MDMehul A. Dharia

Mehul A. Dharia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mehul A. Dharia has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Use of Real-World Data for Enhancing Model Credibility: Applications to Medical Device Development

    by Paul Briant, Jeffrey E. Bischoff, Mehul A. Dharia, Franck Le Navéaux, XueMei Li, Sanjeev Kulkarni, Danny Levine, David O. Ramos, Payman Afshari

    Evaluating the credibility of computational models used in medical device development is increasingly important as medical devices become more complex and modeling takes on a more critical role in the device development process. While bench-testing based comparisons are common for assessing model credibility and have many advantages, such as control over test specimens and the ability to quantify outputs, the credibility assessments performed with bench tests often do not evaluate the clinical relevance of key aspects of model form (such as boundary conditions, constitutive models/properties, and geometries) selected when simulating in vivo conditions. Real-world data (outcomes data generated through clinical use of a device) offer an opportunity to assess the applicability and clinical relevance of a computational model. Although real-world data are frequently less controlled and more qualitative than benchtop data, real-world data are often a direct assessment of a particular clinical complication and therefore of high clinical relevance. Further, real-world data have the potential to reveal failure modes not previously identified in preclinical failure modes analysis, thereby motivating testing advancements. To review the use of clinical data in medical device modeling, this paper presents a series of examples related to tibial tray fracture that incorporate varying levels of benchtop data and real world data when evaluating model credibility. The merits and drawbacks of the credibility assessment for each example are discussed in order to provide practical and actionable guidance on the use of real-world data for establishing and demonstrating model credibility.


  • Open Access

    02-01 Development and Application of Verification and Validation Standards Sessions

    by Luis Eca, Mehul Dharia, Mark Goodin, William Oberkampf, Alexander Karl

  • Open Access

    02-01 Development and Application of Verification and Validation Standards Sessions

    by Luis Eca, Mehul Dharia, Mark Goodin, William Oberkampf, Alexander Karl

  • Computational Model Validation of Contact Mechanics in Total Ankle Arthroplasty

    by Mehul A. Dharia, Sandra Snyder, Jeffrey E. Bischoff

    Revision rates in total ankle arthroplasty (TAA) are nearly double compared with hip or knee arthroplasty procedures. Contact mechanics for metal–polyethylene articulation in TAA is critical due to the reduced size of the implant and higher expected load, compared with a hip or knee joint. This study was focused on developing a validated computational model to predict contact area in a polyethylene tibial bearing articulating with a metallic talar component in a bicondylar TAA design. Contact area was evaluated at five different flexion angles in an experimental test and in a computational model, per ASTM F2665. The overall contact area values predicted in the computational model matched closely (within 8%) with that measured in the comparator; well within the range reported in the literature. The credibility of the model to sufficiently predict the outputs relative to the experimental data was discussed using the guidelines provided by the recently published ASME V&V 40‐2018 standard. Various sensitivities associated with both the model and the comparator, were explored. It was concluded that the validated modeling approach presented in this study demonstrated sufficient accuracy to support the use of modeling for evaluation of contact area of TAA designs. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 38:1063‐1069, 2020


  • 0921 - The Influence of Constrained Condylar TKA Tibial Spine Design on Anterior Impingement Forces

    by Mehul Dharia, Danny Levine, Jeffrey Bischoff

    INTRODUCTION: Constrained condylar knee (CCK) prostheses have been designed to compensate for ligament instability in revision TKA. The strength |

  • Open Access

    Impact of Modeling Assumptions on Stability Predictions in Reverse Total Shoulder Arthroplasty

    by Mehul A. Dharia, Jeffrey E. Bischoff, David Schneider

    Reverse total shoulder arthroplasty (rTSA) is commonly used in the shoulder replacement surgeries for the relief of pain and to restore function, in patients with grossly deficient rotator cuff. Primary instability due to glenoid loosening is one of the critical complications of rTSA; the implants are designed and implanted such that the motion between the glenoid baseplate and underlying bone is minimized to facilitate adequate primary fixation. Finite element analysis (FEA) is commonly used to simulate the test setup per ASTM F2028-14 for comparing micromotion between designs or configurations to study the pre-clinical indications for stability. The FEA results can be influenced by the underlying modeling assumptions. It is a common practice to simplify the screw shafts by modeling them as cylinders and modeling the screw-bone interface using bonded contact, to evaluate micromotion in rTSA components. The goal of this study was to evaluate the effect of three different assumptions for modeling the screw-bone interface on micromotion predictions. The credibility of these modeling assumptions was examined by comparing the micromotion rank order predicted among three different modular configurations with similar information from the literature. Eight configurations were modeled using different number of screws, glenosphere offset, and baseplate sizes. An axial compression and shear load was applied through the glenosphere and micromotion at the baseplate-bone interface was measured. Three modeling assumptions pertaining to modeling of the screw-bone interface were used and micromotion results were compared to study the effect of number of peripheral screws, eccentricities, and baseplate diameter. The relative comparison of micromotion between configurations using two versus four peripheral screws remained unchanged irrespective of the three modeling assumptions. However, the relative comparison between two inferior offsets and baseplate sizes changed depending on the modeling assumptions used for the screw-bone interface. The finding from this study challenges the generally believed hypothesis that FEA models can be used to make relative comparison of micromotion in rTSA designs as long as the same modeling assumptions are used across all models. The comparisons with previously published work matched the finding from this study in some cases, whereas the comparison was contradicting in other cases. It is essential to validate the computer modeling approach with an experiment using similar designs and methods to increase the confidence in the predictions to make design decisions.