MSMarco Stijnen

Marco Stijnen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Marco Stijnen has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Normothermic Ex Vivo Liver Platform Using Porcine Slaughterhouse Livers for Disease Modeling

    by Melanie Krüger, Alicia Ruppelt, Benjamin Kappler, Elke Van Soest, Roos Anne Samsom, Guy C. M. Grinwis, Niels Geijsen, J. Bernd Helms, Marco Stijnen, Linda M. Kock, et al.

    Metabolic and toxic liver disorders, such as fatty liver disease (steatosis) and drug-induced liver injury, are highly prevalent and potentially life-threatening. To allow for the study of these disorders from the early stages onward, without using experimental animals, we collected porcine livers in a slaughterhouse and perfused these livers normothermically. With our simplified protocol, the perfused slaughterhouse livers remained viable and functional over five hours of perfusion, as shown by hemodynamics, bile production, indocyanine green clearance, ammonia metabolism, gene expression and histology. As a proof-of-concept to study liver disorders, we show that an infusion of free fatty acids and acetaminophen results in early biochemical signs of liver damage, including reduced functionality. In conclusion, the present platform offers an accessible system to perform research in a functional, relevant large animal model while avoiding using experimental animals. With further improvements to the model, prolonged exposure could make this model a versatile tool for studying liver diseases and potential treatments.


  • Open Access

    The Impact of Biomedical Engineering on the Development of Minimally Invasive Cardio-Thoracic Surgery

    by Riccardo Cocchieri, Bertus van de Wetering, Marco Stijnen, Robert Riezebos, Bastian de Mol

    (1) We describe the boundary conditions for minimally invasive cardiac surgery (MICS) with the aim to reduce procedure-related patient injury and discomfort. (2) The analysis of the MICS work process and its demand for improved tools and devices is followed by a description of the relevant sub-specialties of bio-medical engineering: electronics, biomechanics, and materials sciences. (3) Innovations can represent a desired adaptation of an existing work process or a radical redesign of procedure and devices such as in transcutaneous procedures. Focused interaction between engineers, industry, and surgeons is always mandatory (i.e., a therapeutic alliance for addressing ‘unmet patient or professional needs’. (4) Novel techniques in MICS lean heavily on usability and safe and effective use in dedicated hands. Therefore, the use of training and simulation models should enable skills selection, a safe learning curve, and maintenance of proficiency. (5) The critical technical steps and cost–benefit trade-offs during the journey from invention to application will be explained. Business considerations such as time-to-market and returns on investment do shape the cost–benefit room for commercial use of technology. Proof of clinical safety and effectiveness by physicians remains important, but establishing the technical reliability of MICS tools and warranting appropriate surgical skills come first.


  • Open Access

    First Expert Evaluation of a New Steerable Catheter in an Isolated Beating Heart

    by Awaz Ali, Tamas Szili-Torok, Marco Stijnen, Paul Breedveld, Dimitra Dodou

    Purpose: In previous studies we developed two mechanical prototypes of steerable catheters: theSigma, which uses joysticks to actuate two steerable tip segments, and theEpsilon, which has a handle that is an enlarged version of the tip. In this study, we present a first performance evaluation of the prototypes in the cardiac environment. The evaluation was carried out by an expert user, an electrophysiologist with over 20 years of experience, to obtain insight in clinically relevant factors.Methods: Two experiments were conducted. In the first experiment, theSigmawas used in a passive beating heart setup connected to pumps with a saline solution and camera visualization, and compared with the expert’s past experience with conventional steerable catheters. In the second experiment, theSigmawas used in an active beating heart setup with blood perfusion through the coronary arteries and echo visualization, and compared with theEpsilonprototype. The prototype was evaluated through questionnaires on task performance, catheter usability, and workload. After each of the experiments, the catheter characteristics were evaluatedviaa survey and followed by an in-depth interview.Results & Conclusions: The expert user found the passive beating heart setup to more successful than the active beating heart setup for the purpose of this experiment, with insightful visualization while the heart was in beating condition. The steerability of the prototypes was experienced as useful and clinically relevant. Based on the questionnaires and interview we were able to identify future design improvements and developments for the steerable catheter prototypes.


  • Prediction of Poststorage Cardiac Function From Cardioplegic Effluent in an Ex Vivo Porcine Heart Model

    by Benjamin Kappler, Sjoerd van Tuijl, Teus J. van Laar, Dara R. Pabittei, Marc P. Buijsrogge, Marco Stijnen, Bas A. J. M. de Mol

    The use of slaughterhouse-based hearts has advantages over hearts obtained from laboratory animals for preclinical testing. However, slaughterhouse hearts have greater variability in cardiac function; this has resulted in a dispute over their actual reproducibility. This study explores the feasibility of examining the cardioplegic effluent during hypothermic cardiac arrest for the presence of biomarkers to predict poststorage heart function of slaughterhouse hearts. This may enable proactive measures to optimize preservation strategies and improve the initial cardiac performance of slaughterhouse heart experiments. Slaughterhouse pig hearts (n = 9; 420 ± 30 g) were arrested and flushed with an additional liter cardioplegia after 1 h. Effluent samples were examined for ammonia, lactate, troponin, and inorganic phosphate. After 2 h, hearts were hemoreperfused in the ex vivo heart platform PhysioHeart™ to restore physiological cardiac functions and to identify correlations between biomarkers and cardiac output. There was a negative correlation between cardiac output of revived hearts and levels of ammonia (r = −0.865; p = 0.002) and lactate (r = −0.763; p = 0.01). No correlation was found between cardiac output and levels of phosphate (r = −0.553; p = 0.12) and troponin (r = −0.367; p = 0.331). The analysis approach to assess cardioplegic biomarkers was feasible and enabled the estimation of the effectiveness of organ protection and cardiac function before reperfusion. Ammonia is a predictor for cardiac dysfunction. Effluent analysis prior to heart revival can uncover poststorage cardiac dysfunction in isolated hearts and may prevent failed experiments while improving reproducibility and standardization.


  • An Innovative Ex Vivo Vascular Bioreactor as Comprehensive Tool to Study the Behavior of Native Blood Vessels Under Physiologically Relevant Conditions

    by Noemi Vanerio, Marco Stijnen, Bas A. J. M. de Mol, Linda M. Kock

    Ex vivo systems represent important models to study vascular biology and to test medical devices, combining the advantages of in vitro and in vivo models such as controllability of parameters and the presence of biological response, respectively. The aim of this study was to develop a comprehensive ex vivo vascular bioreactor to long-term culture and study the behavior of native blood vessels under physiologically relevant conditions. The system was designed to allow for physiological mechanical loading in terms of pulsatile hemodynamics, shear stress, and longitudinal prestretch and ultrasound imaging for vessel diameter and morphology evaluation. In this first experience, porcine carotid arteries (n = 4) from slaughterhouse animals were cultured in the platform for 10 days at physiological temperature, CO2 and humidity using medium with blood-mimicking viscosity, components, and stability of composition. As expected, a significant increase in vessel diameter was observed during culture. Flow rate was adjusted according to diameter values to reproduce and maintain physiological shear stress, while pressure was kept physiological. Ultrasound imaging showed that the morphology and structure of cultured arteries were comparable to in vivo. Histological analyses showed preserved endothelium and extracellular matrix and neointimal tissue growth over 10 days of culture. In conclusion, we have developed a comprehensive pulsatile system in which a native blood vessel can be cultured under physiological conditions. The present model represents a significant step toward ex vivo testing of vascular therapies, devices, drug interaction, and as basis for further model developments.


  • Intermodel disagreement of myocardial blood flow estimation from dynamic CT perfusion imaging

    by Marly van Assen, Gert Jan Pelgrim, Carlo N. De Cecco, J. Marco A. Stijnen, Beatrice M. Zaki, Matthijs Oudkerk, Rozemarijn Vliegenthart, U. Joseph Schoepf


  • Bridging Organ- and Cellular-Level Behavior in Ex Vivo Experimental Platforms Using Populations of Models of Cardiac Electrophysiology

    by Carlos A. Ledezma, Benjamin Kappler, Veronique Meijborg, Bas Boukens, Marco Stijnen, P. J. Tan, Vanessa Díaz-Zuccarini

    The inability to discern between pathology and physiological variability is a key issue in cardiac electrophysiology since this prevents the use of minimally invasive acquisitions to predict early pathological behavior. The goal of this work is to demonstrate how experimentally calibrated populations of models (ePoM) may be employed to inform which cellular-level pathologies are responsible for abnormalities observed in organ-level acquisitions while accounting for intersubject variability; this will be done through an exemplary computational and experimental approach. Unipolar epicardial electrograms (EGM) were acquired during an ex vivo porcine heart experiment. A population of the Ten Tusscher 2006 model was calibrated to activation–recovery intervals (ARI), measured from the electrograms, at three representative times. The distributions of the parameters from the resulting calibrated populations were compared to reveal statistically significant pathological variations. Activation–recovery interval reduction was observed in the experiments, and the comparison of the calibrated populations of models suggested a reduced L-type calcium conductance and a high extra-cellular potassium concentration as the most probable causes for the abnormal electrograms. This behavior was consistent with a reduction in the cardiac output (CO) and was confirmed by other experimental measurements. A proof of concept method to infer cellular pathologies by means of organ-level acquisitions is presented, allowing for an earlier detection of pathology than would be possible with current methods. This novel method that uses mathematical models as a tool for formulating hypotheses regarding the cellular causes of observed organ-level behaviors, while accounting for physiological variability has been unexplored.


  • Evaluating the Risks of Arrhythmia through Big Data: Automatic Processing and Neural Networks to Classify Epicardial Electrograms

    by Carlos Ledezma, Benjamin Kappler, Veronique Meijborg, Bas Boukens, Marco Stijnen, Pj Tan, Vanessa Diaz-Zuccarini


  • A Big Data Approach to Myocyte Membrane Analysis: Using Populations of Models to Understand the Cellular Causes of Heart Failure

    by Carlos Ledezma, Benjamin Kappler, Veronique Meijborg, Bas Boukens, Marco Stijnen, Pj Tan, Vanessa Diaz-Zuccarini


  • Using Populations of Models to Navigate Big Data in Electrophysiology: Evaluation of Parameter Sensitivity of Action Potential Models

    by Carlos Ledezma, Benjamin Kappler, Veronique Meijborg, Bas Boukens, Marco Stijnen, Pj Tan, Vanessa Diaz-Zuccarini