FFFredrik Eikeland Fossan

Fredrik Eikeland Fossan

*This is an algorithmically generated author record based on publicly available information.

Fredrik Eikeland Fossan has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Relevance of autoregulation in the diagnosis of coronary artery disease with CT-FFR

    by Fredrik E. Fossan, Anders T. Bråten, Alessia Lucca, Lucas O. Müller, Arve Jørgensen, Rune Wiseth, Leif R. Hellevik

    We present a novel autoregulation-aware model of microvascular resistance for CT-FFR computations. The model improves prediction accuracy compared with conventional approaches for modeling the hyperemic state. Integration of CCTA-derived anatomy and invasive pressures reveals sex- and territory-dependent microvascular responses to adenosine, highlighting the diagnostic role of combined assessment of epicardial and microvascular disease.

  • Open Access

    Uncertainty Quantification and Sensitivity Analysis for Non‐invasive Model‐Based Instantaneous Wave‐Free Ratio Prediction

    by Caterina Dalmaso, Fredrik Eikeland Fossan, Anders Tjellaug Bråten, Lucas Omar Müller

    The main objectives of this work are to validate a 1D‐0D unsteady solver with a distributed stenosis model for the patient‐specific estimation of resting haemodynamic indices and to assess the sensitivity of instantaneous wave‐free ratio (iFR) predictions to uncertainties in input parameters. We considered 52 patients with stable coronary artery disease, for which 81 invasive iFR measurements were available. We validated the performance of our solver compared to 3D steady‐state and transient results and invasive measurements. Next, we used a polynomial chaos approach to characterise the uncertainty in iFR predictions based on the inputs associated with boundary conditions (coronary flow, compliance and aortic/left ventricular pressures) and vascular geometry (radius). Agreement between iFR and the ratio between cardiac cycle averaged distal and aortic pressure waveforms (resting ) obtained through 1D‐0D and 3D models was satisfactory, with a bias of 0.0–0.005 (±0.016–0.026). The sensitivity analysis showed that iFR estimation is mostly affected by uncertainties in vascular geometry and coronary flow (steady‐state parameters). In particular, our 1D‐0D method overestimates invasive iFR measurements, with a bias of −0.036 (±0.101), indicating that better flow estimates could significantly improve our modelling pipeline. Conversely, we showed that standard pressure waveforms could be used for simulations, since the impact of uncertainties related to inlet‐pressure waveforms on iFR prediction is negligible. Furthermore, while compliance is the most relevant transient parameter, its effect on iFR estimates is negligible compared to that of vascular geometry and flow. Finally, we observed a strong correlation between iFR and resting , suggesting that steady‐state simulations could replace unsteady simulations for iFR prediction.


  • Open Access

    Machine learning augmented reduced-order models for FFR-prediction

    by Fredrik E. Fossan, Lucas O. Müller, Jacob Sturdy, Anders T. Bråten, Arve Jørgensen, Rune Wiseth, Leif R. Hellevik


  • Open Access

    Impact of baseline coronary flow and its distribution on fractional flow reserve prediction

    by Lucas O. Müller, Fredrik E. Fossan, Anders T. Bråten, Arve Jørgensen, Rune Wiseth, Leif R. Hellevik

    Model‐based prediction of fractional flow reserve (FFR) in the context of stable coronary artery disease (CAD) diagnosis requires a number of modelling assumptions. One of these assumptions is the definition of a baseline coronary flow, ie, total coronary flow at rest prior to the administration of drugs needed to perform invasive measurements. Here we explore the impact of several methods available in the literature to estimate and distribute baseline coronary flow on FFR predictions obtained with a reduced‐order model. We consider 63 patients with suspected stable CAD, for a total of 105 invasive FFR measurements. First, we improve a reduced‐order model with respect to previous results and validate its performance versus results obtained with a 3D model. Next, we assess the impact of a wide range of methods to impose and distribute baseline coronary flow on FFR prediction, which proved to have a significant impact on diagnostic performance. However, none of the proposed methods resulted in a significant improvement of prediction error standard deviation. Finally, we show that intrinsic uncertainties related to stenosis geometry and the effect of hyperemic inducing drugs have to be addressed in order to improve FFR prediction accuracy.


  • Open Access

    Optimization of topological complexity for one-dimensional arterial blood flow models

    by Fredrik E. Fossan, Jorge Mariscal-Harana, Jordi Alastruey, Leif R. Hellevik

    As computational models of the cardiovascular system are applied in modern personalized medicine, maximizing certainty of model input becomes crucial. A model with a high number of arterial segments results in a more realistic description of the system, but also requires a high number of parameters with associated uncertainties. In this paper, we present a method to optimize/reduce the number of arterial segments included in one-dimensional blood flow models, while preserving key features of flow and pressure waveforms. We quantify the preservation of key flow features for the optimal network with respect to the baseline networks (a 96-artery and a patient-specific coronary network) by various metrics and quantities like average relative error, pulse pressure and augmentation pressure. Furthermore, various physiological and pathological states are considered. For the aortic root and larger systemic artery pressure waveforms a network with minimal description of lower and upper limb arteries and no cerebral arteries, sufficiently captures important features such as pressure augmentation and pulse pressure. Discrepancies in carotid and middle cerebral artery flow waveforms that are introduced by describing the arterial system in a minimalistic manner are small compared with errors related to uncertainties in blood flow measurements obtained by ultrasound.


  • Uncertainty Quantification and Sensitivity Analysis for Computational FFR Estimation in Stable Coronary Artery Disease

    by Fredrik E. Fossan, Jacob Sturdy, Lucas O. Müller, Andreas Strand, Anders T. Bråten, Arve Jørgensen, Rune Wiseth, Leif R. Hellevik

    The main objectives of this study are to validate a reduced-order model for the estimation of the fractional flow reserve (FFR) index based on blood flow simulations that incorporate clinical imaging and patient-specific characteristics, and to assess the uncertainty of FFR predictions with respect to input data on a per patient basis.