EPEnrico De Pieri

Enrico De Pieri

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Enrico De Pieri has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Extending Musculoskeletal Modelling Validation Beyond Gait: Knee Loading and Kinematics During Daily Activities

    by Enrico De Pieri, Sara C. Sarabadani Tafreshi, Sabrina Hörmann, Morten E. Lund, Philipp Damm, Pascal Schütz, William R. Taylor, Marc Bandi, Jörn Seebeck

    Musculoskeletal (MSK) modelling enables non-invasive estimation of internal body loads, which could inform the design of novel orthopedic implants and guide personalized treatment strategies. Extensive validation is a pre-requisite for the translation of MSK-modelling frameworks into clinical applications. This study validates predicted knee loads and local kinematics across multiple activities of daily living (ADLs) using motion-capture data from 184 activity cycles collected in six subjects performing five ADLs from the CAMS-Knee datasets. Personalized models incorporated subject-specific anthropometric, radiographic, and implantation data, along with a 6-DOF elastic-foundation contact model between implant components and a surgically balanced ligament model derived from cadaveric testing. Across activities, predicted knee contact force magnitudes showed good agreement with instrumented implant measurements (RMSE 0.46 BW; R² = 0.81). The highest accuracy was found during level walking, whereas stair descent exhibited the largest discrepancies. Predicted implant kinematics showed qualitatively similar trends to fluoroscopic measurements across all ADLs, although with varying levels of accuracy across different degrees of freedom. EMG comparisons revealed broadly consistent activation timing between model predictions and experimental data, although gastrocnemius activation was poorly estimated during stair descent and downhill walking. By validating MSK model predictions across the complete range of activities available in the CAMS- Knee datasets, this study extends validation beyond previously analysed gait or bending tasks and reveals activity-specific discrepancies that reflect current limitations in modelling assumptions and would remain undetected in single-activity analyses. These findings provide a robust basis for future refinement of MSK models and support their development toward clinically meaningful applications.

  • Open Access

    Effects of Physiological Loading from Patient-Derived Activities of Daily Living on the Wear of Metal-on-Polymer Total Hip Replacements

    by Benjamin A. Clegg, Samuel Perry, Enrico De Pieri, Anthony C. Redmond, Stephen J. Ferguson, David E. Lunn, Richard M. Hall, Michael G. Bryant, Nazanin Emami, Andrew R. Beadling

    The current pre-clinical testing standards for total hip replacements (THRs), ISO standards, use simplified loading waveforms that do not fully replicate real-world biomechanics. These standards provide a benchmark of data that may not accurately predict in vivo wear, necessitating the evaluation of physiologically relevant loading conditions. Previous studies have incorporated activities of daily living (ADLs) such as walking, jogging and stair negotiation into wear simulations. However, these studies primarily used simplified adaptations that increased axial forces and applied accelerated sinusoidal waveforms, rather than fully replicating the complex kinematics experienced by THR patients. To address this gap, this study applied patient-derived ADL profiles—jogging and stair negotiation—using a three-station hip simulator, obtained through 3D motion analysis of total hip arthroplasty patients, processed via a musculoskeletal multibody modelling approach to derive realistic hip contact forces (HCFs). The results indicate that jogging significantly increased wear rates compared to the ISO walking gait waveform, with wear increasing from 15.24 ± 0.55 to 28.68 ± 0.87 mm3/Mc. Additionally, wear was highly sensitive to changes in lubricant protein concentration, with an increase from 17 g/L to 30 g/L reducing wear by over 60%. Contrary to predictive models, stair descent resulted in higher volumetric wear (8.62 ± 0.43 mm3/0.5 Mc) compared to stair ascent (4.15 ± 0.31 mm3/0.5 Mc), despite both profiles having similar peak torques. These findings underscore the limitations of current ISO standards in replicating physiologically relevant wear patterns. The application of patient-specific loading profiles highlights the need to integrate ADLs into pre-clinical testing protocols, ensuring a more accurate assessment of implant performance and longevity.


  • Biomechanical evaluation of physical examination tests for rotator cuff tears: a computer simulation study

    by Johanna Menze, J. Tomás Rojas, Matthias A. Zumstein, Stephen J. Ferguson, Enrico De Pieri, Kate Gerber


  • Open Access

    Effect of femoral derotational osteotomy in patients with idiopathic increased femoral anteversion on joint loading and muscular demands

    by Nathalie Alexander, Johannes Cip, Reinald Gh Brunner, Enrico De Pieri

    Purpose: This study aimed to analyse the effect of the femoral derotational osteotomy (FDRO) on joint kinematics, kinetics, joint and muscle forces, and muscle moments in patients with idiopathic increased femoral anteversion compared with typically developing children (TDC). Methods: In this retrospective study, 17 patients (25 limbs, 13.2 ± 2.2 years, femoral anteversion = 49.0° ± 7.1°) were compared to nine TDC (9 limbs, 12.0 ± 3.0 years, femoral anteversion = 18.7° ± 4.1°). Gait analysis was performed 8.5 ± 7.2 months pre-surgery and 17.3 ± 5.5 months post-surgery. Joint angles, moments and forces as well as muscle forces and muscle contributions to joint moments were analysed using statistical parametric mapping. Results: Significant improvements in kinematics (hip rotation, foot progression, knee and hip flexion) were observed pre- to post-FDRO. Joint forces remained unaltered after surgery and did not differ from TDC. Gluteus minimus and deep external rotators muscle forces decreased in mid-stance, while adductor muscle forces increased during stance post-op compared to pre-op. Due to an improved knee extension postoperatively, the rectus femoris muscle force decreased to normal values during mid- and terminal stance. Postoperatively, only the deep external rotator muscle forces differed from TDC. Conclusions: This study showed that FDRO can restore muscle forces and muscle contributions to joint moments in addition to normal gait kinematics, while joint contact forces remain within normative ranges. This knowledge might also apply to other conditions in which pathological femoral anteversion is present.


  • Open Access

    Load-induced blood marker kinetics in patients with medial knee compartment osteoarthritis are associated with accumulated load and patient reported outcome measures

    by Annegret Mündermann, Corina Nüesch, Simon Herger, Anna-Maria Liphardt, Frédérique Chammartin, Enrico De Pieri, Christian Egloff

    Background This study aimed to quantify the mechanoresponse of 10 blood marker candidates for joint metabolism to a walking stress test in patients with knee osteoarthritis and to determine the association among marker kinetics and with accumulated load and patient reported outcomes. Methods 24 patients with knee osteoarthritis completed questionnaires, and a 30-minute walking stress test with six blood serum samples and gait analysis. Concentrations of cartilage oligomeric matrix protein (COMP), matrix metalloproteinases (MMP)-1, -3, and -9, epitope resulting from cleavage of type II collagen by collagenases (C2C), type II procollagen (CPII), interleukin (IL)-6, proteoglycan (PRG)-4, A disintegrin and metalloproteinase with thrombospondin motifs (ADAMTS)-4, and resistin were determined by enzyme-linked immunosorbent assays, Joint load (moments and compartmental forces) was estimated using musculoskeletal modeling using gait analysis data. Results COMP and MMP-3 showed an immediate increase after the walking stress followed by a decrease. MMP-9 and resistin showed a delayed decrease below pre-stress levels. ∆COMP correlated with ∆MMP-3 for most time points. ∆MMP-9 correlated with ∆resistin for most time points. The load-induced increase in blood marker levels correlated among blood markers and time points. C2C and resistin correlated positively and C2C/CPII and MMP2 correlated negatively with load during gait. Immediate relative ∆CPII and ∆MMP1 and delayed relative ∆COMP, ∆IL6, ∆C2C, ∆CPII, ∆MMP1 and ∆MMP3 correlated with the load accumulated during the walking stress. Baseline C2C levels correlated with Knee Osteoarthritis Outcome Score (KOOS) subscales and load-induced changes in MMP-3 with KOOS and Short Form 36 quality of life subscores (P<0.05). Conclusions The distinct and differentiated physiological response to the walking stress depends on accumulated load and appears relevant for patient reported osteoarthritis outcome and quality of life and warrants further investigation in the context of disease progression. ClinicalTrials.gov registration: NCT02622204


  • Open Access

    The Non-Affected Muscle Volume Compensates for the Partial Loss of Strength after Injection of Botulinum Toxin A

    by Reinald Brunner, Enrico De Pieri, Christian Wyss, Claudia Weidensteiner, Katrin Bracht-Schweizer, Jacqueline Romkes, Meritxell Garcia, Norine Ma, Erich Rutz

    Local botulinum toxin (BTX-A, Botox®) injection in overactive muscles is a standard treatment in patients with cerebral palsy. The effect is markedly reduced in children above the age of 6 to 7. One possible reason for this is the muscle volume affected by the drug. Nine patients (aged 11.5; 8.7–14.5 years) with cerebral palsy GMFCS I were treated with BTX-A for equinus gait at the gastrocnemii and soleus muscles. BTX-A was administered at one or two injection sites per muscle belly and with a maximum of 50 U per injection site. Physical examination, instrumented gait analysis, and musculoskeletal modelling were used to assess standard muscle parameters, kinematics, and kinetics during gait. Magnetic resonance imaging (MRI) was used to detect the affected muscle volume. All the measurements were carried out pre-, 6 weeks post-, and 12 weeks post-BTX-A. Between 9 and 15% of the muscle volume was affected by BTX-A. There was no effect on gait kinematics and kinetics after BTX-A injection, indicating that the overall kinetic demand placed on the plantar flexor muscles remained unchanged. BTX-A is an effective drug for inducing muscle weakness. However, in our patient cohort, the volume of the affected muscle section was limited, and the remaining non-affected parts were able to compensate for the weakened part of the muscle by taking over the kinetic demands associated with gait, thus not enabling a net functional effect in older children. We recommend distributing the drug over the whole muscle belly through multiple injection sites.


  • Open Access

    Load-induced blood marker kinetics in patients with medial knee compartment osteoarthritis are associated with accumulated load and patient reported outcome measures

    by Annegret Mündermann, Corina Nüesch, Simon Herger, Anna-Maria Liphardt, Frédérique Chammartin, Enrico De Pieri, Christian Egloff

    Background: This study aimed to quantify the mechanoresponse of 10 blood marker candidates for joint metabolism to a walking stress test in patients with knee osteoarthritis and to determine the association among marker kinetics and with accumulated load and patient reported outcomes. Methods: 24 patients with knee osteoarthritis completed questionnaires, and a walking stress test with six blood serum samples and gait analysis. Concentrations of cartilage oligomeric matrix protein (COMP), matrix metalloproteinases (MMP)-1, -3, and -9, epitope resulting from cleavage of type II collagen by collagenases (C2C), type II procollagen (CPII), interleukin (IL)-6, proteoglycan (PRG)-4, A disintegrin and metalloproteinase with thrombospondin motifs (ADAMTS)-4, and resistin were determined by enzyme-linked immunosorbent assays, Joint load (moments and compartmental forces) was estimated using musculoskeletal modeling using gait analysis data. Results: COMP and MMP-3 showed an immediate increase after the walking stress followed by a decrease. MMP-9 and resistin showed a delayed decrease below pre-stress levels. ∆COMP correlated with ∆MMP-3 for most time points. ∆MMP-9 correlated with ∆resistin for most time points. The load-induced increase in blood marker levels correlated among blood markers and time points. C2C and resistin correlated positively and C2C/CPII and MMP2 correlated negatively with load during gait. Immediate relative ∆CPII and ∆MMP1 and delayed relative ∆COMP, ∆IL6, ∆C2C, ∆CPII, ∆MMP1 and ∆MMP3 correlated with the load accumulated during the walking stress. Baseline C2C levels correlated with Knee Osteoarthritis Outcome Score (KOOS) subscales and load-induced changes in MMP-3 with KOOS and Short Form 36 quality of life subscores (P<0.05). Conclusions: The distinct and differentiated physiological response to the walking stress depends on accumulated load and appears relevant for patient reported osteoarthritis outcome and quality of life and warrants further investigation in the context of disease progression. ClinicalTrials.gov registration: NCT02622204


  • Open Access

    High tibial osteotomy effectively redistributes compressive knee loads during walking

    by Enrico De Pieri, Corina Nüesch, Geert Pagenstert, Elke Viehweger, Christian Egloff, Annegret Mündermann

    The objectives of this study were to estimate pre‐ and postoperative lower limb kinematics and kinetics and knee intra‐articular forces during gait using musculoskeletal modeling in a cohort of patients with knee osteoarthritis (OA) undergoing high tibial osteotomy (HTO), compare these to controls, and determine correlations between changes in these parameters and Knee Injury and Osteoarthritis Outcome Score (KOOS) subscores after HTO. Sixteen patients with isolated, symptomatic medial compartment knee OA completed pre‐ and postoperative gait analysis (mean follow‐up time: 8.6 months). Sixteen age‐ and sex‐matched asymptomatic volunteers participated as controls. Musculoskeletal modeling was used to evaluate lower limb joint moments and knee contact forces during gait. While HTO had limited influence on sagittal plane kinematics and moments, significant changes in the load distribution at the knee after HTO were observed with a lower postoperative compressive load on the medial compartment during midstance and a higher compressive load on the lateral compartment during early and late stance. Moreover, the lateral shear force in midstance was significantly lower after HTO. Changes in the external knee adduction moment (KAM) did not always coincide with reductions in the knee compressive force in the medial compartment. Biomechanical changes did not correlate with improvements in KOOS subscores. Hence, HTO effectively unloaded the medial compartment by redistributing part of the overall compressive force to the lateral compartment during gait with limited influence on gait function. The KAM may not adequately describe compartmental load magnitude or changes induced by interventions at the compartment level. Clinical trial registration: ClinicalTrials. gov Identifier—NCT02622204. Clinical significance: This study provides important evidence for changes in joint level loads after corrective osteotomy as joint preserving surgery and emphasizes the need for additional biomechanical outcomes of such interventions.


  • Open Access

    Increased Femoral Anteversion Does Not Lead to Increased Joint Forces During Gait in a Cohort of Adolescent Patients

    by Nathalie Alexander, Reinald Brunner, Johannes Cip, Elke Viehweger, Enrico De Pieri

    Orthopedic complications were previously reported for patients with increased femoral anteversion. A more comprehensive analysis of the influence of increased femoral anteversion on joint loading in these patients is required to better understand the pathology and its clinical management. Therefore, the aim was to investigate lower-limb kinematics, joint moments and forces during gait in adolescent patients with increased, isolated femoral anteversion compared to typically developing controls. Secondly, relationships between the joint loads experienced by the patients and different morphological and kinematic features were investigated. Patients with increased femoral anteversion (n = 42, 12.8 ± 1.9 years, femoral anteversion: 39.6 ± 6.9°) were compared to typically developing controls (n = 9, 12.0 ± 3.0 years, femoral anteversion: 18.7 ± 4.1°). Hip and knee joint kinematics and kinetics were calculated using subject-specific musculoskeletal models. Differences between patients and controls in the investigated outcome variables (joint kinematics, moments, and forces) were evaluated through statistical parametric mapping with Hotelling T2 and t-tests (α = 0.05). Canonical correlation analyses (CCAs) and regression analyses were used to evaluate within the patients’ cohort the effect of different morphological and kinematic predictors on the outcome variables. Predicted compressive proximo-distal loads in both hip and knee joints were significantly reduced in patients compared to controls. A gait pattern characterized by increased knee flexion during terminal stance (KneeFlextSt) was significantly correlated with hip and knee forces, as well as with the resultant force exerted by the quadriceps on the patella. On the other hand, hip internal rotation and in-toeing, did not affect the loads in the joints. Based on the finding of the CCAs and linear regression analyses, patients were further divided into two subgroups based KneeFlextSt. Patients with excessive KneeFlextSt presented a significantly higher femoral anteversion than those with normal KneeFlextSt. Patients with excessive KneeFlextSt presented significantly larger quadriceps forces on the patella and a larger posteriorly-oriented shear force at the knee, compared to patients with normal KneeFlextSt, but both patients’ subgroups presented only limited differences in terms of joint loading compared to controls. This study showed that an altered femoral morphology does not necessarily lead to an increased risk of joint overloading, but instead patient-specific kinematics should be considered.