Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ionut Sebastian Vintila has a total of 77 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Dimensional fidelity and hydraulic performance assessment of additively manufactured polymer pump components for rapid design validation

    by Ionut Sebastian Vintila, Iulia Tinca, Alexa Miruna Canache, Teodor Stanescu, Radu Mihalache, Silviu Chitu, Mihai Vladut

  • Open Access

    CFD and Experimental Comparison for Micro-Pump Performance in Space Applications: A Case Study

    by Oana Dumitrescu, Cristian Dobromirescu, Valeriu Dragan, Ionut Sebastian Vintila, Radu Mihalache

    This paper presents a case study comparing CFD predictions with experimental measurements for micropumps, with the goal of evaluating the accuracy and limitations of CFD methods in complex microscale geometries. A fast design and evaluation methodology was developed, integrating linear design, 3D fully viscous CFD-based optimization, and rapid prototyping and testing. The main problem at this scale and configuration of pumps is the combination of Reynolds and Taylor numbers. Their impact on labyrinth performance prediction and therefore volumetric efficiency dominates the losses at this scale. Multiple CFD simulations were conducted using various turbulence models and solver settings, and results were compared against experimental data. The labyrinth region was simulated both independently and as part of the full pump assembly, with RANS and LES used for the former and RANS for the latter. Precision 3D-printed rotors and volutes were tested, and performance maps were obtained. Significant discrepancies between CFD and experiments were observed, which were reconciled using two empirical scaling coefficients for pressure and mass flow. These collapsed the CFD predictions onto the experimental data across all available speedlines. While the generalizability of these coefficients remains uncertain, the concept of using corrected scales, rather than other methods, seems to capture the macroscopic discrepancies between CFD and experiments.


  • Open Access

    Hydraulic Performance Comparison of Centrifugal Closed Impellers Fabricated by Means of Additive Manufacturing and Classical Machining for Space Active Thermal Control Systems of Satellites

    by Ionut-Florian Popa, Cristian Dobromirescu, Ionut Sebastian Vintila, Iulia Tinca, Dragos Mihai, Alexa Miruna Canache, Daniel Eugeniu Crunteanu

    The current paper addresses the challenges in manufacturing a critical component of a centrifugal pump for space active thermal control systems of satellites, namely, the closed centrifugal impeller. Compared to the classical technologies, there is an obvious advantage of additive manufacturing of closed impellers, due to the possibility of creating complex geometries, which boost the hydraulic performances of the part and, implicitly, of the pump. In this regard, the authors performed a comparative analysis between a closed impeller obtained by classical machining and three manufactured by additive technology (selective laser melting) by means of dimensional inspection, non-destructive testing, and experimental evaluation. The study performed here showed that the additively manufactured closed impellers exhibited similar hydraulic performances to the classical one, without the need for performing post-processing of internal surfaces. Also, in terms of dimensional and geometrical stability, the additively manufactured closed impellers were within the imposed tolerances, demonstrating the feasibility of obtaining such complex parts by using additive manufacturing. Subsequently, the allocated time for manufacturing decreased by 75% for the closed impellers manufactured by additive technologies, and the need for using four technological processes was decreased to only two, printing and post-processing.


  • Open Access

    Preliminary Design of a Lightweight Composite Backing Structure for a Satellite Antenna

    by Emil Nutu, Ionut Sebastian Vintila, Florin Stuparu, George Pelin, Gabriel Gheorghe Jiga

    The paper consists of a preliminary design and analysis of a lightweight composite backing structure for a side deployable solid mesh reflector intended for telecom application in the Ka‐Band. As the entire antenna reflector must withstand the forces related to the launching loads, the focus is addressed to the stiffness of the composite backing structure, so that the reflective metallic mesh will not be affected during launching phase, thus with no influence over the possible deformation of the mesh and on its radio frequency performance. It is shown that the proposed concept withstands the imposed launching requirements with a compromise on mass properties.

  • Open Access

    A Microvascular System Self-Healing Approach on Polymeric Composite Materials

    by Ionut Sebastian Vintila, Jana Ghitman, Horia Iovu, Alexandru Paraschiv, Andreia Cucuruz, Dragos Mihai, Ionut Florian Popa

    The paper addresses the synthesis of a nano-fibre network by coaxial electrospinning, embedding the healing agent dicyclopentadiene (DCPD) in polyacrylonitrile (PAN) fibres. Compared to other encapsulation methods, the use of nano-fibres filled with healing agent have no effect on the mechanical properties of the matrix and can address a larger healing area. Additionally, carbon nanotubes were added as nanofillers to enhance the reactivity between DCPD and the epoxydic matrix. The self-healing capability of the nano-fibre network was carried out by flexural tests, at epoxy resin level and composite level. Results obtained from Fourier transform infrared (FTIR) spectrometry, thermogravimetric analysis (TGA) and scanning electron microscopy (SEM) confirmed the successful encapsulation of DCPD healing agent in PAN fibres. Flexural tests indicate that after 48 h, the epoxy resin has recovered 84% of its flexural strength while the composite material recovered 93%.


  • Open Access

    Manufacturing of Closed Impeller for Mechanically Pump Fluid Loop Systems Using Selective Laser Melting Additive Manufacturing Technology

    by Alexandra Adiaconitei, Ionut Sebastian Vintila, Radu Mihalache, Alexandru Paraschiv, Tiberius Florian Frigioescu, Ionut Florian Popa, Laurent Pambaguian

    In the space industry, the market demand for high-pressure mechanically pumped fluid loop (MPFL) systems has increased the interest for integrating advanced technologies in the manufacturing process of critical components with complex geometries. The conventional manufacturing process of a closed impeller encounters different technical challenges, but using additive manufacturing (AM) technology, the small component is printed, fulfilling the quality requirements. This paper presents the Laser Powder Bed Fusion (LPBF) process of a closed impeller designed for a centrifugal pump integrated in an MPFL system with the objective of defining a complete manufacturing process. A set of three closed impellers was manufactured, and each closed impeller was subjected to dimensional accuracy analysis, before and after applying an iterative finishing process for the internal surface area. One of the impellers was validated through non-destructive testing (NDT) activities, and finally, a preliminary balancing was performed for the G2.5 class. The process setup (building orientation and support structure) defined in the current study for a pre-existing geometry of the closed impeller takes full advantages of LPBF technology and represents an important step in the development of complex structural components, increasing the technological readiness level of the AM process for space applications.


  • Open Access

    Novel Carbon Fibre Composite Centrifugal Impeller Design, Numerical Analysis, Manufacturing and Experimental Evaluations

    by Radu Mihalache, Ionut Sebastian Vintila, Marius Deaconu, Mihail Sima, Ion Malael, Alexandru Tudorache, Dragos Mihai

    This paper presents an experimental investigation on using high strength-to-weight composite materials to reduce the mass of a centrifugal compressor impeller by 600%. By reducing the blades number from 17 to 7 and by doubling their thickness, the compression ratio and efficiency were maintained close to the reference metallic impeller. Using autoclave technology, seven composite blades were manufactured individually and assembled to form the impeller. After manufacturing, small deviations were found at the blade’s tip. As these deviations were found to be symmetrical, impeller balancing was successfully performed removing a total of 45 g of mass, followed by an experimental test on a dedicated test bench. Experimental testing identified the resonant frequencies of the composite centrifugal impeller at 13.43 Hz 805 rot/min and at 77 Hz with a 0.1 mm/s amplitude at 4400 rot/min, highlighting feasibility and the advantage of a composite compressor impeller design with application in centrifugal compressors and rotating machine assemblies and sub-assemblies. As there are numerous numerical investigations performed on the strength analysis and on the lay-up orientations mechanical behaviour for polymer composite materials with respect to the design of centrifugal impellers, no experimental evaluations in relevant working conditions have been performed to date. As the paper contains relevant experimental data on the subject, the outcome of the paper may aid the oil and gas or aviation industries.


  • Open Access

    Closing Force Evaluation of a Sample Return Capsule for a Phobos Sample Return Mission

    by Radu Mihalache, Dragos Mihai, Gheorghe Megherelu, Ionut Florian Popa, Ionut Sebastian Vintila, Alexandru Paraschiv

    The mission objective of the Phobos Sample Return is to collect and return 100 g of Phobos’ surface material to Earth inside a tight enclosure composed of a Vault, a Sample Container and sealing elements. One important aspect of the project was the development of a closing mechanism capable of ensuring a pushing force high enough compared to the available force of the robotic arm (40 N). The need for a higher pushing force derived from the design tests which were carried out to experimentally determine the necessary force to overcome the resistance of the sealing element when the vault is closed. Two types of sealing elements, custom made for this project, along with two SC with different geometrical shapes in the sealing area were tested. For better accuracy, the tests considered the imposed operational temperature domain for the vault, ECSS standards and the test rig set-up being performed at environmental temperature (+20 °C), −20 °C, −60 °C and +70 °C. The results of the tests highlighted that the negative temperature has a significant influence over the closing force, as this force is increasing once the operational temperature is decreasing. Based on the work performed, the most suitable type of sealing element was identified, in particular the piston geometry which allows a smaller force to close the vault.

  • Open Access

    Design, analysis and evaluation of titanium antenna reflector for deep space missions

    by Dragos Mihai, Radu Mihalache, Ionut Florian Popa, Ionut Sebastian Vintila, Daniel Datcu, Ion Ciocan, Viorel Braic, Iulian Pana, Adrian Emil Kiss, Nicolae Catalin Zoita, et al.


  • Open Access

    Evaluation of Dispersion Methods and Mechanical Behaviour of Glass Fibre Composites with Embedded Self-Healing Systems

    by Ionut Sebastian Vintila, Sorin Draghici, Horia Alexandru Petrescu, Alexandru Paraschiv, Mihaela Raluca Condruz, Lucia Raluca Maier, Adela Bara, Madalina Necolau

    The present paper is focused on evaluating the most suitable dispersion method in the epoxy matrix of two self-healing systems containing dicyclopentadiene (DCPD) and 5-ethylidene-2-norbornene (ENB) monomers encapsulated in a urea-formaldehyde (UF) shell, prior to integration, fabrication and impact testing of specimens. Both microstructural analysis and three-point bending tests were performed to evaluate and assess the optimum dispersion method. It was found that ultrasonication damages the microcapsules of both healing systems, thus magnetic stirring was used for the dispersion of both healing systems in the epoxy matrix. Using magnetic dispersion, 5%, 7%, 10%, 12% and 15% volumes of microcapsules were embedded in glass fibre composites. Some of the samples were subjected to thermal cycling between −20 °C and +100 °C for 8 h, to evaluate the behaviour of both healing systems after temperature variation. Impact test results showed that the mechanical behaviour decreases with increasing microcapsule volume, while for specimens subjected to thermal cycling, the impact strength increases with microcapsule volume up to 10%, after which a severe drop in impact strength follows. Retesting after 48 h shows a major drop in mechanical properties in specimens containing 15% MUF-ENB microcapsules, up to total penetration of the specimen.