Yosi Apriani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yosi Apriani has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Ian Mochamad Sofian
Politeknik Pelayaran Banten
3 shared publications- Ian Mochamad Sofian
Department of Vessel Machinery, Poltektrans SDP Palembang, Banyuasin, Indonesia
3 shared publications Wiwin A Oktaviani
Jurusan Teknik Elektro Fakultas Teknik Universitas Muhammadiyah Palembang
3 shared publicationsZulkiffli Saleh
Universitas Muhammadiyah Palembang
2 shared publicationsZulkifli Saleh
Universitas Muhammadiyah Palembang
2 shared publicationsAbdi Marlizen
Universitas Muhammadiyah Palembang
1 shared publication
Latest Publications
- Open Access
- 30 December 2024
- Published by Universitas PGRI Palembang in JURNAL AMPERE
- Vol. 9 (2) , 150-161
Pemodelan Efisiensi Energi Panel Surya Berrdasarkan Variasi Suhu Dengan Algoritma Random Forest
When temperature increases, energy efficiency tends to decrease. This is because the materials in solar panels, especially photovoltaic cells, have characteristics that make them less efficient at converting solar energy into electrical energy when temperatures rise. By using the random forest research method and Rstudio software to help analyze it can be concluded that the temperature variation that has the most influence on power efficiency is light intensity with a contribution of 19%, then air temperature with 18%, humidity with 17.5%, wind speed with 14%. 5% and finally panel temperature with a contribution of 13%. This contribution is the contribution to the power produced by the effect of temperature on the power produced. at 10.13 the highest power was obtained, where the power produced was 164.48 Watts. With a light intensity of 431.44 cd (candela), air temperature of 41.9°C, humidity of 49.4%, wind speed of 0.2 m/s, and panel temperature of 35 °C
- 30 December 2024
- Published by Universitas PGRI Palembang in JURNAL AMPERE
- Vol. 9 (2) , 150-161
Open AccessPemodelan Efisiensi Energi Panel Surya Berrdasarkan Variasi Suhu Dengan Algoritma Random Forest
When temperature increases, energy efficiency tends to decrease. This is because the materials in solar panels, especially photovoltaic cells, have characteristics that make them less efficient at converting solar energy into electrical energy when temperatures rise. By using the random forest research method and Rstudio software to help analyze it can be concluded that the temperature variation that has the most influence on power efficiency is light intensity with a contribution of 19%, then air temperature with 18%, humidity with 17.5%, wind speed with 14%. 5% and finally panel temperature with a contribution of 13%. This contribution is the contribution to the power produced by the effect of temperature on the power produced. at 10.13 the highest power was obtained, where the power produced was 164.48 Watts. With a light intensity of 431.44 cd (candela), air temperature of 41.9°C, humidity of 49.4%, wind speed of 0.2 m/s, and panel temperature of 35 °C
- Open Access
- 30 December 2024
- Published by Universitas PGRI Palembang in JURNAL AMPERE
- Vol. 9 (2) , 124-132
Optimasi dan Uji Coba Prototype Pembangkit Listrik Tenaga Picohydro dengan Turbin Archimedes
Desain penelitian ini berfokus pada pengembangan pembangkit listrik tenaga pikohidro dengan menggunakan turbin Archimedes. Proses desain melibatkan pembuatan dan pembangunan pembangkit listrik tenaga pikohidro, dimulai dengan tinjauan literatur untuk mengumpulkan referensi yang relevan tentang Pembangkit Listrik Tenaga Pikohidro (PLTPH) dan memahami persiapan yang diperlukan sebelum memulai konstruksi. Pendekatan ini termasuk mengumpulkan data tentang pengoperasian pembangkit listrik tenaga pikohidro. Pada penelitian ini pengukuran yang dilakukan sebanyak 10 kali menghasilkan debit air rata-rata 0,46 m³/dtk, sehingga memungkinkan pembuatan prototipe pikohidro dengan head 1,3 meter, turbin ulir berdiameter 18 cm, tebal sudu 4 mm, jarak antar sudu 10 cm, 1 sudu, 7 lilitan, dan dan sudut bilah 25°. Kinerja prototipe dinilai dengan memeriksa efek debit air pada putaran turbin dan kecepatan generator. Hasilnya menunjukkan kecepatan putaran turbin sebesar 112,2 RPM dan kecepatan putaran generator sebesar 758,4 RPM, yang mengindikasikan bahwa debit air yang di dapatkan lebih tinggi akan meningkatkan kecepatan turbin dan kecepatan generator.
- 30 December 2024
- Published by Universitas PGRI Palembang in JURNAL AMPERE
- Vol. 9 (2) , 124-132
Open AccessOptimasi dan Uji Coba Prototype Pembangkit Listrik Tenaga Picohydro dengan Turbin Archimedes
Desain penelitian ini berfokus pada pengembangan pembangkit listrik tenaga pikohidro dengan menggunakan turbin Archimedes. Proses desain melibatkan pembuatan dan pembangunan pembangkit listrik tenaga pikohidro, dimulai dengan tinjauan literatur untuk mengumpulkan referensi yang relevan tentang Pembangkit Listrik Tenaga Pikohidro (PLTPH) dan memahami persiapan yang diperlukan sebelum memulai konstruksi. Pendekatan ini termasuk mengumpulkan data tentang pengoperasian pembangkit listrik tenaga pikohidro. Pada penelitian ini pengukuran yang dilakukan sebanyak 10 kali menghasilkan debit air rata-rata 0,46 m³/dtk, sehingga memungkinkan pembuatan prototipe pikohidro dengan head 1,3 meter, turbin ulir berdiameter 18 cm, tebal sudu 4 mm, jarak antar sudu 10 cm, 1 sudu, 7 lilitan, dan dan sudut bilah 25°. Kinerja prototipe dinilai dengan memeriksa efek debit air pada putaran turbin dan kecepatan generator. Hasilnya menunjukkan kecepatan putaran turbin sebesar 112,2 RPM dan kecepatan putaran generator sebesar 758,4 RPM, yang mengindikasikan bahwa debit air yang di dapatkan lebih tinggi akan meningkatkan kecepatan turbin dan kecepatan generator.
- Open Access
- 9 December 2024
- Published by Fakultas Teknik, Universitas Negeri Makassar in Jurnal Media Elektrik
- Vol. 22 (1) , 76-82
OPTIMIZING CROSSFLOW TURBINE BLADES FOR POWER ENHANCEMENT AT PICO HYDRO POWER PLANT (PLTPH) USING ANSYS FLUENT
Renewable energy has become an important solution in dealing with the problem of climate change and resource scarcity. This study aims to analyze the effect of variations in the number of Crossflow turbine blades on output power at the Pico Hydro Power Plant (PLTPH). PLTPH is a water-based power plant with less than 5 kW of power, ideal for remote areas. Simulations were performed using SolidWorks software for turbine geometry design, Computational Fluid Dynamics (CFD), and ANSYS Fluent for fluid flow simulation. The simulation results show that the number of spoons and the speed of the water flow have a significant impact on the power produced. The optimal configuration is found on a 20-blade turbine that produces a maximum power of 4,695 Watts at a flow rate of 6 m/s. These findings can guide the efficient design of Crossflow turbines for PLTPH applications in remote areas.
- 9 December 2024
- Published by Fakultas Teknik, Universitas Negeri Makassar in Jurnal Media Elektrik
- Vol. 22 (1) , 76-82
Open AccessOPTIMIZING CROSSFLOW TURBINE BLADES FOR POWER ENHANCEMENT AT PICO HYDRO POWER PLANT (PLTPH) USING ANSYS FLUENT
Renewable energy has become an important solution in dealing with the problem of climate change and resource scarcity. This study aims to analyze the effect of variations in the number of Crossflow turbine blades on output power at the Pico Hydro Power Plant (PLTPH). PLTPH is a water-based power plant with less than 5 kW of power, ideal for remote areas. Simulations were performed using SolidWorks software for turbine geometry design, Computational Fluid Dynamics (CFD), and ANSYS Fluent for fluid flow simulation. The simulation results show that the number of spoons and the speed of the water flow have a significant impact on the power produced. The optimal configuration is found on a 20-blade turbine that produces a maximum power of 4,695 Watts at a flow rate of 6 m/s. These findings can guide the efficient design of Crossflow turbines for PLTPH applications in remote areas.
- Open Access
- 20 April 2024
- Published by PT Formosa Cendekia Global in East Asian Journal of Multidisciplinary Research
- Vol. 3 (4) , 1501-1512
Modeling Design of Picohydro Power Generation System Using Crossflow Turbine
The goal of this project is to learn how to use a Crossflow turbine to create a Picohydro power plant system modeling. The manufacturing process, from design to evaluation, is the methodology employed. The turbine type utilized is a crossflow turbine, measuring 26 cm in outer diameter, 17.3 cm in inner diameter of the blade runner, and up to 35 pieces of blades. The calculations show that the distance between the blades is 2.3 cm, the blade length is 8.5 cm, the blade width is 4.4 cm, and the radius of curvature of the blade is 2.8 cm. The test results without load obtained the highest turbine rotation of 421 Rpm produces a voltage of 7.29 V before going through the boost converter.
- 20 April 2024
- Published by PT Formosa Cendekia Global in East Asian Journal of Multidisciplinary Research
- Vol. 3 (4) , 1501-1512
Open AccessModeling Design of Picohydro Power Generation System Using Crossflow Turbine
The goal of this project is to learn how to use a Crossflow turbine to create a Picohydro power plant system modeling. The manufacturing process, from design to evaluation, is the methodology employed. The turbine type utilized is a crossflow turbine, measuring 26 cm in outer diameter, 17.3 cm in inner diameter of the blade runner, and up to 35 pieces of blades. The calculations show that the distance between the blades is 2.3 cm, the blade length is 8.5 cm, the blade width is 4.4 cm, and the radius of curvature of the blade is 2.8 cm. The test results without load obtained the highest turbine rotation of 421 Rpm produces a voltage of 7.29 V before going through the boost converter.
- Open Access
- 6 January 2024
- Published by PT Berkah Tematik Mandiri in Jurnal SINTA: Sistem Informasi dan Teknologi Komputasi
- Vol. 1 (1) , 41-48
EVALUASI KINERJA TURBIN CROSSFLOW DENGAN JUMLAH SUDU 35
Potensi energi sumber daya air sangat tinggi karena menyimpan energi potensial dan kinetik. Energi mekanik dari air dapat digunakan untuk menghasilkan energi listrik. Kebutuhan akan listrik terus meningkat seiring dengan perbaikan kondisi ekonomi, pertumbuhan penduduk, dan percepatan pembangunan. Pembangunan memerlukan infrastruktur energi. Tujuan dari penelitian ini adalah untuk merancang model turbin crossflow yang akan dipasang pada sistem pembangkit listrik tenaga Picohydro (PLTPh), dengan cara menganalisis nilai outputnya baik analisis menggunakan beban maupun tanpa beban, serta menganalisis efisiensi yang dapat dihasilkan oleh model tersebut. Metode penelitian yang dilakukan terdiri dari beberapa tahapan penelitian, dimulai dari perencanaan dan desain jumlah sudu PLTPh, pembuatan alat penelitian, pengujian alat, tahapan analisis data uji serta evaluasi hasil penelitian yang telah di buat. Hasil dari pengujian menunjukkan bahwa Efisiensi dan kinerja model PLTPh yang dihasilkan model turbin Crossflow dengan jumlah sudu 35 adalah Daya air 88,2 Watt, Daya turbin 66,15 Watt, Daya terbangkitkan 49,61 Watt, dan Efisiensi Turbin 75%.
- 6 January 2024
- Published by PT Berkah Tematik Mandiri in Jurnal SINTA: Sistem Informasi dan Teknologi Komputasi
- Vol. 1 (1) , 41-48
Open AccessEVALUASI KINERJA TURBIN CROSSFLOW DENGAN JUMLAH SUDU 35
Potensi energi sumber daya air sangat tinggi karena menyimpan energi potensial dan kinetik. Energi mekanik dari air dapat digunakan untuk menghasilkan energi listrik. Kebutuhan akan listrik terus meningkat seiring dengan perbaikan kondisi ekonomi, pertumbuhan penduduk, dan percepatan pembangunan. Pembangunan memerlukan infrastruktur energi. Tujuan dari penelitian ini adalah untuk merancang model turbin crossflow yang akan dipasang pada sistem pembangkit listrik tenaga Picohydro (PLTPh), dengan cara menganalisis nilai outputnya baik analisis menggunakan beban maupun tanpa beban, serta menganalisis efisiensi yang dapat dihasilkan oleh model tersebut. Metode penelitian yang dilakukan terdiri dari beberapa tahapan penelitian, dimulai dari perencanaan dan desain jumlah sudu PLTPh, pembuatan alat penelitian, pengujian alat, tahapan analisis data uji serta evaluasi hasil penelitian yang telah di buat. Hasil dari pengujian menunjukkan bahwa Efisiensi dan kinerja model PLTPh yang dihasilkan model turbin Crossflow dengan jumlah sudu 35 adalah Daya air 88,2 Watt, Daya turbin 66,15 Watt, Daya terbangkitkan 49,61 Watt, dan Efisiensi Turbin 75%.
- Open Access
- 10 July 2023
- Published by Universitas Ahmad Dahlan in Jurnal Ilmiah Teknik Elektro Komputer dan Informatika
- Vol. 9 (3) , 693-707
Vessel Tracking System Based LoRa SX1278
This research presents a vessel tracking system that provides real-time coordinate and speed information. The idea behind the development of this system originated from Automatic Identification System (AIS) technology, which functions as a vessel monitoring system in maritime areas. The system aims to improve navigation safety, monitor vessel traffic, and maritime security. In Indonesia, AIS is regulated by the Ministry of Transportation. However, this technology has not yet been implemented in river waters. In addition, AIS is a complex and expensive system. In this research, geographic location detection information in the form of a vessel tracking system is obtained using the UBlox Neo-6M GPS module based on LoRa technology. The LoRa mechanism periodically sends location data and vessel speed from the node to the gateway. The data is then sent to the ThingSpeak server using the MQTT protocol. On the server, the data can be accessed for further analysis. The developed system shows that the research can be realized and the system functions properly through a series of experimental tests. While in the in situ test, the system displayed good performance on LoRa SF 7 configuration with a signal strength of -118 dBm within the communication range of 1000 meters. This result can be improved by considering the MAPL value of -138 dBm.
- 10 July 2023
- Published by Universitas Ahmad Dahlan in Jurnal Ilmiah Teknik Elektro Komputer dan Informatika
- Vol. 9 (3) , 693-707
Open AccessVessel Tracking System Based LoRa SX1278
This research presents a vessel tracking system that provides real-time coordinate and speed information. The idea behind the development of this system originated from Automatic Identification System (AIS) technology, which functions as a vessel monitoring system in maritime areas. The system aims to improve navigation safety, monitor vessel traffic, and maritime security. In Indonesia, AIS is regulated by the Ministry of Transportation. However, this technology has not yet been implemented in river waters. In addition, AIS is a complex and expensive system. In this research, geographic location detection information in the form of a vessel tracking system is obtained using the UBlox Neo-6M GPS module based on LoRa technology. The LoRa mechanism periodically sends location data and vessel speed from the node to the gateway. The data is then sent to the ThingSpeak server using the MQTT protocol. On the server, the data can be accessed for further analysis. The developed system shows that the research can be realized and the system functions properly through a series of experimental tests. While in the in situ test, the system displayed good performance on LoRa SF 7 configuration with a signal strength of -118 dBm within the communication range of 1000 meters. This result can be improved by considering the MAPL value of -138 dBm.
- Open Access
- 30 January 2023
- Published by PT Formosa Cendekia Global in Formosa Journal of Sustainable Research
- Vol. 2 (1) , 183-194
Iot Monitoring Using ESP8266 on Solar Powered Aerator
Shrimp is one of the prima donnas of Indonesia's mainstay exports from the fishery sector which needs to be improved both in terms of quality and quantity. The use of aerators as an effort to improve the quality and quantity of harvest used by pond farmers today generally still uses a manual system, where the operation of the aerator is still based on experience, not from the quality of dissolved oxygen in the pond needed by fish or shrimp in the pond. In this study, the application of an aerator to improve the quality of dissolved oxygen both in quality and quantity, is equipped with an IoT (Internet of things) method that can instruct the aerator to operate as desired using a smartphone. The components used in this tool consist of solar cell panels as renewable power plants, Aerator Pumps, and ESP8266 WiFi. In this data collection activity, in fluctuating weather conditions. Especially during rainy conditions, data retrieval is paused because test conditions do not allow it to produce a current data reading of 0 amperes. From the logger data recording, it can be seen that the highest current value that can be absorbed through solar panels is 2.40 Amperes obtained on day 3 of testing
- 30 January 2023
- Published by PT Formosa Cendekia Global in Formosa Journal of Sustainable Research
- Vol. 2 (1) , 183-194
Open AccessIot Monitoring Using ESP8266 on Solar Powered Aerator
Shrimp is one of the prima donnas of Indonesia's mainstay exports from the fishery sector which needs to be improved both in terms of quality and quantity. The use of aerators as an effort to improve the quality and quantity of harvest used by pond farmers today generally still uses a manual system, where the operation of the aerator is still based on experience, not from the quality of dissolved oxygen in the pond needed by fish or shrimp in the pond. In this study, the application of an aerator to improve the quality of dissolved oxygen both in quality and quantity, is equipped with an IoT (Internet of things) method that can instruct the aerator to operate as desired using a smartphone. The components used in this tool consist of solar cell panels as renewable power plants, Aerator Pumps, and ESP8266 WiFi. In this data collection activity, in fluctuating weather conditions. Especially during rainy conditions, data retrieval is paused because test conditions do not allow it to produce a current data reading of 0 amperes. From the logger data recording, it can be seen that the highest current value that can be absorbed through solar panels is 2.40 Amperes obtained on day 3 of testing
- Open Access
- 10 January 2023
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- Vol. 7 (2) , 72-80
Analisa Daya Terpasang Terhadap Beban Di Gedung Paldam II/Sriwijaya Palembang
Gedung Paldam II/Sriwijaya merupakan gedung perkantoran terkemuka yang menampung berbagai kegiatan dan acara sehari-hari. Ini berfungsi sebagai hub untuk operasi administrasi, menyediakan beragam layanan. Beban listrik gedung terdiri dari penerangan, pendingin (AC), peralatan elektronik, dan sumber listrik cadangan melalui outlet. Karena sifat beban yang berbeda-beda, konsumsi daya juga berfluktuasi. Untuk mendapatkan hasil anaisis daya yang tepat dan efisien maka pada penggunaan listrik gedung perlu perhitungan beban instalasi yang cermat dan pengukuran beban aktual dilakukan. Pengukuran dilakukan dengan tekun setiap hari dari tanggal 5 Maret sampai dengan 9 Maret 2020, dimulai pukul 08.00 WIB dan berakhir pada pukul 17.00 WIB. Berdasarkan perhitungan menyeluruh, beban terpasang ditemukan sekitar 16.500 watt. Tercatat, beban puncak terjadi pada 3 Maret 2020 pukul 14.00 WIB mencapai 15.488 watt. Selain itu, beban rata-rata selama periode pemantauan dihitung sebesar 10.843,8 watt. Faktor permintaan, mewakili proporsi daya aktual yang dikonsumsi relatif terhadap beban terhubung maksimum, ditetapkan sebesar 93,87% untuk Gedung Paldam II/Sriwijaya.
- 10 January 2023
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- Vol. 7 (2) , 72-80
Open AccessAnalisa Daya Terpasang Terhadap Beban Di Gedung Paldam II/Sriwijaya Palembang
Gedung Paldam II/Sriwijaya merupakan gedung perkantoran terkemuka yang menampung berbagai kegiatan dan acara sehari-hari. Ini berfungsi sebagai hub untuk operasi administrasi, menyediakan beragam layanan. Beban listrik gedung terdiri dari penerangan, pendingin (AC), peralatan elektronik, dan sumber listrik cadangan melalui outlet. Karena sifat beban yang berbeda-beda, konsumsi daya juga berfluktuasi. Untuk mendapatkan hasil anaisis daya yang tepat dan efisien maka pada penggunaan listrik gedung perlu perhitungan beban instalasi yang cermat dan pengukuran beban aktual dilakukan. Pengukuran dilakukan dengan tekun setiap hari dari tanggal 5 Maret sampai dengan 9 Maret 2020, dimulai pukul 08.00 WIB dan berakhir pada pukul 17.00 WIB. Berdasarkan perhitungan menyeluruh, beban terpasang ditemukan sekitar 16.500 watt. Tercatat, beban puncak terjadi pada 3 Maret 2020 pukul 14.00 WIB mencapai 15.488 watt. Selain itu, beban rata-rata selama periode pemantauan dihitung sebesar 10.843,8 watt. Faktor permintaan, mewakili proporsi daya aktual yang dikonsumsi relatif terhadap beban terhubung maksimum, ditetapkan sebesar 93,87% untuk Gedung Paldam II/Sriwijaya.
- Open Access
- 27 October 2022
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- Vol. 7 (1) , 31-39
Pengaruh Kontingensi Saluran (N-1) pada Tegangan Bus Sistem 70 kV Palembang
Kemungkinan kejadian yang diakibatkan kegagalan satu atau lebih komponen jaringan seperti keluarnya satu saluran dari sistem disebut dengan kontingensi saluran (N-1). Keluarnya salah satu saluran transmisi dari sistem tenaga listrik baik yang disebabkan oleh gangguan atau pemeliharaan dapat menyebabkan terjadinya perubahan-perubahan dalam sistem seperti naik atau turunnya tegangan yang diluar batas standar dan pembebanan lebih pada saluran. Keaman suatu sistem tenaga apabila salah satu saluranya keluar dari sistem dapat ditinjau dengan analisa kontingensi saluran. Dalam simulasi ini konfigurasi jaringan transmisi disesuaikan dengan sejumlah skema kontingensi saluran N-1 yang telah ditetapkan. Ada 3 skema kontingensi yang disajikan dari 10 skema yang telah ditetapkan, yaitu satu skema operasi normal dan dua skema kontingensi yang menyebabkan sistem dalam kondisi tidak aman untuk beroperasi. Simulasi ini bertujuan untuk meninjau perubahan profil tegangan setiap bus baik dalam keadaan normal maupun dalam kondisi kontingensi. Hasil simulasi aliran daya untuk skema operasi 0 (kondisi Normal) memperlihatkan bahwa profil tegangan setiap bus masih dalam kondisi aman. Dimana peningkatan tegangan yang tertinggi pada bus 8 dengan besar tegangan 70,90 kV atau 1.3% lebih tinggi dari tegangan nominal 70 kV. Sedangkan penurunan tegangan yang terendah pada bus 7 dengan nilai tegangan 67,32 kV atau 3,83% lebih rendah dari tegangan nominal. Dari 10 skema simulasi kontingensi saluran yang dilakukan ada dua skema yang tidak aman untuk opersi sistem yaitu skema 6 dan skema 2 berdasarkan urutan. Sedangkan 8 skema lainya relatif aman untuk opersi sistem karena peningkatan dan penurunan tegangan tidak melampaui nilai deviasi dari tengangan nominal (berdasarkan Peraturan Menteri Energi dan Sumber Daya Mineral Nomor : 03 Tahun 2007 : CC 2.1).
- 27 October 2022
- Published by Universitas Muhammadiyah Palembang in JURNAL SURYA ENERGY
- Vol. 7 (1) , 31-39
Open AccessPengaruh Kontingensi Saluran (N-1) pada Tegangan Bus Sistem 70 kV Palembang
Kemungkinan kejadian yang diakibatkan kegagalan satu atau lebih komponen jaringan seperti keluarnya satu saluran dari sistem disebut dengan kontingensi saluran (N-1). Keluarnya salah satu saluran transmisi dari sistem tenaga listrik baik yang disebabkan oleh gangguan atau pemeliharaan dapat menyebabkan terjadinya perubahan-perubahan dalam sistem seperti naik atau turunnya tegangan yang diluar batas standar dan pembebanan lebih pada saluran. Keaman suatu sistem tenaga apabila salah satu saluranya keluar dari sistem dapat ditinjau dengan analisa kontingensi saluran. Dalam simulasi ini konfigurasi jaringan transmisi disesuaikan dengan sejumlah skema kontingensi saluran N-1 yang telah ditetapkan. Ada 3 skema kontingensi yang disajikan dari 10 skema yang telah ditetapkan, yaitu satu skema operasi normal dan dua skema kontingensi yang menyebabkan sistem dalam kondisi tidak aman untuk beroperasi. Simulasi ini bertujuan untuk meninjau perubahan profil tegangan setiap bus baik dalam keadaan normal maupun dalam kondisi kontingensi. Hasil simulasi aliran daya untuk skema operasi 0 (kondisi Normal) memperlihatkan bahwa profil tegangan setiap bus masih dalam kondisi aman. Dimana peningkatan tegangan yang tertinggi pada bus 8 dengan besar tegangan 70,90 kV atau 1.3% lebih tinggi dari tegangan nominal 70 kV. Sedangkan penurunan tegangan yang terendah pada bus 7 dengan nilai tegangan 67,32 kV atau 3,83% lebih rendah dari tegangan nominal. Dari 10 skema simulasi kontingensi saluran yang dilakukan ada dua skema yang tidak aman untuk opersi sistem yaitu skema 6 dan skema 2 berdasarkan urutan. Sedangkan 8 skema lainya relatif aman untuk opersi sistem karena peningkatan dan penurunan tegangan tidak melampaui nilai deviasi dari tengangan nominal (berdasarkan Peraturan Menteri Energi dan Sumber Daya Mineral Nomor : 03 Tahun 2007 : CC 2.1).
- Open Access
- 27 December 2021
- Published by Universitas Negeri Yogyakarta in Elinvo (Electronics, Informatics, and Vocational Education)
- Vol. 6 (2) , 174-182
The Automatic Monitoring System for WPP, SPP, and PLN based on The Internet of Things (IoT) using Sonoff Pow R2
The usefulness of monitoring systems in the electric power system supports the importance of people's work today. One of which is the monitoring system at the generator. The monitoring system for Wind Power Plant (WPP), Solar Power Plant (SPP), and electricity from State Electricity Company (PLN) use IoT (Internet of Things) in the form of Sonoff Pow R2. With the monitoring system on this tool, the parameter values for WPP, SPP, and PLN can be seen and monitored online via a smartphone. The purpose of this research is to design a monitoring system for WPP, SPP, and PLN based on the Internet of Things (IoT) to determine the value of the output power. In addition, this system can distinguish load parameter values when WPP, SPP, and PLN are supplied directly (real time) and monitored online using the Sonoff Pow R2 app and the Ewelink App. This study uses the methodology that started the process of designing and manufacturing systems and designing the wiring that has been formed from the process of making tools and testing results. The results obtained from the experiment show that the current values in WPP, SPP, and PLN that appear on the monitoring screen are stable. The stable condition values are measured and tested when power is used when loading through sonoff. For the power value, the power value in PLN is stable, whereas in WPP and SPP has increased. For the voltage, the voltage value from PLN does not reach 220 V, whereas the voltage value from WPP and SPP reaches a value of 220 V.
- 27 December 2021
- Published by Universitas Negeri Yogyakarta in Elinvo (Electronics, Informatics, and Vocational Education)
- Vol. 6 (2) , 174-182
Open AccessThe Automatic Monitoring System for WPP, SPP, and PLN based on The Internet of Things (IoT) using Sonoff Pow R2
The usefulness of monitoring systems in the electric power system supports the importance of people's work today. One of which is the monitoring system at the generator. The monitoring system for Wind Power Plant (WPP), Solar Power Plant (SPP), and electricity from State Electricity Company (PLN) use IoT (Internet of Things) in the form of Sonoff Pow R2. With the monitoring system on this tool, the parameter values for WPP, SPP, and PLN can be seen and monitored online via a smartphone. The purpose of this research is to design a monitoring system for WPP, SPP, and PLN based on the Internet of Things (IoT) to determine the value of the output power. In addition, this system can distinguish load parameter values when WPP, SPP, and PLN are supplied directly (real time) and monitored online using the Sonoff Pow R2 app and the Ewelink App. This study uses the methodology that started the process of designing and manufacturing systems and designing the wiring that has been formed from the process of making tools and testing results. The results obtained from the experiment show that the current values in WPP, SPP, and PLN that appear on the monitoring screen are stable. The stable condition values are measured and tested when power is used when loading through sonoff. For the power value, the power value in PLN is stable, whereas in WPP and SPP has increased. For the voltage, the voltage value from PLN does not reach 220 V, whereas the voltage value from WPP and SPP reaches a value of 220 V.