Gongfa Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gongfa Liu has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Chuan Li
National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, China
5 shared publicationsKe Xuan
Univ Sci & Technol China, Natl Synchrotron Radiat Lab, Hefei 230029, Anhui, Peoples R China
3 shared publications- Yuanji Pei
National Synchrotron Radiation Laboratory University of Science and Technology of China Hefei China
3 shared publications C. Li
Univ Sci & Technol China, Natl Synchrotron Radiat Lab, Hefei 230029, Anhui, Peoples R China
2 shared publicationsJi-Gang Wang
Univ Sci & Technol China, Natl Synchrotron Radiat Lab, Hefei 230029, Anhui, Peoples R China
2 shared publications- Ke Xuan
National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230029, China
2 shared publications
Latest Publications
- Open Access
- 23 January 2026
- Published by Association for Computing Machinery (ACM)
- p. 989-996
Novel design of safety interlock protection control system for beamlines at the Hefei Advanced Light Facility
- 23 January 2026
- Published by Association for Computing Machinery (ACM)
- p. 989-996
Open AccessNovel design of safety interlock protection control system for beamlines at the Hefei Advanced Light Facility
- Open Access
- 13 August 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (11) , e14115
Effect of metal implants and metal artifacts on back‐projected two‐dimensional entrance fluence determined by EPID dosimetry
Purpose: To evaluate the errors caused by metal implants and metal artifacts in the two‐dimensional entrance fluences reconstructed using the back‐projection algorithm based on electronic portal imaging device (EPID) images.Methods: The EPID in the Varian VitalBeam accelerator was used to acquire portal dose images (PDIs), and then commercial EPID dosimetry software was employed to reconstruct the two‐dimensional entrance fluences based on computed tomography (CT) images of the head phantoms containing interchangeable metal‐free/titanium/aluminum round bars. The metal‐induced errors in the two‐dimensional entrance fluences were evaluated by comparing the γ results and the pixel value errors in the metal‐affected regions. We obtained metal‐artifact‐free CT images by replacing the voxel values of non‐metal inserts with those of metal inserts in metal‐free CT images to evaluate the metal‐artifact‐induced errors.Results: The γ passing rates (versus PDIs obtained without a phantom in the beam field (PDIair), 2%/2 mm) for the back‐projected two‐dimensional entrance fluences of phantoms containing titanium or aluminum (BPTi/BPAl) were reduced from 92.4% to 90.5% and 90.6%, respectively, relative to the metal‐free phantom (BPmetal‐free). Titanium causes more severe metal artifacts in CT images than aluminum, and its removal resulted in a 0.0022 CU (median) reduction in the pixel value of BPTi artifact‐free relative to BPTi in the metal‐affected region. Moreover, the mean absolute error (MAE) and root mean square error (RMSE) decreased from 0.0050 CU and 0.0063 CU to 0.0034 CU and 0.0040 CU, respectively (vs. BPmetal‐free).Conclusion: Metal implants increase the errors in back‐projected two‐dimensional entrance fluences, and metals with higher electron densities cause more errors. For high‐electron‐density metal implants that produce severe metal artifacts (e.g., titanium), removing metal artifacts from the CT images can improve the accuracy of the two‐dimensional entrance fluences reconstructed by back‐projection algorithms.
- 13 August 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (11) , e14115
Open AccessEffect of metal implants and metal artifacts on back‐projected two‐dimensional entrance fluence determined by EPID dosimetry
Purpose: To evaluate the errors caused by metal implants and metal artifacts in the two‐dimensional entrance fluences reconstructed using the back‐projection algorithm based on electronic portal imaging device (EPID) images.Methods: The EPID in the Varian VitalBeam accelerator was used to acquire portal dose images (PDIs), and then commercial EPID dosimetry software was employed to reconstruct the two‐dimensional entrance fluences based on computed tomography (CT) images of the head phantoms containing interchangeable metal‐free/titanium/aluminum round bars. The metal‐induced errors in the two‐dimensional entrance fluences were evaluated by comparing the γ results and the pixel value errors in the metal‐affected regions. We obtained metal‐artifact‐free CT images by replacing the voxel values of non‐metal inserts with those of metal inserts in metal‐free CT images to evaluate the metal‐artifact‐induced errors.Results: The γ passing rates (versus PDIs obtained without a phantom in the beam field (PDIair), 2%/2 mm) for the back‐projected two‐dimensional entrance fluences of phantoms containing titanium or aluminum (BPTi/BPAl) were reduced from 92.4% to 90.5% and 90.6%, respectively, relative to the metal‐free phantom (BPmetal‐free). Titanium causes more severe metal artifacts in CT images than aluminum, and its removal resulted in a 0.0022 CU (median) reduction in the pixel value of BPTi artifact‐free relative to BPTi in the metal‐affected region. Moreover, the mean absolute error (MAE) and root mean square error (RMSE) decreased from 0.0050 CU and 0.0063 CU to 0.0034 CU and 0.0040 CU, respectively (vs. BPmetal‐free).Conclusion: Metal implants increase the errors in back‐projected two‐dimensional entrance fluences, and metals with higher electron densities cause more errors. For high‐electron‐density metal implants that produce severe metal artifacts (e.g., titanium), removing metal artifacts from the CT images can improve the accuracy of the two‐dimensional entrance fluences reconstructed by back‐projection algorithms.
- Open Access
- 24 April 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (8) , e14004
Improving synthetic CT accuracy by combining the benefits of multiple normalized preprocesses
Purpose: To investigate the effect of different normalization preprocesses in deep learning on the accuracy of different tissues in synthetic computed tomography (sCT) and to combine their advantages to improve the accuracy of all tissues.Methods: The cycle‐consistent adversarial network (CycleGAN) model was used to generate sCT images from megavolt cone‐beam CT (MVCBCT) images. In this study, 2639 head MVCBCT and CT image pairs from 203 patients were collected as a training set, and 249 image pairs from 29 patients were collected as a test set. We normalized the voxel values in images to 0 to 1 or −1 to 1, using two linear and five nonlinear normalization preprocessing methods to obtain seven data sets and compared the accuracy of different tissues in different sCT obtained from training these data. Finally, to combine the advantages of different normalization preprocessing methods, we obtained sCT_Blur by cropping, stitching, and smoothing (OpenCV's cv2.medianBlur, kernel size 5) each group of sCTs and evaluated its image quality and accuracy of OARs.Results: Different normalization preprocesses made sCT more accurate in different tissues. The proposed sCT_Blur took advantage of multiple normalization preprocessing methods, and all tissues are more accurate than the sCT obtained using a single conventional normalization method. Compared with other sCT images, the structural similarity of sCT_Blur versus CT was improved to 0.906 ± 0.019. The mean absolute errors of the CT numbers were reduced to 15.7 ± 4.1 HU, 23.2 ± 7.1 HU, 11.5 ± 4.1 HU, 212.8 ± 104.6 HU, 219.4 ± 35.1 HU, and 268.8 ± 88.8 HU for the oral cavity, parotid, spinal cord, cavity, mandible, and teeth, respectively.Conclusion: The proposed approach combined the advantages of several normalization preprocessing methods to improve the accuracy of all tissues in sCT images, which is promising for improving the accuracy of dose calculations based on CBCT images in adaptive radiotherapy.
- 24 April 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 24 (8) , e14004
Open AccessImproving synthetic CT accuracy by combining the benefits of multiple normalized preprocesses
Purpose: To investigate the effect of different normalization preprocesses in deep learning on the accuracy of different tissues in synthetic computed tomography (sCT) and to combine their advantages to improve the accuracy of all tissues.Methods: The cycle‐consistent adversarial network (CycleGAN) model was used to generate sCT images from megavolt cone‐beam CT (MVCBCT) images. In this study, 2639 head MVCBCT and CT image pairs from 203 patients were collected as a training set, and 249 image pairs from 29 patients were collected as a test set. We normalized the voxel values in images to 0 to 1 or −1 to 1, using two linear and five nonlinear normalization preprocessing methods to obtain seven data sets and compared the accuracy of different tissues in different sCT obtained from training these data. Finally, to combine the advantages of different normalization preprocessing methods, we obtained sCT_Blur by cropping, stitching, and smoothing (OpenCV's cv2.medianBlur, kernel size 5) each group of sCTs and evaluated its image quality and accuracy of OARs.Results: Different normalization preprocesses made sCT more accurate in different tissues. The proposed sCT_Blur took advantage of multiple normalization preprocessing methods, and all tissues are more accurate than the sCT obtained using a single conventional normalization method. Compared with other sCT images, the structural similarity of sCT_Blur versus CT was improved to 0.906 ± 0.019. The mean absolute errors of the CT numbers were reduced to 15.7 ± 4.1 HU, 23.2 ± 7.1 HU, 11.5 ± 4.1 HU, 212.8 ± 104.6 HU, 219.4 ± 35.1 HU, and 268.8 ± 88.8 HU for the oral cavity, parotid, spinal cord, cavity, mandible, and teeth, respectively.Conclusion: The proposed approach combined the advantages of several normalization preprocessing methods to improve the accuracy of all tissues in sCT images, which is promising for improving the accuracy of dose calculations based on CBCT images in adaptive radiotherapy.
- Open Access
- 1 January 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (1) , 169-178
Automatic synchrotron tomographic alignment schemes based on genetic algorithms and human-in-the-loop software
Tomography imaging methods at synchrotron light sources keep evolving, pushing multi-modal characterization capabilities at high spatial and temporal resolutions. To achieve this goal, small probe size and multi-dimensional scanning schemes are utilized more often in the beamlines, leading to rising complexities and challenges in the experimental setup process. To avoid spending a significant amount of human effort and beam time on aligning the X-ray probe, sample and detector for data acquisition, most attention has been drawn to realigning the systems at the data processing stages. However, post-processing cannot correct everything, and is not time efficient. Here we present automatic alignment schemes of the rotational axis and sample pre- and during the data acquisition process using a software approach which combines the advantages of genetic algorithms and human intelligence. Our approach shows excellent sub-pixel alignment efficiency for both tasks in a short time, and therefore holds great potential for application in the data acquisition systems of future scanning tomography experiments.
- 1 January 2023
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 30 (1) , 169-178
Open AccessAutomatic synchrotron tomographic alignment schemes based on genetic algorithms and human-in-the-loop software
Tomography imaging methods at synchrotron light sources keep evolving, pushing multi-modal characterization capabilities at high spatial and temporal resolutions. To achieve this goal, small probe size and multi-dimensional scanning schemes are utilized more often in the beamlines, leading to rising complexities and challenges in the experimental setup process. To avoid spending a significant amount of human effort and beam time on aligning the X-ray probe, sample and detector for data acquisition, most attention has been drawn to realigning the systems at the data processing stages. However, post-processing cannot correct everything, and is not time efficient. Here we present automatic alignment schemes of the rotational axis and sample pre- and during the data acquisition process using a software approach which combines the advantages of genetic algorithms and human intelligence. Our approach shows excellent sub-pixel alignment efficiency for both tasks in a short time, and therefore holds great potential for application in the data acquisition systems of future scanning tomography experiments.
- Open Access
- 10 November 2022
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 12, 1024160
A novel approach for eliminating metal artifacts based on MVCBCT and CycleGAN
Purpose: To develop a metal artifact reduction (MAR) algorithm and eliminate the adverse effects of metal artifacts on imaging diagnosis and radiotherapy dose calculations.Methods: Cycle-consistent adversarial network (CycleGAN) was used to generate synthetic CT (sCT) images from megavoltage cone beam CT (MVCBCT) images. In this study, there were 140 head cases with paired CT and MVCBCT images, from which 97 metal-free cases were used for training. Based on the trained model, metal-free sCT (sCT_MF) images and metal-containing sCT (sCT_M) images were generated from the MVCBCT images of 29 metal-free cases and 14 metal cases, respectively. Then, the sCT_MF and sCT_M images were quantitatively evaluated for imaging and dosimetry accuracy.Results: The structural similarity (SSIM) index of the sCT_MF and metal-free CT (CT_MF) images were 0.9484, and the peak signal-to-noise ratio (PSNR) was 31.4 dB. Compared with the CT images, the sCT_MF images had similar relative electron density (RED) and dose distribution, and their gamma pass rate (1 mm/1%) reached 97.99% ± 1.14%. The sCT_M images had high tissue resolution with no metal artifacts, and the RED distribution accuracy in the range of 1.003 to 1.056 was improved significantly. The RED and dose corrections were most significant for the planning target volume (PTV), mandible and oral cavity. The maximum correction of Dmean and D50 for the oral cavity reached 90 cGy.Conclusions: Accurate sCT_M images were generated from MVCBCT images based on CycleGAN, which eliminated the metal artifacts in clinical images completely and corrected the RED and dose distributions accurately for clinical application.
- 10 November 2022
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 12, 1024160
Open AccessA novel approach for eliminating metal artifacts based on MVCBCT and CycleGAN
Purpose: To develop a metal artifact reduction (MAR) algorithm and eliminate the adverse effects of metal artifacts on imaging diagnosis and radiotherapy dose calculations.Methods: Cycle-consistent adversarial network (CycleGAN) was used to generate synthetic CT (sCT) images from megavoltage cone beam CT (MVCBCT) images. In this study, there were 140 head cases with paired CT and MVCBCT images, from which 97 metal-free cases were used for training. Based on the trained model, metal-free sCT (sCT_MF) images and metal-containing sCT (sCT_M) images were generated from the MVCBCT images of 29 metal-free cases and 14 metal cases, respectively. Then, the sCT_MF and sCT_M images were quantitatively evaluated for imaging and dosimetry accuracy.Results: The structural similarity (SSIM) index of the sCT_MF and metal-free CT (CT_MF) images were 0.9484, and the peak signal-to-noise ratio (PSNR) was 31.4 dB. Compared with the CT images, the sCT_MF images had similar relative electron density (RED) and dose distribution, and their gamma pass rate (1 mm/1%) reached 97.99% ± 1.14%. The sCT_M images had high tissue resolution with no metal artifacts, and the RED distribution accuracy in the range of 1.003 to 1.056 was improved significantly. The RED and dose corrections were most significant for the planning target volume (PTV), mandible and oral cavity. The maximum correction of Dmean and D50 for the oral cavity reached 90 cGy.Conclusions: Accurate sCT_M images were generated from MVCBCT images based on CycleGAN, which eliminated the metal artifacts in clinical images completely and corrected the RED and dose distributions accurately for clinical application.
- 1 November 2022
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 17 (11) , P11005
Control infrastructure monitoring system at the NSRL facility cluster
The National Synchrotron Radiation Laboratory (NSRL) facility cluster is a collection of user facilities developed by NSRL, including the Hefei Light Source-II (HLS-II), Tunable Infrared Laser for Fundamental of Energy Chemistry (FELiChEM), and THz near-field high-flux material physical property test system (NFTHZ). User facilities generally have high operational availability requirements. The NSRL facility cluster relies on the control infrastructure to provide computing, network, and storage resources, as well as various services that must be available 24 hours a day, 7 days a week. The monitoring system is responsible for tracking the operational status of the control infrastructure, gathering information on faults, performance degradation and cybersecurity issues, and distributing alarm messages in time. It facilitates the operator troubleshooting problems efficiently to improve the availability of the user facilities. The monitoring system is developed by integrating several free and open source software tools. Zabbix is selected as the monitoring tool and collects metrics data from the control infrastructure. Three upper-layer applications are developed for data visualization. The dashboard shows the operational status of the network and various devices. The alarm system collects and distributes alarm messages via web-based GUI and WeChat. The reporting system periodically generates metrics and alarm reports. The monitoring system has been deployed since March 2022. The results indicate that the monitoring system can effectively identify hidden hazards in the control infrastructure.
- 1 November 2022
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 17 (11) , P11005
Control infrastructure monitoring system at the NSRL facility cluster
The National Synchrotron Radiation Laboratory (NSRL) facility cluster is a collection of user facilities developed by NSRL, including the Hefei Light Source-II (HLS-II), Tunable Infrared Laser for Fundamental of Energy Chemistry (FELiChEM), and THz near-field high-flux material physical property test system (NFTHZ). User facilities generally have high operational availability requirements. The NSRL facility cluster relies on the control infrastructure to provide computing, network, and storage resources, as well as various services that must be available 24 hours a day, 7 days a week. The monitoring system is responsible for tracking the operational status of the control infrastructure, gathering information on faults, performance degradation and cybersecurity issues, and distributing alarm messages in time. It facilitates the operator troubleshooting problems efficiently to improve the availability of the user facilities. The monitoring system is developed by integrating several free and open source software tools. Zabbix is selected as the monitoring tool and collects metrics data from the control infrastructure. Three upper-layer applications are developed for data visualization. The dashboard shows the operational status of the network and various devices. The alarm system collects and distributes alarm messages via web-based GUI and WeChat. The reporting system periodically generates metrics and alarm reports. The monitoring system has been deployed since March 2022. The results indicate that the monitoring system can effectively identify hidden hazards in the control infrastructure.
- Open Access
- 30 April 2022
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 33 (4) , 1
Correction to: Research on tune feedback of the Hefei Light Source II based on machine learning
- 30 April 2022
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 33 (4) , 1
Open AccessCorrection to: Research on tune feedback of the Hefei Light Source II based on machine learning
- Open Access
- 12 March 2022
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 33 (3) , 1-8
Research on tune feedback of the Hefei Light Source II based on machine learning
The theory of tune feedback correction and the principle of a feedback algorithm based on machine learning are introduced, with a focus on the application of lasso regression for tune feedback correction. Simulation verification and online feedback correction results are presented. The results show that, after applying machine learning, the feedback accuracy of the tune feedback system was higher, and the betatron tune stability was further improved.
- 12 March 2022
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 33 (3) , 1-8
Open AccessResearch on tune feedback of the Hefei Light Source II based on machine learning
The theory of tune feedback correction and the principle of a feedback algorithm based on machine learning are introduced, with a focus on the application of lasso regression for tune feedback correction. Simulation verification and online feedback correction results are presented. The results show that, after applying machine learning, the feedback accuracy of the tune feedback system was higher, and the betatron tune stability was further improved.
- 18 May 2021
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 32 (5) , 1-8
Activation and pumping characteristics of Ti–Zr–V films deposited on narrow tubes
- 18 May 2021
- Published by Springer Nature in Nuclear Science and Techniques
- Vol. 32 (5) , 1-8
Activation and pumping characteristics of Ti–Zr–V films deposited on narrow tubes