Anders Tjellaug Bråten
Research Subjects
Anders Tjellaug Bråten has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Fredrik Eikeland Fossan
St. Olavs Hospital
2 shared publications - Lucas Omar Müller
University of Trento
2 shared publications - Rune Wiseth
Clinic of Cardiology, St Olavs University Hospital, Trondheim, Norway (R.W.).
2 shared publications Alessia Lucca
University of Trento
1 shared publicationArve Jørgensen
Department of Circulation and Medical Imaging, Norwegian University of Science and Technology , PO 8900 Torgarden, 7491 Trondheim
1 shared publication- Arve Jørgensen
St. Olavs Hospital
1 shared publication
Latest Publications
- 1 January 2026
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 330 (1) , H157-H169
Relevance of autoregulation in the diagnosis of coronary artery disease with CT-FFR
We present a novel autoregulation-aware model of microvascular resistance for CT-FFR computations. The model improves prediction accuracy compared with conventional approaches for modeling the hyperemic state. Integration of CCTA-derived anatomy and invasive pressures reveals sex- and territory-dependent microvascular responses to adenosine, highlighting the diagnostic role of combined assessment of epicardial and microvascular disease.
- 1 January 2026
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 330 (1) , H157-H169
Relevance of autoregulation in the diagnosis of coronary artery disease with CT-FFR
We present a novel autoregulation-aware model of microvascular resistance for CT-FFR computations. The model improves prediction accuracy compared with conventional approaches for modeling the hyperemic state. Integration of CCTA-derived anatomy and invasive pressures reveals sex- and territory-dependent microvascular responses to adenosine, highlighting the diagnostic role of combined assessment of epicardial and microvascular disease.
- Open Access
- 7 January 2025
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (1) , e3898
Uncertainty Quantification and Sensitivity Analysis for Non‐invasive Model‐Based Instantaneous Wave‐Free Ratio Prediction
The main objectives of this work are to validate a 1D‐0D unsteady solver with a distributed stenosis model for the patient‐specific estimation of resting haemodynamic indices and to assess the sensitivity of instantaneous wave‐free ratio (iFR) predictions to uncertainties in input parameters. We considered 52 patients with stable coronary artery disease, for which 81 invasive iFR measurements were available. We validated the performance of our solver compared to 3D steady‐state and transient results and invasive measurements. Next, we used a polynomial chaos approach to characterise the uncertainty in iFR predictions based on the inputs associated with boundary conditions (coronary flow, compliance and aortic/left ventricular pressures) and vascular geometry (radius). Agreement between iFR and the ratio between cardiac cycle averaged distal and aortic pressure waveforms (resting ) obtained through 1D‐0D and 3D models was satisfactory, with a bias of 0.0–0.005 (±0.016–0.026). The sensitivity analysis showed that iFR estimation is mostly affected by uncertainties in vascular geometry and coronary flow (steady‐state parameters). In particular, our 1D‐0D method overestimates invasive iFR measurements, with a bias of −0.036 (±0.101), indicating that better flow estimates could significantly improve our modelling pipeline. Conversely, we showed that standard pressure waveforms could be used for simulations, since the impact of uncertainties related to inlet‐pressure waveforms on iFR prediction is negligible. Furthermore, while compliance is the most relevant transient parameter, its effect on iFR estimates is negligible compared to that of vascular geometry and flow. Finally, we observed a strong correlation between iFR and resting , suggesting that steady‐state simulations could replace unsteady simulations for iFR prediction.
- 7 January 2025
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 41 (1) , e3898
Open AccessUncertainty Quantification and Sensitivity Analysis for Non‐invasive Model‐Based Instantaneous Wave‐Free Ratio Prediction
The main objectives of this work are to validate a 1D‐0D unsteady solver with a distributed stenosis model for the patient‐specific estimation of resting haemodynamic indices and to assess the sensitivity of instantaneous wave‐free ratio (iFR) predictions to uncertainties in input parameters. We considered 52 patients with stable coronary artery disease, for which 81 invasive iFR measurements were available. We validated the performance of our solver compared to 3D steady‐state and transient results and invasive measurements. Next, we used a polynomial chaos approach to characterise the uncertainty in iFR predictions based on the inputs associated with boundary conditions (coronary flow, compliance and aortic/left ventricular pressures) and vascular geometry (radius). Agreement between iFR and the ratio between cardiac cycle averaged distal and aortic pressure waveforms (resting ) obtained through 1D‐0D and 3D models was satisfactory, with a bias of 0.0–0.005 (±0.016–0.026). The sensitivity analysis showed that iFR estimation is mostly affected by uncertainties in vascular geometry and coronary flow (steady‐state parameters). In particular, our 1D‐0D method overestimates invasive iFR measurements, with a bias of −0.036 (±0.101), indicating that better flow estimates could significantly improve our modelling pipeline. Conversely, we showed that standard pressure waveforms could be used for simulations, since the impact of uncertainties related to inlet‐pressure waveforms on iFR prediction is negligible. Furthermore, while compliance is the most relevant transient parameter, its effect on iFR estimates is negligible compared to that of vascular geometry and flow. Finally, we observed a strong correlation between iFR and resting , suggesting that steady‐state simulations could replace unsteady simulations for iFR prediction.
- Open Access
- 30 September 2024
- Published by BMJ in Open Heart
- Vol. 11 (2) , e002899
Dobutamine stress echocardiography after positive CCTA: diagnostic performance using fractional flow reserve and instantaneous wave-free ratio as reference standards
Aims To assess the diagnostic accuracy of dobutamine stress echocardiography (DSE) in symptomatic patients with a low to intermediate pretest probability of obstructive coronary artery disease (CAD) and a positive coronary CT angiography (CCTA). Methods We prospectively enrolled 104 consecutive patients undergoing coronary angiography for symptoms of stable CAD and a CCTA indicative of obstructive CAD. The diagnostic performance of DSE was evaluated against two intracoronary pressure indices: (a) fractional flow reserve (FFR) with a cut-off of ≤0.80 and (b) instantaneous wave-free ratio (iFR) with a cut-off of ≤0.89, indicating haemodynamically significant stenoses. Results Of 102 patients, 46 (45%) had at least one significant lesion as defined by FFR, as did 37 (36%) as defined by iFR. DSE showed positive results in 33% (34/102) of cases. The discriminative power of DSE for detecting significant CAD was moderate, with areas under the curve of 0.63 (p=0.024) compared with FFR and 0.64 (p=0.025) compared with iFR. The accuracy, sensitivity and specificity of DSE were, respectively, 61%, 43%, and 75% against FFR, and 64%, 46% and 74% against iFR. The diagnostic accuracy of DSE did not differ significantly between FFR and iFR as a reference (p=0.549). Conclusion In patients with positive CCTA, DSE has a moderate ability to identify haemodynamically significant CAD, with low sensitivity and moderate specificity. When assessed against FFR and iFR criteria, its additive diagnostic value is limited in patients with low to intermediate pretest probability of obstructive CAD. Trial registration number NCT03045601.
- 30 September 2024
- Published by BMJ in Open Heart
- Vol. 11 (2) , e002899
Open AccessDobutamine stress echocardiography after positive CCTA: diagnostic performance using fractional flow reserve and instantaneous wave-free ratio as reference standards
Aims To assess the diagnostic accuracy of dobutamine stress echocardiography (DSE) in symptomatic patients with a low to intermediate pretest probability of obstructive coronary artery disease (CAD) and a positive coronary CT angiography (CCTA). Methods We prospectively enrolled 104 consecutive patients undergoing coronary angiography for symptoms of stable CAD and a CCTA indicative of obstructive CAD. The diagnostic performance of DSE was evaluated against two intracoronary pressure indices: (a) fractional flow reserve (FFR) with a cut-off of ≤0.80 and (b) instantaneous wave-free ratio (iFR) with a cut-off of ≤0.89, indicating haemodynamically significant stenoses. Results Of 102 patients, 46 (45%) had at least one significant lesion as defined by FFR, as did 37 (36%) as defined by iFR. DSE showed positive results in 33% (34/102) of cases. The discriminative power of DSE for detecting significant CAD was moderate, with areas under the curve of 0.63 (p=0.024) compared with FFR and 0.64 (p=0.025) compared with iFR. The accuracy, sensitivity and specificity of DSE were, respectively, 61%, 43%, and 75% against FFR, and 64%, 46% and 74% against iFR. The diagnostic accuracy of DSE did not differ significantly between FFR and iFR as a reference (p=0.549). Conclusion In patients with positive CCTA, DSE has a moderate ability to identify haemodynamically significant CAD, with low sensitivity and moderate specificity. When assessed against FFR and iFR criteria, its additive diagnostic value is limited in patients with low to intermediate pretest probability of obstructive CAD. Trial registration number NCT03045601.
- Open Access
- 25 July 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 2 (3) , qyae102
Automated computed tomography-derived fractional flow reserve model for diagnosing haemodynamically significant coronary artery disease: a prospective validation study
This study aims to assess the diagnostic performance of a novel computed tomography-derived fractional flow reserve (CT-FFR) algorithm and to compare its accuracy at three predefined sites: (i) at the location of invasive FFR measurements (CT-FFRatloc), (ii) at selected sites determined by an automated module integrated within the algorithm (CT-FFRauto), and (iii) distally in the vessel (CT-FFRdistal). We prospectively recruited 108 consecutive patients with stable symptoms of coronary artery disease and at least one suspected obstructive lesion on coronary computed tomography angiography (CCTA). CT-FFR was validated against invasive FFR as gold standard using FFR ≤ 0.80 to define myocardial ischaemia. CT-FFRatloc showed good correlation with invasive FFR (r = 0.67) and improved the ability to detect myocardial ischaemia compared with CCTA at both lesion [area under the curve (AUC) 0.83 vs. 0.65, P < 0.001] and patient level (AUC 0.87 vs. 0.74, P = 0.007). CT-FFRauto demonstrated similar diagnostic accuracy to CT-FFRatloc and significantly improved specificity compared with CT-FFRdistal (86% vs. 49%, P < 0.001). High end CT quality improved the diagnostic performance of CT-FFRauto, demonstrating an AUC of 0.92; similarly, the performance was improved in patients with low-to-intermediate coronary artery calcium score with an AUC of 0.88. Implementing an automated module to determine the site of CT-FFR evaluations was feasible, and CT-FFRauto demonstrated comparable diagnostic accuracy to CT-FFRatloc when assessed against invasive FFR. Both CT-FFRatloc and CT-FFRauto improved the diagnostic performance compared with CCTA and improved specificity compared with CT-FFRdistal. High end CT quality and low-to-intermediate calcium burden improved the diagnostic performance of our algorithm. NCT03045601
- 25 July 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 2 (3) , qyae102
Open AccessAutomated computed tomography-derived fractional flow reserve model for diagnosing haemodynamically significant coronary artery disease: a prospective validation study
This study aims to assess the diagnostic performance of a novel computed tomography-derived fractional flow reserve (CT-FFR) algorithm and to compare its accuracy at three predefined sites: (i) at the location of invasive FFR measurements (CT-FFRatloc), (ii) at selected sites determined by an automated module integrated within the algorithm (CT-FFRauto), and (iii) distally in the vessel (CT-FFRdistal). We prospectively recruited 108 consecutive patients with stable symptoms of coronary artery disease and at least one suspected obstructive lesion on coronary computed tomography angiography (CCTA). CT-FFR was validated against invasive FFR as gold standard using FFR ≤ 0.80 to define myocardial ischaemia. CT-FFRatloc showed good correlation with invasive FFR (r = 0.67) and improved the ability to detect myocardial ischaemia compared with CCTA at both lesion [area under the curve (AUC) 0.83 vs. 0.65, P < 0.001] and patient level (AUC 0.87 vs. 0.74, P = 0.007). CT-FFRauto demonstrated similar diagnostic accuracy to CT-FFRatloc and significantly improved specificity compared with CT-FFRdistal (86% vs. 49%, P < 0.001). High end CT quality improved the diagnostic performance of CT-FFRauto, demonstrating an AUC of 0.92; similarly, the performance was improved in patients with low-to-intermediate coronary artery calcium score with an AUC of 0.88. Implementing an automated module to determine the site of CT-FFR evaluations was feasible, and CT-FFRauto demonstrated comparable diagnostic accuracy to CT-FFRatloc when assessed against invasive FFR. Both CT-FFRatloc and CT-FFRauto improved the diagnostic performance compared with CCTA and improved specificity compared with CT-FFRdistal. High end CT quality and low-to-intermediate calcium burden improved the diagnostic performance of our algorithm. NCT03045601