Harry Boyer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Harry Boyer has a total of 76 co-authors. Here are the top co-authors by number of shared publications:
- Bruno Malet-Damour
PIMENT Laboratory, University of Reunion Island, 120 Avenue Raymond Barre, 97430 Le Tampon, La Réunion, France
9 shared publications F. Miranville
Physics and Mathematical Engineering Laboratory for Energy and Environment (PIMENT) University of La Réunion 117 rue du Général Ailleret 97430 Le Tampon France
9 shared publications- Thierry Alex Mara
Université de La Réunion, PIMENT, 15 Avenue René Cassin, BP 7151, 97715 Moufia, La Réunion, France
7 shared publications - Alexandre Lefevre
PIMENT Laboratory, University of Reunion Island
6 shared publications - Frédéric Miranville
Physics and Mathematical Engineering Laboratory for Energy, Environment and Building (PIMENT) University of Reunion 117, rue du Général Ailleret 97 430 Le Tampon FRANCE
6 shared publications - Garry Rivière
PIMENT Laboratory, University of Reunion Island, 120 Avenue Raymond BARRE, 97430 Le Tampon, Reunion Island, France
6 shared publications
Latest Publications
- Open Access
- 12 August 2026
- Published by Elsevier in Data in Brief
- Vol. 68
Urban microclimate dataset from low-cost sensor networks in a hot and humid tropical climate: Reunion Island
- 12 August 2026
- Published by Elsevier in Data in Brief
- Vol. 68
Open AccessUrban microclimate dataset from low-cost sensor networks in a hot and humid tropical climate: Reunion Island
- Open Access
Field Validation of ENVI-Met for Outdoor Thermal Comfort Assessment in a Dense Tropical Neighbourhood: A Case Study on Reunion Island
Dense tropical cities face increasing outdoor heat stress and require reliable microclimate modelling tools to support climate-responsive urban planning. However, the performance of these models remains insufficiently documented under tropical conditions. The objective of this study is to experimentally validate the performance of ENVI-met for outdoor thermal comfort assessment in a dense tropical neighbourhood on Reunion Island. Validation was performed using a network of 11 low-cost weather stations distributed across the study area, providing observations of air temperature, relative humidity, wind speed and globe temperature, from which mean radiant temperature (MRT) and the Universal Thermal Climate Index (UTCI) were derived. Model performance was evaluated through multipoint validation, error-propagation analysis and sensitivity experiments. Results show that ENVI-met reproduces air temperature and relative humidity with good accuracy (RMSE of 1.2 °C and 5%), while larger uncertainties are observed for wind speed (up to 4 m s−1) and MRT (up to 8 °C), with strong spatial variability. Error-propagation analysis indicates that 62% of the UTCI error variance is explained by combined microclimate simulation errors, with radiative conditions emerging as the dominant contributor. Sensitivity analyses identify boundary wind forcing as the main source of modelling uncertainty. Overall, the proposed validation framework provides practical guidance for improving ENVI-met applications in tropical urban environments and supports more robust climate-responsive urban design.
Open AccessField Validation of ENVI-Met for Outdoor Thermal Comfort Assessment in a Dense Tropical Neighbourhood: A Case Study on Reunion Island
Dense tropical cities face increasing outdoor heat stress and require reliable microclimate modelling tools to support climate-responsive urban planning. However, the performance of these models remains insufficiently documented under tropical conditions. The objective of this study is to experimentally validate the performance of ENVI-met for outdoor thermal comfort assessment in a dense tropical neighbourhood on Reunion Island. Validation was performed using a network of 11 low-cost weather stations distributed across the study area, providing observations of air temperature, relative humidity, wind speed and globe temperature, from which mean radiant temperature (MRT) and the Universal Thermal Climate Index (UTCI) were derived. Model performance was evaluated through multipoint validation, error-propagation analysis and sensitivity experiments. Results show that ENVI-met reproduces air temperature and relative humidity with good accuracy (RMSE of 1.2 °C and 5%), while larger uncertainties are observed for wind speed (up to 4 m s−1) and MRT (up to 8 °C), with strong spatial variability. Error-propagation analysis indicates that 62% of the UTCI error variance is explained by combined microclimate simulation errors, with radiative conditions emerging as the dominant contributor. Sensitivity analyses identify boundary wind forcing as the main source of modelling uncertainty. Overall, the proposed validation framework provides practical guidance for improving ENVI-met applications in tropical urban environments and supports more robust climate-responsive urban design.
- Top Cited PapersOpen Access
- 27 April 2026
- Published by Elsevier in Urban Climate
- Vol. 67
From urban heat island to thermal resilience: Lessons from low-cost microclimate monitoring in a small tropical island
- 27 April 2026
- Published by Elsevier in Urban Climate
- Vol. 67
Top Cited PapersOpen AccessFrom urban heat island to thermal resilience: Lessons from low-cost microclimate monitoring in a small tropical island
- Top Cited PapersOpen Access
- 14 November 2025
- Published by Elsevier in City and Environment Interactions
- Vol. 28
Urban heat island in the tropics: A review of advances, challenges, and future directions
- 14 November 2025
- Published by Elsevier in City and Environment Interactions
- Vol. 28
Top Cited PapersOpen AccessUrban heat island in the tropics: A review of advances, challenges, and future directions
- Open Access
- 3 June 2025
- Published by Elsevier in Data in Brief
- Vol. 61, 111747
Urban morphology dataset of Reunion Island based on the local climate zone classification using satellite imagery and GIS data
- 3 June 2025
- Published by Elsevier in Data in Brief
- Vol. 61, 111747
Open AccessUrban morphology dataset of Reunion Island based on the local climate zone classification using satellite imagery and GIS data
- Open Access
- 8 April 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (7) , 3093
Advancing Urban Microclimate Monitoring: The Development of an Environmental Data Measurement Station Using a Low-Tech Approach
Researchers studying urban climates aim to understand phenomena like urban heat islands (UHIs), which describe temperature differences between urban and rural areas. However, studies often lack numerous measurement points and frequently overlook parameters like radiation and air velocity due to the high cost of precision instrumentation. This results in data with a low resolution, particularly in tropical cities where official weather stations are scarce. This research introduces a new, low-tech tool for district-level outdoor thermal comfort assessment and UHI characterization to address these challenges. The automated weather station employs sensors to measure temperature, humidity, wind speed, solar radiation, and globe temperature. The paper details these sensors’ rigorous selection and validation process, followed by a description of the sensor assembly, data acquisition chain, and network operation mechanisms. Calibration outcomes in laboratory and in situ environments highlight the station’s reliability, even in tropical conditions. In conclusion, this weather station offers a cost-effective solution to gathering high-resolution data in urban areas, enabling an improved understanding of the UHI phenomenon and the refinement of urban microclimate numerical models.
- 8 April 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (7) , 3093
Open AccessAdvancing Urban Microclimate Monitoring: The Development of an Environmental Data Measurement Station Using a Low-Tech Approach
Researchers studying urban climates aim to understand phenomena like urban heat islands (UHIs), which describe temperature differences between urban and rural areas. However, studies often lack numerous measurement points and frequently overlook parameters like radiation and air velocity due to the high cost of precision instrumentation. This results in data with a low resolution, particularly in tropical cities where official weather stations are scarce. This research introduces a new, low-tech tool for district-level outdoor thermal comfort assessment and UHI characterization to address these challenges. The automated weather station employs sensors to measure temperature, humidity, wind speed, solar radiation, and globe temperature. The paper details these sensors’ rigorous selection and validation process, followed by a description of the sensor assembly, data acquisition chain, and network operation mechanisms. Calibration outcomes in laboratory and in situ environments highlight the station’s reliability, even in tropical conditions. In conclusion, this weather station offers a cost-effective solution to gathering high-resolution data in urban areas, enabling an improved understanding of the UHI phenomenon and the refinement of urban microclimate numerical models.
- Open Access
- 1 March 2020
- Published by European Open Science in European Journal of Engineering and Technology Research
- Vol. 5 (3) , 375-386
Technological Review of Tubular Daylight Guide System from 1982 to 2020
T.D.G.S., “Tubular Daylight Guidance Systems”, are natural lighting processes based on the transport of light. In 1990, they were judged by Littlefair as the most innovative technology in daylighting [1]. From 1982 to 2020, this paper is a state of the art on the different processes of tubular daylight guide systems. The key words used to carry out the census are light pipe; light tube; light guide; sun pipes; solar pipes; solar light pipes; daylight pipes; tubular skylight; sun scoop; tubular daylighting device; tubular daylight guide systems; mirrored light pipe. A classification by type of process is proposed (collection, transport or diffusion) for each technology identified in the literature.
- 1 March 2020
- Published by European Open Science in European Journal of Engineering and Technology Research
- Vol. 5 (3) , 375-386
Open AccessTechnological Review of Tubular Daylight Guide System from 1982 to 2020
T.D.G.S., “Tubular Daylight Guidance Systems”, are natural lighting processes based on the transport of light. In 1990, they were judged by Littlefair as the most innovative technology in daylighting [1]. From 1982 to 2020, this paper is a state of the art on the different processes of tubular daylight guide systems. The key words used to carry out the census are light pipe; light tube; light guide; sun pipes; solar pipes; solar light pipes; daylight pipes; tubular skylight; sun scoop; tubular daylighting device; tubular daylight guide systems; mirrored light pipe. A classification by type of process is proposed (collection, transport or diffusion) for each technology identified in the literature.
- 1 January 2017
- Published by EJournal Publishing in Journal of Clean Energy Technologies
- Vol. 5 (1) , 73-76
Performance Testing of Light Pipes in Real Weather Conditions for a Confrontation with Hemera
- 1 January 2017
- Published by EJournal Publishing in Journal of Clean Energy Technologies
- Vol. 5 (1) , 73-76
Performance Testing of Light Pipes in Real Weather Conditions for a Confrontation with Hemera
- Open Access
Empirical Validation of a Thermal Model of a Complex Roof Including Phase Change Materials
This paper deals with the empirical validation of a building thermal model using a phase change material (PCM) in a complex roof. A mathematical model dedicated to phase change materials based on the heat apparent capacity method was implemented in a multi-zone building simulation code, the aim being to increase understanding of the thermal behavior of the whole building with PCM technologies. To empirically validate the model, the methodology is based both on numerical and experimental studies. A parametric sensitivity analysis was performed and a set of parameters of the thermal model have been identified for optimization. The use of a generic optimization program called GenOpt coupled to the building simulation code enabled to determine the set of adequate parameters. We first present the empirical validation methodology and main results of previous work. We then give an overview of GenOpt and its coupling with the building simulation code. Finally, once the optimization results are obtained, comparisons of thermal model of PCM with measurements are found to be acceptable and are presented.
Open AccessEmpirical Validation of a Thermal Model of a Complex Roof Including Phase Change Materials
This paper deals with the empirical validation of a building thermal model using a phase change material (PCM) in a complex roof. A mathematical model dedicated to phase change materials based on the heat apparent capacity method was implemented in a multi-zone building simulation code, the aim being to increase understanding of the thermal behavior of the whole building with PCM technologies. To empirically validate the model, the methodology is based both on numerical and experimental studies. A parametric sensitivity analysis was performed and a set of parameters of the thermal model have been identified for optimization. The use of a generic optimization program called GenOpt coupled to the building simulation code enabled to determine the set of adequate parameters. We first present the empirical validation methodology and main results of previous work. We then give an overview of GenOpt and its coupling with the building simulation code. Finally, once the optimization results are obtained, comparisons of thermal model of PCM with measurements are found to be acceptable and are presented.
- Open Access
Empirical Validation of a Thermal Model of a Complex Roof Including Phase Change Materials
This paper deals with the empirical validation of a building thermal model of a complex roof including a phase change material (PCM). A mathematical model dedicated to PCMs based on the heat apparent capacity method was implemented in a multi-zone building simulation code, the aim being to increase the understanding of the thermal behavior of the whole building with PCM technologies. In order to empirically validate the model, the methodology is based both on numerical and experimental studies. A parametric sensitivity analysis was performed and a set of parameters of the thermal model has been identified for optimization. The use of the generic optimization program called GenOpt® coupled to the building simulation code enabled to determine the set of adequate parameters. We first present the empirical validation methodology and main results of previous work. We then give an overview of GenOpt® and its coupling with the building simulation code. Finally, once the optimization results are obtained, comparisons of the thermal predictions with measurements are found to be acceptable and are presented.
Open AccessEmpirical Validation of a Thermal Model of a Complex Roof Including Phase Change Materials
This paper deals with the empirical validation of a building thermal model of a complex roof including a phase change material (PCM). A mathematical model dedicated to PCMs based on the heat apparent capacity method was implemented in a multi-zone building simulation code, the aim being to increase the understanding of the thermal behavior of the whole building with PCM technologies. In order to empirically validate the model, the methodology is based both on numerical and experimental studies. A parametric sensitivity analysis was performed and a set of parameters of the thermal model has been identified for optimization. The use of the generic optimization program called GenOpt® coupled to the building simulation code enabled to determine the set of adequate parameters. We first present the empirical validation methodology and main results of previous work. We then give an overview of GenOpt® and its coupling with the building simulation code. Finally, once the optimization results are obtained, comparisons of the thermal predictions with measurements are found to be acceptable and are presented.