    Predicting the daily gastrointestinal doses of stereotactic body radiation therapy for pancreatic cancer based on the shortest distance between the tumor and the gastrointestinal tract using daily computed tomography images

    by Yusuke Uchinami, Takahiro Kanehira, Keiji Nakazato, Yoshihiro Fujita, Fuki Koizumi, Shuhei Takahashi, Manami Otsuka, Koichi Yasuda, Hiroshi Taguchi, Kentaro Nishioka, et al.

    Objectives: We aimed to investigate whether daily computed tomography (CT) images could predict the daily gastroduodenal, small intestine, and large intestine doses of stereotactic body radiation therapy (SBRT) for pancreatic cancer based on the shortest distance between the gross tumor volume (GTV) and gastrointestinal (GI) tract. Methods: Twelve patients with pancreatic cancer received SBRT of 40 Gy in five fractions. We recalculated the reference clinical SBRT plan (PLANref) using daily CT images and calculated the shortest distance from the GTV to each GI tract. The maximum dose delivered to 0.5 cc (D0.5cc) was evaluated for each planning at-risk volume of the GI tract. Spearman’s correlation test was used to determine the association between the daily change in the shortest distance (Δshortest distance) and the ratio of ΔD0.5cc dose to D0.5cc dose in PLANref (ΔD0.5cc/PLANref) for quantitative analysis. Results: The median shortest distance in PLANref was 0 mm in the gastroduodenum (interquartile range, 0–2.7), 16.7 mm in the small intestine (10.0–23.7), and 16.7 mm in the large intestine (8.3–28.1 mm). The D0.5cc of PLANref in the gastroduodenum was >30 Gy in all patients, with 10 (83.3%) having the highest dose. A significant association was found between the Δshortest distance and ΔD0.5cc/ PLANref in the small or large intestine (p < 0.001) but not in the gastroduodenum (p = 0.404). Conclusions: The gastroduodenum had a higher D0.5cc and predicting the daily dose was difficult. Daily dose calculations of the GI tract are recommended for safe SBRT. Advances in knowledge: This study aimed to predict the daily doses in SBRT for pancreatic cancer from the shortest distance between the GTV and the gastrointestinal tract. Daily changes in the shortest distance can predict the daily dose to the small or large intestines, but not to the gastroduodenum.

  • Study of hepatic toxicity in small liver tumors after photon or proton therapy based on factors predicting the benefits of proton

    by Yusuke Uchinami, Norio Katoh, Daisuke Abo, Ryo Morita, Hiroshi Taguchi, Yoshihiro Fujita, Takahiro Kanehira, Ryusuke Suzuki, Naoki Miyamoto, Seishin Takao, et al.

    Objectives: In a previous study of hepatic toxicity, the following three factors were identified to predict the benefits of proton beam therapy (PBT) for hepatocellular carcinomas (HCCs) with a maximum diameter of ≤5 cm and Child-pugh grade A (CP-A): number of tumors (1 vs ≥2), the location of tumors (hepatic hilum or others), and the sum of the diameters of lesions. The aim of this study is to analyze the association between these three factors and hepatic toxicity. Methods: We retrospectively reviewed patients of CP-A treated with PBT or photon stereotactic body radiotherapy (X-ray radiotherapy, XRT) for HCC ≤5 cm. For normal liver dose, the V5, V10, V20 (volumes receiving 5, 10, and 20 Gy at least), and the mean dose was evaluated. The albumin-bilirubin (ALBI) and CP score changes from the baseline were evaluated at 3 and 6 months after treatment. Results: In 89 patients (XRT: 48, PBT: 41), those with two or three (2–3) predictive factors were higher normal liver doses than with zero or one (0–1) factor. In the PBT group, the ALBI score worsened more in patients with 2–3 factors than those with 0–1 factor, at 3 months (median: 0.26 vs 0.02, p = 0.032) and at 6 months (median: 0.35 vs 0.10, p = 0.009). The ALBI score change in the XRT group and CP score change in either modality were not significantly different in the number of predictive factors. Conclusion: The predictive factor numbers predicted the ALBI score change in PBT but not in XRT. Advances in knowledge: This study suggest that the number of predictive factors previously identified (0–1 vs 2–3) were significantly associated with dosimetric parameters of the normal liver in both modalities. In the proton group, the number of predictive factors was associated with a worsening ALBI score at 3 and 6 months, but these associations were not found in the photon SBRT group.


  • Open Access

    Analysis of inter- and intra fractional partial bladder wall movement using implanted fiducial markers

    by Kentaro Nishioka, Shinichi Shimizu, Nobuo Shinohara, Yoichi M. Ito, Takashige Abe, Satoru Maruyama, Norio Katoh, Rumiko Kinoshita, Takayuki Hashimoto, Naoki Miyamoto, et al.

    Current adaptive and dose escalating radiotherapy for muscle invasive bladder cancer requires knowledge of both inter-fractional and intra-fractional motion of the bladder wall involved. The purpose of this study is to characterize inter- and intra-fractional movement of the partial bladder wall using implanted fiducial markers and a real-time tumor-tracking radiotherapy system. Two hundred fifty one sessions with 29 patients were analysed. After maximal transurethral bladder tumor resection and 40 Gy of whole bladder irradiation, up to six gold markers were implanted transurethrally into the bladder wall around the tumor bed and used for positional registration. We compared the systematic and random uncertainty of positions between cranial vs. caudal, left vs. right, and anterior vs. posterior tumor groups. The variance in intrafractional movement and the percentage of sessions where 3 mm and 5 mm or more of intrafractional wall movement occurring at 2, 4, 6, 8, 10, and at more than 10 min until the end of a session were determined. The cranial and anterior tumor group showed larger interfractional uncertainties in the position than the opposite side tumor group in the CC and AP directions respectively, but these differences did not reach significance. Among the intrafractional uncertainty of position, the cranial and anterior tumor group showed significantly larger systematic uncertainty of position than the groups on the opposite side in the CC direction. The variance of intrafractional movement increased over time; the percentage of sessions where intrafractional wall movement was larger than 3 mm within 2 min of the start of a radiation session or larger than 5 mm within 10 min was less than 5%, but this percentage was increasing further during the session, especially in the cranial and anterior tumor group. More attention for intrafractional uncertainty of position is required in the treatment of cranial and anterior bladder tumors especially in the CC direction. The optimal internal margins in each direction should be chosen or a precise intrafractional target localization system is required depending on the tumor location and treatment delivery time in the setting of partial bladder radiotherapy.


  • Open Access

    Optimization and evaluation of multiple gating beam delivery in a synchrotron-based proton beam scanning system using a real-time imaging technique

    by Takahiro Yamada, Naoki Miyamoto, Taeko Matsuura, Seishin Takao, Yusuke Fujii, Yuka Matsuzaki, Hidenori Koyano, Masumi Umezawa, Hideaki Nihongi, Shinichi Shimizu, et al.


  • International standardization of four dimensional radiotherapy system

    by Yuichi Hirata, Naoki Miyamoto, Morihito Shimizu, Mitsuhiro Yoshida, Kazuo Hiramoto, Yoshiaki Ichikawa, Shuji Kaneko, Tsuyoshi Sasagawa, Masahiro Hiraoka, Hiroki Shirato

    In radiation therapy for cancer, there are possibilities of position changes of the affected area during irradiation due to respiration of a patient. In order to enhance effects of irradiation for the affected area and minimize damages to the surrounding normal tissues, four dimensional radiotherapy (4DRT), which can take into account time variation of the three-dimensional position of the affected area, has been recently developed, and has been achieving significant therapeutic effects. We have proposed the International Electrotechnical Commission (IEC) standards including technical requirements of the safety aspects of the systems which realize this 4DRT, taking into account the time aspect. The reason for the proposal is that international standardization will be very effective to ensure safety of 4DRT, and international standards of IEC will have compelling force if regulatory agencies refer to them. The purpose of this paper is to summarize the analysis of the strategy in a precedent endeavor toward international standardization of the 4DRT systems, for which demands are increasing. The main point of the strategy is forming an international consensus by bringing together the opinions of specialists from various fields from a clinical point of view, focusing on the international standardization of the technical requirements of the safety aspects of the 4DRT. Based on such a strategy, we will promote developing new standards by evaluating the overall safety of the 4DRT systems for further expanding use, in addition to updating existing standards of particular equipment which constitute the 4DRT systems.


  • Open Access

    What is the appropriate size criterion for proton radiotherapy for hepatocellular carcinoma? A dosimetric comparison of spot-scanning proton therapy versus intensity-modulated radiation therapy

    by Chie Toramatsu, Norio Katoh, Shinichi Shimizu, Hideaki Nihongi, Taeko Matsuura, Seishin Takao, Naoki Miyamoto, Ryusuke Suzuki, Kenneth Sutherland, Rumiko Kinoshita, et al.

    Background: We performed a dosimetric comparison of spot-scanning proton therapy (SSPT) and intensity-modulated radiation therapy (IMRT) for hepatocellular carcinoma (HCC) to investigate the impact of tumor size on the risk of radiation induced liver disease (RILD). Methods: A number of alternative plans were generated for 10 patients with HCC. The gross tumor volumes (GTV) varied from 20.1 to 2194.5 cm3. Assuming all GTVs were spherical, the nominal diameter was calculated and ranged from 3.4 to 16.1 cm. The prescription dose was 60 Gy for IMRT or 60 cobalt Gy-equivalents for SSPT with 95% planning target volume (PTV) coverage. Using IMRT and SSPT techniques, extensive comparative planning was conducted. All plans were evaluated by the risk of RILD estimated using the Lyman-normal-tissue complication probability model. Results: For IMRT the risk of RILD increased drastically between 6.3–7.8 cm nominal diameter of GTV. When the nominal diameter of GTV was more than 6.3 cm, the average risk of RILD was 94.5% for IMRT and 6.2% for SSPT. Conclusions: Regarding the risk of RILD, HCC can be more safely treated with SSPT, especially if its nominal diameter is more than 6.3 cm.


  • Improvement of tracking accuracy and stability by recursive image processing in real-time tumor-tracking radiotherapy system

    by Naoki Miyamoto, Kenneth Sutherland, Ryusuke Suzuki, Taeko Matsuura, Chie Toramatsu, Seishin Takao, Hideaki Nihongi, Rumiko Kinoshita, Shinichi Shimizu, Rikiya Onimaru, et al.

    In the real-time tumor-tracking radiotherapy (RTRT) system, the fiducial markers are inserted in or near the target tumor in order monitor the respiratory-induced motion of tumors. During radiation treatment, the markers are detected by continuous fluoroscopy operated at 30 frames/sec. The marker position is determined by means of a template pattern matching technique which is based on the normalized cross correlation. With high tube voltage, large current and long exposure, the fiducial marker will be recognized accurately, however, the radiation dose due to X-ray fluoroscopy increases. On the other hand, by decreasing the fluoroscopy parameter settings, the fiducial marker could be lost because the effect of statistical noise is increased. In the respiratory-gated radiotherapy, the error of the image guidance will induce the reduction of the irradiation efficiency and accuracy. In order to track the marker stably and accurately in low dose fluoroscopy, we propose the application of a recursive filter. The effectiveness of the image processing is investigated by tracking the static marker and the dynamic marker. The results suggest that the stability and the accuracy of the marker tracking can be improved by applying the recursive image filter in low dose imaging.

  • Optimization of fluoroscopy parameters using pattern matching prediction in the real-time tumor-tracking radiotherapy system

    by Naoki Miyamoto, Masayori Ishikawa, Gerard Bengua, Kenneth Sutherland, Ryusuke Suzuki, Suguru Kimura, Shinichi Shimizu, Rikiya Onimaru, Hiroki Shirato

    In the real-time tumor-tracking radiotherapy system, fluoroscopy is used to determine the real-time position of internal fiducial markers. The pattern recognition score (PRS) ranging from 0 to 100 is computed by a template pattern matching technique in order to determine the marker position on the fluoroscopic image. The PRS depends on the quality of the fluoroscopic image. However, the fluoroscopy parameters such as tube voltage, current and exposure duration are selected manually and empirically in the clinical situation. This may result in an unnecessary imaging dose from the fluoroscopy or loss of the marker because of too much or insufficient x-ray exposure. In this study, a novel optimization method is proposed in order to minimize the fluoroscopic dose while keeping the image quality usable for marker tracking. The PRS can be predicted in a region where the marker appears to move in the fluoroscopic image by the proposed method. The predicted PRS can be utilized to judge whether the marker can be tracked with accuracy. In this paper, experiments were performed to show the feasibility of the PRS prediction method under various conditions. The predicted PRS showed good agreement with the measured PRS. The root mean square error between the predicted PRS and the measured PRS was within 1.44. An experiment using a motion controller and an anthropomorphic chest phantom was also performed in order to imitate a clinical fluoroscopy situation. The result shows that the proposed prediction method is expected to be applicable in a real clinical situation.