Shenglan Jing
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shenglan Jing has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Yonggang Lei
5 shared publicationsFei Wang
Taiyuan Univ Technol, Dept Bldg Environm & Energy Engn, Taiyuan 030024, Shanxi, Peoples R China
4 shared publicationsChongfang Song
Taiyuan Univ Technol, Dept Bldg Environm & Energy Engn, Taiyuan 030024, Shanxi, Peoples R China
3 shared publicationsZhuoyu Zan
Master Candidate, Dept. of Building Environment and Energy Engineering, Taiyuan Univ. of Technology, Taiyuan, Shanxi 030024, China
2 shared publicationsBaizhan Li
1 shared publication- Baizhan Li
Joint International Research Laboratory of Green Buildings and Built Environments (Ministry of Education), Chongqing University, Chongqing 400045, China
1 shared publication
Latest Publications
- 6 September 2026
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 113
Drag reduction mechanism and multi-parameter synergistic optimization of a double-walled elbows with integrated flow guides
- 6 September 2026
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 113
Drag reduction mechanism and multi-parameter synergistic optimization of a double-walled elbows with integrated flow guides
- 6 June 2025
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 106
Research on the steady-state position of the automatic spool of a self-operated flow control valve
- 6 June 2025
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 106
Research on the steady-state position of the automatic spool of a self-operated flow control valve
- 6 April 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 89
Stress performance analysis of the novel double-wall tee for district heating pipelines
- 6 April 2024
- Published by Elsevier in Journal of Building Engineering
- Vol. 89
Stress performance analysis of the novel double-wall tee for district heating pipelines
- 1 August 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Pipeline Systems Engineering and Practice
- Vol. 11 (3) , 04020028
Thermal Fatigue Analysis of the Secondary Network of District Heating Systems in China
Central heating is the main heating method in cities in northern China in winter, and it is also an important part of urban utilities. The safety of the heating pipe network operation is an important livelihood issue. Temperature fatigue damage of the central heating pipeline has a severe impact on the safe operation of the system, and reasonable estimation of the number of fatigue cycles during the service life of the pipeline is an essential link in the pipeline design of a district heating (DH) system. The temperature data of five typical secondary networks of heat exchanger stations in Jiancao District of Taiyuan City in four heating seasons were collected. The frequency of temperature change during operation was counted, and the maximum total temperature difference cycle number of pipelines was estimated. In this paper, the regression analysis method is adopted to fit the design equation of the number of temperature cycles of water supply and return pipelines in 30 years of service life, which provides a way of thinking for predicting the number of temperature difference fatigue cycles of pipelines in the design stage. In the calculation of the number of maximum total temperature difference cycles, the different values of temperature difference defining parameter and reference temperature difference are analyzed. The results show that the selection of temperature difference defining parameter can effectively distinguish the effect of large and small temperature difference on the number of fatigue cycles of pipelines; at the same time, the cyclic temperature difference is normalized within a specific range of design temperature difference, which overcomes the problem of simplifying the guidance of the operation parameters of the central heating system and makes the predicted maximum total temperature difference cycle have universal guiding significance in a specific heating area.- 1 August 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Pipeline Systems Engineering and Practice
- Vol. 11 (3) , 04020028
Thermal Fatigue Analysis of the Secondary Network of District Heating Systems in China
Central heating is the main heating method in cities in northern China in winter, and it is also an important part of urban utilities. The safety of the heating pipe network operation is an important livelihood issue. Temperature fatigue damage of the central heating pipeline has a severe impact on the safe operation of the system, and reasonable estimation of the number of fatigue cycles during the service life of the pipeline is an essential link in the pipeline design of a district heating (DH) system. The temperature data of five typical secondary networks of heat exchanger stations in Jiancao District of Taiyuan City in four heating seasons were collected. The frequency of temperature change during operation was counted, and the maximum total temperature difference cycle number of pipelines was estimated. In this paper, the regression analysis method is adopted to fit the design equation of the number of temperature cycles of water supply and return pipelines in 30 years of service life, which provides a way of thinking for predicting the number of temperature difference fatigue cycles of pipelines in the design stage. In the calculation of the number of maximum total temperature difference cycles, the different values of temperature difference defining parameter and reference temperature difference are analyzed. The results show that the selection of temperature difference defining parameter can effectively distinguish the effect of large and small temperature difference on the number of fatigue cycles of pipelines; at the same time, the cyclic temperature difference is normalized within a specific range of design temperature difference, which overcomes the problem of simplifying the guidance of the operation parameters of the central heating system and makes the predicted maximum total temperature difference cycle have universal guiding significance in a specific heating area.- 1 May 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Pipeline Systems Engineering and Practice
- Vol. 11 (2)
Thermal-Fatigue Analysis of District-Heating Pipelines in China
The temperature variation of the district heating (DH) pipelines during the operation is the most severe threat to the lifetime of the systems. The number of cycles used in the fatigue analysis in the European standard were based on the lEA projects, and there were no sufficient studies conducted in China. This paper aims to make reasonable estimations of the maximum number of temperature load cycles for DH pipelines in China. Based on the data, the rain flow cycle-counting algorithms were applied to calculate the number of full temperature cycles. The regression models of design lines between full temperature cycles and temperature variations were established. The maximum values for supply pipelines and return pipelines were obtained by using the design lines. The equivalent full action cycles ( and ) are about 200 cycles for supply pipelines and 136 cycles for return pipelines which are both less than 250 cycles recommended in the European standard. Using 200 for the supply pipelines and 136 for the return pipelines, the stress limits could increase from 707 to 750 MPa and from 707 to 823 MPa respectively.- 1 May 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Pipeline Systems Engineering and Practice
- Vol. 11 (2)
Thermal-Fatigue Analysis of District-Heating Pipelines in China
The temperature variation of the district heating (DH) pipelines during the operation is the most severe threat to the lifetime of the systems. The number of cycles used in the fatigue analysis in the European standard were based on the lEA projects, and there were no sufficient studies conducted in China. This paper aims to make reasonable estimations of the maximum number of temperature load cycles for DH pipelines in China. Based on the data, the rain flow cycle-counting algorithms were applied to calculate the number of full temperature cycles. The regression models of design lines between full temperature cycles and temperature variations were established. The maximum values for supply pipelines and return pipelines were obtained by using the design lines. The equivalent full action cycles ( and ) are about 200 cycles for supply pipelines and 136 cycles for return pipelines which are both less than 250 cycles recommended in the European standard. Using 200 for the supply pipelines and 136 for the return pipelines, the stress limits could increase from 707 to 750 MPa and from 707 to 823 MPa respectively.- 1 November 2019
- Published by Elsevier in Energy and Buildings
- Vol. 202
Thermal comfort and energy-saving potential in university classrooms during the heating season
- 1 November 2019
- Published by Elsevier in Energy and Buildings
- Vol. 202
Thermal comfort and energy-saving potential in university classrooms during the heating season
- 1 December 2018
- Published by Elsevier in Building and Environment
- Vol. 146, 166-176
Exploring the “black box” of thermal adaptation using information entropy
- 1 December 2018
- Published by Elsevier in Building and Environment
- Vol. 146, 166-176
Exploring the “black box” of thermal adaptation using information entropy
- 12 September 2012
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 22 (4) , 598-607
Impact of Relative Humidity on Thermal Comfort in a Warm Environment
Relative humidity is an important environmental factor that could affect thermal comfort in a building. The influence of relative humidity on thermal comfort was studied in an environment chamber. Twenty subjects, ten males and ten females, were engaged in the study and were exposed to nine combinations of air temperature and relative humidity. Skin temperatures on different parts of the body were monitored, and their thermal sensation was evaluated by questionnaire while their thermal environments were measured during the chamber tests. These results were evaluated by statistical analyses which indicate that for higher temperature, relative humidity could have a significant effect on skin temperature and thermal sensation. Higher humidity could cause a negative effect on the subject’s thermal comfort. To avoid causing discomfort, the relative humidity limit should be taken into consideration and there should be a humidity limit specified by the appropriate building code for the acceptable air temperature range to allow an appropriate control of indoor environment.
- 12 September 2012
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 22 (4) , 598-607
Impact of Relative Humidity on Thermal Comfort in a Warm Environment
Relative humidity is an important environmental factor that could affect thermal comfort in a building. The influence of relative humidity on thermal comfort was studied in an environment chamber. Twenty subjects, ten males and ten females, were engaged in the study and were exposed to nine combinations of air temperature and relative humidity. Skin temperatures on different parts of the body were monitored, and their thermal sensation was evaluated by questionnaire while their thermal environments were measured during the chamber tests. These results were evaluated by statistical analyses which indicate that for higher temperature, relative humidity could have a significant effect on skin temperature and thermal sensation. Higher humidity could cause a negative effect on the subject’s thermal comfort. To avoid causing discomfort, the relative humidity limit should be taken into consideration and there should be a humidity limit specified by the appropriate building code for the acceptable air temperature range to allow an appropriate control of indoor environment.