Dairoku Muramatsu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dairoku Muramatsu has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Miyu Kodama
The University of Electro-Communications, Chofu, Tokyo, Japan
5 shared publications - Ken Sasaki
Department of Human and Engineered Environmental Studies, Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8563, Japan
4 shared publications Fukuro Koshiji
3 shared publicationsKen Sasaki
Univ Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 2778563, Japan
3 shared publications- Ken Sasaki
Department of Hematology and Oncology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
2 shared publications Kenichi Higuchi
Tokyo University of Science 2641 Yamazaki, Noda Chiba 278‐8510 Japan
2 shared publications
Latest Publications
- 10 October 2026
- Published by Springer Nature
- p. 134-142
A Fundamental Study of Inductive/Capacitive Hybrid WPT for Implantable Devices: Coupler Misalignment Tolerance
- 10 October 2026
- Published by Springer Nature
- p. 134-142
A Fundamental Study of Inductive/Capacitive Hybrid WPT for Implantable Devices: Coupler Misalignment Tolerance
- Open Access
- 21 April 2026
- Published by Springer Nature in Journal on Wireless Communications and Networking
- Vol. 2026 (1)
Wearable antenna supporting dual physical layers for IEEE 802.15.6 WBAN
Integrated wearable healthcare systems enable the continuous monitoring and collection of physiological data. In these systems, wearable devices and sensors are interconnected through on-body communication, with some devices used for off-body communication. The antennas employed for such devices must be small without compromising the resulting performance. In this study, we propose a dual-mode antenna that supports two physical layers: human body communication (HBC, 21 MHz band) and narrowband wireless communication (NBWC, 2.4 GHz band). To reduce the size of the developed antenna, the HBC electrodes are integrated into the ground plane of a conventional patch antenna, and a single feed point is shared. We evaluate the antenna through numerical electromagnetic field simulations conducted using a multilayer arm phantom. The results show that the antenna maintains a reflection coefficient below − 10 dB across the NBWC band, ensuring reliable off-body links, and yields a simulated reflection coefficient of − 4 dB in the HBC band. A radiation pattern analysis performed at 2.4 GHz reveals a nearly omnidirectional profile in free space and an efficiency level within the acceptable 20–40% range when the system is worn. In the HBC mode, the arm phantom increases the coupling effect by more than 50 dB. The specific absorption rate values remain below international safety limits, confirming the biocompatibility of the antenna.
- 21 April 2026
- Published by Springer Nature in Journal on Wireless Communications and Networking
- Vol. 2026 (1)
Open AccessWearable antenna supporting dual physical layers for IEEE 802.15.6 WBAN
Integrated wearable healthcare systems enable the continuous monitoring and collection of physiological data. In these systems, wearable devices and sensors are interconnected through on-body communication, with some devices used for off-body communication. The antennas employed for such devices must be small without compromising the resulting performance. In this study, we propose a dual-mode antenna that supports two physical layers: human body communication (HBC, 21 MHz band) and narrowband wireless communication (NBWC, 2.4 GHz band). To reduce the size of the developed antenna, the HBC electrodes are integrated into the ground plane of a conventional patch antenna, and a single feed point is shared. We evaluate the antenna through numerical electromagnetic field simulations conducted using a multilayer arm phantom. The results show that the antenna maintains a reflection coefficient below − 10 dB across the NBWC band, ensuring reliable off-body links, and yields a simulated reflection coefficient of − 4 dB in the HBC band. A radiation pattern analysis performed at 2.4 GHz reveals a nearly omnidirectional profile in free space and an efficiency level within the acceptable 20–40% range when the system is worn. In the HBC mode, the arm phantom increases the coupling effect by more than 50 dB. The specific absorption rate values remain below international safety limits, confirming the biocompatibility of the antenna.
- Open Access
- 1 February 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (2)
Multiuser human body communication via inter-user contact: Evaluation of signal propagation with electromagnetic simulations and wearable measurements
Multiuser human body communication (MU-HBC) uses multiple human bodies as a part of the transmission channel and enables intuitive data sharing among users through physical contact. This paper investigates signal propagation in MU-HBC by combining electromagnetic field simulations with measurements using wearable transceivers. In the simulations, a transmitter was attached to the left wrist of a male whole-body model, and two receivers were placed on the left and right wrists of a female model. Electric field distributions and transmission characteristics at 10 MHz were calculated using the finite-difference time-domain method for three inter-user contact conditions: no contact, hand-holding, and arm-linking. In the measurements, two human subjects wore compact, battery-powered spectrum analyzers connected to electrodes on their wrists, and the transmission characteristics were measured for hand-holding and arm-linking. The simulated and measured results consistently showed that the receiver position relative to the transmitter is the dominant factor determining the transmission characteristics, whereas the difference between hand-holding and arm-linking is comparatively small. In particular, the receiver closer to the transmitter exhibited a path loss of 7–15 dB smaller than that of the farther receiver. The measured values agreed with the simulations within 1 dB for the closer receiver and within several decibels for the farther receiver, and the standard deviation over five repeated measurements was at most 2.65 dB. These findings demonstrate that reliable signal propagation through multiple human bodies can be achieved via direct contact and provide design guidelines for wearable transceivers and low-power front-end circuits in MU-HBC systems.
- 1 February 2026
- Published by AIP Publishing in AIP Advances
- Vol. 16 (2)
Open AccessMultiuser human body communication via inter-user contact: Evaluation of signal propagation with electromagnetic simulations and wearable measurements
Multiuser human body communication (MU-HBC) uses multiple human bodies as a part of the transmission channel and enables intuitive data sharing among users through physical contact. This paper investigates signal propagation in MU-HBC by combining electromagnetic field simulations with measurements using wearable transceivers. In the simulations, a transmitter was attached to the left wrist of a male whole-body model, and two receivers were placed on the left and right wrists of a female model. Electric field distributions and transmission characteristics at 10 MHz were calculated using the finite-difference time-domain method for three inter-user contact conditions: no contact, hand-holding, and arm-linking. In the measurements, two human subjects wore compact, battery-powered spectrum analyzers connected to electrodes on their wrists, and the transmission characteristics were measured for hand-holding and arm-linking. The simulated and measured results consistently showed that the receiver position relative to the transmitter is the dominant factor determining the transmission characteristics, whereas the difference between hand-holding and arm-linking is comparatively small. In particular, the receiver closer to the transmitter exhibited a path loss of 7–15 dB smaller than that of the farther receiver. The measured values agreed with the simulations within 1 dB for the closer receiver and within several decibels for the farther receiver, and the standard deviation over five repeated measurements was at most 2.65 dB. These findings demonstrate that reliable signal propagation through multiple human bodies can be achieved via direct contact and provide design guidelines for wearable transceivers and low-power front-end circuits in MU-HBC systems.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 102920-102928
Conductive-Embroidered Logo Antenna for Wearable Passive UHF RFID Tags
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 102920-102928
Open AccessConductive-Embroidered Logo Antenna for Wearable Passive UHF RFID Tags
- Open Access
Ambient Electromagnetic Wave Energy Harvesting Using Human Body Antenna for Wearable Sensors
Wearable sensors are central to health-monitoring systems, but the limited capacity of compact batteries poses a challenge for long-term and maintenance-free operation. In this study, we investigated ambient electromagnetic wave (AEMW) energy harvesting using a human body antenna (HBA) as a means to supply power to wearable sensors. The power density and frequency distribution of AEMWs were measured in diverse indoor, outdoor, and basement environments. We designed and fabricated a flexible HBA–circuit interface electrode, optimized for broadband impedance matching when worn on the body. Experimental comparisons using a simulated AEMW source demonstrated that the HBA outperformed a conventional small whip antenna, particularly at frequencies below 300 MHz. Furthermore, the outdoor measurements indicated that the power harvested by the HBA was estimated to be −31.9 dBm (0.64 μW), which is sufficient for the intermittent operation of low-power wearable sensors and Bluetooth Low Energy modules. The electromagnetic safety was also evaluated through numerical analysis, and the specific absorption rate was confirmed to be well below the international safety limits. These findings indicate that HBA-based AEMW energy harvesting provides a practical and promising approach to achieving battery-maintenance-free wearable devices.
Open AccessAmbient Electromagnetic Wave Energy Harvesting Using Human Body Antenna for Wearable Sensors
Wearable sensors are central to health-monitoring systems, but the limited capacity of compact batteries poses a challenge for long-term and maintenance-free operation. In this study, we investigated ambient electromagnetic wave (AEMW) energy harvesting using a human body antenna (HBA) as a means to supply power to wearable sensors. The power density and frequency distribution of AEMWs were measured in diverse indoor, outdoor, and basement environments. We designed and fabricated a flexible HBA–circuit interface electrode, optimized for broadband impedance matching when worn on the body. Experimental comparisons using a simulated AEMW source demonstrated that the HBA outperformed a conventional small whip antenna, particularly at frequencies below 300 MHz. Furthermore, the outdoor measurements indicated that the power harvested by the HBA was estimated to be −31.9 dBm (0.64 μW), which is sufficient for the intermittent operation of low-power wearable sensors and Bluetooth Low Energy modules. The electromagnetic safety was also evaluated through numerical analysis, and the specific absorption rate was confirmed to be well below the international safety limits. These findings indicate that HBA-based AEMW energy harvesting provides a practical and promising approach to achieving battery-maintenance-free wearable devices.
- Open Access
A Novel Electromagnetic Response Measurement System for Continuous Monitoring of Meat Aging
The aging of dry meat enhances its flavor and tenderness; however, continuous internal quality monitoring throughout the aging process is challenging. We developed and validated a novel electromagnetic response measurement system for meat aging that enables continuous bioimpedance monitoring under stable, optimal temperature/humidity conditions. The system comprises a temperature-controlled dry aging fridge and a newly designed puncture-type semi-rigid coaxial probe, allowing for minimally invasive internal measurements over a broad frequency range. The probe achieved stable measurements across 10 kHz to 10 MHz, and its small diameter (1.25 mm) enabled almost non-destructive internal sensing. Beef and pork samples were monitored over 14 days via multi-channel bioimpedance measurements. After an initial stabilization period, bioimpedance steadily decreased throughout aging. This decline reflected progressive increases in tissue conductivity as cell membranes broke down and intracellular fluids leaked out. High-frequency measurements (e.g., around 10 MHz) were more sensitive to environmental disturbances. Periodic defrost cycles in the chamber caused temporary impedance dips at these frequencies, highlighting the influence of short-term temperature/humidity fluctuations. The system enables long-term continuous measurement without removing samples from the fridge, thus maintaining aging conditions during monitoring. Overall, the system enables the stable, long-term, and multi-channel electromagnetic monitoring of meat quality under optimal aging conditions—a capability not achieved in previous studies. This new method offers a minimally invasive, frequency-resolved approach for assessing meat quality evolution during aging. This advance demonstrates a new approach for tracking meat quality changes during dry aging.
Open AccessA Novel Electromagnetic Response Measurement System for Continuous Monitoring of Meat Aging
The aging of dry meat enhances its flavor and tenderness; however, continuous internal quality monitoring throughout the aging process is challenging. We developed and validated a novel electromagnetic response measurement system for meat aging that enables continuous bioimpedance monitoring under stable, optimal temperature/humidity conditions. The system comprises a temperature-controlled dry aging fridge and a newly designed puncture-type semi-rigid coaxial probe, allowing for minimally invasive internal measurements over a broad frequency range. The probe achieved stable measurements across 10 kHz to 10 MHz, and its small diameter (1.25 mm) enabled almost non-destructive internal sensing. Beef and pork samples were monitored over 14 days via multi-channel bioimpedance measurements. After an initial stabilization period, bioimpedance steadily decreased throughout aging. This decline reflected progressive increases in tissue conductivity as cell membranes broke down and intracellular fluids leaked out. High-frequency measurements (e.g., around 10 MHz) were more sensitive to environmental disturbances. Periodic defrost cycles in the chamber caused temporary impedance dips at these frequencies, highlighting the influence of short-term temperature/humidity fluctuations. The system enables long-term continuous measurement without removing samples from the fridge, thus maintaining aging conditions during monitoring. Overall, the system enables the stable, long-term, and multi-channel electromagnetic monitoring of meat quality under optimal aging conditions—a capability not achieved in previous studies. This new method offers a minimally invasive, frequency-resolved approach for assessing meat quality evolution during aging. This advance demonstrates a new approach for tracking meat quality changes during dry aging.
- Open Access
- 1 June 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (6)
Propagation analysis of implantable human body communication system for neurostimulators and structural evaluation of abdominal models
This paper presents a propagation analysis of an implantable human body communication (IHBC) system for neurostimulators and a structural evaluation of simplified abdominal models. Modern medicine relies on implantable medical devices to provide advanced diagnostics and treatments for patients. Communication between such devices and external devices is crucial for tailored medical services but suffers from high power consumption due to signal attenuation within biological tissues. In addition, electromagnetic interference with surrounding devices and security risks caused by unauthorized wireless access are also concerns. To address these issues, we previously proposed an IHBC system that utilizes biological tissues as a transmission medium, employing low-frequency bands to minimize signal attenuation and external radiation. This study focuses on communication between a neurostimulator implanted in the lower abdomen and an external controller. Electromagnetic field analysis using an anatomically accurate human body model was performed to elucidate the signal propagation mechanisms, and the transmission characteristics were evaluated for various implant depths and positions. Moreover, we propose simplified abdominal models to reduce computational resource demands while maintaining analytical accuracy. Our findings suggest that a three-layer abdominal model, consisting of skin, fat, and muscle, achieves a balance between computational efficiency and accuracy, demonstrating close agreement with anatomical models. These results provide critical insights for the design of IHBC systems and their practical applications.
- 1 June 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (6)
Open AccessPropagation analysis of implantable human body communication system for neurostimulators and structural evaluation of abdominal models
This paper presents a propagation analysis of an implantable human body communication (IHBC) system for neurostimulators and a structural evaluation of simplified abdominal models. Modern medicine relies on implantable medical devices to provide advanced diagnostics and treatments for patients. Communication between such devices and external devices is crucial for tailored medical services but suffers from high power consumption due to signal attenuation within biological tissues. In addition, electromagnetic interference with surrounding devices and security risks caused by unauthorized wireless access are also concerns. To address these issues, we previously proposed an IHBC system that utilizes biological tissues as a transmission medium, employing low-frequency bands to minimize signal attenuation and external radiation. This study focuses on communication between a neurostimulator implanted in the lower abdomen and an external controller. Electromagnetic field analysis using an anatomically accurate human body model was performed to elucidate the signal propagation mechanisms, and the transmission characteristics were evaluated for various implant depths and positions. Moreover, we propose simplified abdominal models to reduce computational resource demands while maintaining analytical accuracy. Our findings suggest that a three-layer abdominal model, consisting of skin, fat, and muscle, achieves a balance between computational efficiency and accuracy, demonstrating close agreement with anatomical models. These results provide critical insights for the design of IHBC systems and their practical applications.
- Open Access
- 28 February 2025
- Published by Science Publishing Group in International Journal of Sensors and Sensor Networks
- Vol. 13 (1) , 12-21
Adaptive Modulation and Coding Control Based on Human Body Channel Characteristics Under Different WBAN Scenarios
Wireless Body Area Network (WBAN) enables continuous health monitoring by interconnecting wearable and implantable sensors, but their links suffer from strongly scenario-dependent human-body propagation effects that conventional physical-layer (PHY) designs do not address. Most prior studies assess limited WBAN links, so a unified strategy that spans all scenarios remains missing. This work presents a comprehensive adaptation framework across all three IEEE 802.15.6ma communication scenarios with minimal feedback overhead, ensuring consistent performance under diverse channel conditions. This study aims to maximize WBAN throughput by adaptively selecting the modulation and coding scheme according to channel characteristics unique to three IEEE 802.15.6ma communication scenarios: 21 MHz on-body, 400 MHz in-body, and 2.4 GHz off-body. By leveraging finite-difference time-domain analysis on a detailed whole-body voxel model combined with a compact hybrid antenna, we capture realistic, wideband channel responses that reflect both on-skin and implanted device environments. Wide-band channel responses were first obtained with finite-difference time-domain analysis of the whole-body voxel model combined with a compact hybrid antenna that integrates galvanic electrodes and patch radiators. The channel responses were fed into link-level simulations covering BPSK, QPSK, GMSK and 16-QAM, with and without BCH (63, 51) coding. QPSK was most efficient at mid-range SNR, whereas coded 16-QAM became superior once E b /N 0 exceeded roughly 10 dB, boosting off-body throughput by up to 35%. Applying simple E b /N 0 thresholds (≈ 6-13 dB) to switch between QPSK and coded 16-QAM almost doubled the data rate versus a fixed conservative scheme while still meeting the error-free requirement of medical telemetry. These results highlight the practical benefits of our adaptive control approach for real-world WBAN deployments, including reduced power consumption and simplified transceiver design.
- 28 February 2025
- Published by Science Publishing Group in International Journal of Sensors and Sensor Networks
- Vol. 13 (1) , 12-21
Open AccessAdaptive Modulation and Coding Control Based on Human Body Channel Characteristics Under Different WBAN Scenarios
Wireless Body Area Network (WBAN) enables continuous health monitoring by interconnecting wearable and implantable sensors, but their links suffer from strongly scenario-dependent human-body propagation effects that conventional physical-layer (PHY) designs do not address. Most prior studies assess limited WBAN links, so a unified strategy that spans all scenarios remains missing. This work presents a comprehensive adaptation framework across all three IEEE 802.15.6ma communication scenarios with minimal feedback overhead, ensuring consistent performance under diverse channel conditions. This study aims to maximize WBAN throughput by adaptively selecting the modulation and coding scheme according to channel characteristics unique to three IEEE 802.15.6ma communication scenarios: 21 MHz on-body, 400 MHz in-body, and 2.4 GHz off-body. By leveraging finite-difference time-domain analysis on a detailed whole-body voxel model combined with a compact hybrid antenna, we capture realistic, wideband channel responses that reflect both on-skin and implanted device environments. Wide-band channel responses were first obtained with finite-difference time-domain analysis of the whole-body voxel model combined with a compact hybrid antenna that integrates galvanic electrodes and patch radiators. The channel responses were fed into link-level simulations covering BPSK, QPSK, GMSK and 16-QAM, with and without BCH (63, 51) coding. QPSK was most efficient at mid-range SNR, whereas coded 16-QAM became superior once E b /N 0 exceeded roughly 10 dB, boosting off-body throughput by up to 35%. Applying simple E b /N 0 thresholds (≈ 6-13 dB) to switch between QPSK and coded 16-QAM almost doubled the data rate versus a fixed conservative scheme while still meeting the error-free requirement of medical telemetry. These results highlight the practical benefits of our adaptive control approach for real-world WBAN deployments, including reduced power consumption and simplified transceiver design.
- Open Access
- 1 July 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (7)
Determining carrier frequency for implantable human body communication based on transmission efficiency–electromagnetic interference trade-off
This study proposes a novel methodology for determining the optimal carrier frequency for implantable human body communication (HBC) by focusing on the trade-off between transmission efficiency and electromagnetic interference (EMI) robustness. Traditional radio communication technologies use high-frequency bands, which pose some challenges, such as increased power consumption, EMI with other devices, and security risks. Implantable HBC is a promising alternative, wherein the human body is used as a transmission medium. Through phantom experiments simulating the human abdomen, we assess the transmission characteristics of implantable HBC between an abdominal neurostimulator and an external controller across a frequency range of 1–100 MHz. Results revealed that maximum transmission gain was achieved at 37.2 MHz. Moreover, rapid signal attenuation occurred beyond a minimal distance from the skin, indicating enhanced communication efficiency, reduced EMI, and enhanced information security. An evaluation index (EI) was also proposed to quantitatively assess the balance between transmission efficiency and EMI and determine an appropriate carrier frequency for specific implantable HBC applications. This study advances the field of implantable medical devices by optimizing communication performance while addressing key challenges in EMI and security.
- 1 July 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (7)
Open AccessDetermining carrier frequency for implantable human body communication based on transmission efficiency–electromagnetic interference trade-off
This study proposes a novel methodology for determining the optimal carrier frequency for implantable human body communication (HBC) by focusing on the trade-off between transmission efficiency and electromagnetic interference (EMI) robustness. Traditional radio communication technologies use high-frequency bands, which pose some challenges, such as increased power consumption, EMI with other devices, and security risks. Implantable HBC is a promising alternative, wherein the human body is used as a transmission medium. Through phantom experiments simulating the human abdomen, we assess the transmission characteristics of implantable HBC between an abdominal neurostimulator and an external controller across a frequency range of 1–100 MHz. Results revealed that maximum transmission gain was achieved at 37.2 MHz. Moreover, rapid signal attenuation occurred beyond a minimal distance from the skin, indicating enhanced communication efficiency, reduced EMI, and enhanced information security. An evaluation index (EI) was also proposed to quantitatively assess the balance between transmission efficiency and EMI and determine an appropriate carrier frequency for specific implantable HBC applications. This study advances the field of implantable medical devices by optimizing communication performance while addressing key challenges in EMI and security.
- Open Access
- 29 March 2024
- Published by MYU K.K. in Sensors and Materials
- Vol. 36 (3) , 1231-1241
Bioelectromagnetic-response-based Input Interface for Mobile Devices —Finger Identification Using Bioimpedance Characteristics—
- 29 March 2024
- Published by MYU K.K. in Sensors and Materials
- Vol. 36 (3) , 1231-1241
Open AccessBioelectromagnetic-response-based Input Interface for Mobile Devices —Finger Identification Using Bioimpedance Characteristics—