Matthieu Malatray
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Matthieu Malatray has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Cécile Batailler
Hôpital de la Croix-Rousse, Lyon, France
2 shared publications - Elliot Sappey-Marinier
Ramsay Santé, Hôpital Privé Jean Mermoz, Centre Orthopédique Santy, FIFA Medical Center of Excellence Lyon France
2 shared publications - Elvire Servien
Department of Orthopedic Surgery and Sport Medicine, Croix-Rousse Hospital, FIFA Medical Center of Excellence, Lyon, France
2 shared publications - John Swan
Department of Orthopedic Surgery and Sport Medicine, Croix-Rousse Hospital, Lyon, France
2 shared publications - Sébastien Lustig
Orthopaedic Department, Lyon North University Hospital, Hôpital de La Croix Rousse, Hospices Civils de Lyon, 103 Grande Rue de la Croix Rousse, 69004 Lyon, France
2 shared publications - Delphine Maucort-Boulch
Université de Lyon Lyon France
1 shared publication
Latest Publications
- 5 November 2020
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (2) , 603-611
No significant clinical and radiological differences between fixed versus mobile bearing total knee replacement using the same semi‐constrained implant type: a randomized controlled trial with mean 10 years follow‐up
Purpose: The aim of this study was to compare the long‐term clinical and radiological results between fixed (FB) and mobile bearing (MB) implants with identical design from the same manufacturer.Methods: From March 2007 to May 2009, we recruited 160 patients in a prospective, single centered, randomized controlled trial. The authors compared 81 FB total knee arthroplasty (TKA) versus 79 MB with medial compartment osteoarthritis. The same posterior stabilized HLS Noetos knee prosthesis (CORIN) was used in all patients. The two groups only differed by the tibial insert (fixed or mobile). The authors compared the postoperative Knee Society Score (KSS), the passive clinical and active radiological knee flexion, the implant survivorship, the complications, and the presence of radiolucent lines.Results: At mean 10.5 years’ follow‐up (range 8–12.1 years) no significant differences were found in clinical scores (KSS (p = 0.54), pain score (p = 0.77), stair climbing (p = 0.44), passive maximum flexion (p = 0.5)) or for radiological analyses (maximum active radiological flexion (p = 0.06), presence of progressive radiolucent lines (5 (MB group) versus 6 (FB group);p = 0.75)) between groups. No significant difference was found in overall implant survivorship (82% (MB group) versus 78% (FB group) p = 0.58) or complication rate (p = 0.32) at the last follow‐up.Conclusion: No significant clinical and radiological differences were found between fixed and mobile bearing TKA using the same semi‐constrained implant type with comparable overall survivorship. The choice between a fixed or mobile bearing implant should be based on surgeon preference and experience with the selected implant.Level of evidence: Prospective randomized controlled trial, Level II.
- 5 November 2020
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (2) , 603-611
No significant clinical and radiological differences between fixed versus mobile bearing total knee replacement using the same semi‐constrained implant type: a randomized controlled trial with mean 10 years follow‐up
Purpose: The aim of this study was to compare the long‐term clinical and radiological results between fixed (FB) and mobile bearing (MB) implants with identical design from the same manufacturer.Methods: From March 2007 to May 2009, we recruited 160 patients in a prospective, single centered, randomized controlled trial. The authors compared 81 FB total knee arthroplasty (TKA) versus 79 MB with medial compartment osteoarthritis. The same posterior stabilized HLS Noetos knee prosthesis (CORIN) was used in all patients. The two groups only differed by the tibial insert (fixed or mobile). The authors compared the postoperative Knee Society Score (KSS), the passive clinical and active radiological knee flexion, the implant survivorship, the complications, and the presence of radiolucent lines.Results: At mean 10.5 years’ follow‐up (range 8–12.1 years) no significant differences were found in clinical scores (KSS (p = 0.54), pain score (p = 0.77), stair climbing (p = 0.44), passive maximum flexion (p = 0.5)) or for radiological analyses (maximum active radiological flexion (p = 0.06), presence of progressive radiolucent lines (5 (MB group) versus 6 (FB group);p = 0.75)) between groups. No significant difference was found in overall implant survivorship (82% (MB group) versus 78% (FB group) p = 0.58) or complication rate (p = 0.32) at the last follow‐up.Conclusion: No significant clinical and radiological differences were found between fixed and mobile bearing TKA using the same semi‐constrained implant type with comparable overall survivorship. The choice between a fixed or mobile bearing implant should be based on surgeon preference and experience with the selected implant.Level of evidence: Prospective randomized controlled trial, Level II.
- 1 June 2020
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (2) , 428-436
Primary osteoarthritic knees have more varus coronal alignment of the femur compared to young non‐arthritic knees in a large cohort study
Purpose: Many surgeons are performing total knee arthroplasty (TKA) with an aim to reproducing native anatomical coronal alignment. Yet, it remains unclear if primary osteoarthritic and non‐osteoarthritic populations have similar knee coronal alignment. This study aims to describe and compare the distribution of femoral and tibial coronal alignment in a large primary osteoarthritic cohort and a young non‐osteoarthritic cohort.Methods: This is a retrospective analysis of a monocentric prospectively gathered data, from 1990 to 2019, of 2859 consecutive primary osteoarthritic knees in 2279 patients. Patients underwent standardized long‐leg radiographs. Femoral mechanical angle (FMA) and tibial mechanical angle (TMA) were digitally measured using software. Femoral, tibial and knee phenotypes were analyzed, and descriptive data were reported. Data were compared to a young non‐osteoarthritic population previously described.Results: In osteoarthritic knees, the mean FMA was 91° ± 2.9° (range 86°–100°) and the mean TMA was 87° ± 3.1° (range 80°–94°). No significant difference was observed for FMA and TMA between genders. The most common femoral and tibial phenotypes were varus (38.7%) and neutral (37.1%). The most frequent knee phenotype was a varus femoral phenotype with a neutral tibial phenotype (15.5%), which is different to the non‐osteoarthritic population.Conclusion: This study showed the wide distribution of knee phenotypes in a large osteoarthritic cohort. There was more varus distribution of the femoral coronal alignment compared to a non‐osteoarthritic population, suggesting consideration and potential adaptation of the realignment strategy of the femoral component during TKA.Level of evidence: III.
- 1 June 2020
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 30 (2) , 428-436
Primary osteoarthritic knees have more varus coronal alignment of the femur compared to young non‐arthritic knees in a large cohort study
Purpose: Many surgeons are performing total knee arthroplasty (TKA) with an aim to reproducing native anatomical coronal alignment. Yet, it remains unclear if primary osteoarthritic and non‐osteoarthritic populations have similar knee coronal alignment. This study aims to describe and compare the distribution of femoral and tibial coronal alignment in a large primary osteoarthritic cohort and a young non‐osteoarthritic cohort.Methods: This is a retrospective analysis of a monocentric prospectively gathered data, from 1990 to 2019, of 2859 consecutive primary osteoarthritic knees in 2279 patients. Patients underwent standardized long‐leg radiographs. Femoral mechanical angle (FMA) and tibial mechanical angle (TMA) were digitally measured using software. Femoral, tibial and knee phenotypes were analyzed, and descriptive data were reported. Data were compared to a young non‐osteoarthritic population previously described.Results: In osteoarthritic knees, the mean FMA was 91° ± 2.9° (range 86°–100°) and the mean TMA was 87° ± 3.1° (range 80°–94°). No significant difference was observed for FMA and TMA between genders. The most common femoral and tibial phenotypes were varus (38.7%) and neutral (37.1%). The most frequent knee phenotype was a varus femoral phenotype with a neutral tibial phenotype (15.5%), which is different to the non‐osteoarthritic population.Conclusion: This study showed the wide distribution of knee phenotypes in a large osteoarthritic cohort. There was more varus distribution of the femoral coronal alignment compared to a non‐osteoarthritic population, suggesting consideration and potential adaptation of the realignment strategy of the femoral component during TKA.Level of evidence: III.
- 27 November 2018
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 27 (8) , 2659-2664
Lateral retinacular release is not recommended in association to MPFL reconstruction in recurrent patellar dislocation
Reconstruction of the medial patellofemoral ligament (MPFL) has become the gold standard for the treatment of the recurrent patellar dislocation (RPD). Lateral retinacular release can be performed in association with MPFL reconstruction, but the effect on outcomes is not clear. To evaluate the effect of lateral release on outcomes following MPFL reconstruction is the aim of this study. It is hypothesized that isolated MPFL reconstruction was not inferior to MPFL reconstruction and lateral retinacular release in terms of IKDC subjective score and patellar tilt (PT).
- 27 November 2018
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 27 (8) , 2659-2664
Lateral retinacular release is not recommended in association to MPFL reconstruction in recurrent patellar dislocation
Reconstruction of the medial patellofemoral ligament (MPFL) has become the gold standard for the treatment of the recurrent patellar dislocation (RPD). Lateral retinacular release can be performed in association with MPFL reconstruction, but the effect on outcomes is not clear. To evaluate the effect of lateral release on outcomes following MPFL reconstruction is the aim of this study. It is hypothesized that isolated MPFL reconstruction was not inferior to MPFL reconstruction and lateral retinacular release in terms of IKDC subjective score and patellar tilt (PT).
- 1 November 2018
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 104 (7) , 1069-1072
Bone and parietal anterior iliac crest reconstruction for trans-iliac hernia after tricortical graft harvesting: An original technique
- 1 November 2018
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 104 (7) , 1069-1072
Bone and parietal anterior iliac crest reconstruction for trans-iliac hernia after tricortical graft harvesting: An original technique
- 1 September 2018
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 104 (5) , 725-731
Comparison of screw versus locked plate fixation for Scarf osteotomy treatment of hallux valgus
- 1 September 2018
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 104 (5) , 725-731
Comparison of screw versus locked plate fixation for Scarf osteotomy treatment of hallux valgus