DLDavid E. Lunn

David E. Lunn

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David E. Lunn has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    End-Effector Robotic Rehabilitation After Spinal Cord Injury: A Systematic Review of Devices, Operational Characteristics Used, Outcome Measures, and Rehabilitation Effectiveness

    by Michael Baldock, Silvia Caggiari, Antonio Capozio, David E. Lunn, Frances Gawne, Ioannis Delis, Sarah L. Astill

    Background: End-effector robotic devices are increasingly used in rehabilitation to retrain neural pathways through repetitive, task-specific exercise. However, the influence of movement kinematic variables remains unclear. This systematic review aimed to; (i) identify end-effector robotic systems used in upper- and lower-limb spinal cord injury rehabilitation, (ii) describe their technical specifications and operational use, and (iii) explore associations between device use characteristics and study outcomes. Methods: A systematic review of five databases was conducted from inception to June 2026. Results: Fifteen studies, ten lower-limb and five upper-limb, met the inclusion criteria. These covered five commercially available lower-limb devices and three upper-limb devices. Most lower-limb studies demonstrated moderate-to-large improvements in balance, ambulation (WISCI-II), walking endurance (6mWT), and independence (SCIM-III). End-effector training produced comparable outcomes to both conventional therapy and exoskeleton-based rehabilitation in controlled comparisons. Upper-limb studies showed substantial heterogeneity in outcome selection, reflecting diverse rehabilitation goals. Conclusions: WISCI-II and 10MWT were the most used lower-limb functional assessments, with SCIM-III used to assess independence for both upper- and lower-limb motor impairments. Reporting of kinematic settings are often limited and concentrated at study onset, limiting assessment of their contribution to outcomes. Reporting the progression of session-level metrics is needed to better understand how time-varying kinematics affect intervention effectiveness.

  • Open Access

    Motion capture dataset of 137 post-operative total hip replacement patients performing activities of daily living

    by David E. Lunn, Enrico De Pieri, Graham J. Chapman, Morten E. Lund, Stephen J. Ferguson, Anthony C. Redmond

    Three-dimensional motion capture is a powerful tool in clinical and engineering applications, but it can be time consuming, expensive, and difficult to access patient populations. Here, we present an open-access dataset comprising 3D motion capture and ground reaction force data from 137 post-operative total hip replacement patients performing eight activities of daily living (ADLs): normal walking, fast walking, stair ascent, stair descent, sit-to-stand, stand-to-sit, lunge, and squat. Data were collected using a 10-camera Vicon system and two AMTI force plates, and are provided in C3D and txt file format, compatible with inverse dynamic analysis platforms (e.g Visual 3D, MOKKA) and musculoskeletal modelling platforms (e.g. OpenSim, AnyBody). Each file includes synchronised marker trajectories, analog force data, and participant metadata (e.g. age, sex, BMI, operated limb, time since surgery). This dataset offers a unique opportunity to study functional biomechanics across a range of ADLs, enabling applications in musculoskeletal modelling, rehabilitation assessment, and the development of machine learning algorithms.


  • Open Access

    Achilles’ tendon stretch during walking in hinged controlled ankle motion boots

    by Mason L. Stolycia, David E. Lunn, Richard A. Wilkins, Josh Walker

  • Open Access

    Effects of Physiological Loading from Patient-Derived Activities of Daily Living on the Wear of Metal-on-Polymer Total Hip Replacements

    by Benjamin A. Clegg, Samuel Perry, Enrico De Pieri, Anthony C. Redmond, Stephen J. Ferguson, David E. Lunn, Richard M. Hall, Michael G. Bryant, Nazanin Emami, Andrew R. Beadling

    The current pre-clinical testing standards for total hip replacements (THRs), ISO standards, use simplified loading waveforms that do not fully replicate real-world biomechanics. These standards provide a benchmark of data that may not accurately predict in vivo wear, necessitating the evaluation of physiologically relevant loading conditions. Previous studies have incorporated activities of daily living (ADLs) such as walking, jogging and stair negotiation into wear simulations. However, these studies primarily used simplified adaptations that increased axial forces and applied accelerated sinusoidal waveforms, rather than fully replicating the complex kinematics experienced by THR patients. To address this gap, this study applied patient-derived ADL profiles—jogging and stair negotiation—using a three-station hip simulator, obtained through 3D motion analysis of total hip arthroplasty patients, processed via a musculoskeletal multibody modelling approach to derive realistic hip contact forces (HCFs). The results indicate that jogging significantly increased wear rates compared to the ISO walking gait waveform, with wear increasing from 15.24 ± 0.55 to 28.68 ± 0.87 mm3/Mc. Additionally, wear was highly sensitive to changes in lubricant protein concentration, with an increase from 17 g/L to 30 g/L reducing wear by over 60%. Contrary to predictive models, stair descent resulted in higher volumetric wear (8.62 ± 0.43 mm3/0.5 Mc) compared to stair ascent (4.15 ± 0.31 mm3/0.5 Mc), despite both profiles having similar peak torques. These findings underscore the limitations of current ISO standards in replicating physiologically relevant wear patterns. The application of patient-specific loading profiles highlights the need to integrate ADLs into pre-clinical testing protocols, ensuring a more accurate assessment of implant performance and longevity.


  • Open Access

    Concurrent validity of Theia3D markerless motion capture for detecting sagittal kinematic differences between gait speeds

    by Josh Walker, Aaron Thomas, David E. Lunn, Gareth Nicholson, Catherine B. Tucker

    We do not yet understand the concurrent validity of markerless motion capture (MMC) to measure kinematic differences between multiple gait speeds. This study determined the capacity of Theia3D (Theia Markerless Inc.) MMC to detect sagittal-plane kinematic responses to different gait speeds during walking (3 and 5 km/h) and running (10 and 12 km/h). Fourteen participants ambulated on a motorised treadmill, while marker-based motion capture, through optoelectronic cameras (Oqus 7+, Qualisys AB), and MMC, through videos (Miqus, Qualisys AB) were synchronously collected. Sagittal-plane changes in pelvis, hip, knee, and ankle kinematics were compared. Mostly excellent waveform similarity was found for joint kinematic changes (coefficient of multiple determination [CMD] ≥ 0.87), but pelvic tilt was less similar (CMD ≤0.48). Agreement between outcome measures (joint minima and maxima, range of motion) was mostly good-to-excellent (intraclass correlation coefficient [ICC] = 0.475-0.950) with standard error of measurement values of less than 1°. Pelvis kinematics showed lower agreement between systems (ICC = 0.032-0.776). In this study, Theia3D detected changes in hip, knee, and ankle sagittal-plane joint kinematics between speeds with a similar accuracy to the marker-based approach. Therefore, Theia3D is appropriate for use if interested in lower-limb sagittal joint kinematics, but not pelvic tilt.


  • Open Access

    Hip contact force pathways in total hip replacement differ between patients and activities of daily living

    by David E. Lunn, Anthony C. Redmond, Graham J. Chapman, Morten E. Lund, Stephen J. Ferguson, Enrico De Pieri


  • Open Access

    Biomechanical effectiveness of controlled ankle motion boots: A systematic review and narrative synthesis

    by Mason L. Stolycia, David E. Lunn, Will Stanier, Josh Walker, Richard A. Wilkins

    Introduction: Controlled ankle motion (CAM) boots are a below‐knee orthotic device prescribed for the management of foot and ankle injuries to reduce ankle range of motion (RoM) and offload the foot and ankle whilst allowing continued ambulation during recovery. There is a lack of clarity within the current literature surrounding the biomechanical understanding and effectiveness of CAM boots.Aims: To summarise the biomechanical effects of CAM boot wear as an orthotic for restricting ankle RoM and offloading the foot.Methods: A systematic literature review was conducted in accordance with the PRISMA 2020 guidelines. All papers were independently screened by two authors for inclusion. Methodological quality was appraised using Joanna Briggs Critical Appraisal checklists. A narrative synthesis of all eligible papers was produced.Results: Thirteen studies involving 197 participants (113 male and 84 female) were included. All studies were quasi‐randomised and employed a within‐study design, of which 12 studies included a control group and a range of CAM boots were investigated. CAM boots can be seen to restrict ankle RoM, however, neighboring joints such as the knee and hip do have kinetic and kinematic compensatory alterations. Plantar pressure of the forefoot is effectively redistributed to the hindfoot by CAM boots.Conclusion: The compensatory mechanisms at the hip and knee joint during CAM boot wear could explain the secondary site pain often reported in patients, specifically at the ipsilateral knee and contralateral hip. Although CAM boots can be used to restrict ankle motion, this review has highlighted a lack of in‐boot kinematic analyses during CAM boot use, where tracking markers are placed on the anatomical structure rather than on the boot, or through video fluoroscopy, urging the need for a more robust methodological approach to achieve this. There is a need for studies to assess the biomechanical alterations caused by CAM boots in populations living with foot and ankle pathologies. Future research, adopting a longitudinal study design, is required to fully understand the effectiveness of CAM boots for rehabilitation.


  • Open Access

    Dynamic Acetabular Cup Orientation during Gait: A Study of Fast- and Slow-Walking Total Hip Replacement Patients

    by Ksenija Vasiljeva, David Lunn, Graham Chapman, Anthony Redmond, Lin Wang, Jonathan Thompson, Sophie Williams, Ruth Wilcox, Alison Jones

    The dynamic orientation of total hip replacement acetabular cups during walking may vary substantially from their assumed position at surgical implantation and may vary between individuals. The scale of this effect is of interest for both pre-clinical device testing and for pre-operative surgical planning. This work aimed to evaluate (1) patient variation in dynamic cup orientation; (2) whether walking speed was a candidate proxy measure for the dynamic cup orientation; and (3) the relationships between dynamic cup orientation angles and planar pelvic angles. Pelvic movement data for patients with fast (20 patients) and slow (19 patients) self-selected walking speeds were used to calculate acetabular cup inclination and version angles through gait. For aim 1, the range and extremes of acetabular cup orientation angles were analysed for all patients. A large patient-to-patient variation was found in the ranges of both inclination angle (1° to 11°) and version angle (4° to 18°). The version angle was typically retroverted in comparison to the implantation position (greatest deviation 27°). This orientation is substantially different to the static, 0° version, simplifying assumptions in pre-clinical ‘edge loading’ testing. For aim 2, the cup orientation angles were compared between the fast- and slow-walking groups using statistical parametric mapping. The only significant differences observed were for cup version angle, during ~12% of the gait cycle before toe-off (p < 0.05). Therefore, self-selected walking speed, in isolation, is not a sufficient proxy measure for dynamic acetabular orientation. For aim 3, correlations were recorded between the acetabular cup orientation angles and the planar pelvic angles. The cup inclination angle during gait was strongly correlated (Spearman’s coefficient −1) with pelvic obliquity alone, indicating that simple planar assessment could be used to anticipate inclination angle range. The cup version angle was correlated with both pelvic rotation and tilt (Spearman’s coefficient 0.8–1), indicating that cup version cannot be predicted directly from any single pelvic movement. This complexity, along with the interaction between inclination angle and range of version angle, supports the use of computational tools to aid clinical understanding.


  • Open Access

    Functional outcomes differ between direct lateral and posterior surgical approaches in total hip arthroplasty during higher demanding activities of daily living

    by Daniel Tsf Tadross, Graham J Chapman, Anthony C Redmond, David Macdonald, Martin Stone, David E Lunn

    Background: This study investigated the effect of posterior and direct lateral (modified Hardinge) approach total hip arthroplasty on post-operative hip function compared to healthy, control participants. This study aimed to use a combination of motion analysis, strength measurements and imaging to investigate the effect of surgical approach on post-operative hip function in posterior approach and direct lateral approach cases.Methods: Twenty-eight total hip arthroplasty patients (15 direct lateral approach; 13 posterior approach) and 11 control participants underwent motion capture analysis at two walking speeds (normal and fast walking) and whilst standing from a seated position; hip joint strength and patient reported outcomes were also obtained. Muscle cross-sectional area was measured in a sub-set (N=5) using a novel magnetic resonance imaging sequence incorporating encoding for metal artefact correction.Results: The posterior approach group tended not to achieve full hip extension post-surgically, whereas the direct lateral approach patients tended to extend the hip during the fast walk, similar to control participants. The posterior approach group were weaker in all muscle groups excluding hip abductors, compared to the direct lateral approach patients and control group. In both surgical groups the muscle cross sectional area was reduced in all muscles disrupted during surgery, compared to the contralateral limb. Both surgical groups’ perceived hip function and physical health to be superior compared to the control group.Conclusions: Our findings suggest during sit to stand and fast walking the posterior approach group were functionally poorer and demonstrated weaker hip strength compared to the direct lateral approach group. Furthermore, surgical muscle disruption in our subset of patients is still apparent up to five years post-surgery, as reflected by reduced muscle cross sectional area.