CJChoon-Sik Jhun

Choon-Sik Jhun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Choon-Sik Jhun has a total of 39 co-authors. Here are the top co-authors by number of shared publications:

  • Gerson Rosenberg

    Division of Applied Biomedical Engineering, Department of Surgery, College of Medicine, Penn State University, Hershey, Pennsylvania

    6 shared publications
  • Eric Yeager

    Division of Applied Biomedical Engineering, Department of Surgery, College of Medicine, Penn State University, Hershey, Pennsylvania

    5 shared publications
  • Joshua P. Cysyk

    Division of Applied Biomedical Engineering, Department of Surgery, College of Medicine, Penn State University, Hershey, Pennsylvania

    5 shared publications
  • Lichong Xu

    Division of Applied Biomedical Engineering, Department of Surgery, College of Medicine, Penn State University, Hershey, Pennsylvania

    5 shared publications
  • Branka Lukic

    The Division of Applied Biomedical Engineering, Department of Surgery, College of Medicine, Penn State University, Hershey, Pennsylvania

    4 shared publications
  • Christopher M. Scheib

    Division of Applied Biomedical Engineering, Department of Surgery, College of Medicine, Penn State University, Hershey, Pennsylvania

    4 shared publications

Latest Publications

  • Clinically Motivated Redesign of the Pennsylvania State University Child Ventricular Assist Device

    by Christopher M. Scheib, Eric E. Yeager, Lichong Xu, Christopher A. Siedlecki, Joshua P. Cysyk, Karl O. Bohnenberger, Choon-Sik J. Jhun

    Building on validated in vitro and chronic in vivo testing of the Penn State University (PSU) Child Ventricular Assist Device (CVAD), the four-bladed prototype rotor (Rev 0.0) was redesigned using established analytical and computational methods to improve hydraulic efficiency while preserving hemodynamic performance and biocompatibility. Applying turbomachinery principles at the nominal operating condition (3 liters/minute [LPM], 8,000 revolutions/minute [RPM]), a five-bladed design (Rev 1.0) was created with an ideal inflow angle ( β 1 = 41.0°) and outflow angle ( β 2 = 27.4°). In silico simulations of Rev 1.0 across the prototype’s operating range (7,000–9,000 RPM, 1–5 LPM) demonstrated an approximately 40% improvement in hydraulic performance. The Rev 1.0 rotor was then evaluated on a benchtop mock circulatory loop using fresh ovine blood, confirming the in silico gains. The normalized index of hemolysis (NIH), measured at two clinically relevant conditions (1.5 LPM and 3.3 LPM, both at ~80 mm Hg), was 0.052 ± 0.054 and 0.047 ± 0.033 mg/dL, respectively, and high-molecular-weight multimers of von Willebrand factor were preserved within normal to borderline ranges. By achieving target flows and pressures at approximately 1,000 RPM lower speeds, the redesign reduces power requirements and enables longer untethered operation, advancing a fully implantable PSU CVAD toward a critical unmet need in pediatric advanced heart failure.

  • Preliminary Long-Term Biocompatibility Assessment of Penn State University Child Pump

    by Choon-Sik Jhun, Joseph B. Clark, Javier I. Gentile, Joshua P. Cysyk, Karl Bohnenberger, Christopher M. Scheib, Jenelle Izer, Matthew Lanza, Mindy Tillinger, Heidi Flory, et al.


  • Development of the PSU Child Pump

    by Christopher Scheib, Raymond Newswanger, Joshua Cysyk, Karl Bohnenberger, Branka Lukic, Lichong Xu, Eric Yeager, Kirby Bletcher, Patrick Leibich, Quandashia Jackson, et al.

    The Pennsylvania State University (PSU) Child Pump, a centrifugal continuous-flow ventricular assist device (cf-VAD), is being developed as a suitable long-term implantable device for pediatric heart failure patients between 10 and 35 kg, body surface area (BSA) of 0.5–1.2 m2, 1–11 years of age, and requiring a mean cardiac output of 1.0–3.5 L/min. In-vitro hydraulic and hemodynamic performances were evaluated on a custom mock circulatory loop with ovine blood. Normalized index of hemolysis (NIH) was evaluated under four conditions: 1) 8,300 rpm, 3.5 L/min, ΔP = 60 mm Hg, 2) 8,150 rpm, 5.1 L/min, ΔP = 20 mm Hg, 3) 8,400 rpm, 3.2 L/min, ΔP = 70 mm Hg, and 4) 9,850 rpm, 5.0 L/min, ΔP = 80 mm Hg, resulting in normalized index of hemolysis = 0.027 ± 0.013, 0.015 ± 0.006, 0.016 ± 0.008, and 0.026 ± 0.011 mg/dl, respectively. A mock fit study was conducted using a three-dimensional printed model of a 19 kg patient’s thoracic cavity to compare the size of the PSU Child Pump to the HeartMate3 and the HVAD. Results indicate the PSU Child Pump will be a safer, appropriately sized device capable of providing the given patient cohort proper support while minimizing the risks of blood trauma as they wait for a transplant.


  • Open Access

    P14: Degradation of High Molecular Weight Multimers of von Willebrand Factor under Whole Blood Conditions in High Turbulent Flow: Implications for Continuous Flow Left Ventricular Assist Devices

    by Choon-Sik Jhun, Lichong Xu, Eric Yeager, Karl Bohnenberger, Branka Lukic, Christopher M. Scheib, Christopher A. Siedlecki, Carlo R. Bartoli, Raymond K. Newswanger, Joshua P. Cysyk, et al.

  • Kinetic and Dynamic Effects on Degradation of von Willebrand Factor

    by Choon-Sik Jhun, Lichong Xu, Christopher Siedlecki, Carlo R. Bartoli, Eric Yeager, Branka Lukic, Christopher M. Scheib, Raymond Newswanger, Joshua P. Cysyk, Chan Shen, et al.

    The loss of high molecular weight multimers (HMWM) of von Willebrand factor (vWF) in aortic stenosis (AS) and continuous-flow left ventricular assist devices (cf-LVADs) is believed to be associated with high turbulent blood shear. The objective of this study is to understand the degradation mechanism of HMWM in terms of exposure time (kinetic) and flow regime (dynamics) within clinically relevant pathophysiologic conditions. A custom high-shear rotary device capable of creating fully controlled exposure times and flows was used. The system was set so that human platelet-poor plasma flowed through at 1.75 ml/sec, 0.76 ml/sec, or 0.38 ml/sec resulting in the exposure time (t exp ) of 22, 50, or 100 ms, respectively. The flow was characterized by the Reynolds number (Re). The device was run under laminar (Re = 1,500), transitional (Re = 3,000; Re = 3,500), and turbulent (Re = 4,500) conditions at a given t exp followed by multimer analysis. No degradation was observed at laminar flow at all given t exp . Degradation of HMWM at a given t exp increases with the Re. Re (p < 0.0001) and t exp (p = 0.0034) are significant factors in the degradation of HMWM. Interaction between Re and t exp , however, is not always significant (p = 0.73).


  • In Vivo Evaluation of a Physiologic Control System for Rotary Blood Pumps Based on the Left Ventricular Pressure-Volume Loop

    by Joshua Cysyk, Choon-Sik Jhun, Ray Newswanger, Walter Pae, Jenelle Izer, Heidi Flory, John Reibson, William Weiss, Gerson Rosenberg

    Current generation continuous flow assist devices to operate at a fixed speed, which limits preload response and exercise capacity in left ventricular assist device (LVAD) patients. A feedback control system was developed to automatically adjust pump speed based on direct measurements of ventricular loading using a custom cannula tip with an integrated pressure sensor and volume-sensing conductance electrodes. The input to the control system is the integral of the left ventricular (LV) pressure versus conductance loop (PGA) over each cardiac cycle. The feedback control system adjusts pump speed based on the difference between the measured PGA and the desired PGA. The control system and cannula tip were tested in acute ovine studies (n = 5) using the HeartMate II LVAD. The preload response of the control system was evaluated by partially occluding and releasing the inferior vena cava using a vessel loop snare. The cannula tip was integrated onto a custom centrifugal flow LVAD and tested in a 14-day bovine study. The control system adjusted pump support to maintain constant ventricular loading: pump speed increased (decreased) following an increase (decrease) in preload. This study demonstrated in vivo the Starling-like response of an automatic pump control system based on direct measurements of LV loading.


  • Dynamics of Blood Flows in Aortic Stenosis: Mild, Moderate, and Severe

    by Choon-Sik Jhun, Raymond Newswanger, Joshua P. Cysyk, Sailahari Ponnaluri, Bryan Good, Keefe B. Manning, Gerson Rosenberg

    Supraphysiologic high shear stresses created in calcific aortic stenosis (AS) are known to cause hemostatic abnormalities, however, the relationship between the complex blood flows over the severity of AS and hemostatic abnormalities still remains unclear. This study systematically characterized the blood flow in mild, moderate, and severe AS. A series of large eddy simulations (LES) validated by particle image velocimetry were performed on physiologically representative AS models with a peak physiologic flow condition of 18 liter per minute. Time-accurate velocity fields, transvalvular pressure gradient, and laminar viscous—and turbulent (or Reynolds) shear stresses (RSSmax) were evaluated for each degree of severity. The peak velocities of mild, moderate, and severe AS were on the order of 2.0, 4.0, and 8.0 m/s, respectively. Jet velocity in severe AS was highly skewed with extremely high velocity (as high as 8 m/s) and mainly traveled through the posterior aortic wall up to the aortic arch while still carrying a relatively high velocity, that is, >4 m/s. The mean laminar viscous wall shear stresses (WSS) for mild, moderate, and severe AS were on the order of 40, 100, and 180 Pa, respectively. The RSSmax were on the order of 260, 490, and 2,500 Pa for mild, moderate, and severe AS, respectively. This study may provide a link between altered flows in AS and hemostatic abnormalities such as acquired von Willebrand syndrome and hemolysis, thus, help diagnosing and timing of the treatment.


  • Stress and Exposure Time on von Willebrand Factor Degradation

    by Choon‐Sik Jhun, Christopher Siedlecki, Lichong Xu, Branka Lukic, Raymond Newswanger, Eric Yeager, John Reibson, Joshua Cysyk, William Weiss, Gerson Rosenberg

    Despite the prevailing use of the continuous flow left ventricular assist devices (cf‐LVAD), acquired von Willebrand syndrome (AvWS) associated with cf‐LVAD still remains a major complication. As AvWS is known to be dependent on shear stress (τ) and exposure time (texp), this study examined the degradation of high molecular weight multimers (HMWM) of von Willebrand factor (vWF) in terms of τ and texp. Two custom apparatus, i.e., capillary‐tubing‐type degrader (CTD) and Taylor‐Couette‐type degrader (TCD) were developed for short‐term (0.033 sec ≤ texp ≤ 1.05 s) and long‐term (10 s ≤ texp ≤ 10 min) shear exposures of vWF, respectively. Flow conditions indexed by Reynolds number (Re) for CTD were 14 ≤ Re ≤ 288 with corresponding laminar stress level of 52 ≤ ≤ 1042 dyne/cm2. Flow conditions for TCD were 100 ≤ Re ≤ 2500 with corresponding rotor speed of 180 ≤ o ≤ 4000 RPM and laminar stress level of 50 ≤ ≤ 1114 dyne/cm2. Due to transitional and turbulent flows in TCD at Re > 1117, total stress (i.e., = laminar + turbulent) was also calculated using a computational fluid dynamics (CFD) solver, Converge CFD (Converge Science Inc., Madison, WI, USA). Inhibition of ADAMTS13 with different concentration of EDTA (5 mM and 10 mM) was also performed to investigate the mechanism of cleavage in terms of mechanical and enzymatic aspects. Degradation of HMWM with CTD was negligible at all given testing conditions. Although no degradation of HMWM was observed with TCD at Re < 1117 ( = 1012 dyne/cm2), increase in degradation of HMWM was observed beyond Re of 1117 for all given exposure times. At Re ~ 2500 ( = 3070 dyne/cm2) with texp = 60 s, a severe degradation of HMWM (90.7 ± 3.8%, abnormal) was observed, and almost complete degradation of HMWM (96.1 ± 1.9%, abnormal) was observed with texp = 600 s. The inhibition studies with 5 mM EDTA at Re ~ 2500 showed that loss of HMWM was negligible (texp = 10 min (39.5 ± 22.3%, borderline‐abnormal). With 10 mM EDTA, no degradation of HMWM was observed (11.1 ± 4.4%, normal) even for texp = 10 min. This study investigated the effect of shear stress and exposure time on the HMWM of vWF in laminar and turbulent flows. The inhibition study by EDTA confirms that degradation of HMWM is initiated by shear‐induced unfolding followed by enzymatic cleavage at given conditions. Determination of magnitude of each mechanism needs further investigation. It is also important to note that the degradation of vWF is highly dependent on turbulence regardless of the time exposed within our testing conditions.