HGHugo Gasca-Aragon

Hugo Gasca-Aragon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hugo Gasca-Aragon has a total of 55 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automated evaluation of a key comparison on gauge blocks applying the digital calibration certificate (DCC) and digital metrological expert (DME)

    by Guido Bartl, Hugo Gasca-Aragon, Daniel Hutzschenreuter, Richard Koops, Antti Lassila, Andrew Lewis, Georg Zechner

    This article provides a demonstration of the capabilities of the digital metrological expert (DME) in facilitating the evaluation of interlaboratory comparison results, for the first time in the field of dimensional measurements. Using the example case of gauge blocks, it is shown how data provided by the digital calibration certificate (DCC) XML schema enable the automated evaluation of the comparison based on machine-interpretable data formats. Therefore, a simulated interlaboratory comparison with artificial gauge block measurement results acts as a proof-of-principle test to assess the combination of DCC and DME close to practice. Applying automated statistical analyses, including the calculation of reference values, degrees of equivalence, and detection of outliers at a level of significance of 5 %, the DME allows for the assessment of different evaluation methods to select suitable approaches. Compared to the usual practice of a (semi-)manual evaluation of intercomparisons carried out by human experts, the key benefits include reduced time and effort, consistency in results, and the potential prevention of human errors. The demonstration paves the way for easy adaptation to similar use cases.

  • Open Access

    First international comparison of three different tabletop Kibble balances from 1 mg to 10 g

    by Johannes Konrad, Kumar Arumugam, Norbert Rogge, Christian Rothleitner, Hugo Gasca-Aragon, Leon Chao, Stephan Schlamminger, Suren Vasilyan, Thomas Fröhlich

    We compared results from three different tabletop Kibble balances operated at TU Ilmenau, Physikalisch-Technische Bundesanstalt, and National Institute of Standards and Technology using two circulated mass sets. Each set contained five International Organization of Legal Metrology (OIML) R 111 nominal values from 1 mg to 10 g and one deliberately chosen non-OIML value of 6.62 607 015 g. The manufacturers calibrated the sets independently against OIML E 1 target specifications. Data exchange used digital calibration certificates, and all calibration and participant results were withheld until the final unblinding and evaluation. For each mass, we calculated an inverse-variance weighted reference value from the three Kibble balance results and compared it with the manufacturer calibration value. The weighted reference values differed from the manufacturer values by at most 15 μ g. For the gram-level masses, the corresponding relative deviations were below 2.3 × 10 − 6 . Eleven of the 12 cases satisfied | E n | ⩽ 1 . The remaining case had E n = 1.3 . The individual Kibble balance results were less uniform: reported expanded uncertainties ranged from about 0.4 μ g to 160 μ g and differed by up to approximately a factor of 230 for the same nominal mass. These results indicate compatibility at the level of the weighted reference values, while the individual uncertainty levels and measurement performance are not uniform across implementations.

  • Building trustworthy smart cities: The system definition of the Smart Metrology Campus data infrastructure

    by Michael Benedict Ulbig, Daniel Hutzschenreuter, Hugo Gasca-Aragon, Michael Kurrat

    This article highlights the critical role of robust data infrastructure in enabling data-driven smart cities, emphasizing metrology and systems engineering to ensure reliability and interoperability. The Smart Metrology Campus (SMC) aims to facilitate reliable data science in smart cities by integrating sensor and meter data with metrology-based metadata. Prior research has established systems engineering as the optimal strategic framework for guiding such data engineering processes. Additionally, the subsequent concept phase has been demonstrated to align with the data engineering requirements for electricity data collection. Building on this, the present study extends the methodology by defining a data quality framework focused on trust in electricity meter data. The article further elaborates on the systems definition phase, utilizing outcomes from the concept definition, such as requirements and general architecture, to develop a detailed system architecture, including technology selection for subsystems. It explores methods and tools for efficient system definition, combining established techniques like requirements tables and criteria catalogs with software engineering approaches like entity-relationship models and mockups. These methods, alongside the data quality framework, are applied in a case study of the SMC, culminating in a fully specified system architecture with detailed subsystem descriptions to support implementation.


  • SIM.QM-S17 Ethanol in Aqueous Matrix: Supplement Key Comparison, Model 1

    by Marco Antonio Ávila Calderón, Hugo Gasca Aragón, Víctor Manuel Serrano Caballero, Mariana Arce Osuna, Eliane Cristina Pires Do Rego, Bruno Carius Garrido, Valnei Smarçaro da Cunha, Jelena Bebić, Katarina Banjanac, Adrian Vicent Claramunt, et al.

    Main text: To establish international measurement capabilities for the determination of ethanol in aqueous matrices, the CCQM Organic Analysis Working Group (OAWG) has performed three ethanol Key comparisons (2002: CCQM-K27a for forensic aqueous ethanol and CCQM-K27b for ethanol in wine as a commodity; 2005: CCQM-K27 subsequent studies - four levels of ethanol in water; 2007: CCQM-K27.2 Subsequent 2 for forensic levels). To provide an opportunity for the NMIs and DIs within the RMOs, three Key comparisons has been conducted within SIM (SIM.QM-K1, SIM.QM-K27) and AFRIMETS (AFRIMETS.QM-K27). In addition, for the NMIs to support their ethanol in aqueous matrices measurements capabilities, a Track A Model 2 (formerly known as Track B) Key comparison CCQM-K79 (2010) has been completed to compare aqueous ethanol certified reference material (CRM) solutions certified by the participant NMIs and DIs. The current comparison is important to NMIs and DIs to maintain their ethanol in water measurement capabilities, to claim it as a new one as well as to complement their existing measurement capabilities, mainly within the range where the alcohol meter (breathalyzer) needs to be calibrated and verified. In 2017, several NMIs and DIs in SIM expressed their interest in a complementary SIM.QM-K27 comparison, therefore CENAM and INMETRO agreed to collaborate for the realization of a SIM supplement comparison, which was identified as SIM.QM-K27.2019 by the OAWG, and the final assigned name by SIM was SIM.QM-S17. The main purpose of this comparison was to offer to SIM countries and other regions an additional opportunity for the NMI and DIs to evaluate their measurements capabilities in determining mass fraction of ethanol in an aqueous matrix within the mass fraction range from 0.1 mg/g to 5 mg/g. Fourteen laboratories were registered to take part in this comparison, and thirteen sent their results. This report presents the results of the SIM Key comparison SIM.QM-S17. The measurements capabilities demonstrated by the participants in SIM.QM-S17, underpin their ability to assign reference values of ethanol content in aqueous samples for both forensic and commodities applications. Successful participation in SIM.QM-S17 demonstrates the laboratories measurement capabilities in determining mass fraction of ethanol in an aqueous matrix within the mass fraction range from 0.1 mg/g to 5 mg/g. The study material was two batches of solutions of ethanol in water prepared gravimetrically at concentrations between 0.1 mg/g - 5 mg/g by CENAM, dispensed in glass bottles of 50 mL sealed with tear off aluminum crimp seals, with rubber stoppers. In previous SIM.QM.K27 comparison, the purity-corrected gravimetric value of the aqueous ethanol solutions assigned by the coordinating NMI was used to link SIM.QM-K27 to the CCQM-K27 Key comparison reference value (KCRV), where 1 % uncertainty was assigned to the KCRV to have the same uncertainty from the CCQM-K27.2. For this comparison, SIM.QM-S17 two levels aqueous ethanol solutions, the purity assigned by CENAM was not used for KCRV as was informed initially in the protocol, instead in 5-June-2020 at the OAWG, CENAM gravimetric values were presented, as well as the participants results evaluated by four different statistical approaches to assess the candidate KCRV. For both levels of ethanol in aqueous matrix solutions, the DerSimonian-Laird Weighted mean and the Hierarchical Bayes mean methods seem to give a better estimation of the KCRV ± KCRU95 candidate and was agreed by OAWG to use the Hierarchical Bayesian mean, from where the KCRV for SIM.QM-S17 Level 1 (Low-level) and Level 2 (high-level) were (240.92 ± 1.28) mg/kg (k =2) and (389.87 ± 1.52) mg/kg (k =2), respectively. All the thirteen participants in the SIM.QM-S17, including both coordinators, demonstrated their capability to measure ethanol in aqueous matrix in the mass fraction range of 0.1 mg/g to 5 mg/g. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  • Standardization and improvement program for creatinine measurement in human serum

    by H. Gasca-Aragon, M. Balderas-Escamilla, V. M. Serrano-Caballero, M. A. Avila-Calderon, A. G. Pabello-Poegner, R. Sierra-Amor, R. Ruiz-Arenas, A. M. Cueto-Manzano, L. Cortes-Sanabria, H. R. Martinez-Ramirez, et al.