Miyu Kodama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Miyu Kodama has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Dairoku Muramatsu
The University of Electro-Communications , 1-5-1 Chofugaoka, Chofu, Tokyo 182-8585
5 shared publications Yukino Sasaki
The University of Electro-Communications, Chofu, Tokyo, Japan
1 shared publication
Latest Publications
- 10 October 2026
- Published by Springer Nature
- p. 134-142
A Fundamental Study of Inductive/Capacitive Hybrid WPT for Implantable Devices: Coupler Misalignment Tolerance
- 10 October 2026
- Published by Springer Nature
- p. 134-142
A Fundamental Study of Inductive/Capacitive Hybrid WPT for Implantable Devices: Coupler Misalignment Tolerance
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 102920-102928
Conductive-Embroidered Logo Antenna for Wearable Passive UHF RFID Tags
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 102920-102928
Open AccessConductive-Embroidered Logo Antenna for Wearable Passive UHF RFID Tags
- Open Access
- 1 June 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (6)
Propagation analysis of implantable human body communication system for neurostimulators and structural evaluation of abdominal models
This paper presents a propagation analysis of an implantable human body communication (IHBC) system for neurostimulators and a structural evaluation of simplified abdominal models. Modern medicine relies on implantable medical devices to provide advanced diagnostics and treatments for patients. Communication between such devices and external devices is crucial for tailored medical services but suffers from high power consumption due to signal attenuation within biological tissues. In addition, electromagnetic interference with surrounding devices and security risks caused by unauthorized wireless access are also concerns. To address these issues, we previously proposed an IHBC system that utilizes biological tissues as a transmission medium, employing low-frequency bands to minimize signal attenuation and external radiation. This study focuses on communication between a neurostimulator implanted in the lower abdomen and an external controller. Electromagnetic field analysis using an anatomically accurate human body model was performed to elucidate the signal propagation mechanisms, and the transmission characteristics were evaluated for various implant depths and positions. Moreover, we propose simplified abdominal models to reduce computational resource demands while maintaining analytical accuracy. Our findings suggest that a three-layer abdominal model, consisting of skin, fat, and muscle, achieves a balance between computational efficiency and accuracy, demonstrating close agreement with anatomical models. These results provide critical insights for the design of IHBC systems and their practical applications.
- 1 June 2025
- Published by AIP Publishing in AIP Advances
- Vol. 15 (6)
Open AccessPropagation analysis of implantable human body communication system for neurostimulators and structural evaluation of abdominal models
This paper presents a propagation analysis of an implantable human body communication (IHBC) system for neurostimulators and a structural evaluation of simplified abdominal models. Modern medicine relies on implantable medical devices to provide advanced diagnostics and treatments for patients. Communication between such devices and external devices is crucial for tailored medical services but suffers from high power consumption due to signal attenuation within biological tissues. In addition, electromagnetic interference with surrounding devices and security risks caused by unauthorized wireless access are also concerns. To address these issues, we previously proposed an IHBC system that utilizes biological tissues as a transmission medium, employing low-frequency bands to minimize signal attenuation and external radiation. This study focuses on communication between a neurostimulator implanted in the lower abdomen and an external controller. Electromagnetic field analysis using an anatomically accurate human body model was performed to elucidate the signal propagation mechanisms, and the transmission characteristics were evaluated for various implant depths and positions. Moreover, we propose simplified abdominal models to reduce computational resource demands while maintaining analytical accuracy. Our findings suggest that a three-layer abdominal model, consisting of skin, fat, and muscle, achieves a balance between computational efficiency and accuracy, demonstrating close agreement with anatomical models. These results provide critical insights for the design of IHBC systems and their practical applications.
- Open Access
- 1 July 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (7)
Determining carrier frequency for implantable human body communication based on transmission efficiency–electromagnetic interference trade-off
This study proposes a novel methodology for determining the optimal carrier frequency for implantable human body communication (HBC) by focusing on the trade-off between transmission efficiency and electromagnetic interference (EMI) robustness. Traditional radio communication technologies use high-frequency bands, which pose some challenges, such as increased power consumption, EMI with other devices, and security risks. Implantable HBC is a promising alternative, wherein the human body is used as a transmission medium. Through phantom experiments simulating the human abdomen, we assess the transmission characteristics of implantable HBC between an abdominal neurostimulator and an external controller across a frequency range of 1–100 MHz. Results revealed that maximum transmission gain was achieved at 37.2 MHz. Moreover, rapid signal attenuation occurred beyond a minimal distance from the skin, indicating enhanced communication efficiency, reduced EMI, and enhanced information security. An evaluation index (EI) was also proposed to quantitatively assess the balance between transmission efficiency and EMI and determine an appropriate carrier frequency for specific implantable HBC applications. This study advances the field of implantable medical devices by optimizing communication performance while addressing key challenges in EMI and security.
- 1 July 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (7)
Open AccessDetermining carrier frequency for implantable human body communication based on transmission efficiency–electromagnetic interference trade-off
This study proposes a novel methodology for determining the optimal carrier frequency for implantable human body communication (HBC) by focusing on the trade-off between transmission efficiency and electromagnetic interference (EMI) robustness. Traditional radio communication technologies use high-frequency bands, which pose some challenges, such as increased power consumption, EMI with other devices, and security risks. Implantable HBC is a promising alternative, wherein the human body is used as a transmission medium. Through phantom experiments simulating the human abdomen, we assess the transmission characteristics of implantable HBC between an abdominal neurostimulator and an external controller across a frequency range of 1–100 MHz. Results revealed that maximum transmission gain was achieved at 37.2 MHz. Moreover, rapid signal attenuation occurred beyond a minimal distance from the skin, indicating enhanced communication efficiency, reduced EMI, and enhanced information security. An evaluation index (EI) was also proposed to quantitatively assess the balance between transmission efficiency and EMI and determine an appropriate carrier frequency for specific implantable HBC applications. This study advances the field of implantable medical devices by optimizing communication performance while addressing key challenges in EMI and security.
- Open Access
- 1 August 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (8)
Signal transmission analysis in implantable human body communication for abdominal medical devices
Implantable medical devices, such as neurostimulators, need to be wirelessly controlled from outside the body. Many of these devices use high-frequency signals in the 400 MHz, 900 MHz, and 2.45 GHz bands to communicate with external devices. However, high-frequency bands can suffer from signal attenuation in biological tissues and from electromagnetic interference with surrounding devices. In contrast, human body communication (HBC) uses relatively low frequencies in the 3–30 MHz band, which can alleviate signal attenuation and prevent emissions outside the body during communication. In this study, we investigated the use of HBC for implantable medical devices in the abdomen using electromagnetic field simulations. The results showed that the transmission between the transmitter inside the body and the receiver outside the body was adequate for stable communication. However, when the receiver was detached from the skin surface, the transmission characteristics rapidly decreased. Moreover, when the receiver and skin were separated by 1 mm, the transmission degraded by 34 dB, indicating that electromagnetic interference between the implanted transmitter and surrounding devices (including other medical devices) is rare. Finally, we evaluated the proposed system from the perspective of medical electromagnetic compatibility and human safety. The simulation results demonstrated that the radiated emissions and human exposure of the HBC system meet international standards.
- 1 August 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (8)
Open AccessSignal transmission analysis in implantable human body communication for abdominal medical devices
Implantable medical devices, such as neurostimulators, need to be wirelessly controlled from outside the body. Many of these devices use high-frequency signals in the 400 MHz, 900 MHz, and 2.45 GHz bands to communicate with external devices. However, high-frequency bands can suffer from signal attenuation in biological tissues and from electromagnetic interference with surrounding devices. In contrast, human body communication (HBC) uses relatively low frequencies in the 3–30 MHz band, which can alleviate signal attenuation and prevent emissions outside the body during communication. In this study, we investigated the use of HBC for implantable medical devices in the abdomen using electromagnetic field simulations. The results showed that the transmission between the transmitter inside the body and the receiver outside the body was adequate for stable communication. However, when the receiver was detached from the skin surface, the transmission characteristics rapidly decreased. Moreover, when the receiver and skin were separated by 1 mm, the transmission degraded by 34 dB, indicating that electromagnetic interference between the implanted transmitter and surrounding devices (including other medical devices) is rare. Finally, we evaluated the proposed system from the perspective of medical electromagnetic compatibility and human safety. The simulation results demonstrated that the radiated emissions and human exposure of the HBC system meet international standards.