LWLihai Wang

Lihai Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lihai Wang has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Deep learning-driven 3D reconstruction of internal wood defects from CT images

    by Guangqiang Xie, Yuanda Qi, Ping Zhang, Chunmei Yang, Yaoxiang Li, Lihai Wang


  • Open Access

    Interactive effects of temperature, moisture content, and decay on the electrical resistance of Populus ussuriensis wood

    by Xiaoquan Yue, Jun Yu, Hui Liu, Longhong Yuan, Wei Huang, Lihai Wang, Ye Sheng, Xiaolong Shi

    The study sought to examine the response of the logarithm of electrical resistance (log R ) of Populus ussuriensis wood to temperature fluctuations ranging from −20 to 20 °C and moisture content variations between 0 and over 100 %. Resistance tests were performed on 48 healthy and 72 decayed samples via a digital bridge. Studies revealed that temperatures dropping below the freezing point markedly affect the log R value of healthy wood, exhibiting an abrupt shift in the −5 to 0 °C spectrum. The log R of healthy wood was more significantly affected by the moisture content below the fiber saturation point (FSP). A comparison of the log R of decayed samples with that of healthy wood revealed a similar trend with the changes of temperature and moisture content. At the same temperature, the log R of healthy wood was a slightly higher than that of the decayed samples. The log R of healthy wood exhibited a slightly higher than that of decayed samples at same moisture content. The multivariate linear regression models established between moisture content, temperature, mass loss rate and log R when the mass loss rate ( E s ) was ≤10 % demonstrated a satisfactory fit, with coefficients of determination ( R 2 ) exceeding 0.7.


  • Open Access

    Bacillus velezensis BY6 Promotes Growth of Poplar and Improves Resistance Contributing to the Biocontrol of Armillaria solidipes

    by Ping Zhang, Guangqiang Xie, Lihai Wang, Yanqiu Xing

    To improve the application of endophyte Bacillus velezensis BY6 from the xylem of poplar, the effect of BY6 on the growth of diseased Populus davidiana × Populus. alba var. pyramidalis Louche (Pdpap poplar) seedlings and the biological control effect on the pathogen Armillaria solidipes were tested using a plant split-root experiment. After applying BY6 to the roots of diseased Pdpap poplar seedlings, the results show that plant growth indicators (dry mass, fresh mass, and plant height) were significantly increased (p < 0.05), and genes related to auxin hormone signal transcription were activated. BY6 indicated a surprising control effect after the inoculation of diseased Pdpap poplar seedlings. Compared to the infected control group, the treated disease index of the diseased Pdpap poplar seedlings in the treatment group were reduced by 49.53% on the 20th day. The relative staining areas of diaminobenzidine (DAB) and Trypan blue decreased by 3.37 and 7.31 times, respectively. The physiological indicators (soluble sugar and protein) and oxidase indicators were significantly increased (p < 0.05). The expression levels of defense genes related to salicylic acid (SA) and jasmonic acid (JA) signaling pathways were significantly increased (p < 0.05). Amazingly, the results indicate that BY6 simultaneously activates induced systemic resistance (ISR) and systemic acquired resistance (SAR) in diseased Pdpap poplar seedlings and promotes growth. The results indicate that BY6 is a promising candidate for developing forest tree biofertilizers and biopesticides.


  • Preparation of MC–CuS–PGr/PPy Nanocomposite Films via Strong Interfacial Interactions as a Battery‐Type Electrode

    by Sheng Gu, Shu Dong, Xue Wang, Xiaolong Shi, Guoqi Xu, Lihai Wang

    Flexible energy storage devices are an essential step towards the production of wearable and flexible electronic products. However, the design of flexible electrodes with excellent electrochemical performance still faces enormous challenges. This work reports a fabrication method for flexible electrodes. Specifically, the formation of MC‐CuS‐PGr/PPy nanocomposite films was driven by different interactions (including hydrogen bonds and π–π conjugated bonds). Nanocellulose@carbon nanotube (MC) acted as a flexible substrate and was encapsulated with polypyrrole (PPy), a hydrogen bond active site carrier. MC and PPy were interconnected through hydrogen bonds, and pencil graphite (PGr) was a secondary conductive network that served as a separating layer between CuS and PPy. Driven by the interaction, the nanocomposite film was a stable combination. The strong macromolecular interactions among MC, PPy, and PGr enhance conductivity and cycle life of this nanocomposite films. The water‐based hybrid cell was assembled based on an MC‐CuS‐PGr/PPy nanocomposite film, which exhibited high cyclability (capacity retention of 94.3% after 2000 cycles at 1 Ag−1) and provided an energy density of Wh kg−1 (at a power density of 549.8 W kg−1). This research provides a new idea for preparing new flexible electrodes.

  • Open Access

    Antagonistic Properties and Screening of Bacillus Velezensis Nhw-B72 against Wood Fungal Decay

    by Congxun Huang, Guoqi Xu, Lihai Wang, Ping Zhang, Pengwei Zhao, Yan Zhong

    (1) Background: Wood decay is a serious issue that results from the presence of wood-destroying fungi and has a great influence on the international wood industry. The utilization of biological control methods offers good prospects for wood preservation. (2) Methods: The plate-screening experiment, the soil block test of the Chinese stand method (GB/T 13942.1), and the characterization of wood blocks were used to achieve biological control of brown rot and white rot. (3) Results: Through isolation, screening, and identification, the antagonistic bacterium Bacillus velezensis Nhw-B72 strain was obtained. In the plate-screening experiment, the inhibition zone diameter of Nhw-B72 for Gloeophyllum trabeum was 1.68 cm and that for Coriolus versicolor was 2.33 cm. After inhibition, the morphology of mycelia was distorted, malformed, and broken. In the soil block test, the average weight loss percentage of wood blocks in the control group was 61.66%. In the treatment group, the average weight loss percentage of the wood blocks with drying was 28.18% and that of the wood blocks without drying was 34.97%. (4) Conclusions: The strain has an obvious antagonistic effect on the wood-destroying fungi and the sterile fermentative liquid can effectively inhibit wood decay. In addition, compared to the drying of wood blocks, the air-drying of blocks after impregnation with the fermentative liquid had a better inhibition effect.


  • Open Access

    Characterization of KH-560-Modified Jute Fabric/Epoxy Laminated Composites: Surface Structure, and Thermal and Mechanical Properties

    by Xue Wang, Lihai Wang, Wenwen Ji, Quanling Hao, Guanghui Zhang, Qingkai Meng

    In this study, jute fabrics were used to reinforce epoxy resin to prepare laminated composites. KH-560 silane coupling agent modification was used to improve the interfacial compatibility between fibers and epoxy. The effects of different immersion times (0 min, 10 min, 30 min, 60 min, 90 min, and 120 min) on the jute fiber’s element content, crystal structure, and thermal stability, and the mechanical properties of laminated composites were studied. X-ray diffractometry (XRD) analysis showed that the KH-560 modification improved the crystallinity index (CI) and crystallite sizes (CS) of jute fibers. Scanning electron microscopy (SEM) analysis of the tensile fracture surfaces revealed a thick epoxy on the modified pulled fiber surfaces. Fourier transform infrared spectroscopy (FTIR) and energy dispersive spectrometer (EDS) analysis identified the presence of silicon and C–O–Si/Si–O–Si cross-linked structures on the surface of modified jute fibers. These cross-linked structures improved the thermal stability and mechanical properties of the laminated composites. When the immersion time was 60 min, the CI, CS, tensile strength, tensile modulus, flexural strength, and flexural modulus of the modified samples were 42.39%, 3.62 nm, 34.6 ± 1.1 MPa, 2.11 ± 0.12 GPa, 83.7 ± 1.8 MPa, and 4.08 ± 0.12 GPa, respectively, which were better than that of unmodified and other modified composites.


  • Open Access

    Effect of Hot-Alkali Treatment on the Structure Composition of Jute Fabrics and Mechanical Properties of Laminated Composites

    by Xue Wang, Lulu Chang, Xiaolong Shi, Lihai Wang

    In this study, jute fabrics/epoxy-laminated composites were fabricated via a simple and effective manual layering. Hot-alkali treatment was used to pretreat jute fabrics to improve their interfacial compatibility. The effects of hot-alkali treatment with five concentrations (2%, 4%, 6%, 8% and 10%) on the composition, crystallinity and surface morphology of jute fibers, were analyzed with the aids of Fourier transform infrared spectroscopy (FTIR), X-ray diffractometry (XRD), and the scanning electron microscope (SEM). The mechanical properties (tensile and flexural) of laminated composites, and the morphology of the tensile fracture surface, were analyzed. The results indicated that the crystallinity index (CI) and crystallite size (CS) of the cellulose in jute fibers were improved, and there were three stages for CI and CS with the increase of alkali concentrations. Hot-alkali treatment improved the mechanical properties of laminated composites, especially for the 6% NaOH-treated jute fabric reinforced. The tensile strength, flexural strength, tensile modulus and flexural modulus of 6% NaOH-treated fabrics reinforced composites were enhanced by 37.5%, 72.3%, 23.2% and 72.2%, respectively, as compared with those of untreated fabrics reinforced composites. The fiber pull-out and the gaps of the tensile fracture surface were reduced after hot-alkali treatment.


  • Open Access

    Electric resistance tomography and stress wave tomography for decay detection in trees—a comparison study

    by Xiaoquan Yue, Lihai Wang, James P. Wacker, Zhiming Zhu

    Background: To ensure the safety of trees, two NDT (nondestructive testing) techniques, electric resistance tomography and stress wave tomography, were employed to quantitatively detect and characterize the internal decay of standing trees. Comparisons between those two techniques were done to make full use of the individual capability for decay detection. Methods: Eighty trees (40 Manchurian ash and 40 Populus simonii) were detected, then wood increment cores were obtained from each cross disc trial. The Dt, which was defined as the value determined by the mass loss ratio of each wood core, was regarded as the true severity of decay. Using ordinary least-squares regression to analyze the relationship between Dt and De (De was defined as the severity of decay determined by electric resistance tomography) and between Dt and Ds (Ds was defined as the severity of decay determined by stress wave tomography). Results: The results showed that both methods could estimate the severity of decay in trees. In terms of different stages of decay, when Dt < 30%, De had a strong positive correlation with Dt (R2 = 0.677, P < 0.01), while, when Dt ≥ 30%, Ds had a significant positive correlation relationship with Dt (R2 = 0.645, P < 0.01). Conclusion: Electric resistance tomography was better than stress wave tomography for testing in the early stages of decay, while stress wave tomography can be used effectively in the late stage of decay. It is suggested that each technique can be used in the practice of internal decay testing of standing trees based on decay stages and operating conditions.


  • Open Access

    Investigations on the Effects of Seasonal Temperature Changes on the Electrical Resistance of Living Trees

    by Xiaoquan Yue, Lihai Wang, Xiaolong Shi, Mingxian Xu, Zhiming Zhu

    In order to use the electrical resistance method to accurately and timely detect and evaluate the internal decay defects of living trees, the effects of the seasonal temperature and moisture content on the electrical resistance of standing trees were investigated. At the Northeast Forestry University Experimental Forest Farm, Harbin, Heilongjiang Province of China, Populus simonii Populus simonii Carr. and Larix gmelinii (Rupr.) Rupr. were selected as the objects and the electrical resistance of standing trees was tested through different seasons from December 2016 to December 2017. Meanwhile, the effects of changes in the seasonal temperatures (−20 to −10 °C, −10 to −5 °C, −5 to 0 °C, 0 to 5 °C, 5 to 10 °C, 10 to 15 °C, 15 to 25 °C) as well as changes in the moisture content (MC) (Populus simonii, MC ≥ 103%; Larix gmelinii, MC ≥ 77.5%) on the electrical resistance in the cross-sections of living trees were studied. The influence of temperature at different moisture contents, the moisture content at different temperatures, and their combined effects on electrical resistance were analyzed, following which a regression model was also established. The obtained results indicated that ambient temperature had a significant effect on the average value of electrical resistance in the cross-section of living trees when temperatures were below the freezing point. There was a sudden discontinuity near the freezing point, and logR (logarithm value of electrical resistance) in the cross-sections of sound trees and decayed trees changed in a similar trend with variations in the temperature. While the effect of moisture content on logR in the cross-sections of threes was insignificant at different temperatures because of the moisture content above FSP (fiber saturation point). It indicated that the temperature and moisture content had interactive effects on logR in the cross-sections. The binary linear regression model between moisture content, temperature, and logR was highly fitted with a correlation coefficient (R2) higher than 0.8. The outcome of this investigation indicates that when non-destructive testing is performed on living trees using electrical resistance at different seasonal temperatures, the measured results need to consider both the temperature and moisture content. For practical work, it is not recommended to consider testing living trees near the freezing point temperature using the electrical resistive tomography. Below the freezing point, the electrical resistance changes with temperature greatly relative to the normal temperature. Therefore, when performing the detection of electrical resistance, it is necessary to calibrate the effects of temperature