Michael Berilla
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael Berilla has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Bryan C. Waltrip
National Institute of Standards and Technology, Gaithersburg, MD, USA
4 shared publications - Stephan Schlamminger
National Institute of Standards and Technology
3 shared publications - Yicheng Wang
National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD, United States of America
2 shared publications - Albert F. Rigosi
National Institute of Standards and Technology (NIST)
1 shared publication - Alireza R. Panna
Physical Measurement Laboratory, National Institute of Standards and Technology
1 shared publication - Andrew D. Koffman
National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD, United States of America
1 shared publication
Latest Publications
- Open Access
- 31 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-7
Comparison of a 100-pF Capacitor With a 12 906-Ω Resistor Using a Digital Impedance Bridge
We tested a digital impedance bridge in a hybrid structure for comparison of a capacitor with a resistor where the impedance ratio was measured in two separate parts. The modulus of the impedance ratio was matched arbitrarily close to the input-to-output ratio, in magnitude, of a two-stage inductive voltage divider by adjusting the operating frequency of the bridge; the residual deviation between the two together with the phase factor of the impedance ratio was measured using a custom detection system based on a four-channel 24-bit digitizer. The ratio of the inductive voltage divider was calibrated, in situ, using a conventional four-arm bridge with two known capacitors. Fluctuations of the source voltages were largely removed through postprocessing of the digitized data, and the measurement results were limited by the digitizer error. We have achieved an overall bridge resolution and stability of 0.02 μF/F in 2 hours for measuring a 100 pF capacitor relative to a 12906 Ω resistor at 1233 Hz. The relative combined standard uncertainty (k = 1) is 0.13 μF/F, dominated by the digitizer error.
- 31 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-7
Open AccessComparison of a 100-pF Capacitor With a 12 906-Ω Resistor Using a Digital Impedance Bridge
We tested a digital impedance bridge in a hybrid structure for comparison of a capacitor with a resistor where the impedance ratio was measured in two separate parts. The modulus of the impedance ratio was matched arbitrarily close to the input-to-output ratio, in magnitude, of a two-stage inductive voltage divider by adjusting the operating frequency of the bridge; the residual deviation between the two together with the phase factor of the impedance ratio was measured using a custom detection system based on a four-channel 24-bit digitizer. The ratio of the inductive voltage divider was calibrated, in situ, using a conventional four-arm bridge with two known capacitors. Fluctuations of the source voltages were largely removed through postprocessing of the digitized data, and the measurement results were limited by the digitizer error. We have achieved an overall bridge resolution and stability of 0.02 μF/F in 2 hours for measuring a 100 pF capacitor relative to a 12906 Ω resistor at 1233 Hz. The relative combined standard uncertainty (k = 1) is 0.13 μF/F, dominated by the digitizer error.
- Open Access
- 6 April 2021
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 126, 126006
Evaluations of a Detector-Limited Digital Impedance Bridge
We tested a simple digital impedance bridge using two nominally equal resistors to form a 1:1 ratio. We focused on resolution and stability of the detectors. Fluctuations of the source voltages were largely removed through postprocessing of the digitized data, and the measurement results were limited by the detector noise. This detector-limited operating condition was first demonstrated using three modified Keysight 3458A multimeters for measurements of the voltage ratios, achieving 0.01 μV/V type A uncertainty in less than 15 min at 1 kHz. In an effort to extend the applicable frequency range and develop a system with off-the-shelf components, we tested a system using three lock-in detectors for measuring small deviations from the perfect AC ratio of unity magnitude, achieving stabilities and resolutions of 0.1 μV/V in a few hours for each point from 1 kHz to 5 kHz.
- 6 April 2021
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 126, 126006
Open AccessEvaluations of a Detector-Limited Digital Impedance Bridge
We tested a simple digital impedance bridge using two nominally equal resistors to form a 1:1 ratio. We focused on resolution and stability of the detectors. Fluctuations of the source voltages were largely removed through postprocessing of the digitized data, and the measurement results were limited by the detector noise. This detector-limited operating condition was first demonstrated using three modified Keysight 3458A multimeters for measurements of the voltage ratios, achieving 0.01 μV/V type A uncertainty in less than 15 min at 1 kHz. In an effort to extend the applicable frequency range and develop a system with off-the-shelf components, we tested a system using three lock-in detectors for measuring small deviations from the perfect AC ratio of unity magnitude, achieving stabilities and resolutions of 0.1 μV/V in a few hours for each point from 1 kHz to 5 kHz.
- 24 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-6
Comparison of AC Power Referenced to Either PJVS or JAWS
The results of a comparison on active power meter calibrations at the National Institute of Standards and Technology (NIST) using a source of AC power referenced to either a programmable Josephson voltage standard (PJVS) or a Josephson arbitrary waveform synthesizer (JAWS) is presented. The measurements were made at 60 V RMS, 5 A RMS, and 50 Hz at a power factor of 1.0. The estimated uncertainty of the active power applied to a meter under test (MUT) of the two system configurations is within 2 μW/VA (k=1), and the comparison results demonstrate that the two system configurations agree to within 1 part in 106 for applied voltage, current, and phase. A discussion of the measurement techniques and major sources of error is given for applied power signals over the 50 Hz to 6 kHz frequency range.
- 24 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-6
Comparison of AC Power Referenced to Either PJVS or JAWS
The results of a comparison on active power meter calibrations at the National Institute of Standards and Technology (NIST) using a source of AC power referenced to either a programmable Josephson voltage standard (PJVS) or a Josephson arbitrary waveform synthesizer (JAWS) is presented. The measurements were made at 60 V RMS, 5 A RMS, and 50 Hz at a power factor of 1.0. The estimated uncertainty of the active power applied to a meter under test (MUT) of the two system configurations is within 2 μW/VA (k=1), and the comparison results demonstrate that the two system configurations agree to within 1 part in 106 for applied voltage, current, and phase. A discussion of the measurement techniques and major sources of error is given for applied power signals over the 50 Hz to 6 kHz frequency range.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Evaluations of a Sampling Impedance Bridge
This paper reports our effort to improve a sampling impedance bridge. Custom-modified ac multimeters together with optimized waveform digitizing software enable us to achieve a stability and resolution better than 1 part in 10 8 for nominal 1:1 voltage ratios around 1 kHz. We wish to leverage this new sampling capability to build a digital impedance bridge, aiming to derive the capacitance unit from the ac quantized Hall resistance.
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-2
Evaluations of a Sampling Impedance Bridge
This paper reports our effort to improve a sampling impedance bridge. Custom-modified ac multimeters together with optimized waveform digitizing software enable us to achieve a stability and resolution better than 1 part in 10 8 for nominal 1:1 voltage ratios around 1 kHz. We wish to leverage this new sampling capability to build a digital impedance bridge, aiming to derive the capacitance unit from the ac quantized Hall resistance.