BWBryan C. Waltrip

Bryan C. Waltrip

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Bryan C. Waltrip has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Measurement of the Frequency Dependence of Four Terminal-Pair Air Capacitors With a Vector Network Analyzer

    by Stephan Schlamminger, Andrew D. Koffman, James W. Schmidt, Bryan C. Waltrip, Yicheng Wang

    Four terminal-pair air capacitors are important transfer standards to calibrate LCR meters up to a frequency of 10 MHz. We report a simple and new method to obtain the frequency dependence of the four terminal-pair capacitance of these standards using a four-channel vector network analyzer (VNA). The frequency dependence of the capacitance of an air capacitor and its uncertainty can be obtained from a single set of measurements without changing connections between the standard and the VNA, as has been the case in previously published work. The calculation of the frequency dependency is straightforward and model-independent. Nevertheless, an elementary model is provided to explain the observed frequency dependence. This article allows every laboratory with a four-channel VNA to measure the frequency dependence of these capacitors. Hence, a significant shortening of the traceability chain is achieved.


  • Open Access

    Comparison of a 100-pF Capacitor With a 12 906-Ω Resistor Using a Digital Impedance Bridge

    by Mona Feige, Stephan Schlamminger, Andrew D. Koffman, Dean G. Jarrett, Shamith Payagala, Alireza Panna, Bryan C. Waltrip, Michael Berilla, Frank Seifert, Yicheng Wang

    We tested a digital impedance bridge in a hybrid structure for comparison of a capacitor with a resistor where the impedance ratio was measured in two separate parts. The modulus of the impedance ratio was matched arbitrarily close to the input-to-output ratio, in magnitude, of a two-stage inductive voltage divider by adjusting the operating frequency of the bridge; the residual deviation between the two together with the phase factor of the impedance ratio was measured using a custom detection system based on a four-channel 24-bit digitizer. The ratio of the inductive voltage divider was calibrated, in situ, using a conventional four-arm bridge with two known capacitors. Fluctuations of the source voltages were largely removed through postprocessing of the digitized data, and the measurement results were limited by the digitizer error. We have achieved an overall bridge resolution and stability of 0.02 μF/F in 2 hours for measuring a 100 pF capacitor relative to a 12906 Ω resistor at 1233 Hz. The relative combined standard uncertainty (k = 1) is 0.13 μF/F, dominated by the digitizer error.


  • Open Access

    Evaluations of a Detector-Limited Digital Impedance Bridge

    by Mona Feige, Stephan Schlamminger, Bryan Waltrip, Michael Berilla, Yicheng Wang

    We tested a simple digital impedance bridge using two nominally equal resistors to form a 1:1 ratio. We focused on resolution and stability of the detectors. Fluctuations of the source voltages were largely removed through postprocessing of the digitized data, and the measurement results were limited by the detector noise. This detector-limited operating condition was first demonstrated using three modified Keysight 3458A multimeters for measurements of the voltage ratios, achieving 0.01 μV/V type A uncertainty in less than 15 min at 1 kHz. In an effort to extend the applicable frequency range and develop a system with off-the-shelf components, we tested a system using three lock-in detectors for measuring small deviations from the perfect AC ratio of unity magnitude, achieving stabilities and resolutions of 0.1 μV/V in a few hours for each point from 1 kHz to 5 kHz.


  • Comparison of AC Power Referenced to Either PJVS or JAWS

    by Bryan C. Waltrip, Thomas L. Nelson, Mike Berilla, Nathan E. Flowers-Jacobs, Paul D. Dresselhaus

    The results of a comparison on active power meter calibrations at the National Institute of Standards and Technology (NIST) using a source of AC power referenced to either a programmable Josephson voltage standard (PJVS) or a Josephson arbitrary waveform synthesizer (JAWS) is presented. The measurements were made at 60 V RMS, 5 A RMS, and 50 Hz at a power factor of 1.0. The estimated uncertainty of the active power applied to a meter under test (MUT) of the two system configurations is within 2 μW/VA (k=1), and the comparison results demonstrate that the two system configurations agree to within 1 part in 106 for applied voltage, current, and phase. A discussion of the measurement techniques and major sources of error is given for applied power signals over the 50 Hz to 6 kHz frequency range.


  • Bridge Measurement Analysis

    by Andrew Koffman, Bryan Waltrip, Svetlana Avramov-Zamurovic

    Bridge Measurement Analysis Svetlana Avramov-Zamurovic1, Bryan Waltrip2 and Andrew Koffman2 1 United States Naval Academy, Weapons and Systems Engineering Department Annapolis, MD 21402, Telephone: 410 293 6124 Email: avramov@usna.edu 2 National Institute of Standards and Technology†, Electricity Division Gaithersburg, MD 21899. Telephone: 301 975 2438, Email: bryan.waltrip@nist.gov Introduction At the United States Academy there are several engineering majors, including Systems Engineering. This program offers excellent systems integration education. In particular the major concentrates on control of electrical, computer and mechanical systems. In addition to several tracks, students have the opportunity to independently research a field of interest. This is a great opportunity for teachers and students to pursue more in-depth analyses. This paper will describe one such experiment in the field of metrology. Very often engineering laboratories at undergraduate schools are well equipped with power supplies, signal generators, oscilloscopes and general-purpose multimeters. This set allows teachers and students to set up test-beds for most of the basic electronics circuits studied in different engineering tracks. Modern instrumentation is in general user-friendly and students like using the equipment. However, students are often not aware that there are two pieces of information necessary to establish a measurement result: the numerical value of the measured quantity and the uncertainty with which that measurement was performed. In order to achieve high measurement accuracy, more complex measurement systems must be developed. This paper will describe the process of analyzing a bridge measurement using MATLAB‡. Measurement Bridge One of the basic circuits that demonstrate the concept of a current/voltage divider is a Wheatstone bridge (given in Figure 1.) A source voltage is applied to a parallel connection of impedances. The source current is divided into a branch with impedances Z1 and Z 2 and a branch with impedances Z3 and Z4. The current flows through the detector when the bridge is not balanced. In order for the student to understand the relationship between the current through the detector and the other elements in the bridge, it is beneficial to calculate the current through the detector. Electrical circuit analysis may be performed using symbolic functions in MATLAB. † Electricity Division, Electronics and Electrical Engineering Laboratory, Technology Administration, U.S. Department of Commerce. Official contribution of the National Institute of Standards and Technology; not subject to copyright in the United States. ‡ In order to describe the procedures discussed in this paper, commercial products are identified. In no case does such identification imply recommendation or endorsement by the National Institute of Standards and Technology or that the materials or equipment specified are necessarily the best available for the purpose.

  • A Lecture On Accurate Inductive Voltage Dividers

    by Andrew Koffman, Bryan Waltrip, George Piper, Svetlana Avramov-Zamurovic

    Main Menu Session 2559 A Lecture on Accurate Inductive Voltage Dividers Svetlana Avramov-Zamurovic1, Bryan Waltrip 2, Andrew Koffman 2 and George Piper1 1 United States Naval Academy, Weapons and Systems Engineering Department Annapolis, MD 21402, Telephone: 410 293 6124 Email: avramov@usna.edu 2 National Institute of Standards and Technology, Electricity Division Gaithersburg, MD 21899. Telephone: 401 975 2438, Email: bryan.waltrip@nist.gov Introduction The United States Naval Academy is an undergraduate school with a successful engineering program. An underlying philosophy in the Systems Engineering Department is to emphasize hands-on experience while maintaining a solid theoretical background. To realize this principle, both teachers and students face many challenges. In this paper an attempt is made to teach students how to build a very accurate ac voltage divider with an uncertainty better than a part- per-million. This implies building a transformer-based divider. The idea is to bridge the gap between the state-of-the-art achievements in modern research and the undergraduate level of expertise. Several years ago a group of midshipmen built a voltage divider for a critical point experiment that was conducted in collaboration with a National Institute of Standards and Technology and NASA space shuttle program. In order for the students to be able to build a good transformer lots of coaching took place. This lecture is intended t o introduce an engineering student into the art of precise voltage-ratio measurements. There are a number of applications that use very precise voltage-ratio devices, but one of the most common is in impedance bridges. Measurement bridges are constructed in such a way that they allow comparison of a standard unit and a unit under test. The standard and the device under test are connected in series and the impedance of a device under test is calibrated by finding the voltage ratio of the serial connection (see Figure 1.). Impedance of resistors, capacitors, and inductors is tested using alternating current. Very often experiments in physics use the same concept to determine the properties of materials. The capacitance seems to be the most often measured quantity. In this paper we will concentrate on presentation of voltage-ratio devices. From Figure 1 it can be seen that the voltage ratio is obtained using an inductive voltage divider. There are a number of references that give technical details on inductive voltage divider design [1] [2]. But they are written by engineers deeply involved in research, for engineers doing the same. Our goal is to present a straightforward and comprehensible lecture on voltage divider design. “Proceedings of the 2002 American Society for Engineering Education Annual Conference & Exposition Copyright Ó 2002, American Society for Engineering Education” Main Menu

  • Evaluations of a Sampling Impedance Bridge

    by Yicheng Wang, Stephan Schlamminger, Bryan Waltrip, Michael Berilla

    This paper reports our effort to improve a sampling impedance bridge. Custom-modified ac multimeters together with optimized waveform digitizing software enable us to achieve a stability and resolution better than 1 part in 10 8 for nominal 1:1 voltage ratios around 1 kHz. We wish to leverage this new sampling capability to build a digital impedance bridge, aiming to derive the capacitance unit from the ac quantized Hall resistance.


  • A Comparison Between the NIST PJVS-Based Power Standard and the NRC Current- Comparator-Based Power Standard

    by Bryan C. Waltrip, Thomas L. Nelson, Eddy So, David Angelo

    This paper presents the results of a comparison of active/reactive power meter calibrations between the National Institute of Standards and Technology and National Research Council. The comparison was implemented using a transfer standard consisting of a highly stable commercial sampling-type power/energy meter. Active and reactive power measurements were made at 120 V, 5 A, 50 Hz, and 60 Hz. For active power, the measurements were made at applied current phase angles of 0°, +60°, and -60°. For reactive power, the measurements were made at applied current phase angles of +60°, +90°, -60°, and -90° . The results of the comparison indicate agreement to within the stated uncertainties of the participants.


  • Eddy Current Rail Inspection Using AC Bridge Techniques

    by Ze Liu, Andrew D. Koffman, Bryan C. Waltrip, Yicheng Wang

    AC bridge techniques commonly used for precision impedance measurements have been adapted to develop an eddy current sensor for rail defect detection. By using two detection coils instead of just one as in a conventional sensor, we can balance out the large baseline signals corresponding to a normal rail. We have significantly enhanced the detection sensitivity of the eddy current method by detecting and demodulating the differential signal of the two coils induced by rail defects, using a digital lock-in amplifier algorithm. We have also explored compensating for the lift-off effect of the eddy current sensor due to vibrations by using the summing signal of the detection coils to measure the lift-off distance. The dominant component of the summing signal is a constant resulting from direct coupling from the excitation coil, which can be experimentally determined. The remainder of the summing signal, which decreases as the lift-off distance increases, is induced by the secondary eddy current. This dependence on the lift-off distance is used to calibrate the differential signal, allowing for a more accurate characterization of the defects. Simulated experiments on a sample rail have been performed using a computer controlled X-Y moving table with the X-axis mimicking the train's motion and the Y-axis mimicking the train's vibrational bumping. Experimental results demonstrate the effectiveness of the new detection method.