Arman Shah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Arman Shah has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
S. Izman
Faculty of Mechanical Engineering Universiti Teknologi Malaysia 81310 SKUDAI, JOHOR MALAYSIA
10 shared publications- Rosdi Daud
Universiti Malaysia Pahang Al-Sultan Abdullah
6 shared publications H. Mas Ayu
University Malaysia Pahang
5 shared publicationsH. Mas-Ayu
Universiti Malaysia Pahang
5 shared publicationsR. Daud
Faculty of Mechanical Engineering Universiti Malaysia Pahang 26600 PEKAN, PAHANG DARUL MAKMUR MALAYSIA
5 shared publicationsM. A. Hassan
4 shared publications
Latest Publications
- Open Access
The Significant Effect of Mechanical Treatment on Ceramic Coating for Biomedical Application
Titanium and its alloys are commonly preferred materials used for biomedical implants. However, these alloys have issues related to corrosion resistance as a result of the aggressive attack of human body fluids. Several researchers have attempted to produce a ceramic coating via physical vapour deposition (PVD). A PVD layer consists of pores, pinholes, and columnar growth that attack the substrate as an aggressive medium. The aim of this research is to evaluate the influence of ultrasonic vibration parameters on a TiN-coated biomedical Ti-13Zr-13Nb alloy. This study used TiN to formulate and coat disk-type samples in a fixed condition. Ultrasonic vibration at fixed frequencies was applied to TiN-coated samples for three sets of exposure times. The findings revealed that all TiN-coated samples exposed to ultrasonic vibration had improved corrosion resistance compared to untreated samples. Field emission scanning electron microscopy (FESEM) was employed to analyse sample’s microstructures. The top parameter (16 kHz and 11 min) yielded the most compact coating. Ultrasonic vibration’s hammering effect decreased the size of microchannels in the lining and reduced the rate of corrosion attack. The nanoindentation test showed that coated ultrasonic treated samples had a higher hardness/elasticity (H/E) ratio than untreated samples.
Open AccessThe Significant Effect of Mechanical Treatment on Ceramic Coating for Biomedical Application
Titanium and its alloys are commonly preferred materials used for biomedical implants. However, these alloys have issues related to corrosion resistance as a result of the aggressive attack of human body fluids. Several researchers have attempted to produce a ceramic coating via physical vapour deposition (PVD). A PVD layer consists of pores, pinholes, and columnar growth that attack the substrate as an aggressive medium. The aim of this research is to evaluate the influence of ultrasonic vibration parameters on a TiN-coated biomedical Ti-13Zr-13Nb alloy. This study used TiN to formulate and coat disk-type samples in a fixed condition. Ultrasonic vibration at fixed frequencies was applied to TiN-coated samples for three sets of exposure times. The findings revealed that all TiN-coated samples exposed to ultrasonic vibration had improved corrosion resistance compared to untreated samples. Field emission scanning electron microscopy (FESEM) was employed to analyse sample’s microstructures. The top parameter (16 kHz and 11 min) yielded the most compact coating. Ultrasonic vibration’s hammering effect decreased the size of microchannels in the lining and reduced the rate of corrosion attack. The nanoindentation test showed that coated ultrasonic treated samples had a higher hardness/elasticity (H/E) ratio than untreated samples.
- Open Access
Geopolymer-Based Nepheline Ceramics: Effect of Sintering Profile on Morphological Characteristics and Flexural Strength
The focus of this study is the fabrication of innovative and sustainable ceramic-based geopolymer with improved low temperatures performances. Kaolin was mixed with liquid sodium silicate (Na2SiO3) and 12M of sodium hydroxide (NaOH) solution using alkali activator ratio of 0.24 and solid-to-liquid ratio of 1:1 to synthesize kaolin geopolymer. The effect of the sintering profile on the microstructure, pore evolution and flexural strength were investigated. The heating exposure aided consolidation and created a fairly uniform microstructure, resulting in a smooth surface texture. In comparison to the unheated geopolymer, 3D pore distribution showed a significant increase in the range size of ~30 µm with the appearance of isolated and intergranular pores. The flexural strength at 1200 °C with a heating rate of 5 °C/min and was increased by 146.4% to 85.4 MPa, as compared to the heating rate of 2 °C/min. The sintering process has an impact on the final microstructure formation thus improving the characteristic of geopolymer-based nepheline ceramic.
Open AccessGeopolymer-Based Nepheline Ceramics: Effect of Sintering Profile on Morphological Characteristics and Flexural Strength
The focus of this study is the fabrication of innovative and sustainable ceramic-based geopolymer with improved low temperatures performances. Kaolin was mixed with liquid sodium silicate (Na2SiO3) and 12M of sodium hydroxide (NaOH) solution using alkali activator ratio of 0.24 and solid-to-liquid ratio of 1:1 to synthesize kaolin geopolymer. The effect of the sintering profile on the microstructure, pore evolution and flexural strength were investigated. The heating exposure aided consolidation and created a fairly uniform microstructure, resulting in a smooth surface texture. In comparison to the unheated geopolymer, 3D pore distribution showed a significant increase in the range size of ~30 µm with the appearance of isolated and intergranular pores. The flexural strength at 1200 °C with a heating rate of 5 °C/min and was increased by 146.4% to 85.4 MPa, as compared to the heating rate of 2 °C/min. The sintering process has an impact on the final microstructure formation thus improving the characteristic of geopolymer-based nepheline ceramic.
- 19 September 2021
- Published by Taylor & Francis in Research in Science & Technological Education
- Vol. 41 (3) , 1008-1030
The innovative use of smartphone for sound STEM practical kit: a pilot implementation for secondary classroom
Recent studies have highlighted the application of STEM (Science, Technology, Engineering, and Mathematics) knowledge into daily life via hands-on practical works. The limitations of the existing c...
- 19 September 2021
- Published by Taylor & Francis in Research in Science & Technological Education
- Vol. 41 (3) , 1008-1030
The innovative use of smartphone for sound STEM practical kit: a pilot implementation for secondary classroom
Recent studies have highlighted the application of STEM (Science, Technology, Engineering, and Mathematics) knowledge into daily life via hands-on practical works. The limitations of the existing c...
- 25 December 2020
- Published by Institute of Metallurgy and Ore Benefication (Publications) in Kompleksnoe Ispolzovanie Mineralnogo Syra = Complex Use of Mineral Resources
- Vol. 315 (4) , 82-95
The effect of the catalytic layer composition on the hydrogen permeability of assymetric tantalum-based membranes
The paper offers the measuring results for hydrogen permeability of the membranes made of 40 μm thick tantalum foil covered with a metallic film with different thicknesses on one side. The measurements were performed when the membranes were in contact with a commercial argon and hydrogen gases mixed at the ratio of 1/5 at an overpressure of 500 kPa and at 580-585°C. It is shown that films of Mo, Re, W, Cu, Co, and Ni metals deposited on the tantalum membrane surface from the side facing a hydrogen-containing gas mixture increase its hydrogen permeability. The effect degree of these metals increases in the specified row from left to right. The effect on the hydrogen permeability of tantalum membranes, comparable to and superior to the deposition of a Pd film, exerts the deposition of Cu, Co, and Ni films. It is explained by the high hydrogen permeability level of these metals and the catalytic activity of their surface that results in intense hydrogen dissociation. The value of the hydrogen permeability of the membranes naturally increases with a thickness decrease of metallic films, however, it is obvious that this behavior is not linear. The hydrogen permeability of membranes with Cu, Co, and Ni films decreases over time, that is explained by the oxygen segregation at the Ta membrane/film interface, as well as by the processes on the membrane surface in contact with the gas mixture. The nature of these processes should be studies since the lower oxides of these metals are reduced by hydrogen at this temperature.
- 25 December 2020
- Published by Institute of Metallurgy and Ore Benefication (Publications) in Kompleksnoe Ispolzovanie Mineralnogo Syra = Complex Use of Mineral Resources
- Vol. 315 (4) , 82-95
The effect of the catalytic layer composition on the hydrogen permeability of assymetric tantalum-based membranes
The paper offers the measuring results for hydrogen permeability of the membranes made of 40 μm thick tantalum foil covered with a metallic film with different thicknesses on one side. The measurements were performed when the membranes were in contact with a commercial argon and hydrogen gases mixed at the ratio of 1/5 at an overpressure of 500 kPa and at 580-585°C. It is shown that films of Mo, Re, W, Cu, Co, and Ni metals deposited on the tantalum membrane surface from the side facing a hydrogen-containing gas mixture increase its hydrogen permeability. The effect degree of these metals increases in the specified row from left to right. The effect on the hydrogen permeability of tantalum membranes, comparable to and superior to the deposition of a Pd film, exerts the deposition of Cu, Co, and Ni films. It is explained by the high hydrogen permeability level of these metals and the catalytic activity of their surface that results in intense hydrogen dissociation. The value of the hydrogen permeability of the membranes naturally increases with a thickness decrease of metallic films, however, it is obvious that this behavior is not linear. The hydrogen permeability of membranes with Cu, Co, and Ni films decreases over time, that is explained by the oxygen segregation at the Ta membrane/film interface, as well as by the processes on the membrane surface in contact with the gas mixture. The nature of these processes should be studies since the lower oxides of these metals are reduced by hydrogen at this temperature.
- 25 September 2020
- Published by Institute of Metallurgy and Ore Benefication (Publications) in Kompleksnoe Ispolzovanie Mineralnogo Syra = Complex Use of Mineral Resources
- Vol. 314 (3) , 76-83
Obtaining hydroxyapatite coatings by mechanochemical interaction
The research represents a newly-developed simple method to apply hydroxyapatite by gas-dynamic spraying. The hydroxyapatite coating formed on VT1-0 titanium were obtained following the mechanochemical interaction of hydroxyapatite and titanium with gas-dynamic spraying. The article proposes the phase composition, surface morphology, and roughness of these coatings. The surface morphology of the hydroxyapatite coating had a porous structure. The transverse sections of coatings were researched to study the interaction of hydroxyapatite with a titanium base. It was shown that the coatings mainly form in the titanium bedding depressions. Analyzing the roughness parameter Ra of hydroxyapatite coatings made it possible to conclude that the samples obtained fell almost within the same limits. These data are within the roughness optimum (Ra = 2-3 μm) of artificial surfaces aimed to manifest the best human osteogenic properties. The analyzed phase composition enabled to establish the fact that the hydroxyapatite layer composition does not change significantly after spraying that is important for biomedical use.
- 25 September 2020
- Published by Institute of Metallurgy and Ore Benefication (Publications) in Kompleksnoe Ispolzovanie Mineralnogo Syra = Complex Use of Mineral Resources
- Vol. 314 (3) , 76-83
Obtaining hydroxyapatite coatings by mechanochemical interaction
The research represents a newly-developed simple method to apply hydroxyapatite by gas-dynamic spraying. The hydroxyapatite coating formed on VT1-0 titanium were obtained following the mechanochemical interaction of hydroxyapatite and titanium with gas-dynamic spraying. The article proposes the phase composition, surface morphology, and roughness of these coatings. The surface morphology of the hydroxyapatite coating had a porous structure. The transverse sections of coatings were researched to study the interaction of hydroxyapatite with a titanium base. It was shown that the coatings mainly form in the titanium bedding depressions. Analyzing the roughness parameter Ra of hydroxyapatite coatings made it possible to conclude that the samples obtained fell almost within the same limits. These data are within the roughness optimum (Ra = 2-3 μm) of artificial surfaces aimed to manifest the best human osteogenic properties. The analyzed phase composition enabled to establish the fact that the hydroxyapatite layer composition does not change significantly after spraying that is important for biomedical use.
- Open Access
- 20 September 2020
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 75 (3) , 126-139
Phase Transitions in Casting Process of Beryllium Oxide Slip
- 20 September 2020
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 75 (3) , 126-139
Open AccessPhase Transitions in Casting Process of Beryllium Oxide Slip
- Open Access
- 31 July 2020
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 73 (2) , 29-45
Performance Enhancement of Energy Saving and Machining Characteristic in Electrical Discharge Machining on Magnesium Alloy: A Review
- 31 July 2020
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 73 (2) , 29-45
Open AccessPerformance Enhancement of Energy Saving and Machining Characteristic in Electrical Discharge Machining on Magnesium Alloy: A Review
- Open Access
- 7 April 2020
- Published by International Association of Online Engineering (IAOE) in International Journal of Interactive Mobile Technologies (iJIM)
- Vol. 14 (05) , 203-209
The Usage of Mobile Learning: Comparative Studies among Technical and Vocational Education Students in Selected Universities
This research is conducted mainly to examine the difference among Technical and Vocational Education (TVE) students at Universiti Pendidikan Sultan Idris (UPSI) and Universiti Tun Hussein Onn Malaysia (UTHM)on their computer proficiency, knowledge on mobile learning(ML), application preferred, and attitude towards ML. Quantitative research method via questionnaire distributed to 618 participants. T-test analysis was used to obtainthe differences among students in both the universities via Statistical Package for Social Sciences (SPSS) version 23.0 for Windows. The results showed there was no difference found among these students. Hereby, ML is vital for lifelong learning and the access to mobile devices are available for everyone these days. It has made ML to be a tool to learn regardless of time and place among the students today.
- 7 April 2020
- Published by International Association of Online Engineering (IAOE) in International Journal of Interactive Mobile Technologies (iJIM)
- Vol. 14 (05) , 203-209
Open AccessThe Usage of Mobile Learning: Comparative Studies among Technical and Vocational Education Students in Selected Universities
This research is conducted mainly to examine the difference among Technical and Vocational Education (TVE) students at Universiti Pendidikan Sultan Idris (UPSI) and Universiti Tun Hussein Onn Malaysia (UTHM)on their computer proficiency, knowledge on mobile learning(ML), application preferred, and attitude towards ML. Quantitative research method via questionnaire distributed to 618 participants. T-test analysis was used to obtainthe differences among students in both the universities via Statistical Package for Social Sciences (SPSS) version 23.0 for Windows. The results showed there was no difference found among these students. Hereby, ML is vital for lifelong learning and the access to mobile devices are available for everyone these days. It has made ML to be a tool to learn regardless of time and place among the students today.
- 20 September 2019
- Published by Springer Nature
- p. 33-39
Prediction of Fatigue Failure Location on Lower Control Arm Using Finite Element Analysis (Stress Life Method)
- 20 September 2019
- Published by Springer Nature
- p. 33-39
Prediction of Fatigue Failure Location on Lower Control Arm Using Finite Element Analysis (Stress Life Method)
- 7 March 2019
- Published by Wiley in Materialwissenschaft und Werkstofftechnik
- Vol. 50 (3) , 254-259
Improving biocompatibility of cobalt based alloy using chemical etching and mechanical treatment
Biomedical grade of cobalt based alloy have found a plethora of applications as medical devices especially in dental and articulation joints like in total ankle, knee and hip arthroplasty. However, the long‐term performance of this material is highly dependent on their ability to withstand in harsh aqueous environment effects such as corrosion and wear once they are used inside a human body. Loss of surface integrity and subsequent leaching of toxic metal ions as well as particles to the surrounding tissues may undermine biocompatibility of metallic implants, also potentially causing untimely loss of mechanical function and device failure. In this study, a biomedical grade of Co−Cr−Mo alloy surface was treated with various surface modification techniques such as chemical etching and mechanical roughening in order to improve its biocompatibility. Investigation was done to study which surface modification techniques possesses the positive effect in cell growth and exhibit excellent cell response on Co−Cr−Mo alloy. In‐vitro study showed that human osteoblast cells grown with good adherence and spread out with an intimate contact on the chemical treated surface after 14 days of incubation. It is believed that porous structure with grooves owned by chemical treated surface helps in anchoring the cells to the substrate surface and facilitates cells growth since more protein molecules expected to have more sites on this surface. Whilst on mechanical roughened surface, the cells appeared to show slightly less extended cell membranes and the cells remained retarded.
- 7 March 2019
- Published by Wiley in Materialwissenschaft und Werkstofftechnik
- Vol. 50 (3) , 254-259
Improving biocompatibility of cobalt based alloy using chemical etching and mechanical treatment
Biomedical grade of cobalt based alloy have found a plethora of applications as medical devices especially in dental and articulation joints like in total ankle, knee and hip arthroplasty. However, the long‐term performance of this material is highly dependent on their ability to withstand in harsh aqueous environment effects such as corrosion and wear once they are used inside a human body. Loss of surface integrity and subsequent leaching of toxic metal ions as well as particles to the surrounding tissues may undermine biocompatibility of metallic implants, also potentially causing untimely loss of mechanical function and device failure. In this study, a biomedical grade of Co−Cr−Mo alloy surface was treated with various surface modification techniques such as chemical etching and mechanical roughening in order to improve its biocompatibility. Investigation was done to study which surface modification techniques possesses the positive effect in cell growth and exhibit excellent cell response on Co−Cr−Mo alloy. In‐vitro study showed that human osteoblast cells grown with good adherence and spread out with an intimate contact on the chemical treated surface after 14 days of incubation. It is believed that porous structure with grooves owned by chemical treated surface helps in anchoring the cells to the substrate surface and facilitates cells growth since more protein molecules expected to have more sites on this surface. Whilst on mechanical roughened surface, the cells appeared to show slightly less extended cell membranes and the cells remained retarded.