Rosdi Daud
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rosdi Daud has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Arman Shah
Faculty of Technical and Vocational, Universiti Pendidikan Sultan Idris, 35900 Tanjong Malim, Perak, Malaysia
6 shared publications - Mas Ayu Hassan
Universiti Malaysia Pahang Al-Sultan Abdullah
6 shared publications H. Mas Ayu
Universiti Malaysia Pahang
4 shared publicationsA Shah
Faculty of Technical and Vocational,Universiti Pendidikan Sultan Idris, 35900 Kuala Kubu Bharu, Perak, Malaysia
3 shared publicationsArman Shah Abdullah
Universiti Pendidikan Sultan Idris
2 shared publicationsH M Ayu
Faculty of Mechanical and Automotive Engineering Technology, Universiti Malaysia Pahang, 26600 Pekan, Pahang, Malaysia
2 shared publications
Latest Publications
- 31 May 2025
- Published by Springer Nature
- p. 191-199
Optimization of Spot Welding on Vitroperm 500F TL1 (VP 500F) via Taguchi Method
- 31 May 2025
- Published by Springer Nature
- p. 191-199
Optimization of Spot Welding on Vitroperm 500F TL1 (VP 500F) via Taguchi Method
- 3 May 2024
- Published by Springer Nature
- p. 9-17
Estimation of Femur Measurement of Malaysian Adults Using the Artificial Neural Network
- 3 May 2024
- Published by Springer Nature
- p. 9-17
Estimation of Femur Measurement of Malaysian Adults Using the Artificial Neural Network
- 21 September 2023
- Published by Springer Nature
- p. 649-656
Deformation Behaviour of a High Carbon Co–Cr–Mo Medium-Entropy Alloy via Thermal Oxidation
- 21 September 2023
- Published by Springer Nature
- p. 649-656
Deformation Behaviour of a High Carbon Co–Cr–Mo Medium-Entropy Alloy via Thermal Oxidation
- 12 March 2022
- Published by Springer Nature
- p. 29-37
Prediction of Malaysian Talus Bone Morphology Using Artificial Intelligence
- 12 March 2022
- Published by Springer Nature
- p. 29-37
Prediction of Malaysian Talus Bone Morphology Using Artificial Intelligence
- 12 March 2022
- Published by Springer Nature
- p. 39-46
Finite Element Method Study: The Effect of Insertion Torque and Angle on Pedicle Screw Loosening
- 12 March 2022
- Published by Springer Nature
- p. 39-46
Finite Element Method Study: The Effect of Insertion Torque and Angle on Pedicle Screw Loosening
- 6 July 2021
- Published by Springer Nature
- p. 230-240
Investigation on Bending Strength Between Different Designs of Pedicle Screw to Obtain an Optimum Design
- 6 July 2021
- Published by Springer Nature
- p. 230-240
Investigation on Bending Strength Between Different Designs of Pedicle Screw to Obtain an Optimum Design
- Open Access
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1078 (1) , 012025
Effect of thread profile variation on pullout and bending strength of a pedicle screw
Pedicle screw is an important instrument in treatment of spinal degeneration or disease. However, the pedicle screw failure still occurs due to the screw loosening, fracture and pullout. There are few factors that affected the pedicle screw performance as reported by previous research but still lacking study related to the pedicle screw thread profile. Thus, the aim of this research is to investigate the effect of variation of thread pitch on the pullout and bending strength of pedicle screw. The research is carried out by constructing 3D pedicle screw models (model 1-6), importing the models into ANSYS, meshing and post processing analysis. The equivalent or Von-Mises stress used to compare the bending and pullout performance of the pedicle screws. Based on the obtained finite element analysis result, the single thread pedicle screw (model 3) has the optimum performance in bending while the model 4 is the optimum in pullout performance. While, for the dual threaded pedicle screw, the model 6 which has coarse thread pitch at screw tip is better than model 5 (fine thread). Thus, it can be conclude that both the single and dual threaded pedicle screw with coarse thread pitch has lower maximum equivalent stress than fine thread pitch, which is means it has better bending and pullout performance.
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1078 (1) , 012025
Open AccessEffect of thread profile variation on pullout and bending strength of a pedicle screw
Pedicle screw is an important instrument in treatment of spinal degeneration or disease. However, the pedicle screw failure still occurs due to the screw loosening, fracture and pullout. There are few factors that affected the pedicle screw performance as reported by previous research but still lacking study related to the pedicle screw thread profile. Thus, the aim of this research is to investigate the effect of variation of thread pitch on the pullout and bending strength of pedicle screw. The research is carried out by constructing 3D pedicle screw models (model 1-6), importing the models into ANSYS, meshing and post processing analysis. The equivalent or Von-Mises stress used to compare the bending and pullout performance of the pedicle screws. Based on the obtained finite element analysis result, the single thread pedicle screw (model 3) has the optimum performance in bending while the model 4 is the optimum in pullout performance. While, for the dual threaded pedicle screw, the model 6 which has coarse thread pitch at screw tip is better than model 5 (fine thread). Thus, it can be conclude that both the single and dual threaded pedicle screw with coarse thread pitch has lower maximum equivalent stress than fine thread pitch, which is means it has better bending and pullout performance.
- Open Access
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1078 (1) , 012026
Effect of thread profile on bending strength of pedicle screw
Current pedicle screw designs have not achieved strong bending strength due to varying bone density among patients. Osteoporosis further presents complications in screw fixation and instrumentation failure due patients having less dense bones. We conducted this study to investigate the effect of thread profile on the bending strength of pedicle screw. The study also focus on the bending performance comparison between single threaded and dual threaded pedicle screw via finite element method. The finite element analysis (FEA) was apply to investigate the effect of thread design on the bending strength of pedicle screw (dual threaded, double dual threaded and the dual lead dual threaded screw designs) under normal and osteoporotic bone conditions. The FEA results obtained show that the thread profile does influence the bending strength of a pedicle screw in normal and osteoporotic bones. The dual lead dual threaded pedicle screw showed an improvement of 1.88% in its deflection due to bending. While for the osteoporotic condition, the dual lead dual threaded pedicle screw showed an improvement of 32.3% in term of deflection. Thus, this finding have potential in assisting the optimum pedicle screw design in future although further investigation needed to support this finding.
- 1 February 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1078 (1) , 012026
Open AccessEffect of thread profile on bending strength of pedicle screw
Current pedicle screw designs have not achieved strong bending strength due to varying bone density among patients. Osteoporosis further presents complications in screw fixation and instrumentation failure due patients having less dense bones. We conducted this study to investigate the effect of thread profile on the bending strength of pedicle screw. The study also focus on the bending performance comparison between single threaded and dual threaded pedicle screw via finite element method. The finite element analysis (FEA) was apply to investigate the effect of thread design on the bending strength of pedicle screw (dual threaded, double dual threaded and the dual lead dual threaded screw designs) under normal and osteoporotic bone conditions. The FEA results obtained show that the thread profile does influence the bending strength of a pedicle screw in normal and osteoporotic bones. The dual lead dual threaded pedicle screw showed an improvement of 1.88% in its deflection due to bending. While for the osteoporotic condition, the dual lead dual threaded pedicle screw showed an improvement of 32.3% in term of deflection. Thus, this finding have potential in assisting the optimum pedicle screw design in future although further investigation needed to support this finding.
- Open Access
- 31 July 2020
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 73 (2) , 29-45
Performance Enhancement of Energy Saving and Machining Characteristic in Electrical Discharge Machining on Magnesium Alloy: A Review
- 31 July 2020
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 73 (2) , 29-45
Open AccessPerformance Enhancement of Energy Saving and Machining Characteristic in Electrical Discharge Machining on Magnesium Alloy: A Review