YPYuanji Pei

Yuanji Pei

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yuanji Pei has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Gongfa Liu

    National Synchrotron Radiation Laboratory University of Science and Technology of China Hefei China

    3 shared publications
  • Xiang Gao

    Hematology & Oncology Department Hefei First People's Hospital Hefei China

    2 shared publications
  • Yankui Chang

    School of Nuclear Science and Technology University of Science and Technology of China Hefei China

    2 shared publications
  • Zheng Cao

    National Synchrotron Radiation Laboratory University of Science and Technology of China Hefei China

    2 shared publications
  • Bin Qin

    State Key Laboratory of Advanced Electromagnetic Engineering and Technology Huazhong University of Science and Technology 430074 Wuhan China

    1 shared publication
  • Ji Li

    State Key Laboratory of Advanced Electromagnetic Engineering and Technology Huazhong University of Science and Technology 430074 Wuhan China

    1 shared publication

Latest Publications

  • Open Access

    Effect of metal implants and metal artifacts on back‐projected two‐dimensional entrance fluence determined by EPID dosimetry

    by Zheng Cao, Xiang Gao, Gongfa Liu, Yuanji Pei

    Purpose: To evaluate the errors caused by metal implants and metal artifacts in the two‐dimensional entrance fluences reconstructed using the back‐projection algorithm based on electronic portal imaging device (EPID) images.Methods: The EPID in the Varian VitalBeam accelerator was used to acquire portal dose images (PDIs), and then commercial EPID dosimetry software was employed to reconstruct the two‐dimensional entrance fluences based on computed tomography (CT) images of the head phantoms containing interchangeable metal‐free/titanium/aluminum round bars. The metal‐induced errors in the two‐dimensional entrance fluences were evaluated by comparing the γ results and the pixel value errors in the metal‐affected regions. We obtained metal‐artifact‐free CT images by replacing the voxel values of non‐metal inserts with those of metal inserts in metal‐free CT images to evaluate the metal‐artifact‐induced errors.Results: The γ passing rates (versus PDIs obtained without a phantom in the beam field (PDIair), 2%/2 mm) for the back‐projected two‐dimensional entrance fluences of phantoms containing titanium or aluminum (BPTi/BPAl) were reduced from 92.4% to 90.5% and 90.6%, respectively, relative to the metal‐free phantom (BPmetal‐free). Titanium causes more severe metal artifacts in CT images than aluminum, and its removal resulted in a 0.0022 CU (median) reduction in the pixel value of BPTi artifact‐free relative to BPTi in the metal‐affected region. Moreover, the mean absolute error (MAE) and root mean square error (RMSE) decreased from 0.0050 CU and 0.0063 CU to 0.0034 CU and 0.0040 CU, respectively (vs. BPmetal‐free).Conclusion: Metal implants increase the errors in back‐projected two‐dimensional entrance fluences, and metals with higher electron densities cause more errors. For high‐electron‐density metal implants that produce severe metal artifacts (e.g., titanium), removing metal artifacts from the CT images can improve the accuracy of the two‐dimensional entrance fluences reconstructed by back‐projection algorithms.


  • Open Access

    Improving synthetic CT accuracy by combining the benefits of multiple normalized preprocesses

    by Zheng Cao, Xiang Gao, Yankui Chang, Gongfa Liu, Yuanji Pei

    Purpose: To investigate the effect of different normalization preprocesses in deep learning on the accuracy of different tissues in synthetic computed tomography (sCT) and to combine their advantages to improve the accuracy of all tissues.Methods: The cycle‐consistent adversarial network (CycleGAN) model was used to generate sCT images from megavolt cone‐beam CT (MVCBCT) images. In this study, 2639 head MVCBCT and CT image pairs from 203 patients were collected as a training set, and 249 image pairs from 29 patients were collected as a test set. We normalized the voxel values in images to 0 to 1 or −1 to 1, using two linear and five nonlinear normalization preprocessing methods to obtain seven data sets and compared the accuracy of different tissues in different sCT obtained from training these data. Finally, to combine the advantages of different normalization preprocessing methods, we obtained sCT_Blur by cropping, stitching, and smoothing (OpenCV's cv2.medianBlur, kernel size 5) each group of sCTs and evaluated its image quality and accuracy of OARs.Results: Different normalization preprocesses made sCT more accurate in different tissues. The proposed sCT_Blur took advantage of multiple normalization preprocessing methods, and all tissues are more accurate than the sCT obtained using a single conventional normalization method. Compared with other sCT images, the structural similarity of sCT_Blur versus CT was improved to 0.906 ± 0.019. The mean absolute errors of the CT numbers were reduced to 15.7 ± 4.1 HU, 23.2 ± 7.1 HU, 11.5 ± 4.1 HU, 212.8 ± 104.6 HU, 219.4 ± 35.1 HU, and 268.8 ± 88.8 HU for the oral cavity, parotid, spinal cord, cavity, mandible, and teeth, respectively.Conclusion: The proposed approach combined the advantages of several normalization preprocessing methods to improve the accuracy of all tissues in sCT images, which is promising for improving the accuracy of dose calculations based on CBCT images in adaptive radiotherapy.


  • Open Access

    A novel approach for eliminating metal artifacts based on MVCBCT and CycleGAN

    by Zheng Cao, Xiang Gao, Yankui Chang, Gongfa Liu, Yuanji Pei

    Purpose: To develop a metal artifact reduction (MAR) algorithm and eliminate the adverse effects of metal artifacts on imaging diagnosis and radiotherapy dose calculations.Methods: Cycle-consistent adversarial network (CycleGAN) was used to generate synthetic CT (sCT) images from megavoltage cone beam CT (MVCBCT) images. In this study, there were 140 head cases with paired CT and MVCBCT images, from which 97 metal-free cases were used for training. Based on the trained model, metal-free sCT (sCT_MF) images and metal-containing sCT (sCT_M) images were generated from the MVCBCT images of 29 metal-free cases and 14 metal cases, respectively. Then, the sCT_MF and sCT_M images were quantitatively evaluated for imaging and dosimetry accuracy.Results: The structural similarity (SSIM) index of the sCT_MF and metal-free CT (CT_MF) images were 0.9484, and the peak signal-to-noise ratio (PSNR) was 31.4 dB. Compared with the CT images, the sCT_MF images had similar relative electron density (RED) and dose distribution, and their gamma pass rate (1 mm/1%) reached 97.99% ± 1.14%. The sCT_M images had high tissue resolution with no metal artifacts, and the RED distribution accuracy in the range of 1.003 to 1.056 was improved significantly. The RED and dose corrections were most significant for the planning target volume (PTV), mandible and oral cavity. The maximum correction of Dmean and D50 for the oral cavity reached 90 cGy.Conclusions: Accurate sCT_M images were generated from MVCBCT images based on CycleGAN, which eliminated the metal artifacts in clinical images completely and corrected the RED and dose distributions accurately for clinical application.


  • Open Access

    Research of L-band disk-loaded waveguides travelling wave accelerating structures for a high power Linac

    by Y M Zhang, Y J Pei, L S Sheng, Y F Song

    L-band Electron Accelerator has been widely utilized for industrial irradiation. In this paper, we designed a constant-impedance, disk-loaded structure which operates on 2π/3 mode. CST and SUPERFISH code were used for the design of bunching and accelerating cavities respectively. The geometrical parameters of the cavities were studied, and optimized RF parameters were obtained. We calculated the beam dynamics which presented that the electrons can be accelerated to 50 MeV. The model cavities have been fabricated and tested. Some valuable experimental results were obtained, which can provide a beneficial datum for the design and manufacture of L-band travelling-wave accelerating structures of 50 MeV LINAC.


  • Open Access

    Physical design of FEL injector based on performance-enhanced EC-ITC RF gun

    by Tong-Ning Hu, Qu-Shan Chen, Yuan-Ji Pei, Ji Li, Bin Qin

    To meet requirements of high performance THz-FEL (Free Electron Laser), a compact scheme of FEL injector was proposed. Thermionic cathode was chosen to emit electrons instead of photo-cathode with complex structure and high cost. The effective bunch charge was improved to ~200pC by adopting enhanced EC-ITC (External Cathode Independently Tunable Cells) RF gun to extract micro-bunches, and back bombardment effects were almost eliminated as well. Constant gradient accelerator structures were designed to improve energy to ~14MeV, while focusing system was applied for emittance suppressing and bunch state maintenance. Physical design and beam dynamics of key components for FEL injector were analyzed. Furthermore, start-to-end simulations with multi-pulses were performed by using homemade MATLAB and Parmela. The results show that continual high brightness electron bunches with low energy spread and emittance could be obtained stably.