Guoliang Zhao
Guoliang Zhao has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Benfeng Gao
North China Electric Power University - Baoding Campus, 91630 Baoding, Hebei, China
1 shared publication - Ren Li
State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources North China Electric Power University Hebei Baoding People's Republic of China
1 shared publication - Ruixue Zhang
Department of Electrical Engineering, North China Electric Power University, Baoding 071003, China
1 shared publication - Shengjun Zhou
State Key Laboratory of Advanced Power Transmission Technology, Global Energy Interconnection Research Institute (GEIRI), Beijing 102209, China
1 shared publication - Tongxun Wang
State Key Laboratory of Advanced Power Transmission Technology, Global Energy Interconnection Research Institute (GEIRI), Beijing 102209, China
1 shared publication - Yaqiong Li
State Key Laboratory of Advanced Power Transmission Technology, Global Energy Interconnection Research Institute (GEIRI), Beijing 102209, China
1 shared publication
Latest Publications
- Open Access
Coupled Harmonic Admittance Identification Based on Least Square Estimation
Norton equivalent circuit is a commonly used model in estimating harmonic current emissions of harmonic sources. It however cannot reflect the mutual coupling relationships among voltage and current in different harmonic orders. This paper proposes a new method to identify parameters in a coupled harmonic admittance model. The proposed method is conducted using voltage and current measurements and is based on least square estimation technique. The effectiveness of the method is verified through time-domain simulations for a grid-connected converter and also through field data obtained from a ±800 kV converter station. The experimental results showed that the proposed method presents higher accuracy in terms of harmonic current emission estimation compared with three Norton-base methods.
Open AccessCoupled Harmonic Admittance Identification Based on Least Square Estimation
Norton equivalent circuit is a commonly used model in estimating harmonic current emissions of harmonic sources. It however cannot reflect the mutual coupling relationships among voltage and current in different harmonic orders. This paper proposes a new method to identify parameters in a coupled harmonic admittance model. The proposed method is conducted using voltage and current measurements and is based on least square estimation technique. The effectiveness of the method is verified through time-domain simulations for a grid-connected converter and also through field data obtained from a ±800 kV converter station. The experimental results showed that the proposed method presents higher accuracy in terms of harmonic current emission estimation compared with three Norton-base methods.
- Open Access
Subsynchronous Torsional Interaction of Wind Farms with FSIG Wind Turbines Connected to LCC-HVDC Lines
High-voltage direct current (HVDC) lines with line-commutated converter (LCC) are being increasingly employed to transmit bulk wind power over long distance. However, this may cause the sub-synchronous torsional interaction (SSTI) between the wind farms and the LCC-HVDC system. The SSTI characteristics of wind farms with fixed-speed induction generator (FSIG) wind turbines connected to LCC-HVDC are investigated in this paper. To simplify the calculations, a modular modeling method is proposed for building the small-signal mathematical model of the investigated system. Small-signal analysis, participation factor analysis, and impact of dominant factors analysis are then applied to investigate the SSTI characteristics under different operating conditions. Three oscillation modes associated with the SSTI are identified in the entire system through small-signal and participation factor analysis, comprising two torsional modes and an electromechanical mode. Impact of dominant factors analysis shows that the system becomes less stable as the wind farm capacity grows and the distance between FSIG wind farm and the rectifier station increases. Moreover, the above analysis suggests that wind farms with FSIG connected to LCC-HVDC lines may not cause unstable SSTI. The electromagnetic transient simulations based on PSCAD/EMTDC (Power Systems Computer-Aided Design/Electromagnetic Transients including DC) verify these results.
Open AccessSubsynchronous Torsional Interaction of Wind Farms with FSIG Wind Turbines Connected to LCC-HVDC Lines
High-voltage direct current (HVDC) lines with line-commutated converter (LCC) are being increasingly employed to transmit bulk wind power over long distance. However, this may cause the sub-synchronous torsional interaction (SSTI) between the wind farms and the LCC-HVDC system. The SSTI characteristics of wind farms with fixed-speed induction generator (FSIG) wind turbines connected to LCC-HVDC are investigated in this paper. To simplify the calculations, a modular modeling method is proposed for building the small-signal mathematical model of the investigated system. Small-signal analysis, participation factor analysis, and impact of dominant factors analysis are then applied to investigate the SSTI characteristics under different operating conditions. Three oscillation modes associated with the SSTI are identified in the entire system through small-signal and participation factor analysis, comprising two torsional modes and an electromechanical mode. Impact of dominant factors analysis shows that the system becomes less stable as the wind farm capacity grows and the distance between FSIG wind farm and the rectifier station increases. Moreover, the above analysis suggests that wind farms with FSIG connected to LCC-HVDC lines may not cause unstable SSTI. The electromagnetic transient simulations based on PSCAD/EMTDC (Power Systems Computer-Aided Design/Electromagnetic Transients including DC) verify these results.