Ryusuke Suzuki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ryusuke Suzuki has a total of 139 co-authors. Here are the top co-authors by number of shared publications:
- Hiroki Shirato
Hokkaido University
8 shared publications - Masayori Ishikawa
Graduate School of Biomedical Science and Engineering, Hokkaido University, Sapporo, Japan
6 shared publications - Rikiya Onimaru
Department of Radiation Medicine, Faculty of Medicine, Hokkaido University, Sapporo, Japan
6 shared publications - Norio Katoh
Department of Radiation Oncology, Hokkaido University Faculty of Medicine, Sapporo, Japan
5 shared publications - Naoki Miyamoto
Department of Medical Physics, Hokkaido University Hospital, Sapporo, Japan
4 shared publications - Shinichi Shimizu
Department of Carbon Ion Radiotherapy, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan
4 shared publications
Latest Publications
- Open Access
- 24 June 2026
- Published by Oxford University Press (OUP) in Japanese Journal of Clinical Oncology
- Vol. 56 (10) , 1272-1279
A multicenter randomized phase III trial of weekly cisplatin chemoradiotherapy versus radiotherapy in elderly patients with head and neck squamous cell carcinoma unfit for high-dose cisplatin: JCOG2405 (ELDER-WEEKLY)
Chemoradiotherapy (CRT) with high-dose cisplatin (100 mg/m2) is the standard treatment for locally advanced squamous cell carcinoma of the head and neck (SCCHN). However, this regimen is often intolerable in elderly patients because of its toxicity, and the optimal treatment for those unfit for high-dose cisplatin remains unclear. CRT with weekly cisplatin (40 mg/m2) has been developed as a more tolerable alternative and has demonstrated comparable efficacy with reduced toxicity in several trials involving nonelderly patients. We therefore designed a multicenter, randomized phase III trial (JCOG2405) to confirm the superiority of CRT with weekly cisplatin over radiotherapy alone in patients aged ≥70 years with locally advanced SCCHN who are unfit for high-dose cisplatin. The primary endpoint is overall survival. A total of 250 patients from 59 institutions will be enrolled over 5 years. The trial has been registered in the Japan Registry of Clinical Trials (study number: jRCTs031250688).
- 24 June 2026
- Published by Oxford University Press (OUP) in Japanese Journal of Clinical Oncology
- Vol. 56 (10) , 1272-1279
Open AccessA multicenter randomized phase III trial of weekly cisplatin chemoradiotherapy versus radiotherapy in elderly patients with head and neck squamous cell carcinoma unfit for high-dose cisplatin: JCOG2405 (ELDER-WEEKLY)
Chemoradiotherapy (CRT) with high-dose cisplatin (100 mg/m2) is the standard treatment for locally advanced squamous cell carcinoma of the head and neck (SCCHN). However, this regimen is often intolerable in elderly patients because of its toxicity, and the optimal treatment for those unfit for high-dose cisplatin remains unclear. CRT with weekly cisplatin (40 mg/m2) has been developed as a more tolerable alternative and has demonstrated comparable efficacy with reduced toxicity in several trials involving nonelderly patients. We therefore designed a multicenter, randomized phase III trial (JCOG2405) to confirm the superiority of CRT with weekly cisplatin over radiotherapy alone in patients aged ≥70 years with locally advanced SCCHN who are unfit for high-dose cisplatin. The primary endpoint is overall survival. A total of 250 patients from 59 institutions will be enrolled over 5 years. The trial has been registered in the Japan Registry of Clinical Trials (study number: jRCTs031250688).
- Open Access
- 25 December 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (4) , e14250
A new predictive parameter for dose‐volume metrics in intensity‐modulated radiation therapy planning for prostate cancer: Initial phantom study
Background: Organ‐at‐risk (OAR) sparing is often assessed using an overlap volume‐based parameter, defined as the ratio of the volume of OAR that overlaps the planning target volume (PTV) to the whole OAR volume. However, this conventional overlap‐based predictive parameter (COPP) does not consider the volume relationship between the PTV and OAR.Purpose: We propose a new overlap‐based predictive parameter that consider the PTV volume. The effectiveness of proposed overlap‐based predictive parameter (POPP) is evaluated compared with COPP.Methods: We defined as POPP = (overlap volume between OAR and PTV/OAR volume) × (PTV volume/OAR volume). We generated intensity modulated radiation therapy (IMRT) based on step and shoot technique, and volumetric modulated arc therapy (VMAT) plans with the Auto‐Planning module of Pinnacle3 treatment planning system (v14.0, Philips Medical Systems, Fitchburg, WI) using the American Association of Physicists in Medicine Task Group (TG119) prostate phantom. The relationship between the position and size of the prostate phantom was systematically modified to simulate various geometric arrangements. The correlation between overlap‐based predictive parameters (COPP and POPP) and dose‐volume metrics (mean dose, V70Gy, V60Gy, and V37.5 Gy for rectum and bladder) was investigated using linear regression analysis.Results: Our results indicated POPP was better than COPP in predicting intermediate‐dose metrics. The bladder results showed a trend similar to that of the rectum. The correlation coefficient of POPP was significantly greater than that of COPP in < 62 Gy (82% of the prescribed dose) region for IMRT and in < 55 Gy (73% of the prescribed dose) region for VMAT regarding the rectum (p < 0.05).Conclusions: POPP is superior to COPP for creating predictive models at an intermediate‐dose level. Because rectal bleeding and bladder toxicity can be associated with intermediate‐doses as well as high‐doses, it is important to predict dose‐volume metrics for various dose levels. POPP is a useful parameter for predicting dose‐volume metrics and assisting the generation of treatment plans.
- 25 December 2023
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 25 (4) , e14250
Open AccessA new predictive parameter for dose‐volume metrics in intensity‐modulated radiation therapy planning for prostate cancer: Initial phantom study
Background: Organ‐at‐risk (OAR) sparing is often assessed using an overlap volume‐based parameter, defined as the ratio of the volume of OAR that overlaps the planning target volume (PTV) to the whole OAR volume. However, this conventional overlap‐based predictive parameter (COPP) does not consider the volume relationship between the PTV and OAR.Purpose: We propose a new overlap‐based predictive parameter that consider the PTV volume. The effectiveness of proposed overlap‐based predictive parameter (POPP) is evaluated compared with COPP.Methods: We defined as POPP = (overlap volume between OAR and PTV/OAR volume) × (PTV volume/OAR volume). We generated intensity modulated radiation therapy (IMRT) based on step and shoot technique, and volumetric modulated arc therapy (VMAT) plans with the Auto‐Planning module of Pinnacle3 treatment planning system (v14.0, Philips Medical Systems, Fitchburg, WI) using the American Association of Physicists in Medicine Task Group (TG119) prostate phantom. The relationship between the position and size of the prostate phantom was systematically modified to simulate various geometric arrangements. The correlation between overlap‐based predictive parameters (COPP and POPP) and dose‐volume metrics (mean dose, V70Gy, V60Gy, and V37.5 Gy for rectum and bladder) was investigated using linear regression analysis.Results: Our results indicated POPP was better than COPP in predicting intermediate‐dose metrics. The bladder results showed a trend similar to that of the rectum. The correlation coefficient of POPP was significantly greater than that of COPP in < 62 Gy (82% of the prescribed dose) region for IMRT and in < 55 Gy (73% of the prescribed dose) region for VMAT regarding the rectum (p < 0.05).Conclusions: POPP is superior to COPP for creating predictive models at an intermediate‐dose level. Because rectal bleeding and bladder toxicity can be associated with intermediate‐doses as well as high‐doses, it is important to predict dose‐volume metrics for various dose levels. POPP is a useful parameter for predicting dose‐volume metrics and assisting the generation of treatment plans.
- Open Access
- 1 August 2023
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 5 (1) , 20230043
Predicting the daily gastrointestinal doses of stereotactic body radiation therapy for pancreatic cancer based on the shortest distance between the tumor and the gastrointestinal tract using daily computed tomography images
Objectives: We aimed to investigate whether daily computed tomography (CT) images could predict the daily gastroduodenal, small intestine, and large intestine doses of stereotactic body radiation therapy (SBRT) for pancreatic cancer based on the shortest distance between the gross tumor volume (GTV) and gastrointestinal (GI) tract. Methods: Twelve patients with pancreatic cancer received SBRT of 40 Gy in five fractions. We recalculated the reference clinical SBRT plan (PLANref) using daily CT images and calculated the shortest distance from the GTV to each GI tract. The maximum dose delivered to 0.5 cc (D0.5cc) was evaluated for each planning at-risk volume of the GI tract. Spearman’s correlation test was used to determine the association between the daily change in the shortest distance (Δshortest distance) and the ratio of ΔD0.5cc dose to D0.5cc dose in PLANref (ΔD0.5cc/PLANref) for quantitative analysis. Results: The median shortest distance in PLANref was 0 mm in the gastroduodenum (interquartile range, 0–2.7), 16.7 mm in the small intestine (10.0–23.7), and 16.7 mm in the large intestine (8.3–28.1 mm). The D0.5cc of PLANref in the gastroduodenum was >30 Gy in all patients, with 10 (83.3%) having the highest dose. A significant association was found between the Δshortest distance and ΔD0.5cc/ PLANref in the small or large intestine (p < 0.001) but not in the gastroduodenum (p = 0.404). Conclusions: The gastroduodenum had a higher D0.5cc and predicting the daily dose was difficult. Daily dose calculations of the GI tract are recommended for safe SBRT. Advances in knowledge: This study aimed to predict the daily doses in SBRT for pancreatic cancer from the shortest distance between the GTV and the gastrointestinal tract. Daily changes in the shortest distance can predict the daily dose to the small or large intestines, but not to the gastroduodenum.
- 1 August 2023
- Published by Oxford University Press (OUP) in BJR|Open
- Vol. 5 (1) , 20230043
Open AccessPredicting the daily gastrointestinal doses of stereotactic body radiation therapy for pancreatic cancer based on the shortest distance between the tumor and the gastrointestinal tract using daily computed tomography images
Objectives: We aimed to investigate whether daily computed tomography (CT) images could predict the daily gastroduodenal, small intestine, and large intestine doses of stereotactic body radiation therapy (SBRT) for pancreatic cancer based on the shortest distance between the gross tumor volume (GTV) and gastrointestinal (GI) tract. Methods: Twelve patients with pancreatic cancer received SBRT of 40 Gy in five fractions. We recalculated the reference clinical SBRT plan (PLANref) using daily CT images and calculated the shortest distance from the GTV to each GI tract. The maximum dose delivered to 0.5 cc (D0.5cc) was evaluated for each planning at-risk volume of the GI tract. Spearman’s correlation test was used to determine the association between the daily change in the shortest distance (Δshortest distance) and the ratio of ΔD0.5cc dose to D0.5cc dose in PLANref (ΔD0.5cc/PLANref) for quantitative analysis. Results: The median shortest distance in PLANref was 0 mm in the gastroduodenum (interquartile range, 0–2.7), 16.7 mm in the small intestine (10.0–23.7), and 16.7 mm in the large intestine (8.3–28.1 mm). The D0.5cc of PLANref in the gastroduodenum was >30 Gy in all patients, with 10 (83.3%) having the highest dose. A significant association was found between the Δshortest distance and ΔD0.5cc/ PLANref in the small or large intestine (p < 0.001) but not in the gastroduodenum (p = 0.404). Conclusions: The gastroduodenum had a higher D0.5cc and predicting the daily dose was difficult. Daily dose calculations of the GI tract are recommended for safe SBRT. Advances in knowledge: This study aimed to predict the daily doses in SBRT for pancreatic cancer from the shortest distance between the GTV and the gastrointestinal tract. Daily changes in the shortest distance can predict the daily dose to the small or large intestines, but not to the gastroduodenum.
- 23 January 2023
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1144) , 20220720
Study of hepatic toxicity in small liver tumors after photon or proton therapy based on factors predicting the benefits of proton
Objectives: In a previous study of hepatic toxicity, the following three factors were identified to predict the benefits of proton beam therapy (PBT) for hepatocellular carcinomas (HCCs) with a maximum diameter of ≤5 cm and Child-pugh grade A (CP-A): number of tumors (1 vs ≥2), the location of tumors (hepatic hilum or others), and the sum of the diameters of lesions. The aim of this study is to analyze the association between these three factors and hepatic toxicity. Methods: We retrospectively reviewed patients of CP-A treated with PBT or photon stereotactic body radiotherapy (X-ray radiotherapy, XRT) for HCC ≤5 cm. For normal liver dose, the V5, V10, V20 (volumes receiving 5, 10, and 20 Gy at least), and the mean dose was evaluated. The albumin-bilirubin (ALBI) and CP score changes from the baseline were evaluated at 3 and 6 months after treatment. Results: In 89 patients (XRT: 48, PBT: 41), those with two or three (2–3) predictive factors were higher normal liver doses than with zero or one (0–1) factor. In the PBT group, the ALBI score worsened more in patients with 2–3 factors than those with 0–1 factor, at 3 months (median: 0.26 vs 0.02, p = 0.032) and at 6 months (median: 0.35 vs 0.10, p = 0.009). The ALBI score change in the XRT group and CP score change in either modality were not significantly different in the number of predictive factors. Conclusion: The predictive factor numbers predicted the ALBI score change in PBT but not in XRT. Advances in knowledge: This study suggest that the number of predictive factors previously identified (0–1 vs 2–3) were significantly associated with dosimetric parameters of the normal liver in both modalities. In the proton group, the number of predictive factors was associated with a worsening ALBI score at 3 and 6 months, but these associations were not found in the photon SBRT group.
- 23 January 2023
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 96 (1144) , 20220720
Study of hepatic toxicity in small liver tumors after photon or proton therapy based on factors predicting the benefits of proton
Objectives: In a previous study of hepatic toxicity, the following three factors were identified to predict the benefits of proton beam therapy (PBT) for hepatocellular carcinomas (HCCs) with a maximum diameter of ≤5 cm and Child-pugh grade A (CP-A): number of tumors (1 vs ≥2), the location of tumors (hepatic hilum or others), and the sum of the diameters of lesions. The aim of this study is to analyze the association between these three factors and hepatic toxicity. Methods: We retrospectively reviewed patients of CP-A treated with PBT or photon stereotactic body radiotherapy (X-ray radiotherapy, XRT) for HCC ≤5 cm. For normal liver dose, the V5, V10, V20 (volumes receiving 5, 10, and 20 Gy at least), and the mean dose was evaluated. The albumin-bilirubin (ALBI) and CP score changes from the baseline were evaluated at 3 and 6 months after treatment. Results: In 89 patients (XRT: 48, PBT: 41), those with two or three (2–3) predictive factors were higher normal liver doses than with zero or one (0–1) factor. In the PBT group, the ALBI score worsened more in patients with 2–3 factors than those with 0–1 factor, at 3 months (median: 0.26 vs 0.02, p = 0.032) and at 6 months (median: 0.35 vs 0.10, p = 0.009). The ALBI score change in the XRT group and CP score change in either modality were not significantly different in the number of predictive factors. Conclusion: The predictive factor numbers predicted the ALBI score change in PBT but not in XRT. Advances in knowledge: This study suggest that the number of predictive factors previously identified (0–1 vs 2–3) were significantly associated with dosimetric parameters of the normal liver in both modalities. In the proton group, the number of predictive factors was associated with a worsening ALBI score at 3 and 6 months, but these associations were not found in the photon SBRT group.
- 25 July 2022
- Published by Elsevier in Brachytherapy
- Vol. 21 (6) , 956-967
Multi-Institutional Study of End-to-End Dose Delivery Quality Assurance Testing for Image-Guided Brachytherapy Using a Gel Dosimeter
- 25 July 2022
- Published by Elsevier in Brachytherapy
- Vol. 21 (6) , 956-967
Multi-Institutional Study of End-to-End Dose Delivery Quality Assurance Testing for Image-Guided Brachytherapy Using a Gel Dosimeter
- Open Access
- 2 June 2021
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (7) , 165-176
Fundamental study on quality assurance (QA) procedures for a real‐time tumor tracking radiotherapy (RTRT) system from the viewpoint of imaging devices
Purpose The real-time tumor tracking radiotherapy (RTRT) system requires periodic quality assurance (QA) and quality control. The goal of this study is to propose QA procedures from the viewpoint of imaging devices in the RTRT system. Methods Tracking by the RTRT system (equips two sets of colored image intensifiers (colored I.I.s) fluoroscopy units) for the moving gold-marker (diameter 2.0 mm) in a rotating phantom were performed under various X-ray conditions. To analyze the relationship between fluoroscopic image quality and precision of gold marker coordinate calculation, the standard deviation of the 3D coordinate (σ3D [mm]) of the gold marker, the mean of the pattern recognition score (PRS) and the standard deviation of the distance between rays (DBR) (σDBR [mm]) were evaluated. Results When tracking with speed of 10-60 mm/s, σDBR increased, though the mean PRS did not change significantly (p>0.05). On the contrary, the mean PRS increased depending on the integral noise equivalent quanta (∫NEQ) that is an indicator of image quality calculated from the modulation transfer function (MTF) as an indicator of spatial resolution and the noise power spectrum (NPS) as an indicator of noise characteristic. Conclusion The indicators of NEQ, MTF, and NPS were useful for managing the tracking accuracy of the RTRT system. We propose observing the change of these indicators as additional QA procedures for each imaging device from the commissioning baseline.
- 2 June 2021
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 22 (7) , 165-176
Open AccessFundamental study on quality assurance (QA) procedures for a real‐time tumor tracking radiotherapy (RTRT) system from the viewpoint of imaging devices
Purpose The real-time tumor tracking radiotherapy (RTRT) system requires periodic quality assurance (QA) and quality control. The goal of this study is to propose QA procedures from the viewpoint of imaging devices in the RTRT system. Methods Tracking by the RTRT system (equips two sets of colored image intensifiers (colored I.I.s) fluoroscopy units) for the moving gold-marker (diameter 2.0 mm) in a rotating phantom were performed under various X-ray conditions. To analyze the relationship between fluoroscopic image quality and precision of gold marker coordinate calculation, the standard deviation of the 3D coordinate (σ3D [mm]) of the gold marker, the mean of the pattern recognition score (PRS) and the standard deviation of the distance between rays (DBR) (σDBR [mm]) were evaluated. Results When tracking with speed of 10-60 mm/s, σDBR increased, though the mean PRS did not change significantly (p>0.05). On the contrary, the mean PRS increased depending on the integral noise equivalent quanta (∫NEQ) that is an indicator of image quality calculated from the modulation transfer function (MTF) as an indicator of spatial resolution and the noise power spectrum (NPS) as an indicator of noise characteristic. Conclusion The indicators of NEQ, MTF, and NPS were useful for managing the tracking accuracy of the RTRT system. We propose observing the change of these indicators as additional QA procedures for each imaging device from the commissioning baseline.
- Open Access
- 10 August 2019
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 20 (8) , 78-86
Impact of organ motion on volumetric and dosimetric parameters in stomach lymphomas treated with intensity‐modulated radiotherapy
Purpose: Interplay effects may influence dose distributions to a moving target when using dynamic delivery techniques such as intensity‐modulated radiotherapy (IMRT). The aim of this study was to evaluate the impact of organ motion on volumetric and dosimetric parameters in stomach lymphomas treated with IMRT.Methods: Ten patients who had been treated with IMRT for stomach lymphomas were enrolled. The clinical target volume (CTV) was contoured as the whole stomach. Considering interfractional uncertainty, the internal target volume (ITV) margin was uniformly 1.5 cm to the CTV and then modified based on the 4DCT images in case of the large respiratory motion. The planning target volume (PTV) was created by adding 5 mm to the ITV. The impact of organ motion on the volumetric and dosimetric parameters was evaluated retrospectively (4D simulation). The organ motion was reproduced by shifting the isocenter on the radiation treatment planning system. Several simulation plans were created to test the influence of the beam‐on timing in the respiration cycle on the dose distribution. The homogeneity index (HI), volume percentage of stomach covered by the prescribed dose (Vp), and D99 of the CTV were evaluated.Results: The organ motion was the largest in the superior‐inferior direction (10.1 ± 4.5 mm [average ± SD]). Stomach volume in each respiratory phase compared to the mean volume varied approximately within a ± 5% range in most of the patients. The PTV margin was sufficiently large to cover the CTV during the IMRT. There was a significant reduction in Vp and D99 but not in HI in the 4D simulation in free‐breathing and multiple fractions compared to the clinically‐used plan (P < 0.05) suggesting that interplay effects deteriorate the dose distribution. The absolute difference of D99 was less than 1% of the prescribed dose.Conclusions: There were significant interplay effects affecting the dose distribution in stomach IMRT. The magnitude of the dose reduction was small when patients were treated on free‐breathing and multiple fractions.
- 10 August 2019
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 20 (8) , 78-86
Open AccessImpact of organ motion on volumetric and dosimetric parameters in stomach lymphomas treated with intensity‐modulated radiotherapy
Purpose: Interplay effects may influence dose distributions to a moving target when using dynamic delivery techniques such as intensity‐modulated radiotherapy (IMRT). The aim of this study was to evaluate the impact of organ motion on volumetric and dosimetric parameters in stomach lymphomas treated with IMRT.Methods: Ten patients who had been treated with IMRT for stomach lymphomas were enrolled. The clinical target volume (CTV) was contoured as the whole stomach. Considering interfractional uncertainty, the internal target volume (ITV) margin was uniformly 1.5 cm to the CTV and then modified based on the 4DCT images in case of the large respiratory motion. The planning target volume (PTV) was created by adding 5 mm to the ITV. The impact of organ motion on the volumetric and dosimetric parameters was evaluated retrospectively (4D simulation). The organ motion was reproduced by shifting the isocenter on the radiation treatment planning system. Several simulation plans were created to test the influence of the beam‐on timing in the respiration cycle on the dose distribution. The homogeneity index (HI), volume percentage of stomach covered by the prescribed dose (Vp), and D99 of the CTV were evaluated.Results: The organ motion was the largest in the superior‐inferior direction (10.1 ± 4.5 mm [average ± SD]). Stomach volume in each respiratory phase compared to the mean volume varied approximately within a ± 5% range in most of the patients. The PTV margin was sufficiently large to cover the CTV during the IMRT. There was a significant reduction in Vp and D99 but not in HI in the 4D simulation in free‐breathing and multiple fractions compared to the clinically‐used plan (P < 0.05) suggesting that interplay effects deteriorate the dose distribution. The absolute difference of D99 was less than 1% of the prescribed dose.Conclusions: There were significant interplay effects affecting the dose distribution in stomach IMRT. The magnitude of the dose reduction was small when patients were treated on free‐breathing and multiple fractions.
- Open Access
- 21 May 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 118
Early results of urethral dose reduction and small safety margin in intensity-modulated radiation therapy (IMRT) for localized prostate cancer using a real-time tumor-tracking radiotherapy (RTRT) system
We prospectively assessed the utility of intensity-modulated radiation therapy (IMRT) with urethral dose reduction and a small margin between the clinical target volume (CTV) and the planning target volume (PTV) for patients with localized prostate cancer.
- 21 May 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 118
Open AccessEarly results of urethral dose reduction and small safety margin in intensity-modulated radiation therapy (IMRT) for localized prostate cancer using a real-time tumor-tracking radiotherapy (RTRT) system
We prospectively assessed the utility of intensity-modulated radiation therapy (IMRT) with urethral dose reduction and a small margin between the clinical target volume (CTV) and the planning target volume (PTV) for patients with localized prostate cancer.
- Open Access
- 21 March 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 69
Stereotactic body radiotherapy using gated radiotherapy with real-time tumor-tracking for stage I non-small cell lung cancer
Background: To clarify the clinical outcomes of two dose schedule of stereotactic body radiotherapy (SBRT) for stage I non-small cell lung cancer (NSCLC) using a real-time tumor-tracking radiation therapy (RTRT) system in single institution. Methods: Using a superposition algorithm, we administered 48 Gy in 4 fractions at the isocenter in 2005–2006 and 40 Gy in 4 fractions to the 95% volume of PTV in 2007–2010 with a treatment period of 4 to 7 days. Target volume margins were fixed irrespective of the tumor amplitude. Results: In total, 109 patients (79 T1N0M0 and 30 T2N0M0). With a median follow-up period of 25 months (range, 4 to 72 months), the 5-year local control rate (LC) was 78% and the 5-year overall survival rate (OS) was 64%. Grade 2, 3, 4, and 5 radiation pneumonitis (RP) was experienced by 15 (13.8%), 3 (2.8%), 0, and 0 patients, respectively. The mean lung dose (MLD) and the volume of lung receiving 20 Gy (V20) were significantly higher in patients with RP Grade 2/3 than in those with RP Grade 0/1 (MLD p = 0.002, V20 p = 0.003). There was no correlation between larger maximum amplitude of marker movement and larger PTV (r = 0.137), MLD (r = 0.046), or V20 (r = 0.158). Conclusions: SBRT using the RTRT system achieved LC and OS comparable to other SBRT studies with very low incidence of RP, which was consistent with the small MLD and V20 irrespective of tumor amplitude. For stage I NSCLC, SBRT using RTRT was suggested to be reliable and effective, especially for patients with large amplitude of tumor movement.
- 21 March 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 69
Open AccessStereotactic body radiotherapy using gated radiotherapy with real-time tumor-tracking for stage I non-small cell lung cancer
Background: To clarify the clinical outcomes of two dose schedule of stereotactic body radiotherapy (SBRT) for stage I non-small cell lung cancer (NSCLC) using a real-time tumor-tracking radiation therapy (RTRT) system in single institution. Methods: Using a superposition algorithm, we administered 48 Gy in 4 fractions at the isocenter in 2005–2006 and 40 Gy in 4 fractions to the 95% volume of PTV in 2007–2010 with a treatment period of 4 to 7 days. Target volume margins were fixed irrespective of the tumor amplitude. Results: In total, 109 patients (79 T1N0M0 and 30 T2N0M0). With a median follow-up period of 25 months (range, 4 to 72 months), the 5-year local control rate (LC) was 78% and the 5-year overall survival rate (OS) was 64%. Grade 2, 3, 4, and 5 radiation pneumonitis (RP) was experienced by 15 (13.8%), 3 (2.8%), 0, and 0 patients, respectively. The mean lung dose (MLD) and the volume of lung receiving 20 Gy (V20) were significantly higher in patients with RP Grade 2/3 than in those with RP Grade 0/1 (MLD p = 0.002, V20 p = 0.003). There was no correlation between larger maximum amplitude of marker movement and larger PTV (r = 0.137), MLD (r = 0.046), or V20 (r = 0.158). Conclusions: SBRT using the RTRT system achieved LC and OS comparable to other SBRT studies with very low incidence of RP, which was consistent with the small MLD and V20 irrespective of tumor amplitude. For stage I NSCLC, SBRT using RTRT was suggested to be reliable and effective, especially for patients with large amplitude of tumor movement.
- Open Access
- 5 March 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 48
What is the appropriate size criterion for proton radiotherapy for hepatocellular carcinoma? A dosimetric comparison of spot-scanning proton therapy versus intensity-modulated radiation therapy
Background: We performed a dosimetric comparison of spot-scanning proton therapy (SSPT) and intensity-modulated radiation therapy (IMRT) for hepatocellular carcinoma (HCC) to investigate the impact of tumor size on the risk of radiation induced liver disease (RILD). Methods: A number of alternative plans were generated for 10 patients with HCC. The gross tumor volumes (GTV) varied from 20.1 to 2194.5 cm3. Assuming all GTVs were spherical, the nominal diameter was calculated and ranged from 3.4 to 16.1 cm. The prescription dose was 60 Gy for IMRT or 60 cobalt Gy-equivalents for SSPT with 95% planning target volume (PTV) coverage. Using IMRT and SSPT techniques, extensive comparative planning was conducted. All plans were evaluated by the risk of RILD estimated using the Lyman-normal-tissue complication probability model. Results: For IMRT the risk of RILD increased drastically between 6.3–7.8 cm nominal diameter of GTV. When the nominal diameter of GTV was more than 6.3 cm, the average risk of RILD was 94.5% for IMRT and 6.2% for SSPT. Conclusions: Regarding the risk of RILD, HCC can be more safely treated with SSPT, especially if its nominal diameter is more than 6.3 cm.
- 5 March 2013
- Published by Springer Nature in Radiation Oncology
- Vol. 8 (1) , 48
Open AccessWhat is the appropriate size criterion for proton radiotherapy for hepatocellular carcinoma? A dosimetric comparison of spot-scanning proton therapy versus intensity-modulated radiation therapy
Background: We performed a dosimetric comparison of spot-scanning proton therapy (SSPT) and intensity-modulated radiation therapy (IMRT) for hepatocellular carcinoma (HCC) to investigate the impact of tumor size on the risk of radiation induced liver disease (RILD). Methods: A number of alternative plans were generated for 10 patients with HCC. The gross tumor volumes (GTV) varied from 20.1 to 2194.5 cm3. Assuming all GTVs were spherical, the nominal diameter was calculated and ranged from 3.4 to 16.1 cm. The prescription dose was 60 Gy for IMRT or 60 cobalt Gy-equivalents for SSPT with 95% planning target volume (PTV) coverage. Using IMRT and SSPT techniques, extensive comparative planning was conducted. All plans were evaluated by the risk of RILD estimated using the Lyman-normal-tissue complication probability model. Results: For IMRT the risk of RILD increased drastically between 6.3–7.8 cm nominal diameter of GTV. When the nominal diameter of GTV was more than 6.3 cm, the average risk of RILD was 94.5% for IMRT and 6.2% for SSPT. Conclusions: Regarding the risk of RILD, HCC can be more safely treated with SSPT, especially if its nominal diameter is more than 6.3 cm.