Xiaolong Shi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiaolong Shi has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Lihai Wang
College of Mechanical and Electrical Engineering, Northeast Forestry University, Harbin, People’s Republic of China
2 shared publications - Lulu Chang
College of Engineering and Technology, Northeast Forestry University, Harbin 150040, China
1 shared publication - Mingxian Xu
College of Engineering and Technology, Northeast Forestry University, Harbin 150040, Heilongjiang, China
1 shared publication - Xiaoquan Yue
College of Transportation and Civil Engineering , 12449 Fujian Agriculture and Forestry University , Fujian , 35002 , Fuzhou , China
1 shared publication - Xue Wang
College of Engineering and Technology, Northeast Forestry University, Harbin 150040, China
1 shared publication - Zhiming Zhu
College of Transportation and Civil Engineering, Fujian Agriculture and Forestry University, Fuzhou 35002, Fujian, China
1 shared publication
Latest Publications
- Open Access
Effect of Hot-Alkali Treatment on the Structure Composition of Jute Fabrics and Mechanical Properties of Laminated Composites
In this study, jute fabrics/epoxy-laminated composites were fabricated via a simple and effective manual layering. Hot-alkali treatment was used to pretreat jute fabrics to improve their interfacial compatibility. The effects of hot-alkali treatment with five concentrations (2%, 4%, 6%, 8% and 10%) on the composition, crystallinity and surface morphology of jute fibers, were analyzed with the aids of Fourier transform infrared spectroscopy (FTIR), X-ray diffractometry (XRD), and the scanning electron microscope (SEM). The mechanical properties (tensile and flexural) of laminated composites, and the morphology of the tensile fracture surface, were analyzed. The results indicated that the crystallinity index (CI) and crystallite size (CS) of the cellulose in jute fibers were improved, and there were three stages for CI and CS with the increase of alkali concentrations. Hot-alkali treatment improved the mechanical properties of laminated composites, especially for the 6% NaOH-treated jute fabric reinforced. The tensile strength, flexural strength, tensile modulus and flexural modulus of 6% NaOH-treated fabrics reinforced composites were enhanced by 37.5%, 72.3%, 23.2% and 72.2%, respectively, as compared with those of untreated fabrics reinforced composites. The fiber pull-out and the gaps of the tensile fracture surface were reduced after hot-alkali treatment.
Open AccessEffect of Hot-Alkali Treatment on the Structure Composition of Jute Fabrics and Mechanical Properties of Laminated Composites
In this study, jute fabrics/epoxy-laminated composites were fabricated via a simple and effective manual layering. Hot-alkali treatment was used to pretreat jute fabrics to improve their interfacial compatibility. The effects of hot-alkali treatment with five concentrations (2%, 4%, 6%, 8% and 10%) on the composition, crystallinity and surface morphology of jute fibers, were analyzed with the aids of Fourier transform infrared spectroscopy (FTIR), X-ray diffractometry (XRD), and the scanning electron microscope (SEM). The mechanical properties (tensile and flexural) of laminated composites, and the morphology of the tensile fracture surface, were analyzed. The results indicated that the crystallinity index (CI) and crystallite size (CS) of the cellulose in jute fibers were improved, and there were three stages for CI and CS with the increase of alkali concentrations. Hot-alkali treatment improved the mechanical properties of laminated composites, especially for the 6% NaOH-treated jute fabric reinforced. The tensile strength, flexural strength, tensile modulus and flexural modulus of 6% NaOH-treated fabrics reinforced composites were enhanced by 37.5%, 72.3%, 23.2% and 72.2%, respectively, as compared with those of untreated fabrics reinforced composites. The fiber pull-out and the gaps of the tensile fracture surface were reduced after hot-alkali treatment.
- Open Access
Investigations on the Effects of Seasonal Temperature Changes on the Electrical Resistance of Living Trees
In order to use the electrical resistance method to accurately and timely detect and evaluate the internal decay defects of living trees, the effects of the seasonal temperature and moisture content on the electrical resistance of standing trees were investigated. At the Northeast Forestry University Experimental Forest Farm, Harbin, Heilongjiang Province of China, Populus simonii Populus simonii Carr. and Larix gmelinii (Rupr.) Rupr. were selected as the objects and the electrical resistance of standing trees was tested through different seasons from December 2016 to December 2017. Meanwhile, the effects of changes in the seasonal temperatures (−20 to −10 °C, −10 to −5 °C, −5 to 0 °C, 0 to 5 °C, 5 to 10 °C, 10 to 15 °C, 15 to 25 °C) as well as changes in the moisture content (MC) (Populus simonii, MC ≥ 103%; Larix gmelinii, MC ≥ 77.5%) on the electrical resistance in the cross-sections of living trees were studied. The influence of temperature at different moisture contents, the moisture content at different temperatures, and their combined effects on electrical resistance were analyzed, following which a regression model was also established. The obtained results indicated that ambient temperature had a significant effect on the average value of electrical resistance in the cross-section of living trees when temperatures were below the freezing point. There was a sudden discontinuity near the freezing point, and logR (logarithm value of electrical resistance) in the cross-sections of sound trees and decayed trees changed in a similar trend with variations in the temperature. While the effect of moisture content on logR in the cross-sections of threes was insignificant at different temperatures because of the moisture content above FSP (fiber saturation point). It indicated that the temperature and moisture content had interactive effects on logR in the cross-sections. The binary linear regression model between moisture content, temperature, and logR was highly fitted with a correlation coefficient (R2) higher than 0.8. The outcome of this investigation indicates that when non-destructive testing is performed on living trees using electrical resistance at different seasonal temperatures, the measured results need to consider both the temperature and moisture content. For practical work, it is not recommended to consider testing living trees near the freezing point temperature using the electrical resistive tomography. Below the freezing point, the electrical resistance changes with temperature greatly relative to the normal temperature. Therefore, when performing the detection of electrical resistance, it is necessary to calibrate the effects of temperature
Open AccessInvestigations on the Effects of Seasonal Temperature Changes on the Electrical Resistance of Living Trees
In order to use the electrical resistance method to accurately and timely detect and evaluate the internal decay defects of living trees, the effects of the seasonal temperature and moisture content on the electrical resistance of standing trees were investigated. At the Northeast Forestry University Experimental Forest Farm, Harbin, Heilongjiang Province of China, Populus simonii Populus simonii Carr. and Larix gmelinii (Rupr.) Rupr. were selected as the objects and the electrical resistance of standing trees was tested through different seasons from December 2016 to December 2017. Meanwhile, the effects of changes in the seasonal temperatures (−20 to −10 °C, −10 to −5 °C, −5 to 0 °C, 0 to 5 °C, 5 to 10 °C, 10 to 15 °C, 15 to 25 °C) as well as changes in the moisture content (MC) (Populus simonii, MC ≥ 103%; Larix gmelinii, MC ≥ 77.5%) on the electrical resistance in the cross-sections of living trees were studied. The influence of temperature at different moisture contents, the moisture content at different temperatures, and their combined effects on electrical resistance were analyzed, following which a regression model was also established. The obtained results indicated that ambient temperature had a significant effect on the average value of electrical resistance in the cross-section of living trees when temperatures were below the freezing point. There was a sudden discontinuity near the freezing point, and logR (logarithm value of electrical resistance) in the cross-sections of sound trees and decayed trees changed in a similar trend with variations in the temperature. While the effect of moisture content on logR in the cross-sections of threes was insignificant at different temperatures because of the moisture content above FSP (fiber saturation point). It indicated that the temperature and moisture content had interactive effects on logR in the cross-sections. The binary linear regression model between moisture content, temperature, and logR was highly fitted with a correlation coefficient (R2) higher than 0.8. The outcome of this investigation indicates that when non-destructive testing is performed on living trees using electrical resistance at different seasonal temperatures, the measured results need to consider both the temperature and moisture content. For practical work, it is not recommended to consider testing living trees near the freezing point temperature using the electrical resistive tomography. Below the freezing point, the electrical resistance changes with temperature greatly relative to the normal temperature. Therefore, when performing the detection of electrical resistance, it is necessary to calibrate the effects of temperature