • Open Access

    Development of Non-Invasive Bilirubin Level Detector for Neonatal Jaundice in Rural Area

    by Nurmiza Othman, Vynnie Sophi Koon Tan, Shahnoor Shanta

    Neonatal jaundice is frequently seen in newborns and is caused by the elevated bilirubin levels due to the liver's underdevelopment and increased red blood cell breakdown. Left untreated, it can impair the central nervous system's development. Nowadays, clinicians use a transcutaneous bilimeter (TcB) or a total serum bilirubin (TSB) test to determine the bilirubin levels. The gold standard tool for measurement is the TSB, but the blood test can be expensive, time-consuming, and associated with pain and infection hazards. TcB enables non-invasive bilirubin measurement. However, it costs hundreds of dollars. Rural health clinics, especially those constructed more than 50 years ago, lacked healthcare technology. As a result, neither method is available in most rural clinics. Therefore, developing a non-invasive bilirubin level detector for neonatal jaundice in rural areas is crucial. This research proposes a cost-effective, non-invasive bilirubin detector tailored for rural areas. The device, built on an Arduino-based system, uses a blue LED and photodiode setup for bilirubin detection and a MAX30100 sensor module for oxygen saturation (SpO2) and heart rate (HR) monitoring. Experimental results confirm the device's accuracy in measuring bilirubin levels and monitoring SpO2 and HR within normal ranges. With its standalone functionality and user-friendly design, the device ensures reliable monitoring without requiring Internet access. This innovation provides an affordable solution for diagnosing and monitoring neonatal jaundice in resource-limited settings.

  • Open Access

    Fabrication of PDMS-Based Microdilution Chip using Masked Stereolithography (MSLA) 3D Printed Mold

    by Muhammad Al Aziim Noridin, Nurmiza Othman, Nurfarina Zainal, Fhong Soon Chin, Rangga Winantyo, Intan Sue Liana Abdul Hamid

    An alternative fabrication method for microdilution chips that address the limitations of traditional methods and ensures transparency, chemical resistance, and biocompatibility is presented in this paper. This work describes the design, fabrication, and characterization of the microdilution chip using mask stereolithography (MSLA) 3D printed mold. The microdilution chip fabrication uses the 3D printed mold for replication in the soft lithography method to produce the polydimethylsiloxane (PDMS)-based final chip. The height of the microdilution chip channel differs by 8% between the MSLA 3D printed mould and the design dimension in software and by 12% between the MSLA 3D printed mould and the PDMS-replicated microdilution chip. The MSLA 3D printer generates trustworthy resolution outputs with a channel width error margin of 50 μm. Two distinct pH solutions are used to successfully test the microdilution devices and show dilution for all outlets.

  • Open Access

    Polarization-Insensitive, High-Efficiency Metasurface with Wide Reception Angle for Energy Harvesting Applications

    by Abdulrahman Ahmed Ghaleb Amer, Nurmiza Othman, Mohammed M. Bait-Suwailamn, Syarfa Zahirah Sapuan, Ali Ahmed Ali Salem, Adeb Salh

    This research presents an innovative polarization-insensitive metasurface (MS) harvester designed for energy harvesting applications at 5 GHz, capable of operating efficiently over wide reception angles. The proposed MS features a novel wheel-shaped resonator array whose symmetrical structure ensures insensitivity to the polarization of incident electromagnetic (EM) waves, enabling efficient energy absorption and minimizing reflections. Unlike conventional designs, the metasurface achieves near-unity harvesting efficiency, exceeds 94% under normal incidence, and maintains superior performance across various incident angles for TE and TM polarizations. To validate the design, a 5 × 5-unit cell array of the MS structure was fabricated and experimentally tested, demonstrating excellent agreement between simulation and measurement results. This work significantly advances metasurface-based energy harvesting by combining polarization insensitivity, wide-angle efficiency, and high absorption, making it a compelling solution for powering wireless sensor networks in next-generation applications.


  • Open Access

    Polarization-Insensitive, High-Efficiency Metasurface with Wide Reception Angle for Energy Harvesting Applications

    by Abdulrahman Ahmed Ghaleb Amer, Nurmiza Othman, Mohammed M. Bait-Suwailamn, Syarfa Zahirah Sapuan, Ali Ahmed Ali Salem, Adeb Salh

    This research introduces a polarization-insensitive metasurface (MS) capable of wide reception angles, featuring an array of wheel resonators designed for energy harvesting applications at 5 GHz. The symmetrical structure of the proposed resonator enables it to be highly insensitive to the polarization of the incident wave, ensuring efficient absorption of electromagnetic (EM) power and significantly reducing reflections. This allows for the majority of the captured energy to be delivered to resistor loads. Simulation results demonstrate that the proposed MS structure achieves a higher absorptivity for various polarizations and incident angles. Furthermore, a near-unity harvesting efficiency exceeding 94% is obtained regardless of the polarization of the incident wave under normal incidence at 5 GHz. Moreover, a higher harvesting efficiency is observed across various incident angles for TE and TM polarization. A 5×5-unit cell array of the proposed MS structure is fabricated and experimentally tested to validate the concept. The simulation and experimental results exhibit good agreement. The proposed harvester demonstrates superior absorptivity and harvesting efficiency across various polarizations and incident angles, making it a strong candidate for energy harvesting systems in wireless sensor networks.

  • Open Access

    Dual-Band, Wide-Angle, and High-Capture Efficiency Metasurface for Electromagnetic Energy Harvesting

    by Abdulrahman Ahmed Ghaleb Amer, Nurmiza Othman, Syarfa Zahirah Sapuan, Arokiaswami Alphones, Mohd Fahrul Hassan, Ahmed Jamal Abdullah Al-Gburi, Zahriladha Zakaria

    A dual-band metasurface (MS) with a wide reception angle operating at Wi-Fi bands (2.4 GHz and 5.4 GHz) is presented for electromagnetic (EM) energy harvesting applications. The MS unit cell comprises a subwavelength circular split ring resonator printed on the low-loss substrate. An air layer is sandwiched between two low-loss substrates to enhance the harvesting efficiency at operating frequencies. One of the main advantages of the proposed MS is that it uses only one harvesting port (via) to channel the captured power to the optimized load (50 Ω), which simplifies the design of a combined power network. According to the results of full-wave EM simulations, the proposed MS has a near-unity efficiency of 97% and 94% at 2.4 GHz and 5.4 GHz, respectively, for capturing the power of incident EM waves with normal incidence. Furthermore, the proposed MS harvester achieves good performance at up to 60° oblique incidence. To validate simulations, the MS harvester with 5 × 5-unit cells is fabricated and tested, and its EM properties are measured, showing good agreement with the simulation results. Because of its high efficiency, the proposed MS harvester is suitable for use in various microwave applications, such as energy harvesting and wireless power transfer.


  • Open Access

    Development of hand gesture controlled robotic arm for hemiplegia patients

    by Wan Norliyana Wan Azlan, Wan Nurshazwani Wan Zakaria, Nurmiza Othman, Mohd Norzali Haji Mohd

    Hand gesture-controlled robotic arm is designed to improve the motor function of hemiplegic patients. In this paper, the Leap Motion sensor is the device utilized to collect data for hand gesture recognition. Therapists suggested a combination of wrist revolving rehabilitation exercises that can also be recognized by the Leap Motion sensor, which are: radial-ulnar deviation, flexion-extension, and grasping-releasing of the palm. This study focuses on the EMU HS4 3-DOF robotic arm usage to enable the robot in imitating the hemiplegic patient hand gesture movements. The Leap Motion sensor detects the patient’s functioning hand over the USB bus and sends data to the Leap Motion service on the host PC. Information is processed and sent to a running Leap-enabled application, Processing. Received data undergoes algorithm in Processing, and data is sent to Arduino IDE to move the robot motors as the output according to the hand input given. Normalization of hand, motor, and robot angle positions is crucial in standardizing the collected data. Three test subjects with healthy hands and of different gender and age commit the experiment to validate the system. The experimental results yield three training sessions with three sets of trials for each training. The average Leap Motion sensor and robot position output readings for the three training are recorded and analyzed. As a result, the robot gripper action obeys the desired grab strength by 100%. The yaw and pitch deviations show an RMSE of 3.31 degrees and 3.98 degrees respectively. This system has many potentials for future development and advancement, such as a 6-DOF robot arm implementation that can cater to the pronation and supination movements of the wrist. Also, hemiplegia patients should test on the system to contribute better feedback data and advise on improving the training sessions.

  • Open Access

    Analysis of Non-invasive Video Based Heart Rate Monitoring System obtained from Various Distances and Different Facial Spot

    by Norwahidah Ibrahim, Razali Tomari, Wan Nurshazwani Wan Zakaria, Nurmiza Othman

    Heart rate (HR) is one of the crucial indicators for human psychological. In recent works, it has been shown that a standard camera is able to detect illumination changes in the face skin due to the human cardiac pulse and this can be used to estimate the human HR. However most of previous systems work on near distance mode with a single face patch, thus the expediency of the camera based remote heart rate estimation for long range distances remains ambiguous. This paper has proposed a solution by analyzing an optimal framework that able to works properly under the mentioned issues. Initially, presumable facial landmarks are estimated by applying cascaded of regression mechanism. Then, the region of interest (ROI) was selected based on the facial landmarks in the location where non rigid motion is minimal. Temporal photoplethysmograph (PPG) signal is extracted from the ROI and the unwanted signal such as environment illumination signal or motion artifact signal is eliminated by using Independent Component Analysis (ICA) filter. Then, PPG signal is further processed using series of temporal filter to exclude frequencies outside the range of interest prior to estimate the HR. Since, the HR is estimated independently from multiple local regions, a histogram analysis is constructed to calculate the average HR estimation accurately. From the experiments, it can be concluded that the HR can be detected up to 5 meters range with 94% accuracy using full face region.