Kelsi M. Katcher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kelsi M. Katcher has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Abhay Patil
Southwest Research Institute, 6220 Culebra Rd, San Antonio, Texas, USA
2 shared publications Dereje Amogne
Vacuum Process Engineering, 110 Commerce Cir, Sacramento, California, USA
2 shared publications- Brandon Ridens
Southwest Research Institute, San Antonio, TX 78238
1 shared publication - Klaus Brun
Southwest Research Institute, San Antonio, TX 78238
1 shared publication - Rainer Kurz
Solar Turbines Incorporated, San Diego, CA 92123
1 shared publication - Ryan Cater
Southwest Research Institute, San Antonio, TX 78238
1 shared publication
Latest Publications
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2815 (1)
Defining a compact dry cooler design to reduce LCOE contribution in a CSP facility
Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO2) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO2-side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2815 (1)
Open AccessDefining a compact dry cooler design to reduce LCOE contribution in a CSP facility
Concentrating solar power (CSP), when coupled with a supercritical carbon dioxide (sCO2) power cycle and sensible heat storage, presents a renewable and clean alternative for utility-scale power generation. However, in order to be competitive in the current and future markets, CSP facilities must limit their levelized cost of electricity (LCOE) by minimizing capital costs and reducing operating costs over the lifetime of the plant. Targeting this goal, this study investigates the LCOE impact of the power cycle pre-cooler. This study considers a compact dry cooler with micro-channel technology on the CO2 side and formed fin geometry on the air side, using directly-coupled centrifugal fans and a transition duct to improve air distribution across the fins as well as protect the fins from contaminants which may cause blockage, soiling, fouling, and damage. In an effort to better understand the dry cooler impact on LCOE, a sensitivity study was conducted using various combinations of end-to-end approach temperatures, air-side pressure drop values, CO2-side pressure drop values, fan types, cooler turndown control schemes, cooler module sizes, and design-point ambient temperatures. Off-design cycle performance data was calculated for each dry cooler design using NPSS simulation software; cycle performance data were then input to System Advisor Model (SAM) along with the associated capital costs for LCOE prediction of a 100 MW system over a 30 year plant lifetime. Results of this study show the LCOE is most sensitive to air-side performance, followed by heat transfer effectiveness and capital cost. It was found that a power cycle with a mid- to high-performance dry cooler will produce the most competitive power-production costs. Designing at the extreme ends for approach temperature (or effectiveness), design-point ambient temperature, and compactness (footprint) produce higher LCOE values; mid-range values for these parameters balance performance, operating costs, and associated capital cost to optimize LCOE.
- 21 October 2022
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 145 (1)
Design of a Compact Dry Cooler With an Aluminum Heat Exchanger Core for a Supercritical CO2 Power Cycle Is Evaluated for a Concentrating Solar Power Application
As the supercritical CO2 power cycle develops and the component technologies mature, there is still a need to reduce the associated capital and operating costs to maintain a competitive levelized cost of electricity (LCOE) in order to enter the market. When considering concentrating solar power (CSP) coupled with an sCO2 power block and sensible thermal storage, the technology presents a clean source for utility-scale power generation to support baseload or peak-load electrical demand. However, the LCOE of the technology is still considered higher than the competing technologies and should be reduced to better compete in the market; 2030 targets for dispatchable solar plants are 5¢/kWh for baseload CSP and 10¢/kWh for peaker plants, as set by the United States Department of Energy. In response to this need, this study is targeting improvements in the power cycle precooler to reduce power block contribution to LCOE. This study considers a dry cooler, as CSP plants are sensitive to water consumption because many installations are slated for remote or arid locations where solar irradiance is very high, but water is scarce. Furthermore, the power block footprint for an sCO2 system is quite compact, especially as compared to a steam cycle. Therefore, there is interest in installing a more compact dry cooler that is proportional to the reduced footprint sCO2 power block, while conventional dry coolers are an order of magnitude larger. The competing goals of size, performance, and cost were considered in this study to develop a compact dry cooler that can easily be packaged with the power block, significantly reducing the installation and transport cost compared to the current state of the art, while maintaining or improving upon the heat transfer performance and impact on plant LCOE. This paper details the high-level findings of a large dry cooler sensitivity study for design point selection, design of the compact dry cooler, expected year-round performance for the dry cooler and the power cycle, and the predicted LCOE for a 30-year plant life. It was found that an aluminum heat exchanger core can be suitably designed to meet the pressure and temperature requirements for a precooler in an sCO2 recompression Brayton cycle. The dry cooler assembly was found to have improved heat transfer performance, allowing for increased cycle efficiencies and a reduced plant LCOE. When coupled with a centrifugal blower and compact transition duct, the dry cooler assembly was able to reduce the installation footprint by over 50%.
- 21 October 2022
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 145 (1)
Design of a Compact Dry Cooler With an Aluminum Heat Exchanger Core for a Supercritical CO2 Power Cycle Is Evaluated for a Concentrating Solar Power Application
As the supercritical CO2 power cycle develops and the component technologies mature, there is still a need to reduce the associated capital and operating costs to maintain a competitive levelized cost of electricity (LCOE) in order to enter the market. When considering concentrating solar power (CSP) coupled with an sCO2 power block and sensible thermal storage, the technology presents a clean source for utility-scale power generation to support baseload or peak-load electrical demand. However, the LCOE of the technology is still considered higher than the competing technologies and should be reduced to better compete in the market; 2030 targets for dispatchable solar plants are 5¢/kWh for baseload CSP and 10¢/kWh for peaker plants, as set by the United States Department of Energy. In response to this need, this study is targeting improvements in the power cycle precooler to reduce power block contribution to LCOE. This study considers a dry cooler, as CSP plants are sensitive to water consumption because many installations are slated for remote or arid locations where solar irradiance is very high, but water is scarce. Furthermore, the power block footprint for an sCO2 system is quite compact, especially as compared to a steam cycle. Therefore, there is interest in installing a more compact dry cooler that is proportional to the reduced footprint sCO2 power block, while conventional dry coolers are an order of magnitude larger. The competing goals of size, performance, and cost were considered in this study to develop a compact dry cooler that can easily be packaged with the power block, significantly reducing the installation and transport cost compared to the current state of the art, while maintaining or improving upon the heat transfer performance and impact on plant LCOE. This paper details the high-level findings of a large dry cooler sensitivity study for design point selection, design of the compact dry cooler, expected year-round performance for the dry cooler and the power cycle, and the predicted LCOE for a 30-year plant life. It was found that an aluminum heat exchanger core can be suitably designed to meet the pressure and temperature requirements for a precooler in an sCO2 recompression Brayton cycle. The dry cooler assembly was found to have improved heat transfer performance, allowing for increased cycle efficiencies and a reduced plant LCOE. When coupled with a centrifugal blower and compact transition duct, the dry cooler assembly was able to reduce the installation footprint by over 50%.
- 1 October 2018
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 141 (2)
A Method and Apparatus for Direct Enthalpy Rise Measurement for Gas Compression
Gas property prediction is necessary for proper design of compressors. Equations of state are utilized to predict the thermo-physical gas properties needed for such calculations. These are semi-empirical models that allow the calculation of thermodynamic properties such as density, enthalpy, and speed of sound of gas mixtures for known pressures and temperature. Currently, there is limited or no data publically available to verify the results of these equation of state calculations for the range of pressures, temperatures, and gas compositions relevant to many oil and gas applications. Especially for isentropic enthalpy head (i.e., the enthalpy rise along constant entropy lines), which is a critical parameter required to accurately design and performance test compressors, limited public domain data are available for equation of state validation. In this paper, a method and test apparatus is described to measure compression enthalpy rise directly. In this apparatus, a test gas is compressed using a fast acting piston inside an adiabatic autoclave. Test results are then corrected using calibration efficiencies from a known reference gas compression process at a similar Reynolds number. The paper describes the test apparatus, calibration, measurement methodology, and test results for one complex hydrocarbon gas composition at elevated temperatures and pressures. An uncertainty analysis of the new measurement method is also presented and results are compared to several equations of state. The results show that commonly used equations of state significantly underpredicted the compression enthalpy rise for the test gas case by more than 6%.
- 1 October 2018
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 141 (2)
A Method and Apparatus for Direct Enthalpy Rise Measurement for Gas Compression
Gas property prediction is necessary for proper design of compressors. Equations of state are utilized to predict the thermo-physical gas properties needed for such calculations. These are semi-empirical models that allow the calculation of thermodynamic properties such as density, enthalpy, and speed of sound of gas mixtures for known pressures and temperature. Currently, there is limited or no data publically available to verify the results of these equation of state calculations for the range of pressures, temperatures, and gas compositions relevant to many oil and gas applications. Especially for isentropic enthalpy head (i.e., the enthalpy rise along constant entropy lines), which is a critical parameter required to accurately design and performance test compressors, limited public domain data are available for equation of state validation. In this paper, a method and test apparatus is described to measure compression enthalpy rise directly. In this apparatus, a test gas is compressed using a fast acting piston inside an adiabatic autoclave. Test results are then corrected using calibration efficiencies from a known reference gas compression process at a similar Reynolds number. The paper describes the test apparatus, calibration, measurement methodology, and test results for one complex hydrocarbon gas composition at elevated temperatures and pressures. An uncertainty analysis of the new measurement method is also presented and results are compared to several equations of state. The results show that commonly used equations of state significantly underpredicted the compression enthalpy rise for the test gas case by more than 6%.