TKTomio Koyama

Tomio Koyama

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tomio Koyama has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Orientation mapping of YbSn3 single crystals based on Bragg-dip analysis using a delay-line superconducting sensor

    by Hiroaki Shishido, The Dang Vu, Kazuya Aizawa, Kenji M. Kojima, Tomio Koyama, Kenichi Oikawa, Masahide Harada, Takayuki Oku, Kazuhiko Soyama, Shigeyuki Miyajima, et al.

    Recent progress in high-power pulsed neutron sources has stimulated the development of the Bragg-dip and Bragg-edge analysis methods using a two-dimensional neutron detector with high temporal resolution to resolve the neutron energy by the time-of-flight method. A delay-line current-biased kinetic inductance detector (CB-KID) is a two-dimensional superconducting sensor with a high temporal resolution and multi-hit capability. Here, it is demonstrated that a delay-line CB-KID with a 10B neutron conversion layer can be applied to high-spatial-resolution neutron transmission imaging and spectroscopy up to 100 eV. Dip structures are observed in the transmission spectra of YbSn3 single crystals, induced by Bragg diffraction and nuclear resonance absorption. The orientation mapping of YbSn3 crystals is successfully performed via the analysis of observed Bragg-dip positions in the transmission spectra.


  • High Spatial Resolution Neutron Transmission Imaging Using a Superconducting Two-Dimensional Detector

    by Hiroaki Shishido, Kazuma Nishimura, The Dang Vu, Kazuya Aizawa, Kenji M. Kojima, Tomio Koyama, Kenichi Oikawa, Masahide Harada, Takayuki Oku, Kazuhiko Soyama, et al.

    Neutron imaging is one of the most powerful tools for nondestructive inspection owing to the unique characteristics of neutron beams, such as high permeability for many heavy metals, high sensitivity for certain light elements, and isotope selectivity owing to a specific nuclear reaction between an isotope and neutrons. In this study, we employed a superconducting detector, current-biased kinetic-inductance detector (CB-KID) for neutron imaging using a pulsed neutron source. We employed the delay-line method, and high spatial resolution imaging with only four reading channels was achieved. We also performed wavelength-resolved neutron imaging by the time-of-flight method for the pulsed neutron source. We obtained the neutron transmission images of a Gd–Al alloy sample, inside which single crystals of GdAl $_3$ were grown, using the delay-line CB-KID. Single crystals were well imaged, in both shapes and distributions, throughout the Al–Gd alloy. We identified Gd nuclei via neutron transmissions that exhibited characteristic suppression above the neutron wavelength of 0.03 nm. In addition, the $^{155}$ Gd resonance dip, a dip structure of the transmission caused by the nuclear reaction between an isotope and neutrons, was observed even when the number of events was summed over a limited area of 15 $\mu$ m × 12 $\mu$ m. Gd selective imaging was performed using the resonance dip of $^{155}$ Gd, and it showed clear Gd distribution even with a limited neutron wavelength range of 1 pm.


  • Open Access

    Ginzburg-Landau theory for the operation principle of superconducting delay-line inductance detectors

    by T Koyama, T Ishida

    Transmission of voltage pulses generated by local heating in a kinetic inductance detector made of a superconducting stripline is theoretically investigated on the basis of the TDGL equation. The effect of thermal diffusion is also incorporated into the electrodynamics of this system. We derive an equation that can describe the generation and transmission of voltage pulses in this detector. A pair of voltage pulses with opposite polarities are created when a spatiotemporal variation in the superconducting order parameter occurs in a small region of this superconducting stripline. We clarify the characteristic feature in the shape of the voltage pulse.


  • Open Access

    Electrodynamic theory for the operation principle of a superconducting kinetic inductance stripline detector

    by T Koyama, T Ishida

    Generation and transmission of voltage signals in a kinetic inductance detector made of a superconducting nanowire stripline is investigated on the basis of superconducting electromagnetism. We show that electric signals traveling along the stripline in this detector can be regarded as a Swihart mode. An equation which can describe the generation and transmission of voltage pulses in this detector is derived. A pair of voltage pulses with opposite polarities are created when a spatiotemporal variation in the density of the superconducting condensate occurs in a small region of this superconducting nanowire. The voltage pulses propagate along the stripline in the directions opposite to each other with the Swihart velocity. The characteristic of the radiation detector named current-biased kinetic inductance detector (CB-KID) is well described by our model.