Mark Goodin
Research Subjects
Mark Goodin has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Karl
Rolls-Royce Corporation , Indianapolis, IN 46225
2 shared publications - Luís Eça
Instituto Superior Técnico
2 shared publications - Mehul A. Dharia
Zimmer Biomet , 1800 West Center Street, Warsaw, IN 46580
2 shared publications - William L. Oberkampf
Mem. ASME W. L. Oberkampf Consulting, 5112 Hidden Springs Trail, Georgetown, TX 78633
2 shared publications M. Ertan Taskin
SimuTech Group
1 shared publication
Latest Publications
- Open Access
- 22 July 2026
- Published by Springer Nature
- p. 473-498
Establishing the Credibility of Computational Models of Blood Pumps Through Verification, Validation, and Uncertainty Quantification
The ability to artificially pump blood is of great clinical importance and has positively impacted the lives of patients for many years. Beginning with rotary, peristaltic pumps dating from the mid 1800s, the technologies used for pumping blood have evolved to address patient needs in areas such as hemodialysis, transfusion, laboratory testing, and circulatory support. These applications share common challenges in providing the desired blood flow rate for a given driving pressure while minimizing damage to the cellular components within blood. For several decades, computational fluid dynamics (CFD) modeling has played an increasingly larger role in advancing blood pump technology, from guiding early-stage design efforts through supporting regulatory submissions. Combined with in vitro and in vivo testing, CFD modeling can provide critical insights needed to create safer and longer lasting blood pumps. This chapter begins by reviewing the history of extracorporeal support along with key performance parameters and typical computational modeling methods used for simulating blood pumps. With this foundation in place, the focus turns to reviewing two case studies that apply the American Society of Mechanical Engineers (ASME) V&V40 risk-based framework to implantable ventricular assist devices intended for long-term patient support. Several additional questions of interest related to blood pumps are also proposed. A table summarizing different blood pump-related performance parameters, ranked by computational complexity, along with their clinical significance and associated validation methods, is also provided to demonstrate the broad use of CFD modeling in circulatory support system development. The chapter concludes with a discussion about future CFD modeling efforts that could further advance blood pump technology.
- 22 July 2026
- Published by Springer Nature
- p. 473-498
Open AccessEstablishing the Credibility of Computational Models of Blood Pumps Through Verification, Validation, and Uncertainty Quantification
The ability to artificially pump blood is of great clinical importance and has positively impacted the lives of patients for many years. Beginning with rotary, peristaltic pumps dating from the mid 1800s, the technologies used for pumping blood have evolved to address patient needs in areas such as hemodialysis, transfusion, laboratory testing, and circulatory support. These applications share common challenges in providing the desired blood flow rate for a given driving pressure while minimizing damage to the cellular components within blood. For several decades, computational fluid dynamics (CFD) modeling has played an increasingly larger role in advancing blood pump technology, from guiding early-stage design efforts through supporting regulatory submissions. Combined with in vitro and in vivo testing, CFD modeling can provide critical insights needed to create safer and longer lasting blood pumps. This chapter begins by reviewing the history of extracorporeal support along with key performance parameters and typical computational modeling methods used for simulating blood pumps. With this foundation in place, the focus turns to reviewing two case studies that apply the American Society of Mechanical Engineers (ASME) V&V40 risk-based framework to implantable ventricular assist devices intended for long-term patient support. Several additional questions of interest related to blood pumps are also proposed. A table summarizing different blood pump-related performance parameters, ranked by computational complexity, along with their clinical significance and associated validation methods, is also provided to demonstrate the broad use of CFD modeling in circulatory support system development. The chapter concludes with a discussion about future CFD modeling efforts that could further advance blood pump technology.
- Open Access
- 27 July 2021
- Published by ASME International
02-01 Development and Application of Verification and Validation Standards Sessions
- 27 July 2021
- Published by ASME International
Open Access02-01 Development and Application of Verification and Validation Standards Sessions
- Open Access
- 27 July 2021
- Published by ASME International
02-01 Development and Application of Verification and Validation Standards Sessions
- 27 July 2021
- Published by ASME International
Open Access02-01 Development and Application of Verification and Validation Standards Sessions